Dredge Function

Fig.1

Dredge

Quality

Fig. 2

When CTS is switched from 0 to 5 volts, quality is switched from 0 to 1 and CTS becomes equal to 0 volt, then the quality becomes equal to 2 during the time out (1). This time out may be defined by user. Get more information on "How To Set Up Time Out"

Inactive dredge (Quality = 0)

When MaxSea receives a 0 volt signal without having ever received a 5 volt one, the state automatically turns to 0

(inactive dredge).

Active dredge (Quality = 1 and the track is red)

When the software receives a 5 volt signal, the state turns to 1 (active dredge) and the track is on.

Note: it is impossible to Manually stop the track or Activate the track parameters choice dialog or Use the Man overboard function.

Hanging dredge (Quality = 2 and the track is blue )

When MaxSea does not receive anymore signal, the state turns to 2 (waiting for a new state, active or inactive) the track color turns to blue and the track save is still going on.

Then, if the signal is not received within TimeOut, MaxSea automatically turns the state to 0, the track is off.

The software stops the track save and suggests to "save as" the track in an existing file named "*.ptf".

Note that you can modify the TimeOut (for that, see paragraph TimeOut Preferences below).

Note : It is possible to create a new destination folder to save the dredge track in a new. PTF file. But it will be impossible to modify this file.

Then, the track is saved in an ASCII format file named "AAAAMMJJ.HHh.DRA.txt", the software suggests you to create a new destination folder for it.

319

MaxSea Operator Manual version 12.6

Setting Up Time Out

How to input Time Out

1.Select [Data Input-Output Settings] from the [Utilities] menu and click on the "Dredge" Tab

2.Click on corresponding line in the dialog

3.Click on the Advanced Settings button to display the Time Out edit box

4.Enter a value to define the delay before stopping the Dredge track ( equal to 60sec by default)

For Example:

In case the time out is defined

If you stop the dredge, then after 60sec the dredge track will be stopped if you did not activated the dredge again.

320

Sounder Depth Profile

Depth Profile Overview

When a sounder is connected to MaxSea, the measurement from the sounder is recorded for each point and MaxSea can thus be used to display the bottom profile.

IMPORTANT - To round out the MaxSea-NavNet integration Depth Profile can be added. The Network Sounder is a dual-frequency plugs directly into a NavNet display or into the Ethernet Hub with a single cable. MaxSea-NavNet Depth Profile display gives then an accurate numeric depth data readings. This option is only available when NavNet system is connected to MaxSea.

Activate the Depth Profile Window

1.Click The Chart Desktop Mode on the Toolbar and choose to display the Depth Profile Window with a number of chart window as you want.

2.By default if a NavNet system is connected the Depth profile window is selected on NavNet mode and the Sounder toolbar is displayed. Click on the Depth profile mode on the toolbar to select a Depth profile mode. Toggle between NavNet or MaxSea or Historic mode.

There are three viewing modes; NavNet Mode, MaxSea Mode and Historic Mode:

1.NavNet Mode is the Time Advance display mode, echo displayed at each new echo arrival (up to 5/sec). The X Axis is echo based (no unit). You can choose to display Echo graph either in single or dual frequency ( following picture shows you the dual frequence display.)

2.MaxSea Mode is the Distance Advance display mode. The echogram and the Depth Profile Outline are updated every new GPS position (usually less than 1sec). The X Axis is distance-based (same as SPEED SENSING PRR) If the boat does not move, the echogram does not advance.

321

MaxSea Operator Manual version 12.6

3.Historic Mode is the profile of your boat 's Track. The profile window is always associated to a track , either a previously saved old track (Historic Mode), or the current track (MaxSea Mode.)

Note that the Depth Profile display mode by default is selected on NavNet Mode.

The Depth Profile window can also be opened from [Navigation Mode] under the [Windows] menu.

Switching between NavNet Mode and MaxSea Mode:

1.Click the "Depth Profile Information" arrow to open the drop-down menu list.

2.Either click NavNet Mode or MaxSea Mode depending on your choice.

In this section you will learn on :

1 - Let's take a brief tour around the different Depth Profile's toolbars

Depth Profile Window Toolbar with NavNet Mode selected

Depth Profile Window Toolbar with MaxSea Mode selected

Depth Profile Window Toolbar with Historic Mode selected

2 - NavNet MODE

Changing the NavNet Depth Profile Point View

Selecting a NavNet Depth Profile Display

Marker Zoom Display Mode

Bottom Zoom Display Mode

Bottom Lock Display Mode

Bottom Discrimination Display Mode

3 - MaxSea Depth Profile Window Quick View

Changing the MaxSea Depth Profile Point View

Selecting a MaxSea Depth Profile Display

GPS in the Depth Profile Window

Depth Profile Outline

Forward Looking Depth Profile

Tides corrections

Locate your cursor

322

Sounder Depth Profile

Plot "Events" to mark Fish Schools

4 - Historic Mode

Changing the NavNet Depth Profile Point View

Selecting a NavNet Depth Profile Display

5 - NavNet Layers

Echogram

A-scope

Temperature Graph

Transmission frequency

See Also Related Topics:

1.Option : Navnet... (to choose and configure the NavNet System that you are using.)

