Добавил:
Sekretar
kiopkiopkiop18@yandex.ru
t.me/Prokururor I Вовсе не секретарь, но почту проверяю
Опубликованный материал нарушает ваши авторские права? Сообщите нам.
Вуз:
Предмет:
Файл:Ординатура / Хирургия / @xirurgi_2025 / @xirurgi_2025 - 715 - файл
.pdf
330
https://t.me/medicina_free
9. Holm C, Mayr M, Höfter E, Becker A, Pfeiffer UJ, Pfeiffer Mühlbauer
W. Intraoperative evaluation of skin-ap viability using laser-induced
uorescence of indocyanine green. Br J Plast Surg. 2002;55(8):635–44.
10. Wirts CW, Cantarow A.A study of the excretion of bromsulphthalein in
the bile. Am J Dig Dis. 1942;9(3):101–6. https://doi.org/10.1007/
BF02996980.
11. Paumgartner G, Vasella DL, Herz R, Reichen J, Preisig R.Hepatic extraction of taurocholate and indocyanine green in patients with liver disease
(author’s transl). Z Gastroenterol. 1979;17(11):753–61.
12. Rowell LB, Blackmon JR, Bruce RA.Indocyanine green clearance and
estimated hepatic blood ow during mild to maximal exercise in upright
man. J Clin Invest. 1964;43:1677–90. https://doi.org/10.1172/JCI105043.
13. Marano A, Priora F, Lenti LM, Ravazzoni F, Quarati R, Spinoglio
G.Application of uorescence in robotic general surgery: review of the
literature and state of the art. World J Surg. 2013;37(12):2800–11. https://
doi.org/10.1007/s00268- 013- 2066- x.
14. Blythe J, Herrmann E, Faust D, Falk S, Edwards-Lehr T, Stockhausen F,
etal. Acute cholecystitis- a cohort study in a real-world clinical setting
(REWO study, NCT02796443). Pragmat Obs Res. 2018;9:69–75. https://
doi.org/10.2147/POR.S169255.
15. Mangieri CW, Hendren BP, Strode MA, Bandera BC, Faler BJ.Bile duct
injuries (BDI) in the advanced laparoscopic cholecystectomy era. Surg
Endosc. 2019;33(3):724–30. https://doi.org/10.1007/s00464- 018-
6333- 7.
16. Madni TD, Nakonezny PA, Imran JB, Taveras L, Cunningham HB, Vela
R, etal. A comparison of cholecystitis grading scales. J Trauma Acute
Care Surg. 2019;86(3):471–8. https://doi.org/10.1097/
TA.0000000000002125.
17. Buddingh KT, Nieuwenhuijs VB, van Buuren L, Hulscher JB, de Jong JS,
van Dam GM.Intraoperative assessment of biliary anatomy for prevention of bile duct injury: a review of current and future patient safety interventions. Surg Endosc. 2011;25(8):2449–61. https://doi.org/10.1007/
s00464- 011- 1639- 8.
18. Flum DR, Flowers C, Veenstra DL.A cost-effectiveness analysis of intraoperative cholangiography in the prevention of bile duct injury during
laparoscopic cholecystectomy. J Am Coll Surg. 2003;196(3):385–93.
https://doi.org/10.1016/S1072- 7515(02)01806- 9.
19. Vlek SL, van Dam DA, Rubinstein SM, de Lange-de Klerk ESM,
Schoonmade LJ, Tuynman JB, etal. Biliary tract visualization using nearinfrared imaging with indocyanine green during laparoscopic cholecystectomy: results of a systematic review. Surg Endosc. 2017;31(7):2731–42.
https://doi.org/10.1007/s00464- 016- 5318- 7.
20. Aoki T, Murakami M, Yasuda D, Shimizu Y, Kusano T, Matsuda K, etal.
Intraoperative uorescent imaging using indocyanine green for liver
E. Tham et al.

11 Use of Fluorescence Guidance in Acute Care Surgery…
https://t.me/medicina_free
mapping and cholangiography. J Hepatobiliary Pancreat Sci.
2010;17(5):590–4. https://doi.org/10.1007/s00534- 009- 0197- 0.
21. Osayi SN, Wendling MR, Drosdeck JM, Chaudhry UI, Perry KA,
Noria SF, etal. Near-infrared uorescent cholangiography facilitates
identication of biliary anatomy during laparoscopic cholecystectomy. Surg Endosc. 2015;29(2):368–75. https://doi.org/10.1007/
s00464- 014- 3677- 5.
