Добавил:
kiopkiopkiop18@yandex.ru t.me/Prokururor I Вовсе не секретарь, но почту проверяю Опубликованный материал нарушает ваши авторские права? Сообщите нам.
Вуз: Предмет: Файл:

Ординатура / Хирургия / @xirurgi_2025 / @xirurgi_2025 - 715 - файл

.pdf
Скачиваний:
0
Добавлен:
29.08.2026
Размер:
16 Мб
Скачать
330
https://t.me/medicina_free
9. Holm C, Mayr M, Höfter E, Becker A, Pfeiffer UJ, Pfeiffer Mühlbauer W. Intraoperative evaluation of skin-ap viability using laser-induced uorescence of indocyanine green. Br J Plast Surg. 2002;55(8):635–44.
10. Wirts CW, Cantarow A.A study of the excretion of bromsulphthalein in the bile. Am J Dig Dis. 1942;9(3):101–6. https://doi.org/10.1007/
BF02996980.
11. Paumgartner G, Vasella DL, Herz R, Reichen J, Preisig R.Hepatic extrac­tion of taurocholate and indocyanine green in patients with liver disease (author’s transl). Z Gastroenterol. 1979;17(11):753–61.
12. Rowell LB, Blackmon JR, Bruce RA.Indocyanine green clearance and estimated hepatic blood ow during mild to maximal exercise in upright man. J Clin Invest. 1964;43:1677–90. https://doi.org/10.1172/JCI105043.
13. Marano A, Priora F, Lenti LM, Ravazzoni F, Quarati R, Spinoglio G.Application of uorescence in robotic general surgery: review of the literature and state of the art. World J Surg. 2013;37(12):2800–11. https://
doi.org/10.1007/s00268- 013- 2066- x.
14. Blythe J, Herrmann E, Faust D, Falk S, Edwards-Lehr T, Stockhausen F, etal. Acute cholecystitis- a cohort study in a real-world clinical setting (REWO study, NCT02796443). Pragmat Obs Res. 2018;9:69–75. https://
doi.org/10.2147/POR.S169255.
15. Mangieri CW, Hendren BP, Strode MA, Bandera BC, Faler BJ.Bile duct injuries (BDI) in the advanced laparoscopic cholecystectomy era. Surg Endosc. 2019;33(3):724–30. https://doi.org/10.1007/s00464- 018-
6333- 7.
16. Madni TD, Nakonezny PA, Imran JB, Taveras L, Cunningham HB, Vela R, etal. A comparison of cholecystitis grading scales. J Trauma Acute Care Surg. 2019;86(3):471–8. https://doi.org/10.1097/
TA.0000000000002125.
17. Buddingh KT, Nieuwenhuijs VB, van Buuren L, Hulscher JB, de Jong JS, van Dam GM.Intraoperative assessment of biliary anatomy for preven­tion of bile duct injury: a review of current and future patient safety inter­ventions. Surg Endosc. 2011;25(8):2449–61. https://doi.org/10.1007/
s00464- 011- 1639- 8.
18. Flum DR, Flowers C, Veenstra DL.A cost-effectiveness analysis of intra­operative cholangiography in the prevention of bile duct injury during laparoscopic cholecystectomy. J Am Coll Surg. 2003;196(3):385–93.
https://doi.org/10.1016/S1072- 7515(02)01806- 9.
19. Vlek SL, van Dam DA, Rubinstein SM, de Lange-de Klerk ESM, Schoonmade LJ, Tuynman JB, etal. Biliary tract visualization using near­infrared imaging with indocyanine green during laparoscopic cholecys­tectomy: results of a systematic review. Surg Endosc. 2017;31(7):2731–42.
https://doi.org/10.1007/s00464- 016- 5318- 7.
20. Aoki T, Murakami M, Yasuda D, Shimizu Y, Kusano T, Matsuda K, etal. Intraoperative uorescent imaging using indocyanine green for liver
E. Tham et al.
11 Use of Fluorescence Guidance in Acute Care Surgery…
https://t.me/medicina_free
mapping and cholangiography. J Hepatobiliary Pancreat Sci. 2010;17(5):590–4. https://doi.org/10.1007/s00534- 009- 0197- 0.
21. Osayi SN, Wendling MR, Drosdeck JM, Chaudhry UI, Perry KA, Noria SF, etal. Near-infrared uorescent cholangiography facilitates identication of biliary anatomy during laparoscopic cholecystec­tomy. Surg Endosc. 2015;29(2):368–75. https://doi.org/10.1007/
s00464- 014- 3677- 5.
