Добавил:
Опубликованный материал нарушает ваши авторские права? Сообщите нам.
Вуз: Предмет: Файл:

Kluwer - Handbook of Biomedical Image Analysis Vol

.2.pdf
Скачиваний:
102
Добавлен:
10.08.2013
Размер:
25.84 Mб
Скачать

512

Suri et al.

[17]Helft, G., Worthley, S. G., Fuster, V., Zaman, A. G., Schechter, C., Osende, J. I., Rodriguez, O. J., Fayad, Z. A., Fallon, J. T., and Badimon,

J.J., Atherosclerotic aortic component quantification by noninvasive magnetic resonance imaging: An in vivo study in rabbits, J. Am. Coll. Cardiol., Vol. 37, No. 4, pp. 1149, 2001.

[18]Shinnar, M., Fallon, J. T., Wehrli, S., Levin, M., Dalmacy, D., Fayad, Z. A., Badimon, J. J., Harrington, M., Harrington, E., and Fuster, V., The diagnostic accuracy of ex vivo MRI for human atherosclerotic plaque characterization, Arterioscler. Thromb., Vasc. Biol., Vol. 19, No. 11, pp. 2756–2761, 1999.

[19]Toussaint, J. F., LaMuraglia, G. M., Southern, J. F., Fuster, V., and Kantor, H. L., Magnetic resonance images lipid, fibrous, calcified, hemorrhagic, and thrombotic components of human atherosclerosis in vivo, Circulation, Vol. 94, No. 5, pp. 932–938, 1996.

[20]Worthley, S. G., Helft, G., Fuster, V., Fayad, Z. A., Rodriguez, O. J., Zaman, A. G., Fallon, J. T., and Badimon, J. J., Noninvasive in vivo magnetic resonance imaging of experimental coronary artery lesions in a porcine model, Circulation, Vol. 101, No. 25, pp. 2956–2961, 2000.

[21]Toussaint, J. F., NMR sequences for biochemical analysis and imaging of vascular diseases, Int. J. Cardiovasc. Imaging, Vol. 17, No. 3, pp. 187– 194, 2001.

[22]Naghavi, M., Libby, P., Falk, E., Casscells, S. W., Litovsky, S., Rumberger, J., Badimon, J. J., Stefanadis, C., Moreno, P., Pasterkamp, G., Fayad, Z., Stone, P. H., Waxman, S., Raggi, P., Madjid, M., Zarrabi, A., Burke, A., Yuan, C., Fitzgerald, P. J., Siscovick, D. S., de Korte, C. L., Aikawa, M., Airaksinen, K. E., Assmann, G., Becker,

C.R., Chesebro, J. H., Farb, A., Galis, Z. S., Jackson, C., Jang, I.-K., Koening, W., Lodder, R. A., March, K., Demirovic, J., Navab, M., Priori, S. G., Rekhter, M. D., Bahr, R., Grundy, S. M., Mehran, R., Colombo, A., Boerwinkle, E., Ballantyne, C., Insull, W., Jr., Schwartz, R. S., Vogel, R., Serruys, P. W., Hansson, G. K., Faxon, D. P., Kaul, S., Drexler, H., Greenland, P., Muller, J. E., Virmani, R., Ridker, P. M., Zipes, D. P.,

Lumen Identification, Detection, and Quantification in MR Plaque Volumes

513

Shah, P. K., and Willerson, J. T., From vulnerable plaque to vulnerable patient: A call for new definitions and risk assessment strategies, Part I, Circulation, Vol. 108, No. 14, pp. 1662–1772, 2003.

