C O N S T R A I N T S E T T I N G S

To display this section, click the Show button () and select Advanced Physics Interface Options. Select Use weak constraints as required.

Periodic Flow Condition

The Periodic Flow Condition splits its selection in two groups: one source group and one destination group. Fluid that leaves the domain through one of the destination boundaries enters the domain over the corresponding source boundary. This corresponds to a situation where the geometry is a periodic part of a larger geometry. If the boundaries are not parallel to each other, the velocity vector is automatically transformed.

If the boundaries are curved, it is recommended to only include two boundaries in a Periodic Flow Condition feature.

The Periodic Flow Condition has no input when the interface property Compressibility is set to Compressible flow (Ma<0.3). Typically when a periodic boundary condition is used with a compressible flow the pressure is the same at both boundaries and the flow is driven by a volume force. When Compressibility is set to Incompressible flow, the boundary condition contains an input field for a Pressure difference, psrc pdst. This pressure difference can, for example, drive the flow in a fully developed channel flow.

To set up a periodic boundary condition select both boundaries in the Periodic Flow Condition node. COMSOL automatically assigns one boundary as the source and the other as the destination. To manually set the destination selection, add a Destination Selection node to the Periodic Flow Condition node. All destination sides must be connected.

C O N S T R A I N T S E T T I N G S

To display this section, click the Show button () and select Advanced Physics Interface Options. Select Use weak constraints as required.

This boundary condition is not available if the Use memory-efficient form check box is selected (click the Show button () and select Advanced Physics Interface Options>Advanced Settings to display the section) on any

Note

single-phase flow interface Settings page.