22. Bronikowski D, Lombardo D, DeLa OC, Szoka N.Robotic subtotal cho­lecystectomy in a geriatric acute care surgery patient with super obesity. Case Rep Surg. 2021;2021:9992622. https://doi.
org/10.1155/2021/9992622.
23. Ambe PC, Plambeck J, Fernandez-Jesberg V, Zarras K.The role of indo­cyanine green uoroscopy for intraoperative bile duct visualization dur­ing laparoscopic cholecystectomy: an observational cohort study in 70 patients. Patient Saf Surg. 2019;13:2. https://doi.org/10.1186/s13037-
019- 0182- 8.
24. Broderick RC, Lee AA-O, Cheverie JN, Zhao B, Blitzer RR, Patel RJ, et al. Fluorescent cholangiography signicantly improves patient out­comes for laparoscopic cholecystectomy. Surg Endosc. 2021;35(10):5729–39.
25. Ankersmit M, van Dam DA, van Rijswijk AS, van den Heuvel B, Tuynman JB, Meijerink W.Fluorescent imaging with indocyanine green during laparoscopic cholecystectomy in patients at increased risk of bile duct injury. Surg Innov. 2017;24(3):245–52. https://doi.
org/10.1177/1553350617690309.
26. Boogerd LSF, Handgraaf HJM, Huurman VAL, Lam HD, Mieog JSD, van der Made WJ, etal. The best approach for laparoscopic uorescence cholangiography: overview of the literature and optimization of dose and dosing time. Surg Innov. 2017;24(4):386–96. https://doi.
org/10.1177/1553350617702311.
27. Verbeek FP, Schaafsma BE, Tummers QR, van der Vorst JR, van der Made WJ, Baeten CI, etal. Optimization of near-infrared uorescence cholangiography for open and laparoscopic surgery. Surg Endosc. 2014;28(4):1076–82. https://doi.org/10.1007/s00464- 013- 3305- 9.
28. Strasberg SM, Brunt LM.Rationale and use of the critical view of safety in laparoscopic cholecystectomy. J Am Coll Surg. 2010;211(1):132–8.
29. Lim SH, Tan HTA, Shelat VG. Comparison of indocyanine green dye uorescent cholangiography with intra-operative cholangiography in laparoscopic cholecystectomy: a meta-analysis. Surg Endosc. 2021;35(4):1511–20. https://doi.org/10.1007/s00464- 020- 08164- 5.
30. Turcotte J, Leydorf SD, Ali M, Feather C, Klune JR.Indocyanine green does not decrease the need for bail-out operation in an acute care surgery population. Surgery. 2021;169(2):227–31. https://doi.org/10.1016/j.
surg.2020.05.045.
331
332
https://t.me/medicina_free
31. Bryski MG, Frenzel Sulyok LG, Kaplan L, Singhal S, Keating JJ.Techniques for intraoperative evaluation of bowel viability in mesen­teric ischemia: a review. Am J Surg. 2020;220(2):309–15. https://doi.
org/10.1016/j.amjsurg.2020.01.042.
32. Tilsed JV, Casamassima A, Kurihara H, Mariani D, Martinez I, Pereira J, et al. ESTES guidelines: acute mesenteric ischaemia. Eur J Trauma Emerg Surg. 2016;42(2):253–70. https://doi.org/10.1007/s00068- 016-
0634- 0.
33. Adaba F, Askari A, Dastur J, Patel A, Gabe SM, Vaizey CJ, etal. Mortality after acute primary mesenteric infarction: a systematic review and meta­analysis of observational studies. Color Dis. 2015;17(7):566–77. https://
doi.org/10.1111/codi.12938.
34. Szoka N, Kahn M. Acute-on-chronic mesenteric ischemia: the use of uorescence guidance to diagnose a nonsurvivable injury. Case Rep Surg. 2022;2022:5459774. https://doi.org/10.1155/2022/5459774.
35. Son GM, Kwon MS, Kim Y, Kim J, Kim SH, Lee JW.Quantitative analy­sis of colon perfusion pattern using indocyanine green (ICG) angiogra­phy in laparoscopic colorectal surgery. Surg Endosc. 2019;33(5):1640–9.
https://doi.org/10.1007/s00464- 018- 6439- y.
