Outlet

The Outlet feature adds a set of boundary conditions that describe the outlets in a fluid-flow simulation; that is, the conditions at boundaries where the fluid exits the domain. The following liquid boundary condition are available:

Velocity

Pressure, No Viscous Stress

No Viscous Stress

The Pressure, no viscous stress boundary condition is the default liquid boundary condition for outlet boundaries.

The formulations for the Outlet type are also available, possibly slightly modified, in other boundary types as well. This means that there is

nothing in the mathematical formulations that prevents a fluid from Note entering the domain through boundaries where the Outflow boundary

type is specified.

B O U N D A R Y S E L E C T I O N

From the Selection list, choose the boundaries that represent outlets.

L I Q U I D B O U N D A R Y C O N D I T I O N

From the Liquid boundary condition list, select one of the following boundary condition for the outlet:

Velocity

Using this boundary condition, specify that the velocity at the boundary is equal to a given velocity vector u0 (SI unit: m/s):

ul = u0

Enter the velocity components in the u0 fields.

Pressure, No Viscous Stress

Using this boundary condition, set the pressure to p0 and also make the viscous stress zero at the boundary:

 

ul

+ ul

T

 

2

 

p = p0 , l l + T

 

3--

ul I n = 0

254 | C H A P T E R 8 : B U B B L Y F L O W A N D M I X T U R E M O D E L B R A N C H E S