[23]Naghavi, M., Libby, P., Falk, E., Casscells, S. W., Litovsky, S., Rumberger, J., Badimon, J. J., Stefanadis, C., Moreno, P., Pasterkamp, G., Fayad, Z., Stone, P. H., Waxman, S., Raggi, P., Madjid, M., Zarrabi, A., Burke, A., Yuan, C., Fitzgerald, P. J., Siscovick, D. S., de Korte, C. L., Aikawa, M., Airaksinen, K. E., Assmann, G., Becker, C. R., Chesebro, J. H., Farb, A., Galis, Z. S., Jackson, C., Jang, I.-K., Koenig, W., Lodder, R. A., March, K., Demirovic, J., Navab, M., Priori, S. G., Rekhter, M. D., Bahr, R., Grundy, S. M., Mehran, R., Colombo, A., Boerwinkle, E., Ballantyne, C., Insull, W., Jr., Schwartz, R. S., Vogel, R., Serruys, P. W., Hansson, G. K., Faxon, D. P., Kaul, S., Drexler, H., Greenland, P., Muller, J. E., Virmani, R., Ridker, P. M., Zipes, D. P., Shah, P. K., and Willerson, J. T., From vulnerable plaque to vulnerable patient: A call for new deinitions and risk assessment strategies, Part II, Circulation, Vol. 108, No. 15, pp. 1772–1778, 2003.

[24]Fayad, Z. A., Fuster, V., Nikolaou, K., and Becker, C., Computed tomography and magnetic resonance imaging for noninvasive coronary angiography and plaque imaging: Current and potential future concepts, Circulation, Vol. 106, No. 15, pp. 2026–2034, 2002.

[25]Fuster, V., Fayad, Z. A., and Badimon, J. J., Acute coronary syndromes: Biology, Lancet, Vol. 353, pp. SII5–SII9, 1999.

[26]Cai, J. M., Hatsukami, T. S., Ferguson, M. S., Small, R., Polissar, N. L., and Yuan, C., Classification of human carotid atherosclerotic lesions with in vivo multicontrast magnetic resonance imaging, Circulation, Vol. 106, No. 11, pp. 1368–1373 2002.

[27]Xu, D., Hwang, J.-N., and Yuan, C., Atherosclerotic blood vessel tracking and lumen segmentation in topology changes situations of MR image sequences, In: Proceedings of the International Conference on Image Processing (ICIP), 2000, Vol. 1, pp. 637–640.

[28]Xu, D., Hwang, J.-N., and Yuan, C., Atherosclerotic plaque segmentation at human carotid artery based on multiple contrast weighting

514

Suri et al.

MR images, In: Proceedings of the International Conference on Image

Processing (ICIP), 2001, Vol. 2, pp. 849–852.

[29]Hatsukami, T. S., Ross, R., Polissar, N. L., and Yuan, C., Visalization of fibrous cap thickness and rupture in human atherosclerotic carotid plaque in vivo with high-resolution magnetic resonance imaging, Circulation, Vol. 102, No. 9, pp. 959–964, 2000.

[30]Yuan, C., Lin, E., Millard, J., and Hwang, J. N., Closed contour edge detection of blood vessel lumen and outer wall boundaries in blackblood MR images, Magn. Reson. Imaging, Vol. 17, No. 2, pp. 257–266, 1999.

[31]Yuan, C., Kerwin, W. S., Ferguson, M. S., Polissar, N., Zhang, S., Cai, J., and Hatsukami, T. S., Contrast-enhanced high resolution MRI for atherosclerotic carotid artery tissue characterization, J. Magn. Reson. Imaging, Vol. 15, No. 1, pp. 62–67, 2002.

[32]Yuan, C., Zhang, S.-X., Polissar, N. L., Echelard, D., Ortiz, G., Davis, J. W., Ellington, E., Ferguson, M. S., and Hatsukami, T. S., Identification of fibrous cap rupture with magnetic resonance imaging is highly associated with recent transient ischemic attack or stroke, Circulation, Vol. 105, No. 2, pp. 181–185, 2002.

[33]Zhang, S., Hatsukami, T. S., Polissar, N. L., Han, C., and Yuan, C., Comparison of carotid vessel wall area measurements using three different contrast-weighted black blood MR imaging techniques, Magn. Reson. Imaging, Vol. 19, No. 6, pp. 795–802, 2001.

[34]Zhao, X. Q., Yuan, C., Hatsukami, T. S., Frechette, E. H., Kang, X. J., Maravilla, K. R., and Brown, B. G., Effects of prolonged intensive lipid-lowering therapy on the characteristics of carotid atherosclerotic plaques in vivo by MRI: A case-control study, Arterioscler. Thromb. Vasc. Biol., Vol. 21, No. 10, pp. 1623–1629, 2001.

