The Role of Simulators in Safe Adoption of Endoscopic Mitral Valve Surgery 279
Fig. 1 Final version of the simulator. A and B,Viewofthe assembled simulator. C and D, Feedback system. E and F, Magnetic,papillary muscles mounted in the 3-dimensional– printed ventricle. Reprinted from The Journal of Thoracic
efcient learning without feedback [16]. To cre­ate a learning platform for mitral valve surgery, one should receive objective and reproducible feedback to gain prociency and become acquainted with the procedural steps. Moreover, procedures as MIMVS are composed of many layers of complexity. Four cameras around the
and Cardiovascular Surgery, Volume 157, Nia, P. S., Daemen, J. H., & Maessen, J. G, Development of a high­delity minimally invasive mitral valve surgery simulator, 1567–1574, 2019, with permission from Elsevier [18]
silicone valve and an edge detectable algorithm to calculate the suture width and depth were installed [18]. This way, the simulator provides a metric-based performance feedback about sutur­ing depth and length. The idea behind having feedback about suturing is not to mimic the exact suture depth or width of an actual operation. The
280 L. Aerts and P. Sardari Nia
Данная книга находится в списке для перевода на русский язык сайта https://meduniver.com/
objective is to provide a platform on which a surgeon could develop full control over the long­shafted instruments in way that any pre-setted suturing could be realized. Additional to this, the metric-based feedback gives objective scori ng for assessments of trainees.
Especially in the beginning, expert feedback is necessary for the most effective use of the simulator. The combination of formative and objective feedback is the basis for long- term knowledge retention.
3 Patient Specific 3D Mitral Valve
Modelling for Training Purpose
In the simulation-based training, we use 3D­modelling and printing of the mitral valve to interact with different anatomy and pathology. We developed a dedicated process to replicate any mitral valve pathology in 3D-printed silicone replica from TEE. This process can roughly be divided into six major steps, namely data acqui­sition, data conversion, mesh renement, rapid prototyping, negative mould fabrication and casting (Fig. 2).
Mandatory components in 3D-modeling are clinical imaging modal ities. Imaging data is obtained by 3D transoesophageal echocardiog­raphy (TOE). These high-quality volumetric 3D images are convert ed into Cartesian Digital Imaging Communications in Medicine (DICOM) format. The mitral valve annulus and the leaets
are reconstructed. Because of technical difcul­ties it is not yet possible to reconstruct the sub­valvular apparatus. The mitral valve is reconstructed in the mid-systolic phase to reproduce the coaptation defect. The data is exported to a Surface Tessellation Language (STL) le, the standard format for 3D printing.
In the third step, mesh renements are con­ducted in MeshLab (Istituto di Scienza e Tec­nologie dellinformazione, Pisa, Italy) and subsequently manufactured into a model on 1:1 scale. Printing is accomplished by selective laser stereolithography, which is the golden standard in 3D bio model production. The model is casted in a deformable silicone to mimic true-to-nature suture experience by negative mould fabrication and silicone-casting [19].
4 Clinical Applications
In generic terms, simulation-based training refers to an articial representation of a realistic process to achieve educational goals throughout experi­ential learning. The acquisition of many technical and nontechnical skills is moving outside the operative theatre, using simulation-based train­ing. Achieving surgical competence in complex surgery, such as MIMVS, requires surgical volume.
The use of high-delity simulators in MIMVS can serve different purposes. It can be used for training surgeons, for preprocedural planning and
Fig. 2 Step by step process for solid and silicone 3D print fabrication. Reprinted with permission from The Journal of Visualized Surgery, https://doi.org/10.21037/jovs.2019.05.01 [25]
The Role of Simulators in Safe Adoption of Endoscopic Mitral Valve Surgery 281
for assessment and certication of skills. Fur­thermore, the simulator can also be used for product development, testing new instruments, rening, and developing new surgical techniques.