36. Mehdorn M, Ebel S, Kohler H, Gockel I, Jansen-Winkeln B.Hyperspectral imaging and indocyanine green uorescence angiography in acute mes­enteric ischemia: a case report on how to visualize intestinal perfusion. Int J Surg Case Rep. 2021;82:105853. https://doi.org/10.1016/j.
ijscr.2021.105853.
37. Nakagawa Y, Kobayashi K, Kuwabara S, Shibuya H, Nishimaki T.Use of indocyanine green uorescence imaging to determine the area of bowel resection in non-occlusive mesenteric ischemia: a case report. Int J Surg Case Rep. 2018;51:352–7. https://doi.org/10.1016/j.ijscr.2018.09.024.
38. Irie T, Matsutani T, Hagiwara N, Nomura T, Fujita I, Kanazawa Y, etal. Successful treatment of non-occlusive mesenteric ischemia with indocya­nine green uorescence and open-abdomen management. Clin J Gastroenterol. 2017;10(6):514–8. https://doi.org/10.1007/s12328- 017-
0779- 3.
39. Nitori N, Deguchi T, Kubota K, Yoshida M, Kato A, Kojima M, etal. Successful treatment of non-occlusive mesenteric ischemia (NOMI) using the HyperEye Medical System™ for intraoperative visualization of the mesenteric and bowel circulation: report of a case. Surg Today. 2014;44(2):359–62. https://doi.org/10.1007/s00595- 013- 0503- y.
40. Guerra F, Coletta D, Greco PA, Eugeni E, Patriti A.The use of indocya­nine green uorescence to dene bowel microcirculation during laparo­scopic surgery for acute small bowel obstruction. Color Dis. 2021;23(8):2189–94. https://doi.org/10.1111/codi.15680.
41. Ryu S, Hara K, Goto K, Okamoto A, Kitagawa T, Marukuchi R, etal. Fluorescence angiography vs. direct palpation for bowel viability evalua­tion with strangulated bowel obstruction. Langenbeck’s Arch Surg. 2021;407:797. https://doi.org/10.1007/s00423- 021- 02358- 8.
E. Tham et al.
11 Use of Fluorescence Guidance in Acute Care Surgery…
https://t.me/medicina_free
42. Daskalopoulou D, Kankam J, Plambeck J, Ambe PC, Zarras K. Intraoperative real-time uorescence angiography with indocyanine green for evaluation of intestinal viability during surgery for an incarcer­ated obturator hernia: a case report. Patient Saf Surg. 2018;12:24. https://
doi.org/10.1186/s13037- 018- 0173- 1.
43. Karampinis IA-O, Keese M, Jakob J, Stasiunaitis V, Gerken A, Attenberger U, et al. Indocyanine green tissue angiography can reduce extended bowel resections in acute mesenteric ischemia. J Gastrointest Surg. 2018;22(12):2117–24.
44. Wongkietkachorn A, Surakunprapha P, Winaikosol K, Waraasawapati S, Chaiwiriyakul S, Eua-Angkanakul K, Wongkietkachorn N, et al. Indocyanine green dye angiography as an adjunct to assess indeterminate burn wounds: a prospective, multicentered, triple-blinded study. J Trauma Acute Care Surg. 2019;86(5):823–8.
45. Miller G, Boman J, Shrier I, Gordon PH.Etiology of small bowel obstruc­tion. Am J Surg. 2000;180(1):33–6. https://doi.org/10.1016/s0002-
9610(00)00407- 4.
46. Pekmezci S, Saribeyoglu K, Korman U.Guidelines for management of small bowel obstruction. J Trauma. 2009;66(4):1262. https://doi.
org/10.1097/TA.0b013e318198d6a2.
47. Hernandez MC, Haddad NN, Cullinane DC, Yeh DD, Wydo S, Inaba K, et al. The American Association for the Surgery of Trauma Severity Grade is valid and generalizable in adhesive small bowel obstruction. J Trauma Acute Care Surg. 2018;84(2):372.
48. Nakashima KA-O, Ryu S, Okamoto A, Hara K, Ishida K, Ito R, etal. Intestinal blood ow evaluation using the indocyanine green uorescence imaging method in a case of incarcerated obturator hernia: a case report. Asian J Endosc Surg. 2021;14(3):565–9.
49. Nakashima K, Ryu S, Okamoto A, Hara K, Ishida K, Ito R, et al. Usefulness of blood ow evaluation with indocyanine green uorescence imaging during laparoscopic surgery for strangulated bowel obstruction: a cohort study. Asian J Surg. 2021;45:867. https://doi.org/10.1016/j.asj-
sur.2021.08.020.