2.Configuring Sounder Options... ( To adjust by default : Gain level, chosen mode between Manual and Auto, Noise Limiter, Clutter , Time Variable Gain and Draught Offset.)

NavNet Mode

NavNet Depth Profile Window Quick View

MaxSea-NavNet Depth Profile's display gives an accurate numeric depth data readings.

Echogram displayed in Dual frequency Mode (LF shown by number 2 and HF shown by number 1)

323

MaxSea Operator Manual version 12.6

Echogram displayed in Single frequency Mode (Echo frequency was switched between HF shown by number 1 and LF shown by number 2)

The NavNet Depth Profile's Window can help you on :

Locating schools of fish and their depths.

Determining bottom discrimination,.

Locating shipwrecks, reefs, and other objects between the keel and the bottom.

Determining the water depth and locating risks for navigation.

Determining the water temperature changes.

How to choose a Display Mode:

1.Click the Depth Profile drop down menu

2.Click again on a chosen display mode to select and unselect it. For more information see related topics: Selecting a NavNet Depth Profile Display and Changing the NavNet Depth Profile Point View

Available Echogram Display Modes when NavNet mode is chosen:

1.Marker Zoom Display Mode

2.Bottom Zoom Display Mode

3.Bottom Lock Display Mode

4.Bottom Discrimination Display Mode

Single or Double Window Frame for NavNet Depth Profile display, depending on the chosen display mode

Single Freq Dual Freq Marker Zoom Bottom Zoom Bottom Lock Bottom Discrimination

Left window

 

LF Frequency

Marker Zoom

Bottom Zoom

Bottom Lock

Bottom

frame

Always display

 

 

 

 

Discrimination

 

 

 

 

 

 

 

in primary

 

 

 

 

 

Right Window

window

HF Frequency

HF or LF

HF or LF

HF or LF

HF or LF

Frame

 

 

 

 

 

 

 

 

 

 

 

 

 

You will also learn on in this chapter:

Sounder settings optimization directly from the PC . (See related topic : Option : Sounder...)

-Gain,

-Auto mode,

-Noise limiter...)

How to easily and quickly change NavNet Depth Profile Sounder Display

"Transmission frequency" settings control

-High frequency

-Low frequency

324

Sounder Depth Profile

NavNet "Depth Profile" window including :

-Echogram showing both frequency modes HF and LF (Dual Freq display mode)

-Echogram showing single freqency mode (Single Freq mode)

-A-scope display

-Temperature Graph

NavNet Depth Profile Toolbar

NavNet Mode toolbar contains buttons which toggle display data on/off according to NavNet mode and the Sounder tools which allow you to adjust the echo sounder display.

file

NavNet

(1)

HF/LF

Display Mode

(7)

axSea Mode

(2)

(3)

(4)

(5)

(6)

 

Dual Freq

(8)

 

 

 

avNet Mode

 

 

 

 

 

 

Single Freq

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

istoric Mode

Marker Zoom

 

Bottom Zoom

 

Bottom Lock

 

Bottom Discrimination

Use corresponding buttons :

1

- to switch the display mode in the Depth Profile view and choose available mode between MaxSea,

NavNet or Historic.

2

- to switch the frequency and to toggle from HF to LF (see related topic: Transmission Frequency.)

3

- To change and choose a sounder mode between Manual or different Automatic modes (see related

topic: Sounder Toolbar.)

4

- To modify gain level when manual mode is chosen (see related topic: Sounder Toolbar.)

5

- To change the Sounder Echo Range (see related topic : Changing NavNet Depth Profile Sounder

Display.)

325

MaxSea Operator Manual version 12.6

6 - To change and the Sounder Echo Location in the graphical view (see related topic : Changing NavNet Depth Profile Sounder Display.)

7 - To switch between available NavNet Depth Profile Displays

8 - To show / Hide the A-scope in the depth profile view

9 - To show / hide the temperature graph in the depth profile view.

Sounder Toolbar

The Sounder Palette allows to quickly set up your view in the Depth Profile window for example if you want to switch frequence between LF and HF or mode between automatic and manual.

Setting Tools have been grouped together into the Sounder toolbar designed for quickly go to specific functions as it is explained on following :

Settings

User Interface

Available

Range

 

 

 

 

 

 

 

HF: Display in Hight Frequence

Switching

 

 

LF: Display in Lower Frequence

 

 

 

frequence

 

 

"HF" or "LF" information appears

 

 

 

 

 

 

on the left-hand corner of the

 

 

 

graphic view

 

 

 

 

 

 

 

Manual: this mode allows you to

 

 

 

adjust Range and shift in the depth

 

 

 

profile window view.