For example, by using the simulator, a sutur­ing map was designed after identifying the most effective suturing sequences and techniques with minimal tissue manipulation and maximal visual experience (Fig. 3). Additionally, it was evalu­ated successfully in the operating room and used in course to evaluate its teachiblity [24].
Furthermore, we conducted a study to develop a process for modelling and 3D- printing for preoperative planning and procedural simulation by analyzing 10 prospective patients with dif­ferent mitral valve pathologies. This study demonstrated the additional benet of the designed and printed models, which can be implanted in the simulator to improve preopera­tive planning and simulation of complex surg­eries for training purposes. The case below is to illustrate the process [19].
Mitral valve repair for posterior leaet prolapse and annular dilatation
A 63-year-old man presented on the outpatient clinic with severe mitral valve regurgitation based on posterior leaet prolapse and annular dilatation. The patient was discussed in our multidisciplinary consultation and was found eligible for mitral valve surgery. A normal right and left ventricular function with an end diastolic dimeter of 58 mm was seen on transthoracic echocardiography. Transoesophageal echocar­diography showed severe mitral valve regurgi­tation with an eccentric jet due to P2 prolapse with chordal rupture. Additionally, there was a mild P1 prolapse, a minimal trace of tricuspid valve insufciency and no signs of aortic insuf­ciency. Computed tomography showed no contraindications for peripheral cannulation and the patient was accepted for MIMVS. A silicone mitral valve was created by 3D modelling and printing, and eventually mounted in the simulator for in vitro preoperative planning (Fig. 4).
Fig. 3 Suturing map. A: Reversed forehand position, B: Backhand position, C: Reversed backhand position, D: Forehand position. Images provided courtesy of The
Multimedia Manual of Cardio-Thoracic Surgery https://
mmcts.org/tutorial/1041 [24].
282 L. Aerts and P. Sardari Nia
Данная книга находится в списке для перевода на русский язык сайта https://meduniver.com/
Fig. 4 Silicone model showing posterior leaet pSilicone model showing rolapse and annular dilatation. Reprinted with permission from The Journal of Visualized Surgery, https://doi.org/10.21037/jovs.2019.05.01 [25]
During the simulation 2 neochordae were placed in the P2 segment. 1 neochord was placed in the P1 segment and another one was placed in the P3 segment. To stabilize the mitral valve annulus and the repair, a semi-rigid annuloplasty ring (size 34) was tted into place (See Video 1). The patient was than operated the next day simulating the operation done in the simulator with successful result [25].
Structural training
Simulation based training may help residents to achieve prociency in basic and more complex surgical skills, while practicing surgeons can develop new strategies or learn new techniques more swiftly. This type of education is already implemented in laparoscopic surgery and has
simulators but how we should implement simu­lation-based training.
First, we shoul d acknowledge that simulation­based training is no substitute for traditional apprenticeship training. We showed that the high­delity minimally invasive mitral valve surgery simulator is a valuable tool for the development and assessment of endoscopic mitral repair skills. Subsequently we designed an air-pilot training concept, through European Association for Car­diothoracic Surgery (EACTS), Endoscopic Mitral Valve Repair Course. This 2-day course design was based on the following basic learning objectives (Fig. 5).
1. Awareness
2. Acquiring theoretical knowledge
3. Acquiring endoscopic skills. been proven to be effective by reducing the learning curve in vivo procedures [8]. The question is no longer if we should practice on
Firstly, it is important for the participants to
get introduced to the mitral valve simulator and
The Role of Simulators in Safe Adoption of Endoscopic Mitral Valve Surgery 283
Video 1 Mitral valve repair for posterior leaet prolapse and annular dilatation. Available online:
http://www.asvide.com/article/view/32377. Reprinted with permission from The Journal of Visualized Surgery, https://doi.org/10.21037/jovs.2018.09.07 [26](▶ https://doi.org/10.1007/000-a8g)
Fig. 5 Overview of the philosophy of simulation based training and its inclusion in the endoscopic mitral valve course in our centre. 3D: three-dimensional. Reprinted from Interactive CardioVascular and Thoracic Surgery, Volume 30, Issue 5, Peyman Sardari Nia, Samuel Heuts,
Jean H T Daemen, Jules R Olsthoorn, W Randolph Chitwood, Jr, Jos G Maessen, The EACTS simulation­based training course for endoscopic mitral valve repair: an air-pilot training concept in action, 691–698, 2020, with permission from Elsevier [26].