[35]Kerwin, W. S., Han, C., Chu, B., Xu, D., Luo, Y., Hwang, J.-N., Hatsukami, T. S., and Yuan, C., A quantitative vascular analysis system for evaluation of atherosclerotic lesions by MRI, In: Proceedings of the International Conference on Medical Image Computing

Lumen Identification, Detection, and Quantification in MR Plaque Volumes

515

and Computer-Assisted Intervention (MICCAI), 2001, Vol. 2208,

pp.786–794.

[36]Han, C., Hatsukami, T. S., and Yuan, C., A multi-scale method for automatic correction of intensity non-uniformity in MR images, J. Magn. Reson. Imaging, Vol. 13, No. 3, pp. 428–436, 2001.

[37]Zhang, Q., Wendt, M., Aschoff, A. J., Lewin, J. S., and Duerk, J. L., A multielement RF coil for MRI guidance of interventional devices, J. Magn. Reson. Imaging, Vol. 14, No. 1, pp. 56–62, 2001.

[38]Goldin, J. G., Yoon, H. C., Greaser, L. E., III, et al., Spiral versus electronbeam CT for coronary artery calcium scoring, Radiology, Vol. 221,

pp.213–221, 2001.

[39]Becker, C. R., Kleffel, T., Crispin, A., et al., Coronary artery calcium measurement: Agreement of multirow detector and electron beam CT, Am. J. Roentgenol., Vol. 176, pp. 1295–1298, 2001.

[40]Gaylord, G. M., Computed tomographic and magnetic resonance coronary angiography: Are you ready?, Radiol. Manag., Vol. 24, pp. 16–20, 2002.

[41]Haberl, R., Becker, A., Leber, A., et al., Correlation of coronary caldification and angiographically documented stenoses in patients with suspected coronary artery disease: Results of 1,764 patients, J. Am. Coll. Cardio., Vol. 37, pp. 451–457, 2001.

[42]Leber, A. W., Knez, A., Mukherjee, R., et al., Usefulness of calcium scoring using electron beam computed tomography and noninvasive coronary angiography in patients with suspected coronary artery disease, Am. J. Cardiol., Vol. 88, pp. 219–223, 2001.

[43]McConnell, M. V., Imaging techniques to predict cardiovascular risk, Curr. Cardiol. Rep., Vol. 2, pp. 300–307, 2000.

[44]Ohnesorge, B., Flohr, T., Fischbach, R., et al., Reproducibility of coronary calcium quantification in repeat examinations with retrospectively ECG-gated multisection spiral CT, Euro. Radiol., Vol. 12,

pp.1532–1540, 2002.

516

Suri et al.

[45]Sevrukov, A., Jelnin, V., and Kondos, G. T., Electron beam CT of the coronary arteries: Cross-sectional anatomy for calcium scoring, Am.

J.Roentgenol., Vol. 177, pp. 1437–1445, 2001.

[46]Bond, J. H., Colorectal cancer screening: The potential role of virtual colonoscopy, J. Gastroenterol., Vol. 37, No. 13, pp. 92–96, 2002.

[47]Chaoui, A. S., Blake, M. A., Barish, M. A., et al., Virtual colonoscopy and colorectal cancer screening, Abdom. Imaging, Vol. 25, pp. 361–367, 2000.

[48]Dobos, N. and Rubesin, S. E., Radiologic imaging modalities in the diagnosis and management of colorectal cancer, Hematol. Oncol. Clin.

N.Am., Vol. 16, No. X, pp. 875–895, 2002.

[49]Fenlon, H. M., Nunes, D. P., Clarke, P. D., et al., Colorectal neoplasm detection using virtual colonoscopy: A feasibility study, Gut, Vol. 43, pp. 806–811, 1998.

[50]Fenlon, H. M., Nunes, D. P., Schroy, P. C., III, et al., A comparison of virtual and conventional colonoscopy for the detection of colorectal polyps, N. Engl. J. Med., Vol. 341, pp. 1496–1503, 1999.

[51]Ferrucci, J. T., Colon cancer screening with virtual colonoscopy: Promise, polyps, politics, Am. J. Roentgenol., Vol. 177, pp. 975–988, 2001.