22. Bronikowski D, Lombardo D, DeLa OC, Szoka N.Robotic subtotal cholecystectomy in a geriatric acute care surgery patient with super obesity.
Case Rep Surg. 2021;2021:9992622. https://doi.
org/10.1155/2021/9992622.
23. Ambe PC, Plambeck J, Fernandez-Jesberg V, Zarras K.The role of indocyanine green uoroscopy for intraoperative bile duct visualization during laparoscopic cholecystectomy: an observational cohort study in 70
patients. Patient Saf Surg. 2019;13:2. https://doi.org/10.1186/s13037-
019- 0182- 8.
24. Broderick RC, Lee AA-O, Cheverie JN, Zhao B, Blitzer RR, Patel RJ,
et al. Fluorescent cholangiography signicantly improves patient outcomes for laparoscopic cholecystectomy. Surg Endosc.
2021;35(10):5729–39.
25. Ankersmit M, van Dam DA, van Rijswijk AS, van den Heuvel B,
Tuynman JB, Meijerink W.Fluorescent imaging with indocyanine green
during laparoscopic cholecystectomy in patients at increased risk of bile
duct injury. Surg Innov. 2017;24(3):245–52. https://doi.
org/10.1177/1553350617690309.
26. Boogerd LSF, Handgraaf HJM, Huurman VAL, Lam HD, Mieog JSD,
van der Made WJ, etal. The best approach for laparoscopic uorescence
cholangiography: overview of the literature and optimization of dose and
dosing time. Surg Innov. 2017;24(4):386–96. https://doi.
org/10.1177/1553350617702311.
27. Verbeek FP, Schaafsma BE, Tummers QR, van der Vorst JR, van der
Made WJ, Baeten CI, etal. Optimization of near-infrared uorescence
cholangiography for open and laparoscopic surgery. Surg Endosc.
2014;28(4):1076–82. https://doi.org/10.1007/s00464- 013- 3305- 9.
28. Strasberg SM, Brunt LM.Rationale and use of the critical view of safety
in laparoscopic cholecystectomy. J Am Coll Surg. 2010;211(1):132–8.
29. Lim SH, Tan HTA, Shelat VG. Comparison of indocyanine green dye
uorescent cholangiography with intra-operative cholangiography in
laparoscopic cholecystectomy: a meta-analysis. Surg Endosc.
2021;35(4):1511–20. https://doi.org/10.1007/s00464- 020- 08164- 5.
30. Turcotte J, Leydorf SD, Ali M, Feather C, Klune JR.Indocyanine green
does not decrease the need for bail-out operation in an acute care surgery
population. Surgery. 2021;169(2):227–31. https://doi.org/10.1016/j.
surg.2020.05.045.
331

332
https://t.me/medicina_free
31. Bryski MG, Frenzel Sulyok LG, Kaplan L, Singhal S, Keating
JJ.Techniques for intraoperative evaluation of bowel viability in mesenteric ischemia: a review. Am J Surg. 2020;220(2):309–15. https://doi.
org/10.1016/j.amjsurg.2020.01.042.
32. Tilsed JV, Casamassima A, Kurihara H, Mariani D, Martinez I, Pereira J,
et al. ESTES guidelines: acute mesenteric ischaemia. Eur J Trauma
Emerg Surg. 2016;42(2):253–70. https://doi.org/10.1007/s00068- 016-
0634- 0.
33. Adaba F, Askari A, Dastur J, Patel A, Gabe SM, Vaizey CJ, etal. Mortality
after acute primary mesenteric infarction: a systematic review and metaanalysis of observational studies. Color Dis. 2015;17(7):566–77. https://
doi.org/10.1111/codi.12938.
34. Szoka N, Kahn M. Acute-on-chronic mesenteric ischemia: the use of
uorescence guidance to diagnose a nonsurvivable injury. Case Rep Surg.
2022;2022:5459774. https://doi.org/10.1155/2022/5459774.
35. Son GM, Kwon MS, Kim Y, Kim J, Kim SH, Lee JW.Quantitative analysis of colon perfusion pattern using indocyanine green (ICG) angiography in laparoscopic colorectal surgery. Surg Endosc. 2019;33(5):1640–9.
https://doi.org/10.1007/s00464- 018- 6439- y.
36. Mehdorn M, Ebel S, Kohler H, Gockel I, Jansen-Winkeln B.Hyperspectral
imaging and indocyanine green uorescence angiography in acute mesenteric ischemia: a case report on how to visualize intestinal perfusion.