284 L. Aerts and P. Sardari Nia
Данная книга находится в списке для перевода на русский язык сайта https://meduniver.com/
Fig. 6 Simulation based training for endoscopic mitral valve repair: an air-pilot training concept in action. Reprinted from Interactive CardioVascular and Thoracic Surgery, Volume 30, Issue 5, Peyman Sardari Nia, Samuel Heuts, Jean H T Daemen, Jules R Olsthoorn, W
create awareness for the demanding skills, knowledge, organization and teamwork before starting the endoscopic mitral valve programme. Additional to this, one should focus on acquiring the complemental theoretical knowledge and technical skills (for example the use of long­shafted instruments and the use of video assis­tance) for simulation-based training on MIMVS.
One hundred two participants completed the full endoscopic mitral valve programme between February 2016 and September 2018. 83 (83.3%) participants were staff/attending surgeons, 12 (11.8%) participants had nished residency and 5 (4.9%) participants were residents.
The course started with theoretical and tech­nical skills pre-assessment on the simulators. During the course formative feedback was pro­vided by an expert on MIMVS and metric-based feedback was provided by the simulator. At the end of the course there was a theoretical and technical skills post-assessment and a course evaluation with follow up.
The study showed signicantly higher theo­retical knowledge of endoscopic mitral valve surgery after completion of the mitral valve programme compared to before the training
Randolph Chitwood, Jr, Jos G Maessen, The EACTS simulation-based training course for endoscopic mitral valve repair: an air-pilot training concept in action, 691– 698, 2020, with permission from Elsevier [26]
(median score 58% vs. 67%, P < 0.001). Fur­thermore, participants signicantly improved their technical skills on the simulator in terms of accuracy (suture accuracy 43% vs. 99%, P < 0.001) and speed (87 vs. 42 s., P < 0.001) in the preand post-assessment of technical skills on the simulator, regardless of the expertise level or trainees position (Fig. 6). We showed that by practising on the simulator one signicantly improves the accuracy and speed of endoscopic suturing on the simulator, independent from the expertise level [26].
5 Future Perspectives
For future, we envision a training trajectory rather than a single course. Successful adaption of a new procedure requires structural and repetitive training. To develop and optimize a MIMVS curricula that incorporates simulation, one should have an air-pilot training concept course and accessibility of simulation models at the institution or at home to continue practic­ing. During the training one should receive
The Role of Simulators in Safe Adoption of Endoscopic Mitral Valve Surgery 285
Fig. 7 Timeline of the air-pilot concept programme with inclusion of the training at our course, simulation and proctoringat the participantshome centre and actual start of a self-managed programme. Reprinted from Interactive CardioVascular and Thoracic Surgery, Volume 30, Issue 5,
mentorship and proctorship to gain formative and metric based feedback. Finally, a clinical objective certication may be commissioned (Fig. 7)[24].
References
1. Holzhey DM, Seeburger J, Misfeld M, Borger MA, Mohr FW. Learning minimally invasive mitral valve surgery: a cumulative sum sequential probability analysis of 3895 operations from a single high­volume center. Circulation. 2013;128:483–91.
2. Ng CK, Nesser J, Punzengruber C, Pachinger O, Auer J, Franke H, Hartl P. Valvuloplasty with glutaraldehyde-treated autologous pericardium in patients with complex mitral valve pathology. Ann Thorac Surg. 2001;71:78–85.
