Virtuoso AMS Environment User Guide

Elaborating, Simulating, and Plotting Results

 

Corresponding

 

Field

spectre Option and

Effect

 

Parameter

 

 

 

 

Print analysis

tran stats

Prints analysis statistics.

statistics (stats)

 

 

Skipcount

tran skipcount

Directs the simulator to save only

 

 

one of every skipcount points.

Skipstart

tran skipstart

Specifies a time. The simulator

 

 

saves all computed data before this

 

 

time.

Skipstop

tran skipstop

Specifies a time to stop skipping

 

 

output data.

Strobeperiod

tran strobeperiod

Specifies an interval. The simulator

 

 

calculates and saves a data point in

 

 

each interval.

Strobedelay

tran strobedelay

Specifies an offset time relative to

 

 

the time specified bySkipstart.

 

 

 

3. When you are done changing options, click OK to save your changes.

Setting Waveform Selection Options

You can access the waveform selection options from the Cadence® hierarchy editor. These settings determine the kind and scope of probes that you create by selecting objects. For more information, see “Creating Probes” on page 277.

1.From the hierarchy editor, choose AMS – Options – Waveforms.

If the AMS menu entry is not visible, follow the instructions in “Preparing to Use AMS Designer from the Hierarchy Editor” on page 62.

April 2004

274

Product Version 5.3

Virtuoso AMS Environment User Guide

Elaborating, Simulating, and Plotting Results

The AMS Options window appears, showing the Waveforms pane.

2. Fill in and select fields as necessary.

April 2004

275

Product Version 5.3

Virtuoso AMS Environment User Guide

Elaborating, Simulating, and Plotting Results

The following table describes the effect of each control and field.

Field

Effect

 

 

Instance Values to

 

Save Or Plot

 

Voltages/Signals

Specifies whether to create voltage probes. The probes

 

return the voltage of electrical nets or the digital value of

 

nets that have disciplines from the discrete domain.

When the

 

objects are

 

Input ports

Specifies that only input ports are probed for voltage.

Output ports

Specifies that only output ports are probed for voltage.

All ports

Specifies that all ports are probed for voltage.

All data

Specifies that all ports and internal signals are probed for

 

voltage.

Levels of

 

hierarchy to save

 

All

Specifies that voltages are to be probed and saved for the

 

selected level and all lower levels of the hierarchy.

Levels

Specifies the number of levels (including the selected level)

 

that are probed for voltage. If you probe an instance for

 

both voltage and current, this Levels value is used for both,

 

even if the Levels value for Currents at terminals or

 

ports has a different value.

April 2004

276

Product Version 5.3

Соседние файлы в предмете [НЕСОРТИРОВАННОЕ]