Software

7.5.2.2.9 StartUpdate

Reboots the Power Panel and starts the update process.

Function identical to: Service page Update Update settings / boot logo / system (button)

Path to the node (BrowsePath)

Path:

0:Root/0:Objects/2:DeviceSet/4:PowerPanelT80/2:MethodSet/4:StartUpdate

Alternative path (function group):

0:Root/0:Objects/2:DeviceSet/4:PowerPanelT80/3:Control/4:StartUpdate

Arguments for method call

Arguments -

7.5.2.3 Control/ConnectionWatchdog

Path to the object directory:

Path:

0:Root/0:Objects/2:DeviceSet/4:PowerPanelT80/3:Control/4:ConnectionWatchdog

ns BrowseName of the method

Description

4ConnectionWatchdogTimeout This parameter defines the period for the watchdog timeout or disables the watchdog function. ConnectionWatchdogTrigger This parameter is used firstly to enable the watchdog and secondly to trigger it.

7.5.2.3.1 ConnectionWatchdog - Function description

 

Power Panel

OPC UA

OPC UA

client

server

Trigger

Watchdog

 

timeout

If ConnectionWatchdog is active, the OPC UA client must send a trigger signal to the Power Panel within the timeout period. If the Power Panel does not receive a trigger signal within the defined timeout period, all LEDs of the Power Panel are disabled.

7.5.2.3.2 ConnectionWatchdogTimeout

This parameter defines the period for the watchdog timeout or disables the watchdog function. The following values are valid for ConnectionWatchdogTimeout:

Value [ms]

Description

0

This value immediately disables the watchdog.

500 to 10000

Timeout period in milliseconds.

 

The client must set parameter ConnectionWatchdogTrigger to value "true" within the time defined here if the watchdog is active.

Path to the node (BrowsePath)

Path:

0:Root/0:Objects/2:DeviceSet/4:PowerPanelT80/2:ParameterSet/4:ConnectionWatchdogTimeout

Alternative path (function group):

0:Root/0:Objects/2:DeviceSet/4:PowerPanelT80/3:Control/4:ConnectionWatchdog/4:ConnectionWatchdogTimeout

Node attributes

NodeClass

Variable

DataType

UInt16

AccessLevel

CurrentRead, CurrentWrite

UserAccessLevel

CurrentRead, CurrentWrite

Power Panel T80 User's manual V1.01

97