3. Bolling SF, Li S, OBrien SM, Brennan JM, Prager RL, Gammie JS. Predictors of mitral valve repair: clinical and surgeon factors. Ann Thorac Surg. 2010;90:1904–12.
4. Shuhaiber J, Anderson RJ. Meta-analysis of clinical outcomes following surgical mitral valve repair or replacement. Eur J Cardiothorac Surg. 2007;31: 267–75.
5. Galloway AC, Colvin SB, Baumann FG, Grossi EA, Ribakove GH, Harty S, Spencer FC. A comparison of mitral valve reconstruction with mitral valve replacement: intermediate-term results. Ann Thorac Surg. 1989;47:655–62.
6. Modi P, Hassan A, Chitwood WR Jr. Minimally invasive mitral valve surgery: a systematic review and meta-analysis. Eur J Cardiothorac Surg. 2008;34:943–52.
7. Sündermann SH, Sromicki J, Biefer HRC, Seifert B, Holubec T, Falk V, Jacobs S. Mitral valve surgery: right lateral minithoracotomy or sternotomy? A systematic review and meta-analysis. J Thorac Car­diovasc Surg. 2014;148:1989–95.
8. Aggarwal R, Ward J, Balasundaram I, Sains P, Athanasiou T, Darzi A. Proving the effectiveness of virtual reality simulation for training in laparoscopic surgery. Ann Surg. 2007;246:771–9.
Peyman Sardari Nia, Samuel Heuts, Jean H T Daemen, Jules R Olsthoorn, W Randolph Chitwood, Jr, Jos G Maessen, The EACTS simulation-based training course for endoscopic mitral valve repair: an air-pilot training concept in action, 691–698, 2020, withpermission from Elsevier[26]
9. Carpenter AJ, Yang SC, Uhlig PN, Colson YL. Envisioning simulation in the future of thoracic surgical education. J Thorac Cardiovasc Surg. 2008;135:477–84.
10. Hicks GL, Brown JW, Calhoon JH, Merrill WH. You never know unless you try. J Thorac Cardiovasc Surg. 2008;136:814–5.
11. Feins RH. Expert commentary: cardiothoracic surgi­cal simulation. J Thorac Cardiovasc Surg. 2008;135: 485–6.
12. Joyce DL, Dhillon TS, Caffarelli AD, Joyce DD, Tsirigotis DN, Burdon TA, Fann JI. Simulation and skills training in mitral valve surgery. J Thorac Cardiovasc Surg. 2011;141:107–12.
13. Verberkmoes NJ, Verberkmoes-Broeders EM. A novel low-delity simulator for both mitral valve and tricuspid valve surgery: the surgical skills trainer for classic open and minimally invasive techniques. Interact Cardiovasc Thorac Surg. 2013;16:97–101.
14. Hossien A. Low-delity simulation of mitral valve surgery: simple and effective trainer. J Surg Educ. 2015;72:904–9.
15. Sardari Nia P. From Bench to Reality: Development of Simulation, 3D Printing, and Air-Pilot-Training Concept Course for Endoscopic Mitral Valve Surgery. April 2019. doi:https://doi.org/10.25373/
ctsnet.8035631.
16. Cates CU, Gallagher AG. The future of simulation technologies for complex cardiovascular procedures. Eur Heart J. 2012;33:2127–34.
17. Greenhouse DG, Grossi EA., Dellis S, Park J, Yaffee DW, DeAnda Jr A, ... & Balsam LB. Assessment of a mitral valve replacement skills trainer: a simplied, low-cost approach. J Thorac Cardiovasc Surg. 2013;145:54–9.
18. Nia PS, Daemen JH, Maessen JG. Development of a high-delity minimally invasive mitral valve surgery simulator. J Thorac Cardiovasc Surg. 2019;2019 (157):1567–74.
19. Daemen JH, Heuts S, Olsthoorn JR, Maessen JG, Sardari Nia P. Mitral valve modelling and three­dimensional printing for planning and simulation of mitral valve repair. Eur J Cardiothorac Surg. 2019;55:543–51.
