Добавил:
Опубликованный материал нарушает ваши авторские права? Сообщите нам.
Вуз: Предмет: Файл:

Международные конвенции и кодексы. Том №3. Учебное пособие

.pdf
Скачиваний:
0
Добавлен:
07.09.2026
Размер:
2 Мб
Скачать
☆
МЕЖДУНАРОДНЫЕ КОНВЕНЦИИ И КОДЕКСЫ
ТОМ 3
81
LADDERS
required. Check connection to deck.
LIFERAFT BOARDING LADDERS
Layout, inspect, repair and renew as required. Check connection to deck.
13
LIFERAFT DAVIT
Check operation, condition of wires, release hooks and winch. Launching instruction clearly posted.
14
FREEFALL LIFEBOAT LAUNCHING & RECOVERY EQUIPMENT
Lowering rather than free-fall launching is acceptable provided free-fall launched at least once every six months.
15
RESCUE BOAT LAUNCHING & RECOVERY EQUIPMENT
Boat to be launched at intervals of not more than three months and manoeuvred in the water. Inspect & overhaul on-load release gear.
16
SECTION 2.0 (D) LIFESAVING APPLIANCES BEFORE S.E. SURVEY WORK (Annually)
ITEM
MAINTENANCE REQUIRED
MAINT. DATE &
OFFICER’S INTS.
LIFEBOAT / RESCUE BOAT EQUIPMENT
BOATS
Clean. If required, paint interior & exterior as required. Renew reflective tape
WIRE FALLS
Turn after 2
1/2
years, renew after five years. Log book entry to be made. Wire certificates. to be retained.
GRIPES
Renew if necessary
SPAN WIRE
Renew if necessary
TRICING PENNANTS
Renew if necessary
WINCHES
Rough up brake shoes. Check interior of casing for scale or grease. Log book to verify that the winch brakes were overhauled.
LIFE BOAT ON­LOAD RELEASE GEAR
Subject to a thorough examination and operational test during the annual surveys required by regulations I/7 and I/8 by properly trained personnel familiar with the system
GENERAL
Free and grease all shackles. Check all small fittings, e.g. steering oar grommet, etc. Check lifting hook for corrosion
SHIP EQUIPMENT
SURVIVAL CRAFT
Check operating instruction posters for lifeboat, liferaft and marine evacuation system ( if fitted )
LIFEJACKETS
Check donning instruction posters and lockers
LIFEBUOYS
Check weight, lifelines and beckets. Renew
15.6 LSSA Routine Maintenance – Annually
МЕЖДУНАРОДНЫЕ КОНВЕНЦИИ И КОДЕКСЫ
ТОМ 3
82
as require.
TABLE OF LIFESAVING SIGNAL
Check posted on the bridge or in ring binder.
LIGHTS, SHAPES AND SOUND SIGNALS
ELECTRIC NAVIGATION LIGHTS
Clean and check fittings, dogs, joints, plugs and sockets. Check that one complete set of available spare lamps required. Check and test indicator board. Check emergency supply
BELL
Clean, oil and check operation and condition
GONG &STRIKER
Clean, oil and check operation and cracks
TRAVELLERS FOR SPARE LIGHT
Overhaul or renew as repaired. Set up for survey
AIR WHISTLES
Renew lanyards and/or check overhaul sheaves as necessary. Top up hydraulic system and/or check electric circuits as applicable. Check valves and mechanical parts. Test.
SHAPES
Check condition and stowage. Paint black.
SIGNAL HALYARDS
Inspect and renew as required
SECTION 3.0 (A) FIREFIGHTING EQUIPMENT
THE FOLLOWING MAINTENANCE ITEMS ARE TO BE CARRIED OUT AT MONTHLY INTERVALS
ITEM
MAINTENANCE REQUIRED
MAINT. DATE &
OFFICER’S INTS.
FIRE MAIN & HYDRANTS
Pressure test fire main to inspect for leaks. Check all isolation valves and hydrants for free movement.
1
DRENCHER / SPRINKLER SYSTEM
Checks must be carried out as per manufacturers instructions
2
AUTOMATIC FIRE DETECTION SYSTEM
As per makers instruction. Test in conjunction with Engineering Dept.
3
ALARM SYSTEMS
Check that each alarm is in order and working correctly.