[52]Harvey, C. J., Renfrew, I., Taylor, S., et al., Spiral CT pneumocolon: Applications, status and limitations, Euro. Radiol., Vol. 11, pp. 1612– 1625, 2001.

[53]Mendelson, R. M., Foster, N. M., Edwards, J. T., et al., Virtual colonoscopy compared with conventional colonoscopy: A developing technology, Med. J. Aust., Vol. 173, pp. 472–475, 2000.

[54]Rex, D. K., Considering virtual colonoscopy, Rev. Gastroenterol. Disord. Vol. 2, pp. 97–105, 2002.

[55]Xynopoulos, D., Stasinopoulou, M., Dimitroulopoulos, D., et al., Colorectal polyp detection with virtual colonoscopy (computed tomographic colonography): The reliability of the method, Hepatogastroenterology, Vol. 49, No. 43, pp. 124–127, 2002.

Lumen Identification, Detection, and Quantification in MR Plaque Volumes

517

[56]Budoff, M. J., Oudiz, R. J., Zalace, C. P., et al., Intravenous three dimensional coronary angiography using contrast enhanced electron beam computed tomography, Am. J. Cardiol., Vol. 83, pp. 840–845, 1999.

[57]Lu, B., Budoff, M. J., Zhuang, N., et al., Causes of interscan variability of coronary artery calcium measurements at electron-beam CT, Acad. Radiol., Vol. 9, pp. 654–661, 2002.

[58]Mao, S., Budoff, M. J., Bakhsheshi, H., Liu, S. C., Improved reproducibility of coronary artery calcium scoring by electron beam tomography with a new electrocardiographic trigger method, Invest. Radiol., Vol. 36, pp. 363–367, 2001.

[59]Bielak, L. F., Rumberger, J. A., Sheedy, P. F., II, et al., Probabilistic model for prediction of angiographically defined obstructive coronary artery disease using electron beam computed tomography calcium score strata, Circulation, Vol. 102, No. 4, pp. 380–385, 2000.

[60]Takahashi, N. and Bae, K. T., Quantification of coronary artery calcium with multi-detector row CT: Assessing interscan variability with different tube currents-pilot study, Radiology, Vol. 228, No. 1, pp. 101–106, 2003.

[61]Pannu, H. K., Flohr, T. G., Corl, F. M., and Fishman, E. K., Current concepts in multi-detector row CT evaluation of the coronary arteries: Principles, Techniques, and Anatomy, Radiographics, Vol. 23, No. 90001, pp. S111–S125, 2003.

[62]Suri, J. S. and Liu, K., A review on MR vascular image processing algorithms: Acquisition and pre-filtering, Part-I, IEEE Trans. Inf. Tech. Biomed., Vol. 6, 2001.

[63]Suri, J. S., A review on MR vascular image processing algorithms: Skeleton vs. Non-skeleton Approaches, Part-II, IEEE Trans. Inf. Technol. Biomed., Vol. 6, 2002.

[64]Suri, J. S., An algorithm for time-of-flight black blood vessel detection. In: Proceedings of the 4th IASTED International Conference in Signal Processing, 2002, pp. 560–564.

518

Suri et al.

[65]Suri, J. S., Artery–Vein detection in very noisy TOF angiographic volume using dynamic feedback scale-space ellipsoidal filtering, In: Proceedings of the 4th IASTED International Conference in Signal Processing, 2002, pp. 565–571.

[66]Suri, J. S. and Laxminarayan, S. N., Angiography and Plaque Imaging: Advances Segmentation Techniques, CRC Press, Boca Raton, FL, 2003.

[67]Suri, J. S., Wilson, D. L., and Laxminarayan, S. N., Handbook of Medical Image Analysis: Segmentation and Registration Models, Marcel Dekker, New York, 2004.

[68]Suri, J. S., Two automatic training-based forced calibration algorithms for left ventricle boundary estimation in cardiac images, Int. Conf. IEEE Eng. Med. Biol., Vol. 2, pp. 538–541, 1997.

[69]Suri, J. S., Computer vision, pattern recognition and image processing in left ventricle segmentation: The last 50 years, Int. J. Patt. Anal. Appl., Vol. 3, No. 3, pp. 209–242, 2000.