20. Khabbaz KR, Mahmood F, Shakil O, Warraich HJ, Gorman III JH, Gorman RC, ... & Hess PE. Dynamic
286 L. Aerts and P. Sardari Nia
Данная книга находится в списке для перевода на русский язык сайта https://meduniver.com/
3-dimensional echocardiographic assessment of mitral annular geometry in patients with functional mitral regurgitation. Ann Thorac Surg. 2013;95:105–10.
21. Maceira AM, Cosín-Sales J, Roughton M, Prasad SK, Pennell DJ. Reference left atrial dimen­sions and volumes by steady state free precession cardiovascular magnetic resonance. J Cardiovasc Magn Reson. 2010;12:1–10.
22. Lam JHC, Ranganathan N, Wigle ED, Silver MD. Morphology of the human mitral valve: I Chordae tendineae: A new classication. Circulation. 1970;41:449–58.
23. Ryan LP, Jackson BM, Enomoto Y, Parish L, Plappert TJ, John-Sutton MGS, ... & Gorman III JH. Description of regional mitral annular nonpla­narity in healthy human subjects: a novel methodol­ogy. J Thorac Cardiovasc Surg. 2007;134: 644–8.
24. Sardari Nia P, Olsthoorn J, Heuts S, Maessen J. Sutur­ing map for endoscopic mitral valve repair developed on high-delity endoscopic simulator. Multimed Man Cardiothorac Surg. 2018;26:2018. https://doi.
org/10.1510/mmcts.2018.038. PMID: 30192451.
25. Olsthoorn JR, Heuts S, Daemen J, Maessen J, Sardari Nia P. Clinical implications of three-dimensional mitral valve modelling, printing and simulation in mitral valve surgery. J Vis Surg. 2019. https://doi.
org/10.21037/jovs.2019.05.01.
26. Sardari Nia P, Heuts S, Daemen JHT, Olsthoorn JR, Randolph Chitwood W Jr, Maessen JG. The EACTS simulation-based training course for endoscopic mitral valve repair: an air-pilot training concept in action. Interact Cardiovasc Thorac Surg. 2020;30 (5):691–8. https://doi.org/10.1093/icvts/ivz323.
Trial of Current 3D Imaging Systems
Ludwig Müller
Abstract
The use of an endoscope in surgery is now commonplace in many specialities. Unfortu­nately for patients its use in cardiac surgery has had a slow uptake. Gradually more surgeons are starting to trial it out and are getting encouraging results. The introduction of 3D endoscopes was originally only as a part of a robotic system but over the past few years more industry partners have started to supply endoscopes capable of three dimensional visualisation. This chapter goes through the advantages and disadvantages of all the sys­tems currently available on the market and also covers reasons to consider the use of these advanced imaging options in cardiac surgery. The nal decision will need to be made by the surgeon and his team regarding this technology but we hope this chapter acts as a good introduction for those starting to look at this technology.
Keywords
3D videoendoscopyEndoscopic cardiac surgery
Human visionConvergence
1 Introduction
Endoscopic 3D imaging systems have heavily inuenced the practice of minimally invasive mitral valve surgery, isolated as well as in com­bination with tricuspid, atrial brillation ablation and atrial septal surgery including benign atrial tumours [1]. To a lesser extent but very important also endoscopic aortic valve replacement has been made feasible [2]. 3D video endoscopy had originally been limited to robotic systems [35] but was made available separately in 2014, i.e. without the extensive high tech and costly fea­tures of a surgical robotic system. Interestingly, one of the rst 3D video systems using rod lenses and introduced successfully for minimally inva­sive cardiac surgery was and is still made by the same manufacturer (Schölly Fiberoptic GmbH, 79211 Denzlingen, Germany) as the 3D endo­scope of the Da Vinci SISurgical System (Sunnyvale, CA USA).