4
FIXED FIRE FIGHTING SYSTEM ( i.e. CO2, FOAM, HALON & POWDER )
Check freedom of access-doors and storage room cleanliness. Keys located, Instructions correctly posted and alarms working. Check control-valves, spindles, grease as applicable. Check and confirm that control valves are not temporarily or permanently secured in closed position. Check condition of pipelines. All other
5
15.7 FFA Routine Maintenance – Monthly Intervals
МЕЖДУНАРОДНЫЕ КОНВЕНЦИИ И КОДЕКСЫ
ТОМ 3
83
maintenance as per manufacturers instructions, record bottle contents
FIRE FLAPS, DAMPERS AND SKYLIGHT FOR ENGINE ROOM
Check operation and numbering. Ensure any remote operating controls / wires are free. Grease as applicable. (Plan of Fire Flaps / dampers location to be on bridge)
6
REMOTE SHUT OFF / QUICK CLOSING VALVES (F.O, D.O, ETC.)
Ensure wires etc. are free and in good condition.(test in conjunction with engineering department)
7
RESUSCITATING EQUIPMENT (SEE SECTION 1.0)
Check operation, condition of set and oxygen bottles, location & instruction manual in place. Record bottle contents
8
ESCAPE SETS (SEE SECTION 1.0)
Clean, Carry out checks as per manufacturer instructions. record bottle contents
9
FIREMAN'S OUTFITS & SCABA SETS (SEE SECTION 5.0)
Ensure location clearly marked, equipment all present including BA control board and readily accessible. Sharpen axes. Checks must be carried out in accordance with manufacturer’s instructions.
10
COMPRESSOR FOR BA AIR BOTTLES
Test as per manufacturers manual.(test in conjunction with engineering department)
11
FIRE CONTROL PLANS
Check that they are up-to-date and in position.
12
SAND BOXES AND SCOOPS
Clean and refill as necessary, Check scoop, grease dogs and hinges
13
FIRE BOXES
Inspect condition of box, hoses and couplings. Ensure spanner & nozzle in place and in good condition
14
FOAM BOXES
Inspect condition of box, hose & couplings and in line eductor.
15
INTERNATIONAL SHIP ­SHORE CONNECTION
Check location marked, ensure nuts and bolts are free and greased
16
SECTION 3.0 (B) FIREFIGHTING EQUIPMENT BEFORE S.E. SURVEY WORK (Annually)
ITEM
MAINTENANCE REQUIRED
MAINT. DATE &
OFFICER’S INTS.
FIRE FIGHTING EQUIPMENT
PIPING OF EXTINGUISHING GAS (ie.CO2) SYSTEM
Test equipment with compressed air. Check warning system.
15.8 FFA Routine Maintenance – Annually
МЕЖДУНАРОДНЫЕ КОНВЕНЦИИ И КОДЕКСЫ
ТОМ 3
84
FIXED FIRE FIGHTING SYSTEMS
Inspect for proper condition of all accessible components. Test equipment and check warning system & control valves.
SMOKE DETECTION SYSTEM
Test as per manufacturer instructions includes automatic shutdown of ventilation and fire doors.
FIRE DETECTION SYSTEM
Test as per manufacturer instructions includes automatic shutdown of ventilation and fire doors.
FIRE HOSES (SEE SECTION 6.0)
Test all hoses for leakage. Check couplings, washers and grease threads
SCABA SETS (SEE SECTION 5.0)
Clean out boxes, grease hinges. Check lifelines, harnesses fittings and signal cards. Check hose coupling screw fittings. All other maintenance as per manufacturers instructions
SMOKE HELMET / MASK
Check valves and glasses on helmets. Grease hinges and spring on bellows or mechanical parts on air pumps. Test
INSTRUCTIONS FOR MAINTENANCE AND OPERATION
Readily available in ship’s office includes
Installation manuals.
FIRE EXTINGUISHER AND BRACKET ( SEE SECTION 4.0 )
Check for proper location against safety plan, charging pressure, weight and condition.
FIRE HYDRANTS AND FIRE MAINS
Test operation and pressure as per SOLAS regulations
FIRE PUMPS AND SPRINKLER PUMPS
Flow test for proper pressures and flows.
FIRE DOORS / DAMPERS
Test for remote operation.
BA COMPRESSOR
Check air quality.
SPRINKLER SYSTEM
Check operation, flow alarm, lost pressure alarm and connection from fire mains.
ANTIFREEZE SYSTEM
Test for proper solutions.
