Inlet

The Inlet node adds a boundary condition for inlets (inflow boundaries) in a Level Set interface. At inlets a value of the level set function must be specified. Typically set

to either 0 or 1.

B O U N D A R Y S E L E C T I O N

From the Selection list, choose the boundaries that represent inlets.

S E T T I N G S

Enter a value of the Level set function value . The value must be in the range from 0 to 1, and the default is 0.

Initial Interface

The Initial Interface node defines the boundary as the initial position of the interface.

B O U N D A R Y S E L E C T I O N

From the Selection list, choose the boundaries that represent the initial position of the

interface.

No Flow

The No Flow node adds a boundary condition that represents boundaries where there is no flow across the boundary. This is the default boundary condition.

B O U N D A R Y S E L E C T I O N

From the Selection list, choose the boundaries that are no-flow boundaries.

Outlet

The Outlet node adds a boundary condition for outlets (outflow boundaries) in a Level Set interface. This feature imposes no boundary condition on the level set function.

B O U N D A R Y S E L E C T I O N

From the Selection list, choose the boundaries that represent outlets.

T H E L E V E L S E T I N T E R F A C E | 221