Variables for ams.env Files

vlogSupply1Sigs

Specifies which signals are to be declared as supply1 wire types.

Syntax

amsDirect.prep vlogSupply1Sigs string "signal_list"

Values

 

signal_list

A list of signals to be declared, by default, as supply1 wires. The

 

default is an empty string.

Description

AMS Design Prep uses the value of this variable to determine which wires should be declared as supply1 wire types.

Example

For example, if the variable is defined like

amsDirect.prep vlogSupply1Sigs string "vdd! vdd2!"

then AMS Design Prep declares any new global signal named vdd! and vdd2! to be a supply1 wire type.

April 2004

576

Product Version 5.3

Virtuoso AMS Environment User Guide

Variables for ams.env Files

wfDefaultDatabase

Specifies the name of the default database for waveform data produced by the simulator. This name appears in the Default database name field, on theWaveforms pane of the AMS

Options window. It also appears as a database in the AMS Databases window and is used as the default

Syntax

amsDirect.prep wfDefaultDatabase string "database"

Values

 

database

The name of the default database for waveform data. The default

 

name is waves.

Example

amsDirect.prep wfDefaultDatabase string "fast_db"

Specifies that thefast_db database is to be the default database for waveform data produced by the simulator. This name fast_db appears in the AMS Databases window and is the default database for new selections in the AMS Save/Plot window.

April 2004

577

Product Version 5.3

Virtuoso AMS Environment User Guide

Variables for ams.env Files

wfDefInstCSaveAll

Specifies whether current probes are to be created for all levels of the instances selected from the schematic or the navigator.

Syntax

amsDirect.prep wfDefInstCSaveAll boolean t | nil

Values

 

t

Specifies that current probes are to be created for all levels of the

 

selected instances. This choice is indicated in the AMS Save/

 

Plot list by the word all appearing in the Depth column for the

 

selected instances.

nil

Specifies that current probes for the selected instances are to be

 

created only for the number of levels specified by the

 

amsDirect.prep wfDefInstCSaveLvl variable. This is the

 

default.

Example

amsDirect.prep wfDefInstCSaveAll boolean t

Specifies that current probes are to be created for all levels of the selected instances.

April 2004

578

Product Version 5.3

Virtuoso AMS Environment User Guide

Variables for ams.env Files

wfDefInstCSaveLvl

Specifies that current probes for the specified number of levels are to be created for instances selected from the schematic or the navigator.

Syntax

amsDirect.prep wfDefInstCSaveLvl int level

Values

 

level

The number of levels of current probes to be created for the

 

selected instances. The default value is 1.

Example

amsDirect.prep wfDefInstCSaveLvl int 2