SECTION 3.0 (B) FIREFIGHTING EQUIPMENT BEFORE S.E. SURVEY WORK (Annually)
ITEM
MAINTENANCE REQUIRED
MAINT. DATE &
OFFICER’S INTS.
INERT GAS SYSTEM
INERT GAS BLOWERS
Test as per manufacturers instructions
NON RETURN VALVE
Inspect and test the operation of the valve
DECK WATER SEAL
Test as per manufacturers instructions
REMOTE AND MANUALLY OPERATED
Check the operation of all valves
МЕЖДУНАРОДНЫЕ КОНВЕНЦИИ И КОДЕКСЫ
ТОМ 3
85
VALVES
SYSTEM ALARMS
Test using simulated conditions
OXYGEN ANALYSER
Check accuracy by means of calibration gas
OTHERS
SECTION 4.0 FIRE EXTINGUISHERS
MONTHLY MAINTENANCE
EXTINGUISHERS (GENERAL)
All extinguishers to have visually inspection of casing, hoses, horns. Ensure mounting secure and extinguisher readily accessible. Check sufficient amount of spares onboard.
ANNUAL MAINTENANCE
EXTINGUISHERS (GENERAL)
All extinguishers are to be pressure tested by the manufacturers at intervals not exceeding four (4) years.
WATER TYPE GAS PRESSURE
Check water level. Check contents of gas cartridge by weighing
FOAM TYPE GAS PRESSURE
Check fluid level. Check contents of gas cartridge by weighing
CARBON-DIOXIDE
Check contents by weighing
DRY-POWDER
Check powder for dampness and compacting due to vibration. Check contents of cartridges by weighing
NON-PORTABLE FOAM
Check fluid levels. Check working parts of trolley
NON-PORTABLE CARBON DIOXIDE
Check contents by weighing. Check working parts of trolley
HALON/BCF
Check gauge and/or contents by weighing
15.9 Fire Extinguishers Routine Maintenance
МЕЖДУНАРОДНЫЕ КОНВЕНЦИИ И КОДЕКСЫ
ТОМ 3
86
SECTION 7.0 NAVIGATIONAL EQUIPMENT
BEFORE S.E. SURVEY WORK (Annually)
The Following equipment is as required by SOLAS. It should be maintained in working condition at all times. This is given here as a checklist for use prior to SE Survey
ITEM
MAINT. DATE &
OFFICER’S INTS.
STANDARD MAGNETIC COMPASS
STEERING MAGNETIC COMPASS OR REFLECTOR TO THE STEERING POSITION
MEANS OF COMMUNICATION BETWEEN STANDARD COMPASS AND NORMAL NAVIGATIONAL CONTROL POSITION
MEANS OF TAKING BEARINGS THROUGH 360°
MAGNETIC COMPASS TABLE OF RESIDUAL DEVIATION SPARE MAGNETIC COMPASS
GYRO COMPASS (Annual Service)
HEADING INFORMATION AT EMERGENCY STEERING
RADAR (NUMBER ONE) ( 3 or 10 cm )
RADAR (NUMBER TWO, if fitted) ( 3 or 10 cm )
RADAR (NUMBER THREE, if fitted) ( 3 or 10 cm )
RADAR PLOTTING FACILITIES (Including Plotting Sheets)
AUTOMATIC RADAR PLOTTING AID (ARPA)
ECHO SOUNDER
SPEED AND DISTANCE INDICATOR
RUDDER ANGLE INDICATOR
PROPELLER REVOLUTION COUNTER
PROPELLER PITCH AND MODE INDICATOR
RATE OF TURN INDICATOR
RADIO DIRECTION FINDER
2182 kHz HOMING ON RDF
AUTOPILOT WITH CHANGEOVER INSTRUCTIONS
STEERING GEAR WITH CHANGEOVER INSTRUCTIONS
STEERING GEAR SYSTEM AUDIBLE & VISUAL ALARMS
NAUTICAL CHARTS AND PUBLICATIONS AVAILABLE AND UP TO DATE.