Int J Surg Case Rep. 2021;82:105853. https://doi.org/10.1016/j.
ijscr.2021.105853.
37. Nakagawa Y, Kobayashi K, Kuwabara S, Shibuya H, Nishimaki T.Use of
indocyanine green uorescence imaging to determine the area of bowel
resection in non-occlusive mesenteric ischemia: a case report. Int J Surg
Case Rep. 2018;51:352–7. https://doi.org/10.1016/j.ijscr.2018.09.024.
38. Irie T, Matsutani T, Hagiwara N, Nomura T, Fujita I, Kanazawa Y, etal.
Successful treatment of non-occlusive mesenteric ischemia with indocyanine green uorescence and open-abdomen management. Clin J
Gastroenterol. 2017;10(6):514–8. https://doi.org/10.1007/s12328- 017-
0779- 3.
39. Nitori N, Deguchi T, Kubota K, Yoshida M, Kato A, Kojima M, etal.
Successful treatment of non-occlusive mesenteric ischemia (NOMI)
using the HyperEye Medical System™ for intraoperative visualization of
the mesenteric and bowel circulation: report of a case. Surg Today.
2014;44(2):359–62. https://doi.org/10.1007/s00595- 013- 0503- y.
40. Guerra F, Coletta D, Greco PA, Eugeni E, Patriti A.The use of indocyanine green uorescence to dene bowel microcirculation during laparoscopic surgery for acute small bowel obstruction. Color Dis.
2021;23(8):2189–94. https://doi.org/10.1111/codi.15680.
41. Ryu S, Hara K, Goto K, Okamoto A, Kitagawa T, Marukuchi R, etal.
Fluorescence angiography vs. direct palpation for bowel viability evaluation with strangulated bowel obstruction. Langenbeck’s Arch Surg.
2021;407:797. https://doi.org/10.1007/s00423- 021- 02358- 8.
E. Tham et al.

11 Use of Fluorescence Guidance in Acute Care Surgery…
https://t.me/medicina_free
42. Daskalopoulou D, Kankam J, Plambeck J, Ambe PC, Zarras
K. Intraoperative real-time uorescence angiography with indocyanine
green for evaluation of intestinal viability during surgery for an incarcerated obturator hernia: a case report. Patient Saf Surg. 2018;12:24. https://
doi.org/10.1186/s13037- 018- 0173- 1.
43. Karampinis IA-O, Keese M, Jakob J, Stasiunaitis V, Gerken A, Attenberger
U, et al. Indocyanine green tissue angiography can reduce extended
bowel resections in acute mesenteric ischemia. J Gastrointest Surg.
2018;22(12):2117–24.
44. Wongkietkachorn A, Surakunprapha P, Winaikosol K, Waraasawapati S,
Chaiwiriyakul S, Eua-Angkanakul K, Wongkietkachorn N, et al.
Indocyanine green dye angiography as an adjunct to assess indeterminate
burn wounds: a prospective, multicentered, triple-blinded study. J Trauma
Acute Care Surg. 2019;86(5):823–8.
45. Miller G, Boman J, Shrier I, Gordon PH.Etiology of small bowel obstruction. Am J Surg. 2000;180(1):33–6. https://doi.org/10.1016/s0002-
9610(00)00407- 4.
46. Pekmezci S, Saribeyoglu K, Korman U.Guidelines for management of
small bowel obstruction. J Trauma. 2009;66(4):1262. https://doi.
org/10.1097/TA.0b013e318198d6a2.
47. Hernandez MC, Haddad NN, Cullinane DC, Yeh DD, Wydo S, Inaba K,
et al. The American Association for the Surgery of Trauma Severity
Grade is valid and generalizable in adhesive small bowel obstruction. J
Trauma Acute Care Surg. 2018;84(2):372.
48. Nakashima KA-O, Ryu S, Okamoto A, Hara K, Ishida K, Ito R, etal.
Intestinal blood ow evaluation using the indocyanine green uorescence
imaging method in a case of incarcerated obturator hernia: a case report.
Asian J Endosc Surg. 2021;14(3):565–9.
49. Nakashima K, Ryu S, Okamoto A, Hara K, Ishida K, Ito R, et al.
Usefulness of blood ow evaluation with indocyanine green uorescence
imaging during laparoscopic surgery for strangulated bowel obstruction:
a cohort study. Asian J Surg. 2021;45:867. https://doi.org/10.1016/j.asj-
sur.2021.08.020.