In 2021 various 3D video endoscopic systems are on the market and merit an in-de pth analysis of function and use in daily practice as well as teaching.
Before the most up to date technology is analyzed it is reasonable to spend a few thoughts on human vison and 3D perception.
L. Müller (&) Department of Cardiac Surgery, Medical University Innsbruck, Innsbruck, Austria e-mail: ludwig.mueller@tirol-kliniken.at
© The Author(s), under exclusive license to Springer Nature Switzerland AG 2023 J. Zacharias (ed.), Endoscopic Cardiac Surgery,
https://doi.org/10.1007/978-3-031-21104-1_20
First, we have to realize that 3-dimensional vision and binocular or stereoscopic vision is not necessarily the same. Therefore also the term 3D imagingmight be misleading.
287
288 L. Müller
Данная книга находится в списке для перевода на русский язык сайта https://meduniver.com/
As we know from daily experience also single eyed, i.e. monocular vision works well for a 3­dimensional perception of our environment. Single eyed people are perfectly capable of car driving for example. And lots of pseudo 3D images are cheating us, e.g. in street art [6]. This is due to so called monocular cuesof 3D vision. More on that later.
Second: In addition to monocular cues depth perception is highly facilitated by so-called binocular cues, i.e. stereoscopic vision or stere­opsis. Different binocular cues contribute to a 3D image. Here 3D imaging systems come into place. Most interesting and striking news for those not specialized on this topic may be that we can perceive depth even if there is no 3­dimensional structure at all. This was studied intensively by Bela Julesz by construction of so­called random dot stereograms [7]. More on that also below.
Briey, depth perception can be accomplished by monocular and binocular cues and does not necessarily require a real 3-dimensional structure.
Third: We must apprehend that our eyes are not video cameras which record images or movies, but vision takes place exclusively in the brain. We discern between sensation and perception. Sensation is the process located in the eyes when photons activate receptors in the retina which send electrical signals to the brain. Now the highly complex process of perception, i.e. vision takes place. It involves a number of different brain areas located not just in the visual cortex but distributed widely over the brain. At the end our inner image appears in the frontal cortex including the perception of depth, i.e. 3D vision. And this process is not just complex with many different circuits involved, it is also not unidi­rectional, that means our nal vision is also determined by earlier experience and not limited to the visual sense but strongly determined also by multiple other e.g. tact ile inputs. Multiple signals travel from the frontal cortex back to the thalamus and optical cortex thereby inuencing the signals from the visual cortex which are sent
to the frontal cortex. This complex process is understood today only in part. Seeing without experience of the other sensory organs is not very helpful in daily life. It is demonstrated impres­sively by the history of Mike May [8] who lost his eye sight by a chemical explosion at the age of three. Although normal eye function was widely restored at the age of 46 by successful surgery, he did not regain normal vision, being unable to grasp three-dimensional vision and to recognize members of his family by their faces alone, as he says. This is of importance also for the understanding of our requirements on a sur­gical endoscopic video system.
The following is a short overview of the basics of 3D vision which may be important for the surgeon using a 3D imaging system. It is not a summary of actual knowledge on vision in neurophysiology and neuropsychology
Monocular cues for depth perception [9, 10]: Relative size: familiar objects appear smaller in distance.
Texture gradient: on closer objects more
details of surface structure can be seen.
Height in eld of view: distant objects tend to appear higher in our eld of view than closer ones.
Linear perspective: parallel lines e.g. railway rails appear to converge in the distance.
Aerial (atmospheric) perspective: effect of the atmosphere on the appearance of objects in the distance. They appear bluer.
Light and shadow: are strong indicators as they appear only in three dimensional structures.
Interposition (overlap, occlusion): an object which obstructs the view of something else is closer.
Defocus blur: because the depth of focus of the human eye is limited distant objects appear blurred.
Motion parallax (while the observer moves objects of different distance appear to move at different speed).
Depth from motion is calculated by use of the changing size of an object moving towards or off the observer.