Q.-Y. Li and L.-X. Wang

 

 

2.2\ Transection of the

Anteposition Uterus in Fertile

Woman

Fig. 12.12  Transection of the anteposition uterus in fertile woman

Ut

Ut

12  Gynecologic Ultrasound Scanning

441

 

 

2.2.1\ Method

The patient should void the urinary bladder. Probe is placed in the vagina, the direction of sound beam through the maximum transection of the uterus.

2.2.2\ Section Structure

The left is the right lateral wall of the uterus, the down part which is next to the probe is the anterior uterus wall, and the right is the left lateral wall of the uterus. The hyperechogenicity line located at the uterus center is the uterus cavity line.

2.2.3\ Measuring Method and Normal

Measuring the left-right diameter which is the width of the uterus, the normal value is 4.5–5.5 cm.

2.2.4\ The Clinical Application Value

The transaction is another important section to understand whether the size and shape of the uterus is normal. This section is also the most important one to show endometrium and intracavity information.