[70]Suri, J. S., Kamaledin, S., and Singh, S., Advanced Algorithmic Approaches to Medical Image Segmentation: State-of-the-Art Applications in Cardiology, Neurology, Mammography and Pathology, 2001.

[71]Suri, J. S. and Laxminarayan, S. N., PDE and Level Sets: Algorithmic Approaches to Static and Motion Imagery, Kluwer Academic/Plenum Publishers, 2002.

[72]Salvado, O., Hillenbrand, C., Zhang, S., Suri, J. S., and Wilson, D., MR signal inhomogeneity correction for visual and computerized atherosclerosis lesion assessment, In: IEEE International Symposium on Biomedical Imaging: From Nano to Macro (ISBI), Arlington, VA, 2004.

[73]Yabushita, H., Bouma, B. E., Houser, S. L., Aretz, H. T., Jang, I.-K., Schlendorf, K. H., Kauffman, C. R., Shishkov, M., Kang, D.-H., Halpern, E. F., and Tearney, G. J., Characterization of human atherosclerosis by optical coherence tomography, Circulation, Vol. 106, No. 13, pp. 1640– 1645, 2002.

Lumen Identification, Detection, and Quantification in MR Plaque Volumes

519

[74]Nair, A., Kuban, B. D., Obuchowski, N., and Vince, D. G., Assessing spectral algorithms to predict atherosclerotic plaque composition with normalized and raw intravascular ultrasound data, Ultrasound Med. Biol., Vol. 27, No. 10, pp. 1319–1331, 2001.

[75]Wink, O., Niessen, W. J., and Viergever, M. A., Fast delineation and visualization of vessels in 3-D angiographic images, IEEE Trans. Med. Imaging, Vol. 19, No. 4, pp. 337–346, 2000.

[76]Wink, O., Niessen, W. J., and Viergever, M. A., Fast quantification of abdominal aortic aneurysms from CTA volumes, In: Proceedings of Medical Image Computing and Computer Assisted Intervention, 1998,

pp.138–145.

[77]Niessen, W. J., Montauban van Swijndregt, A. D., Elsman, B. H. P., Wink, O., Mali, W. P. Th. M., and Viergever, M. A., Improved artery visualization in blood pool MRA of the peripheral vasculature, In: Proceedings on Computer Assisted Radiology and Surgery (CARS), 1999,

pp.119–123.

[78]Udupa, J. K., Odhner, D., Tian, J., Holland, G., and Axel, L., Automatic clutter free volume rendering for MR angiography using fuzzy connectedness, SPIE Proc., Vol. 3034, pp. 114–119, 1997.

[79]Saha, P. K. and Udupa, J. K., Scale-based fuzzy connectivity: A novel image segmentation methodology and its validation, Proc. SPIE Conf. Med. Imaging, Vol. 3661, pp. 246–257, 1999.

[80]Udupa, J. K. and Samarasekera, S., Fuzzy connectedness and object delineation: Theory, algorithm, and applications in image segmentation, Graph. Models Image Process., Vol. 58, No. 3, pp. 246–261, 1996.

[81]Saha, P. K., Udupa, J. K., and Odhner, D., Scale-based fuzzy connected image segmentation: theory, algorithm, and validation, Comput Vis. Image Understanding, Vol. 77, No. 2, pp. 145–174, 2000.

[82]Udupa, J. K. and Odhner, D., Shell rendering, IEEE Comput Graph. Appl., Vol. 13, No. 6, pp. 58–67, 1993.

520

Suri et al.

[83]Lei, T., Udupa, J. K., Saha, P. K., and Odhner, D., MR angiographic visualization and artery-vein separation, Proc. of SPIE, Int. Soc. Opt. Eng., Vol. 3658, pp. 58–66, 1999.

[84]Sato, Y., Nakajima, S., Shiraga, N., Atsumi, H., Yoshida, S., Koller, T., Gerig, G., and Kikinis, R., Three-dimensional multi-scale line filter for segmentation and visualization of curvilinear structures in medical images, Med. Image Anal., Vol. 2, No. 2, pp. 143–168, 1998.

