- •Preface:
- •1 Machine specification
- •Installation and transportation
- •9 Nozzle leveling process
- •10 Mold exchange process:
- •1 1 Confirm mold thickness method
- •4 Electric control box panel
- •5 The description of each switch function 4-5-1 Injection resistance scale
- •5 0 0 M 0 0 -6 Safety door magnet spring switch
- •Vacuum solenoid valve
- •5. The description of operating menu screen
- •The above screen image is only for reference
- •The above screen image is only for reference
- •The above screen image is only for reference
- •Injector I Speed
- •Injector 1 Pressure
- •The above screen image is only for reference
- •The above screen image is only for reference
- •4 Inj.-l temp, setting -1
- •The above screen image is only for reference
The above screen image is only for reference
At the above screen press “Injector 1 speed” to display the ’’Injector 1 speed” screen °
Injection volume setting: The machine is 5 sections injection machine. Each section injection volume by oneself or automatic average share by computer.
If each section injection volume must set by oneself, check the small box which show at above figure and start from the last section (No. 5 section) to the front section setting the injection volume. If only set one of the section, the other sections will average share by computer.
Injection spfeed setting: According to the injection volume the machine is divided into 5 sections injection speed. Each section injection speed can set by oneself. Each section value indicates hydraulic oil flow rate (unit: L/min). The default value is 20~40. The value is too large means the injection speed is too fast. This value doesn’t set lower than 20.
Injector 1 last station right mold cannot set and it is also for display the function.
If the setting value is lower than 20, reduce the injection speed and injection pressure.2-1 Injector 1 injection pressure
1
16:12:38
0/28/2009
kg/cm 2 Right
Seg 1-4 Inj. Pressure kg/cm2 Left Right
Seg 5 Inj. Pressure Lef
t
o—
1
2
3
4
5
6
7
8
I* 0 i “
I “
.0
fast | |
0 |
I 0 |
|
0 |
p |
H |
|
||||||
injector l Speed |
I Injector 1 I Pressure |
Injector 1 Monitor I |
injector 2.1 Speed |
Injector 2 Pressure |
Injector 2 Monitor |
Main Paqe |
The above screen image is only for reference
At the above screen press “Injector 1 pressure” to display the screen.
It can set No. 1 -4 and No.5 section left or right mold injection pressure value.
Decrease the injection pressure value, it can cause decrease the injection speed.
Injector 1 last station right mold cannot set and it is also for display the function.Tienyu
5-2-2 Injector 1 monitor
|
16:13: |
12 |
|
10/28/2009 |
||||
|
|
|
|
|
|
|
||
|
|
Left |
|
|
Right |
|
||
St |
|
e ::jl ' Inj Speed ilfmi |r |
jTVol. |
(g) Inj. Time (sec)!nj |
Speed clpMj |
Inj. Vol. (g) |
||
1 |
0.0 |
0.0 |
0.0 |
■ 0 iff-; §11 |
0.0 |
0.0 |
||
2 |
0-0 |
0.0 |
0.0 |
|
:*'o.o';% J |
o.<; |
||
3 |
0,0 |
|
lijfj |
0.0 |
o.o |
0.0 |
||
4 |
0.0 |
|
0.0 |
0.0 |
0.0 |
o.o r |
||
5 |
|
|
0.0 |
; 'Q*p. |
,fo,d '/fl, |
0.0 |
||
6 |
0.0 |
m is |
;o.o |
; : oao : |
0.0 |
0.0 |
||
|
0.0 |
|
0.0 |
0.0 |
0.0 |
0.0 |
||
8 |
0.0. |
0.0 |
0.0 |
|
|
|
||
|
Cu fil |
itstjpRe: |
|
i SegmentiRemaining |
(g) |
|||
|
|
: Rate': ^ ^ JDfD V |
|
! No: 2 lo. 3 |
No. 4 No. 5 |
slop ; ’ |
||
|
Total t |
'eeJing .,p |
|
0,0 0.0 |
■ .KQ jtyiO ' |
Q.Q |
||
injector i 1 |
Injector 1 1 Injector 1 |
flnjector 5'1 Injector 2 j |
Injector 2 j |
Hl£M |
||||
: |
Speed 1 |
Pressure 1 Monitor |
1 Speed 1 Pressure 1 |
Monitor l- |
Page |