50. Urbanavičius L, Pattyn P, de Putte DV, Venskutonis D. How to assess intestinal viability during surgery: a review of techniques. World J Gastrointest Surg. 2011;3(5):59–69. https://doi.org/10.4240/wjgs.
v3.i5.59.
51. Choudhry AJ, Haddad NN, Rivera M, Morris DS, Zietlow SP, Schiller HJ, etal. Medical malpractice in the management of small bowel obstruc­tion: a 33-year review of case law. Surgery. 2016;160(4):1017–27. https://
doi.org/10.1016/j.surg.2016.06.031.
52. Mathew R.Caution warranted in use of indocyanine green uorescence in laparoscopic evaluation of microcirculation in acute small bowel obstruction. Color Dis. 2021;23(9):2472. https://doi.org/10.1111/
codi.15757.
333
334
https://t.me/medicina_free
53. Matsui A, Winer JH, Laurence RG, Frangioni JV.Predicting the survival of experimental ischaemic small bowel using intraoperative near-infrared uorescence angiography. Br J Surg. 2011;98(12):1725–34. https://doi.
org/10.1002/bjs.7698.
54. Iinuma Y, Hirayama Y, Yokoyama N, Otani T, Nitta K, Hashidate H, etal. Intraoperative near-infrared indocyanine green uorescence angiography (NIR-ICG AG) can predict delayed small bowel stricture after ischemic intestinal injury: report of a case. J Pediatr Surg. 2013;48(5):1123–8.
https://doi.org/10.1016/j.jpedsurg.2013.03.067.
55. Trauma TAAftSo: AAST - trauma facts. 2022. https://www.aast.org/
resources/trauma- facts. Accessed 2022.
56. Kohno T, Miki T, Hayashi K. Choroidopathy after blunt trauma to the eye: a uorescein and indocyanine green angiographic study. Am J Ophthalmol. 1998;126(2):248–60. https://doi.org/10.1016/s0002-
9394(98)00153- 6.
57. A I, Abdelrahman H, El-Faramawy A, Mahmood I, Khoschnau S, Al­Naimi N, etal. The use of Indocyanine green uorescent in patients with abdominal trauma for better intraoperative decision-making and less bowel anastomosis leak: case series. J Surg Case Rep. 2021;2021(6):rjab235. https://doi.org/10.1093/jscr/rjab235.
58. Kamolz L-P, Andel H, Auer T, Meissl G, Frey M.Evaluation of skin per­fusion by use of indocyanine green video angiography: rational design and planning of trauma surgery. J Trauma Acute Care Surg. 2006;61(3):635.
59. Ganau M, Iqbal M, Ligarotti GKI, Syrmos N.Breakthrough in the assess­ment of cerebral perfusion and vascular permeability after brain trauma through the adoption of dynamic indocyanine green-enhanced near­infrared spectroscopy. Quant Imaging Med Surg. 2020;10(11):2081–4.
https://doi.org/10.21037/qims- 20- 905.
60. Forcione M, Chiarelli AM, Davies DJ, Perpetuini D, Sawosz P, Merla A, et al. Cerebral perfusion and blood–brain barrier assessment in brain trauma using contrast-enhanced near-infrared spectroscopy with indocy­anine green: a review. J Cereb Blood Flow Metab. 2020;40(8):1586–98.
https://doi.org/10.1177/0271678X20921973.
61. Pruimboom T, Schols RM, Van Kuijk SMJ, Van der Hulst R, Qiu SS.Indocyanine green angiography for preventing postoperative mastec­tomy skin ap necrosis in immediate breast reconstruction. Cochrane Database Syst Rev. 2020;4:CD013280. https://doi.org/10.1002/14651858.
CD013280.pub2.
62. Liu EH, Zhu SL, Hu J, Wong N, Farrokhyar F, Thoma A.Intraoperative SPY reduces post-mastectomy skin ap complications: a systematic review and meta-analysis. Plast Reconstr Surg Glob Open. 2019;7(4):e2060-e. https://doi.org/10.1097/GOX.0000000000002060.
63. Green JM 3rd, Sabino J, Fleming M, Valerio I.Intraoperative uores­cence angiography: a review of applications and outcomes in war-related
E. Tham et al.
11 Use of Fluorescence Guidance in Acute Care Surgery…
https://t.me/medicina_free
trauma. Mil Med. 2015;180(3 Suppl):37–43. https://doi.org/10.7205/
MILMED- D- 14- 00632.