SIDE THRUSTERS PITCH INDICATION/OPERATIONAL MODE
DAY LIGHT SIGNALLING LAMP WITH EMERGENCY POWER SUPPLY
GPS
COURSE REORDER
A.I.S AUTOMATIC IDENTIFICATION SYSTEM
VOYAGE DATA RECORDERS (Effective fm 1st July 2002)
15.10 Navigational Equipment Maintenance
МЕЖДУНАРОДНЫЕ КОНВЕНЦИИ И КОДЕКСЫ
ТОМ 3
87
SECTION 8.0 COMMUNICATION EQUIPMENT ( GMDSS )
BEFORE S.E. SURVEY WORK (Annually)
The Following equipment is as required by SOLAS. It should be maintained in working condition at all times. This is given here as a checklist for use prior to SE Survey.
Test in conjunction with Electro Technical Officer.
ITEM
MAINTENANCE REQUIRED
MAINT. DATE &
OFFICER’S INTS.
GMDSS EQUIPMENT
VHF(s) with DSC
Check operation, performance, instruction cards, channel selection, antennae, emergency
power connection, ships’ position auto/manual
update and time (UTC).
SART(S)
Test against ships’ radar. Check correct locations and batteries expiry date.
NAVTEX
Check operation, instruction, printout and correct stations & messages selection. Test signal.
EGC RECEIVER ( No Navtex areas only )
Test in conjunction with Inmarsat-C, is part of standard SAT-C (SES).
EPIRB(s)
Check condition, expiry dates for batteries and hydrostatic release units. Test function.
PORTABLE VHF(s)
Check operation, performance, battery charger and emergency batteries expiry date.
MF/HF R/T with DSC & TELEX
Test and check operation, antennae, alarms, keyboard, display unit, printer, performance and emergency power supply.
INMARSAT-A and/or INMARSAT-B and/or INMARSAT-C and/or INMARSAT-M
Test and check operation, terminal, keyboard, display unit, printer, ancillary equipment, spare paper, antennas, alarms and emergency power supply.
EMERGENCY BATTERIES
Check charger units, housing, caps, connection, hydrometer test, room lighting, rubber mats, protective equipment, room ventilation, watertight door and warning labels.
GMDSS PUBLICATION AND OTHER
LIST OF RADIO SIGNALS
Check available onboard and update.
ITU PUBLICATIONS
Check available onboard and update.
GMDSS LOG
Check proper log entry and signatures.
INSTRUCTION CARD FOR EMERGENCY PROCEDURES
Check proper location and clearly posted.
CALLSIGN, STATION ID
Check proper location and clearly posted.
RADIO ROOM APPROVED CLOCK
Check functional.
15.11 GMDSS Equipment Maintenance
МЕЖДУНАРОДНЫЕ КОНВЕНЦИИ И КОДЕКСЫ
ТОМ 3
88
Практическое занятие
Задание № 1
На основании Safety Equipment certificate VLCC «Samail» заполните Safety
Equipment Book
Контрольные вопросы:
1 Кто ответственен на судне за содержание и обслуживание противопожарного
и спасательного имущества?
2 Какое основное требование предъявляется к противопожарному и
спасательному имуществу на судне?
3 Какое основное назначение Safety Equipment Book? 4 Что должен предпринять Ст. пом. капитана в случае поломки какого-либо
спасательного имущества?
5 Какая очередность или график проверок противопожарного и спасательного
имущества на судне?
6 В каких судовых журналах необходимо сделать записи о проведении
проверок противопожарного и спасательного имущества на судне?
7 В каком документе (сертификате) приводится перечень спасательного
имущества на судне?
8 В каких судовых документах находится описание и инструкции по
обслуживанию и ремонту противопожарного и спасательного имущества на судне?
Литература по практической работе:
1. Наставление по борьбе за живучесть судна (НБЖС), РД 31.60.14-81. С
приложениями и дополнениями / СПб: ЦНИИМФ – 2004.- 384 с. ISBN: 5-
93188-072-0
2. Международный кодекс по спасательным средствам (кодекс ЛСА) [Текст]/
СПб: ЦНИИМФ -2004. - 168 с. ISBN: 5-93188-062-3
3. Международный кодекс по системам пожарной безопасности (резолюция
MSC.98 (73) ИМО) [Текст]/ СПб: ЦНИИМФ -2004. - 128 с. ISBN: 5-93188-061-5
4. Рычков, В.А. Основы пожарной безопасности в порту и на судах [Текст]/ В.А.
Рычков СПб: ГМА им. Макарова- 2003. -44 с.
