  1. At main screen press “General Parameter” to open the “General Parameter” screen.

  2. The above screen include “Input/Output” ' "Injector Slider” ' ’’Page Locking” ' ”Pre-heat” and “System Page” icon.

  3. Inj. 1 feeding delay: Setting inj. 1 feeding delay time. If setting inj. feeding delay time, it can

prevent the material feeding stop time too long during clean mold or other condition cause the injection stop too long time.

  1. Inj. 2 feeding delay: Setting inj. 2 feeding delay time. If setting inj. feeding delay time, it can

prevent the material feeding stop time too long during clean mold or other condition cause the injection stop too long time.

  1. Inj. 1 and 2 pre-compression time: Setting material pre-compression time before injection.

The pre-compression function can let the material reach to equality density in barrel and ensure injection volume control stability. According to the feeding volume to setting the pre-compression time. If the material feeding quantity increase the pre-compression time is too long. The default value is 2-6sec.

  1. Delay injector BWD.: Setting the delay injector BWD. time after complete injection.

.Max. Close Mold: Setting the max. close mold time value. If during the open/close moldTienvu

process cause extraordinary the function provide alarm signal, (e.g.: Mold thickness too thick, close mold doesn’t complete)

5

  1. The default max. close mold value: Normal close mold time + lsec.

  2. Max. feeding time: Set the max. feeding time. If during feeding process cause extraordinary

the function provide alarm (e.g.: No material, cannot reach the setting value).

  1. Max. inj. time: Setting the max. injection time value. If during the injection process cause

extraordinary the function provide alarm, (e.g.: Nozzle doesn’t open, material bum cause cannot injection)

  1. Before open mold: Setting the signal lamp light up time before complete curing time. If

approaching the open mold time the function remind the operator by signal lamp. According to the operation habit set the timing. The default value is 20sec~30sec.

  1. Open mold buzzer: Setting the start up buzzer time before open mold. If preparing to open

current mold the buzzer remind the operator. According to the operation habit set the timing. The default value is 3sec~5sec.

  1. Loading pressure: Setting the loading pressure. The default value is 100~120Kg/cm .(By

using proportional pressure/proportional flow for hydraulic system).

6

  1. Loading Back Pressure: Setting the screw BWD. stop during feeding. Ensure the injection

volume stable. The default value is 10 ~ 2 5 Kg/cm2. (By using proportional pressure/proportional flow for hydraulic system).

  1. Loading speed: Setting the material enters to barrel speed. The setting value is also indicates

hydraulic oil flow rate in hydraulic motor (unit: L/min.).

  1. Pre-compression pressure: Setting pre-compression pressure value before injection (unit:

Kg/cm2).

  1. Pre-compression speed: Setting pre-compression speed of material before injection. The

setting value is also indicates hydraulic oil flow rate in injection piston. The default value is 80 ~ 100 (unit: L/min.).

  1. Injection pressure: Setting max. injection pressure value. The default value is 100~

120Kg/cm2.

  1. Injection speed: Setting injection speed. The setting value indicates hydraulic oil flow rate

push the injection piston action. In manual mode uses this function and automatic mode doesn’t use this function. The default pressure value is 60 ~ 85 (unit: L/min.).

Auto mold open pressure release time setting : Setting each station before auto mold drain pressure time

.

1At curing time screen press the start button of ’’Vacuum setting” and display the above screen °

5-1