The continuity boundary condition ensures that the pressure and mass flux are continuous. In addition, the following boundary condition is available on interior boundaries:

Pressure (also available for edges in 3D models)

1D Axi

2D Axi

For axisymmetric models, COMSOL Multiphysics takes the axial symmetry boundaries (at r = 0) into account and automatically adds an Axial Symmetry feature to the model that is valid on the axial symmetry boundaries only.

Pressure

The Pressure feature makes it possible to specify the pressure on a boundary. In many cases the distribution of pressure is known, giving the Dirichlet condition p = p0 where p0 is a known pressure given as a number, a distribution, or an expression involving time, t, for example.

B O U N D A R Y S E L E C T I O N

From the Selection list, choose the boundaries to specify the pressure.

P A I R S E L E C T I O N

If Pressure is selected from the Pairs menu, choose the pair to define. An identity pair has to be created first. Ctrl-click to deselect.

P R E S S U R E

Enter a value or expression for the Pressure p (SI unit: Pa).

Mass Flux

Use the Mass Flux feature to specify the mass flux into or out of the model domain through some of its boundaries. It is often possible to determine the mass flux from the pumping rate or from measurements. With the Mass Flux boundary condition, positive values correspond to flow into the model domain:

n -- p = N0

T H E D A R C Y ’ S L A W I N T E R F A C E | 317