Wall

The Wall feature adds a selection of boundary conditions that describe the existence of a solid wall.

 

The following liquid boundary condition are available:

 

For The Laminar Bubbly Flow Interface:

 

No Slip (default)

 

Slip

Note

For The Turbulent Bubbly Flow Interface:

 

Slip

 

Wall functions (default)

 

 

 

The Wall feature by default specifies no gas flux for the gas phase.

B O U N D A R Y S E L E C T I O N

From the Selection list, choose the boundaries that represent walls.

L I Q U I D B O U N D A R Y C O N D I T I O N

From the Liquid boundary condition list, select one of the following liquid boundary conditions for the wall:

No Slip

Fixes the liquid velocity to zero:

ul = 0

This is the default boundary condition for the liquid.

Slip

Sets the velocity component normal to the wall to zero:

ul n = 0

Wall functions

This boundary condition prescribes a no-slip condition for solid walls in a turbulent flow. Wall Functions are used to model the thin region near the wall with high gradients in the flow variables.

T H E B U B B L Y F L O W I N T E R F A C E S | 251