- •Important Comments
- •Legal Principles
- •Copyright
- •Personnel Qualification
- •Intended Use
- •Symbols
- •Font Conventions
- •Number Notation
- •Safety Notes
- •The WAGO-I/O-SYSTEM 750
- •System Description
- •Technical Data
- •Manufacturing Number
- •Component Update
- •Storage, Assembly and Transport
- •Mechanical Setup
- •Installation Position
- •Total Expansion
- •Assembly onto Carrier Rail
- •Carrier rail properties
- •WAGO DIN Rail
- •Spacing
- •Plugging and Removal of the Components
- •Assembly Sequence
- •Internal Bus / Data Contacts
- •Power Contacts
- •Wire connection
- •Power Supply
- •Isolation
- •System Supply
- •Connection
- •Alignment
- •Field Supply
- •Connection
- •Fusing
- •Supplementary power supply regulations
- •Supply example
- •Power Supply Unit
- •Grounding
- •Grounding the DIN Rail
- •Framework Assembly
- •Insulated Assembly
- •Grounding Function
- •Grounding Protection
- •Shielding (Screening)
- •General
- •Bus Conductors
- •Signal Conductors
- •WAGO Shield (Screen) Connecting System
- •Assembly Guidelines / Standards
- •Scope
- •Abbreviation
- •Fieldbus Controller
- •Fieldbus Controller 750-837, /02x-000, 750-838, /02x-000
- •Description
- •Hardware
- •View
- •Variants
- •Device supply
- •Fieldbus connection
- •Display elements
- •Configuration and programming interface
- •Operating mode switch
- •Hardware address (Module ID)
- •Setting the baud rate
- •Operating system
- •Start-up
- •PLC cycle
- •Process Image
- •General Structure
- •Fieldbus specific Process Data Architecture
- •Digital Input Modules
- •Digital Output Modules
- •Analog Input Modules
- •Analog Output Modules
- •Specialty Modules
- •System Modules
- •Data Exchange
- •Communication objects
- •Communication interfaces
- •Memory areas
- •Addressing
- •Fieldbus specific Addressing
- •Absolute Addresses
- •Calculate Addresses
- •Address Range for Flags
- •Example for Absolute Addresses
- •Programming the PFC with WAGO-I/O-PRO CAA
- •WAGO-I/O-PRO CAA Library Elements for CANopen
- •IEC 61131-3 Program transfer
- •Transmission via the serial interface
- •Transmission via the fieldbus
- •Starting up CANopen fieldbus nodes
- •Connecting the PC and fieldbus node
- •Checking and setting the Baud rate
- •Setting the module ID
- •Changing to the OPERATIONAL status
- •Turning on the analog input data
- •Application specific mapping
- •LED Display
- •Fieldbus status
- •Node Status – Blink code from the 'I/O' LED
- •Supply Voltage Status
- •Technical Data
- •I/O Modules
- •General
- •Digital Input Modules
- •Digital Output Modules
- •Analog Intput Modules
- •Analog Output Modules
- •Special Modules
- •System Modules
- •CANopen
- •Description
- •Network Architecture
- •Transmission Media
- •Type of Cable
- •Maximum Bus Length
- •Required Conductor Cross Section
- •Cabling
- •Network Topology
- •Interface Modules
- •Configuration Software
- •Network Communication
- •Communication Objects
- •Process Data Object - PDO
- •PDO Protocol
- •Service Data Object - SDO
- •SDO Protocol
- •Initiate SDO Download
- •Download SDO Segment
- •Initiate SDO Upload
- •Upload SDO Segment
- •SDO Examples
- •Synchronization Object - SYNC
- •SYNC Protocol
- •Emergency Object (EMCY)
- •EMCY Protocol
- •CANopen state diagram
- •INITIALIZATION
- •PRE-OPERATIONAL
- •OPERATIONAL
- •STOPPED
- •Network Management Objects
- •Module Control Protocols
- •Start Remote Node
- •Stop Remote Node
- •Enter Pre-Operational
- •Reset Node
- •Error Control Protocols
- •Node Guarding Protocol
- •Heartbeat Protocol
- •Bootup Protocol
- •Object Directory
- •Initialization
- •Communication Profile Area
- •Object 0x1000, Device Type
- •Object 0x1001, Error Register
- •Object 0x1003, Pre-defined Error Field
- •Object 0x1005, COB-ID SYNC message
- •Object 0x1006, Communication Cycle Period