МЕЖДУНАРОДНЫЕ КОНВЕНЦИИ И КОДЕКСЫ
ТОМ 3
89
ПРАКТИЧЕСКАЯ РАБОТА № 16
УПРАВЛЕНИЕ РИСКАМИ (RISK MANAGEMENT)
Учебные вопросы:
16.1 Введение
16.2 Основные определения
16.3 Принципы оценки риска
16.4 Необходимые условия при оценке рисков
16.5 Библиотека оценок риска
16.6 Обязанности работников
16.7 Описание идентифицированных опасностей
16.8 Существующие меры предосторожности / безопасности
16.9 Оценка Фактора Риска
16.10 Оценка Фактора Риска (ФР), вытекающего из идентифицированных
опасностей
16.11 Дополнительные меры контроля для снижения степени риска
16.12 Пример оценки риска при выполнении работ судовым краном
16.1 Введение
Согласно законодательству по технике безопасности и охране труда
работодателям необходимо ввести и поддерживать на должном уровне систему Управления и оценки рисков для всех видов осуществляемой деятельности. Она распространяется на береговые структуры судовладельце и их суда.
Судовладелец устанавливает систему управления рисками для того, чтобы
определить потенциальные несоответствия и предотвратить их возникновение посредством исключения, уменьшения и/или смягчения рисков во всех видах своей деятельности. Оценки рисков должны быть произведены для того, чтобы охватить всевозможные опасности, которые могут проявиться в результате какой либо деятельности на борту судна. Это должно включать в себя обычные судовые операции, критические операции и ТО критического оборудования, чтобы любая опасность, связанная с выполнением рабочего процесса, могла быть идентифицирована и специфичные меры контроля (использование проверочных листов и т.д.) могли быть применены для снижения возможности возникновений инцидентов и профессиональных заболеваний на борту. Составление оценки рисков членами экипажа позволяет улучшить осведомленность членов экипажа по вопросам безопасности.
16.2 Основные определения
МЕЖДУНАРОДНЫЕ КОНВЕНЦИИ И КОДЕКСЫ
ТОМ 3
90
Опасность - это источник или ситуация, обладающие потенциалом для причинения вреда – травм или болезней, ущерба собственности, ущерба окружающей среде на рабочем месте или комбинация этих факторов, то есть что-то способное причинить вред. Риск - это комбинация вероятности возникновения определенного опасного события или воздействия опасного фактора и тяжести травмы или ухудшения состояния здоровья, которые будут результатом такого события или воздействия, то есть возможность возникновения чего-то неблагоприятного.
Фактор риска = Вероятность возникновения x Серьезность опасности.
Анализ риска - это систематическое использование всей имеющейся
информации для определения опасности и оценки опасности для человека, собственности или окружающей среды. Оценка риска - это процесс определения величины риска, возникающего из-за опасностей, учитывающий адекватность любых применяемых мер управления, а также принятия решения о допустимости риска, то есть процесс анализа и определения значения риска. Управление риском - систематическое использование управляющей политики, процедур и практики для целей анализа, оценки и управления риском.
16.3 Принципы оценки риска
Оценка риска это относительно простая задача и она представляет собой тщательный анализ всей той деятельности на борту судна, которая может наносить какой-либо ущерб. Этот процесс может выражаться, например, воздействием опасных веществ на здоровье человека и выработкой превентивных и подавляющих мер, таких как использование СИЗ, необходимости применения специфичного оборудования, любых мер предосторожности во время обработки вручную, которая может потребоваться, предупреждающих нотисов и справочной информации из паспорта безопасности на груз (MSDS). В процессе выполнения такой проверки меры предосторожности, уже имеемые в наличии, могут быть определены и решение о возможности применения дополнительных средств должно быть принято. Целью является предотвращение или как минимум сокращение вероятности возникновения инцидента или заболевания на судне, и потерях в рабочем процессе. Оценка риска должна распространяться на членов экипажа на борту, которые могут подвергаться каким-либо действиям или упущениям со стороны работодателя. При выполнении оценки, риск должен быть оценен как с учетом существующих мер предосторожности, которые уже приняты, так и тех превентивных мер, которые планируется предпринять. Если риск оказывается слишком высоким, то в таком случае меры безопасности недостаточны, и следует предпринять дальнейшие действия для снижения уровня риска. Этот процесс должен повторяться то тех пор, пока все риски не будут приведены до приемлемого уровня.
Соседние файлы в предмете [НЕСОРТИРОВАННОЕ]