[85]Sato, Y., Chen, J., Harada, N., Tamura, S., and Shiga, T., Automatic extraction and measurements of leukocyte motion in micro vessels using spatiotemporal image analysis, IEEE Trans. Biomed. Eng., Vol. 44, No. 4, pp. 225–236, 1997.

[86]Sato, Y., Nakajima, S., Atsumi, H., Koller, T., Gerig, G, Yoshida, S., and Kikinis, R., 3-D multi-scale line filter for segmentation and visualization of curvilinear structures in medical images, In: Proceedings on CVRMed and MRCAS (CVRMed/MRCAS), 1997, pp. 213–222.

[87]Sato, Y., Araki, T., Hanayama, M., Naito, H., and Tamura, S., A viewpoint determination system for stenosis diagnosis and quantification in coronary angiographic image acquisition, IEEE Trans. Med. Imaging, Vol. 17, No. 1, pp. 121–137, 1998.

[88]Frangi, A. F., Niessen, W. J., Hoogeveen, R. M., van Walsum, Th., and Viergever, M. A., Model-based quantification of 3-D magnetic resonance angiographic images, IEEE Trans. Med. Imaging, Vol. 18, No. 10,

pp.946–956, 1999.

[89]Berliner, J. A., Navab, M., Fogelman, A. M., Frank, J. S., Demer, L. L., Edwards, P. A., Watson, A. D., and Lusis, A. J., Atherosclerosis: Basic mechanismsm Oxidation, inflammation, and genetics, Circulation, Vol. 91, No. 9, pp. 2488–2496, 1995.

[90]Botnar, R. M., Stuber, M., Kissinger, K. V., Kim, W. Y., Spuentrup, E., and Manning, W. J., Noninvasive coronary vessel wall and plaque imaging with magnetic resonance imaging, Circulation, Vol. 102, No. 21,

pp.2582–2587, 2000.

Lumen Identification, Detection, and Quantification in MR Plaque Volumes

521

[91]Breen, M. S., Lancaster, T. L., Lazebnik, R., Aschoff, A. J., Nour S. G., Lewin J. S., and Wilson, D. L., Three dimensional correlation of MR images to muscle tissue response for interventional MRI thermal ablation, Proc. SPIE Med. Imaging, Vol. 5029, pp. 202–209, 2001.

[92]Carrillo, A., Wilson, D. L., Duerk, J. L., and Lewin, J. S., Semi-automatic 3D image registration and applied to interventional MRI liver cancer treatment, IEEE Trans. Med. Imaging, Vol. 19, No. 3, pp. 175–185, 2003.

[93]Chalan, V. and Kim, Y., A methodology for evaluation of boundary detection algorithms on medical images, IEEE Trans. Med. Imaging, Vol. 16, No. 5, pp. 642–652, 1997.

[94]Clarke, L. P., Velthuizen, R. P., Camacho, M. A., Heine, J. J., Vaidyanathan, M., Hall, L. O., Thatcher, R. W., and Silbiger, M. L., MRI segmentation: Methods and applications, Magn. Reson. Imaging, Vol. 13, No. 3, pp. 343–368, 1995.

[95]Correia, L. C. L., Atalar, E., Kelemen, M. D., Ocali, O., Hutchins, G. M., Fleg, J. L., Gerstenblith, G., Zerhouni, E. A., and Lima, J. A. C., Intravascular magnetic resonance imaging of aortic atherosclerotic plaque composition, Arterioscler. Thromb. Vasc. Biol., Vol. 17, No. 12, pp. 3626–3632, 1997.

[96]Hagberg, G., From magnetic resonance spectroscopy to classification of tumors: A review of pattern recognition methods., NMR Biomed., Vol. 11, No. 4/5, p. 148, 1998.

[97]Hajnal, J. V., Saeed, N., Soar, E. J., Oatridge, A., Young, I. R., and Bydder, G., A registration and interpolation procedure for subvoxel matching of serially acquired MR images, J. Comput. Assist. Tomography, Vol. 19, No. 2, pp. 289–296, 1995.

[98]Hurst, G. C., Hua, J., Duerk, J. L., and Cohen, A. M., Intravascular (catheter) NMR receiver probe: Preliminary design analysis and application to canine iliofemoral imaging, Magn. Reson. Med., Vol. 24, No. 2, p. 343, 1992.