64. Wongkietkachorn A, Surakunprapha P, Winaikosol K, Waraasawapati S, Chaiwiriyakul S, Eua-angkanakul K, etal. Indocyanine green dye angi­ography as an adjunct to assess indeterminate burn wounds: a prospec­tive, multicentered, triple-blinded study. J Trauma Acute Care Surgery. 2019;86(5):823.
65. Wongkietkachorn A, Surakunprapha P, Jenwitheesuk K, Eua-Angkanakul K, Winaikosol K, Punyavong P, etal. Indocyanine green angiography pre­cise marking for indeterminate burn excision: a prospective, multi­centered, double-blinded study. Plast Reconstr Surg Glob Open. 2021;9(4):e3538. https://doi.org/10.1097/GOX.0000000000003538.
66. Singh R, Rymer B, Youssef B, Lim J.The Morel-Lavallee lesion and its management: a review of the literature. J Orthop. 2018;15(4):917–21.
https://doi.org/10.1016/j.jor.2018.08.032.
67. Sen CK, Ghatak S, Gnyawali SC, Roy S, Gordillo GM.Cutaneous imag­ing technologies in acute burn and chronic wound care. Plast Reconstr Surg. 2016;138(3 Suppl):119S–28S. https://doi.org/10.1097/
PRS.0000000000002654.
68. Fang C, Wang K, Zeng C, Chi C, Shang W, Ye J, etal. Illuminating necro­sis: from mechanistic exploration to preclinical application using uores­cence molecular imaging with indocyanine green. Sci Rep. 2016;6:21013.
https://doi.org/10.1038/srep21013.
335
Use ofFluorescence Guidance
https://t.me/medicina_free
inPediatric Surgery
StefanScholz, HannahRinehardt, RanjeetS.Kalsi, JillianC.Jacobson, andSamirPandya
S. Scholz (*) Division of Pediatric General and Thoracic Surgery, Department of Surgery, University of Pittsburgh School of Medicine, UPMC Children’s Hospital of Pittsburgh, Pittsburgh, PA, USA e-mail: stefan.scholz@chp.edu
H. Rinehardt Department of Surgery, University of Pittsburgh School of Medicine, Pittsburgh, PA, USA e-mail: Rinehardthn@upmc.edu
R. S. Kalsi Division of Pediatric General and Thoracic Surgery, Department of Surgery, University of Pittsburgh Medical Center/Children’s Hospital of Pittsburgh, Pittsburgh, PA, USA e-mail: rkalsi@myhealthsystem.org
J. C. Jacobson Department of Surgery, UT Southwestern Medical Center, Dallas, TX, USA e-mail: Jillian.Jacobson@UTSouthwestern.edu
S. Pandya Division of Pediatric Surgery, Department of Surgery, UT Southwestern Medical Center, Dallas, TX, USA e-mail: Samir.Pandya@UTSouthwestern.edu
12
© The Author(s), under exclusive license to Springer Nature Switzerland AG 2023 N. Szoka et al. (eds.), The SAGES Manual of Fluorescence-Guided Surgery, https://doi.org/10.1007/978-3-031-40685-0_12
337
338
https://t.me/medicina_free
S. Scholz et al.
Introduction
Fluorescence-guided surgery (FGS) is a medical imaging tech­nique used to detect uorescently labeled structures during sur­gery. Camera systems that detect near-infrared (NIR) light not visible to the human eye guide can provide information about anatomy or tissue viability to the surgeon through real-time visu­alization in the operating eld. Indocyanine green (ICG) is the only NIR uorescent agent currently approved for human use. ICG is a safe, water-soluble compound that received FDA approval in the 1950s. Despite the bright green color of the reagent to the human eye, its use as a contrast agent is based on its robust uorescence in the NIR range. Applications for ICG in the pediat­ric world are emerging. ICG can be used for arteriogram, veno­gram, or general perfusion assessment of tissues such as intestinal perfusion before anastomosis or soft tissue pedicles or aps dur­ing plastic surgery. ICG is exclusively cleared by the liver and the bile duct and is applied in uorescence cholangiography. When administered as an intradermal, ICG gets protein-bound and con­ned to clearance via the lymphatic system, which is used to facil­itate sentinel lymph node detection and biopsy.
