Q.-Y. Li and L.-X. Wang

 

 

2.3\ Longitudinal Section

of the Mesoposition Uterus

in Fertile Woman

Fig. 12.13

Longitudinal section of the mesoposition uterus in fertile woman

Ut

Cx

Ut

12  Gynecologic Ultrasound Scanning

443

 

 

2.3.1\ Method

The patient should void the urinary bladder. Probe is placed in the vagina, the direction of sound beam through the middle longitudinal section of the uterus.

2.3.2\ Section Structure

The left part is the anterior wall of the uterus, the down part which is next to the probe is the cervix,

the right part is the posterior wall of the uterus, and toward the upper part is the uterus base. The hyperechogenicity line located at the uterus center is the endometrium.