50. Urbanavičius L, Pattyn P, de Putte DV, Venskutonis D. How to assess
intestinal viability during surgery: a review of techniques. World J
Gastrointest Surg. 2011;3(5):59–69. https://doi.org/10.4240/wjgs.
v3.i5.59.
51. Choudhry AJ, Haddad NN, Rivera M, Morris DS, Zietlow SP, Schiller
HJ, etal. Medical malpractice in the management of small bowel obstruction: a 33-year review of case law. Surgery. 2016;160(4):1017–27. https://
doi.org/10.1016/j.surg.2016.06.031.
52. Mathew R.Caution warranted in use of indocyanine green uorescence
in laparoscopic evaluation of microcirculation in acute small bowel
obstruction. Color Dis. 2021;23(9):2472. https://doi.org/10.1111/
codi.15757.
333

334
https://t.me/medicina_free
53. Matsui A, Winer JH, Laurence RG, Frangioni JV.Predicting the survival
of experimental ischaemic small bowel using intraoperative near-infrared
uorescence angiography. Br J Surg. 2011;98(12):1725–34. https://doi.
org/10.1002/bjs.7698.
54. Iinuma Y, Hirayama Y, Yokoyama N, Otani T, Nitta K, Hashidate H, etal.
Intraoperative near-infrared indocyanine green uorescence angiography
(NIR-ICG AG) can predict delayed small bowel stricture after ischemic
intestinal injury: report of a case. J Pediatr Surg. 2013;48(5):1123–8.
https://doi.org/10.1016/j.jpedsurg.2013.03.067.
55. Trauma TAAftSo: AAST - trauma facts. 2022. https://www.aast.org/
resources/trauma- facts. Accessed 2022.
56. Kohno T, Miki T, Hayashi K. Choroidopathy after blunt trauma to the
eye: a uorescein and indocyanine green angiographic study. Am J
Ophthalmol. 1998;126(2):248–60. https://doi.org/10.1016/s0002-
9394(98)00153- 6.
57. A I, Abdelrahman H, El-Faramawy A, Mahmood I, Khoschnau S, AlNaimi N, etal. The use of Indocyanine green uorescent in patients with
abdominal trauma for better intraoperative decision-making and less
bowel anastomosis leak: case series. J Surg Case Rep.
2021;2021(6):rjab235. https://doi.org/10.1093/jscr/rjab235.
58. Kamolz L-P, Andel H, Auer T, Meissl G, Frey M.Evaluation of skin perfusion by use of indocyanine green video angiography: rational design
and planning of trauma surgery. J Trauma Acute Care Surg.
2006;61(3):635.
59. Ganau M, Iqbal M, Ligarotti GKI, Syrmos N.Breakthrough in the assessment of cerebral perfusion and vascular permeability after brain trauma
through the adoption of dynamic indocyanine green-enhanced nearinfrared spectroscopy. Quant Imaging Med Surg. 2020;10(11):2081–4.
https://doi.org/10.21037/qims- 20- 905.
60. Forcione M, Chiarelli AM, Davies DJ, Perpetuini D, Sawosz P, Merla A,
et al. Cerebral perfusion and blood–brain barrier assessment in brain
trauma using contrast-enhanced near-infrared spectroscopy with indocyanine green: a review. J Cereb Blood Flow Metab. 2020;40(8):1586–98.
https://doi.org/10.1177/0271678X20921973.
61. Pruimboom T, Schols RM, Van Kuijk SMJ, Van der Hulst R, Qiu
SS.Indocyanine green angiography for preventing postoperative mastectomy skin ap necrosis in immediate breast reconstruction. Cochrane
Database Syst Rev. 2020;4:CD013280. https://doi.org/10.1002/14651858.
CD013280.pub2.
62. Liu EH, Zhu SL, Hu J, Wong N, Farrokhyar F, Thoma A.Intraoperative
SPY reduces post-mastectomy skin ap complications: a systematic
review and meta-analysis. Plast Reconstr Surg Glob Open.
2019;7(4):e2060-e. https://doi.org/10.1097/GOX.0000000000002060.
63. Green JM 3rd, Sabino J, Fleming M, Valerio I.Intraoperative uorescence angiography: a review of applications and outcomes in war-related
E. Tham et al.

11 Use of Fluorescence Guidance in Acute Care Surgery…
https://t.me/medicina_free
trauma. Mil Med. 2015;180(3 Suppl):37–43. https://doi.org/10.7205/
MILMED- D- 14- 00632.