Scientic Basis
Indocyanine green (ICG) is the only NIR uorescent agent cur­rently approved for human use. ICG is a water-soluble, anionic, amphiphilic tricarbocyanine (776 Da) that rapidly binds to plasma proteins in the body. ICG was rst produced in 1955 by Kodak Research Laboratories and received FDA approval for retinal angiography in 1959. Historically, it has been used to measure cardiac output and hepatic function and for retinal angiography. After intravenous application, ICG remains largely protein-bound in the intravascular space and is cleared exclusively by the liver. ICG allows multiple uses due to its short intravascular half-life of 150 to 180 s. From the vasculature, ICG undergoes uptake by hepatocytes and hepatic clearance. The dye can then be detected
12 Use ofFluorescence Guidance inPediatric Surgery
https://t.me/medicina_free
339
within minutes, peaks over the course of hours, and continues for over a day after typical dosing. When administered intradermally, ICG gets protein-bound and conned to clearance via the lym­phatic system, which is used to facilitate sentinel lymph node detection and biopsy.
ICG is excited using 780–810nm near-infrared (NIR) radia­tion and emits uorescence at 830–840nm. The specic wave­length of light emitted is visualized with a specialized camera system [1]. The emitted uorescence can also be detected by a photodynamic eye system or SPY portable handheld imager by Stryker® (Kalamazoo, MI) in open operations. The da Vinci robot (Intuitive Surgical®, Sunnyvale, CA) is equipped with a NIR cam­era called Firey Mode to visualize ICG uorescence. The half­life of ICG is 3–5min. It can be injected locally (for urologic or lymphatic indications) or intravenously. The usual dose is 0.25–
0.5mg/kg and can be re-dosed with caution. ICG is safe with rare adverse events. ICG should not be used in patients with an iodine or shellsh allergy given the risk for anaphylaxis. IV ICG circu­lates in the bloodstream, is taken up by the liver, is excreted into the bile, and then travels into the bowel loops. ICG can offer real­time identication of cancer tissues, insight into intestinal viabil­ity, and visualization of lymphatic structures and assist with ne dissection around biliary structures to prevent injury. Fluorescence visualizes ICG up to a depth of 5–10mm deep. Structures deeper than 10mm cannot be visualized with ICG alone [1]. ICG offers a great deal of promise for a variety of indications. In pediatric patients, ICG is still an emerging technology with mounting evi­dence that will be reviewed here. A review of ICG in the pediatric population was published in 2021in Frontiers in Pediatrics with analysis of 64 articles including a total of 664 pediatric patients [2]. There were no major adverse reactions reported from any of the studies related to ICG, and the individual studies lacked power due to low sample size. Additional details of some of the articles will be discussed here. ICG has been shown to be safe in pediatric patients, but more investigation is needed to evaluate the risks and benets of using this technology in each operation where it may offer utility.
340
https://t.me/medicina_free
S. Scholz et al.
Side Eects andComplications
Fluorescence-guided surgery (FGS) has been used across multi­ple elds with signicantly improved outcomes and decreased complications. Throughout its history, ICG has maintained a high safety index with a favorable side effect prole and severe com­plications are infrequent. Albeit rare, adverse reactions to ICG have been reported throughout the literature. These include dys­pnea, wheezing, cough, cyanosis, headache, urticaria, nausea, pruritus, hypotension, cough, anxiety, laryngospasm, laryngo­bronchospasm, pulmonary congestion, facial edema, anaphylactic shock, and death [3, 4]. More recently, Shafy et al. evaluated intraoperative administration of ICG in 100 patients, who ranged in age from 5 days old to 31 years old, with a median age of 12 years. Procedures included laparoscopic cholecystectomy, colorectal surgery, sagittal anorectovaginourethroplasty, transanal pull-through for Hirschsprung’s disease, perineal reconstruction, exploratory laparotomy, and renal procedures. ICG was adminis­tered IV to all patients with a median dose of 1.1mL (2.5mg/mL ICG solution). In this cohort, they found no hemodynamic or respiratory alterations due to ICG usage. None of these patients needed treatment with an anticholinergic drug, a vasoactive drug, or a drug to treat bronchospasm [5]. Recent literature continues to describe uncommon adverse reactions such as anaphylactic shock to ICG [6, 7]. ICG contains sodium iodide and there are rare reports about anaphylaxis or urticarial reactions (1:10,000, as reported by the manufacturer). Iodine uptake studies should not be performed for a week following its use. Lastly, there is no data to support or contraindicate use in pregnant or nursing mothers.
Overall, the present incidence of side effects and complica­tions of ICG in the pediatric population is low, and FGS is an asset to the surgeon.
Dosing andTiming Guide forPediatric Applications
Summary of doses and timing of indocyanine green by indication.
Соседние файлы в папке @xirurgi_2025