 

 

Either in

 

 

 

Cruising : automatic mode and no

Display Mode

 

MaxSea mode

 

 

or NavNet

adjust available

 

 

mode

 

 

 

 

 

 

 

 

Fishing: automatic mode and no

 

 

 

adjust available

 

 

 

 

 

 

 

Only available when Manual Mode

 

 

 

is chosen

Gain Level

 

 

To adjust the gain level, click on

 

 

 

the Gain level and drag the slider

 

 

 

to the desired location (value from

 

 

 

0 to 100 %)

 

 

 

 

 

 

 

Only available when Manual Mode

Range + and

 

Only in NavNet

is chosen.

-

 

Mode

Change the Range value by step

 

 

 

 

 

 

which can be defined between 0.5

 

 

 

m (minimum value for R-) and 100

 

 

 

 

More Information

Related Topic:

1.Moving In MaxSea Depth Profile Window

2.Changing Point of View in NavNet Depth Profile

3.Modifying Echo Graph's Display

4.Option : Sounder...

326

Sounder Depth Profile

m (maximal value for R+)

Only available when Manual Mode is chosen.

Switch between S-(Shift down the echo view) and S+(shift up the echo view).

Shift level

When NavNet Mode is toggled on, the S- shifts down the echogram view and S+ shifts up the echogram view in the Depth Window .

Changing the NavNet Depth Profile Sounder Display

In NavNet Mode you may only change Echogram Point of View in three display modes:

Either Manual or Fishing or Cruising.

Fishing and Cruising display modes are automatic.

The Manual Mode allows you to adjust the Range and the Shift echoes location.

Manual mode is selected on the Sounder toolbar.

S- and S+ buttons are available, click each one depending on your choice to move up or down the Echogram display view. A blue horizontal line delimits the echogram display down from it.

When S- is clicked the line moves upward and when S+ is clicked the line moves downward.

The Range buttons (R- and R+) are also available.

Selecting a NavNet Depth Profile Display

How to change the display in the NavNet Mode Depth Profile window::

Left-click on item in the Display Mode drop-down menu to show or hide the appropriate layer.

As it is shown beside the Single Freq is chosen and the Echogram is displayed in single frequency.

Dual Freq

Single Freq

Marker Zoom

327

MaxSea Operator Manual version 12.6

 

 

 

 

 

 

Bottom Zoom

 

 

 

 

 

 

 

 

 

 

 

 

 

Bottom Lock

 

 

 

 

 

 

 

 

 

 

 

 

 

Bottom Discrimination

 

 

 

 

 

 

 

Click on

to show or hide the A-scope in the Depth Profile Window (see also related topic: A-Scope)

Click on to show or hide the Temperature Graph overlaying on the echogram if there is the temperature data information in the NMEA sentence (see also related topic: Temperature Graph.)

Single or Double Window Frame for NavNet Depth Profile display, depending on the chosen display mode

 

Display Modes

 

 

Window

 

 

Data Displayed

 

 

 

 

 

 

 

 

 

 

Frame

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Single Freq

 

Single

This mode allows you to display the echogram in a single window either in LF or HF

 

(For more information see also related topic Transmission frequency.)

 

 

 

 

 

 

 

 

 

 

 

 

 

Marker Zoom

 

Double

This mode allows you to expand a selected area of the echogram and display it in the

 

left window frame (For more information see also related topic: Marker Zoom Display

 

 

 

 

 

 

Mode.)

 

 

 

 

 

 

 

Bottom Zoom

 

Double

This mode allows you to expand bottom and Bottom fish echoes by the zoom range

 

selected on the Sounder toolbar. It is useful for determining bottom hardness (For

 

 

 

 

 

 

more information see also related topic: Bottom Zoom Display Mode.)

 

 

 

 

 

 

 

Bottom Lock

 

Double

This mode allows you to provide a 10 or 20 feet (3 or 6 meter) wide layer in contact

 

with the bottom . You may range from the SOUNDER RANGE SETUP menu (For

 

 

 

 

 

 

more information see also related topic: Bottom Lock Display Mode.)

 

 

 

 

 

 

 

Bottom

 

Double

This mode allows you to display the bottom echo to help you determine bottom

 

hardness (For more information see also related topic:Bottom Discrimination Display

Discrimination

 

 

 

 

Mode.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: Dual Freq, Marker Zoom, Bottom Zoom, Bottom Lock and Bottom Discrimination modes are displayed in a double frame window.

Marker Zoom Display Mode

1.The Marker Zoom display expands a selected area of the echogram displayed in the left window frame.

328