Running the discharge calculations

Before you run the calculations, use the Mode option in the Home tab of the Ribbon Bar to change the run mode from Risk to Discharge. With this setting, the program will run the discharge calculations only, and will not then proceed to the dispersion and effects calculations.

Select the time-varying Scenario and then click on Run to perform the calculations. For some Scenarios the time-varying discharge calculations can be time-consuming, but for this Scenario they should run in about a minute.

When the results are complete, view the Graphs. The Flowrate Graph shows that the rate drops by about 1% in an hour of release, which means that the time-varying behaviour can be ignored for this release.

If the time-varying discharge calculations for a Scenario are time-consuming, you can make the analysis easier to work with if you bypass the time-varying discharge modelling for the hazardous event. There are two possibilities in this situation:

Using the averaged discharge results to create a User-defined source Scenario

Most of the Scenarios for a Pressure Vessel perform in-built discharge calculations to determine the state of the material after expansion to atmospheric pressure, which is the state required for the start of the dispersion calculations. However, the User-defined source Scenario is also available: this Scenario does not perform discharge calculations, but instead allows you to specify directly the state of the material after expansion to atmospheric pressure. You use it if you want greater control over the inputs to the dispersion and effect calculations, as will be described later in this chapter.

When you performed the discharge calculations, the program calculated the average rate over the first 20 s, and this is the representative rate given in the Discharge Report. If you decide that you want to use this average rate rather than the initial rate, you should right-click on the Scenario, and then select the first Create source option from the bottom of the right-click menu as shown.

There is a separate Create source option for each Weather for which you performed the discharge calculations. For this Scenario, the results will be the same for all Weathers, and when you select the Weather the program will create a User-defined source Scenario with the name User defined source for Category 1.5/F .

The dialog for the User-defined source Scenario does not include the Short pipe or Time varying release tab sections, and instead of containing fields for the pipe diameter and length, the Scenario tab section contains a Release segments table in which you specify the discharge rate and conditions directly, since the User-defined source Scenario does not perform any discharge modelling itself. The Scenario

will be created with discharge data taken from the averaged results from the Time varying Scenario, but you can edit these values if you choose.