64. Wongkietkachorn A, Surakunprapha P, Winaikosol K, Waraasawapati S,
Chaiwiriyakul S, Eua-angkanakul K, etal. Indocyanine green dye angiography as an adjunct to assess indeterminate burn wounds: a prospective, multicentered, triple-blinded study. J Trauma Acute Care Surgery.
2019;86(5):823.
65. Wongkietkachorn A, Surakunprapha P, Jenwitheesuk K, Eua-Angkanakul
K, Winaikosol K, Punyavong P, etal. Indocyanine green angiography precise marking for indeterminate burn excision: a prospective, multicentered, double-blinded study. Plast Reconstr Surg Glob Open.
2021;9(4):e3538. https://doi.org/10.1097/GOX.0000000000003538.
66. Singh R, Rymer B, Youssef B, Lim J.The Morel-Lavallee lesion and its
management: a review of the literature. J Orthop. 2018;15(4):917–21.
https://doi.org/10.1016/j.jor.2018.08.032.
67. Sen CK, Ghatak S, Gnyawali SC, Roy S, Gordillo GM.Cutaneous imaging technologies in acute burn and chronic wound care. Plast Reconstr
Surg. 2016;138(3 Suppl):119S–28S. https://doi.org/10.1097/
PRS.0000000000002654.
68. Fang C, Wang K, Zeng C, Chi C, Shang W, Ye J, etal. Illuminating necrosis: from mechanistic exploration to preclinical application using uorescence molecular imaging with indocyanine green. Sci Rep. 2016;6:21013.
https://doi.org/10.1038/srep21013.
335

Use ofFluorescence Guidance
https://t.me/medicina_free
inPediatric Surgery
StefanScholz, HannahRinehardt,
RanjeetS.Kalsi, JillianC.Jacobson,
andSamirPandya
S. Scholz (*)
Division of Pediatric General and Thoracic Surgery, Department of
Surgery, University of Pittsburgh School of Medicine, UPMC Children’s
Hospital of Pittsburgh, Pittsburgh, PA, USA
e-mail: stefan.scholz@chp.edu
H. Rinehardt
Department of Surgery, University of Pittsburgh School of Medicine,
Pittsburgh, PA, USA
e-mail: Rinehardthn@upmc.edu
R. S. Kalsi
Division of Pediatric General and Thoracic Surgery, Department of
Surgery, University of Pittsburgh Medical Center/Children’s Hospital of
Pittsburgh, Pittsburgh, PA, USA
e-mail: rkalsi@myhealthsystem.org
J. C. Jacobson
Department of Surgery, UT Southwestern Medical Center,
Dallas, TX, USA
e-mail: Jillian.Jacobson@UTSouthwestern.edu
S. Pandya
Division of Pediatric Surgery, Department of Surgery, UT Southwestern
Medical Center, Dallas, TX, USA
e-mail: Samir.Pandya@UTSouthwestern.edu
12
© The Author(s), under exclusive license to Springer Nature
Switzerland AG 2023
N. Szoka et al. (eds.), The SAGES Manual of Fluorescence-Guided
Surgery, https://doi.org/10.1007/978-3-031-40685-0_12
337

338
https://t.me/medicina_free
S. Scholz et al.
Introduction
Fluorescence-guided surgery (FGS) is a medical imaging technique used to detect uorescently labeled structures during surgery. Camera systems that detect near-infrared (NIR) light not
visible to the human eye guide can provide information about
anatomy or tissue viability to the surgeon through real-time visualization in the operating eld. Indocyanine green (ICG) is the
only NIR uorescent agent currently approved for human use.
ICG is a safe, water-soluble compound that received FDA
approval in the 1950s. Despite the bright green color of the reagent
to the human eye, its use as a contrast agent is based on its robust
uorescence in the NIR range. Applications for ICG in the pediatric world are emerging. ICG can be used for arteriogram, venogram, or general perfusion assessment of tissues such as intestinal
perfusion before anastomosis or soft tissue pedicles or aps during plastic surgery. ICG is exclusively cleared by the liver and the
bile duct and is applied in uorescence cholangiography. When
administered as an intradermal, ICG gets protein-bound and conned to clearance via the lymphatic system, which is used to facilitate sentinel lymph node detection and biopsy.
Scientic Basis
Indocyanine green (ICG) is the only NIR uorescent agent currently approved for human use. ICG is a water-soluble, anionic,
amphiphilic tricarbocyanine (776 Da) that rapidly binds to plasma
proteins in the body. ICG was rst produced in 1955 by Kodak
Research Laboratories and received FDA approval for retinal
angiography in 1959. Historically, it has been used to measure
cardiac output and hepatic function and for retinal angiography.
After intravenous application, ICG remains largely protein-bound
in the intravascular space and is cleared exclusively by the liver.
ICG allows multiple uses due to its short intravascular half-life of
150 to 180 s. From the vasculature, ICG undergoes uptake by
hepatocytes and hepatic clearance. The dye can then be detected

12 Use ofFluorescence Guidance inPediatric Surgery
https://t.me/medicina_free
339
within minutes, peaks over the course of hours, and continues for
over a day after typical dosing. When administered intradermally,
ICG gets protein-bound and conned to clearance via the lymphatic system, which is used to facilitate sentinel lymph node
detection and biopsy.
ICG is excited using 780–810nm near-infrared (NIR) radiation and emits uorescence at 830–840nm. The specic wavelength of light emitted is visualized with a specialized camera
system [1]. The emitted uorescence can also be detected by a
photodynamic eye system or SPY portable handheld imager by
Stryker® (Kalamazoo, MI) in open operations. The da Vinci robot
(Intuitive Surgical®, Sunnyvale, CA) is equipped with a NIR camera called Firey Mode to visualize ICG uorescence. The halflife of ICG is 3–5min. It can be injected locally (for urologic or
lymphatic indications) or intravenously. The usual dose is 0.25–
0.5mg/kg and can be re-dosed with caution. ICG is safe with rare
adverse events. ICG should not be used in patients with an iodine
or shellsh allergy given the risk for anaphylaxis. IV ICG circulates in the bloodstream, is taken up by the liver, is excreted into
the bile, and then travels into the bowel loops. ICG can offer realtime identication of cancer tissues, insight into intestinal viability, and visualization of lymphatic structures and assist with ne
dissection around biliary structures to prevent injury. Fluorescence
visualizes ICG up to a depth of 5–10mm deep. Structures deeper
than 10mm cannot be visualized with ICG alone [1]. ICG offers
a great deal of promise for a variety of indications. In pediatric
patients, ICG is still an emerging technology with mounting evidence that will be reviewed here. A review of ICG in the pediatric
population was published in 2021in Frontiers in Pediatrics with
analysis of 64 articles including a total of 664 pediatric patients
[2]. There were no major adverse reactions reported from any of
the studies related to ICG, and the individual studies lacked power
due to low sample size. Additional details of some of the articles
will be discussed here. ICG has been shown to be safe in pediatric
patients, but more investigation is needed to evaluate the risks and
benets of using this technology in each operation where it may
offer utility.

340
https://t.me/medicina_free
S. Scholz et al.
Side Eects andComplications
Fluorescence-guided surgery (FGS) has been used across multiple elds with signicantly improved outcomes and decreased
complications. Throughout its history, ICG has maintained a high
safety index with a favorable side effect prole and severe complications are infrequent. Albeit rare, adverse reactions to ICG
have been reported throughout the literature. These include dyspnea, wheezing, cough, cyanosis, headache, urticaria, nausea,
pruritus, hypotension, cough, anxiety, laryngospasm, laryngobronchospasm, pulmonary congestion, facial edema, anaphylactic
shock, and death [3, 4]. More recently, Shafy et al. evaluated
intraoperative administration of ICG in 100 patients, who ranged
in age from 5 days old to 31 years old, with a median age of
12 years. Procedures included laparoscopic cholecystectomy,
colorectal surgery, sagittal anorectovaginourethroplasty, transanal
pull-through for Hirschsprung’s disease, perineal reconstruction,
exploratory laparotomy, and renal procedures. ICG was administered IV to all patients with a median dose of 1.1mL (2.5mg/mL
ICG solution). In this cohort, they found no hemodynamic or
respiratory alterations due to ICG usage. None of these patients
needed treatment with an anticholinergic drug, a vasoactive drug,
or a drug to treat bronchospasm [5]. Recent literature continues to
describe uncommon adverse reactions such as anaphylactic shock
to ICG [6, 7]. ICG contains sodium iodide and there are rare
reports about anaphylaxis or urticarial reactions (1:10,000, as
reported by the manufacturer). Iodine uptake studies should not
be performed for a week following its use. Lastly, there is no data
to support or contraindicate use in pregnant or nursing mothers.
Overall, the present incidence of side effects and complications of ICG in the pediatric population is low, and FGS is an asset
to the surgeon.
Dosing andTiming Guide forPediatric Applications
Summary of doses and timing of indocyanine green by indication.
Соседние файлы в папке @xirurgi_2025