- •Object 0x1008, Manufacturer Device Name
- •Object 0x1009, Manufacturer Hardware Version
- •Object 0x100A, Manufacturer Software Version
- •Object 0x100C, Guard Time
- •Object 0x100D, Life Time Factor
- •Object 0x1010, Store Parameters
- •Object 0x1011, Restore default Parameters
- •Object 0x1015, Inhibit Time Emergency Object
- •Object 0x1016, Consumer Heartbeat Time
- •Object 0x1017, Producer Heartbeat Time
- •Object 0x1018, Identity Object
- •Object 0x1200– 0x1201, Server SDO
- •Object 0x1280– 0x128F, Client SDO
- •Object 0x1400– 0x141F, Receive PDO Communication Parameter
- •Object 0x1600– 0x161F, Receive PDO Mapping Parameter
- •Object 0x1800– 0x181F, Transmit PDO Communication Parameter
- •Object 0x1A00 – 0x1A1F, Transmit PDO Mapping Parameter
- •Manufacturer Specific Profile Area
- •Object 0x2000, Digital Inputs
- •Object 0x2100, Digital Outputs
- •Object 0x2200, 1 Byte Special Modules, Inputs
- •Object 0x2300, 1 Byte Special Modules, Outputs
- •Object 0x2400, 2 Byte Special Modules, Inputs
- •Object 0x2500, 2 Byte Special Modules, Outputs
- •Object 0x2600, 3 Byte Special Modules, Inputs
- •Object 0x2700, 3 Byte Special Modules, Outputs
- •Object 0x2800, 4 Byte Special Modules, Inputs
- •Object 0x2900, 4 Byte Special Modules, Outputs
- •Object 0x3000, 5 Byte Special Modules, Inputs
- •Object 0x3100, 5 Byte Special Modules, Outputs
- •Object 0x3200, 6 Byte Special Modules, Inputs
- •Object 0x3300, 6 Byte Special Modules, Outputs
- •Object 0x3400, 7 Byte Special Modules, Inputs
- •Object 0x3500, 7 Byte Special Modules, Outputs
- •Object 0x3600, 8 Byte Special Modules, Inputs
- •Object 0x3700, 8 Byte Special Modules, Outputs
- •Object 0x4200-0x4202, Gateway Module Input
- •Object 0x4500, Spacer Module Configuration
- •Object 0x5000, Read Input Process Image
- •Object 0x5001, Write Output Process Image
- •Object 0x5200, Controller Configuration Object
- •Object 0x5201, Diagnostics Configuration Object
- •Standard Device Profile Area – DS 401
- •Object 0x6000, Digital Inputs
- •Object 0x6005, Global Interrupt Enable Digital 8-Bit
- •Object 0x6006, Interrupt Mask Any Change 8-Bit
- •Object 0x6007, Interrupt Mask Low-to-High 8-Bit
- •Object 0x6008, Interrupt Mask High-to-Low 8-Bit
- •Object 0x6200, Digital Outputs
- •Object 0x6206, Error Mode Output 8-Bit
- •Object 0x6207, Error Value Output 8-Bit
- •Object 0x6401, Analog Inputs 16 Bit
- •Object 0x6411, Analog Outputs 16 Bit
- •Object 0x6421, Analog Input Interrupt Trigger Selection
- •Object 0x6423, Analog Input Global Interrupt Enable
- •Object 0x6424, Analog Input Interrupt Upper Limit Integer
- •Object 0x6425, Analog Input Interrupt Lower Limit Integer
- •Object 0x6426, Analog Input Interrupt Delta Unsigned
- •Object 0x6443, Analog Output Error Mode
- •Object 0x6444, Analog Output Error Value Integer
- •Object 0x67FE, Error Behavior
- •Reserved Area
- •Object 0xA000, Integer8 IEC 61131-1 Input variables
- •Object 0xA040, Unsigned8 IEC 61131-1 Input variables
- •Object 0xA080, Boolean IEC 61131-1 Input variables
- •Object 0xA0C0, Integer16 IEC 61131-1 Input variables
- •PDO Transmission
- •Mapping
- •Transmit PDO1
- •Receive PDO1
- •Transmit PDO2
- •Receive PDO2
- •SYNC Monitoring
- •Node Guarding
- •Heartbeat Monitoring
- •Error Message (Emergency)
- •Diagnostic Message of I/O Modules
- •Use in Hazardous Environments
- •Foreword
- •Protective measures
- •Classification meeting CENELEC and IEC
- •Divisions
- •Explosion protection group
- •Unit categories
- •Temperature classes
- •Types of ignition protection
- •Classifications meeting the NEC 500
- •Divisions
- •Explosion protection groups
- •Temperature classes
- •Identification
- •For Europe
- •For America
- •Installation regulations
- •Glossary
- •Literature list
- •Index
52• Fieldbus Controller 750-837, /02x-000, 750-838, /02x-000 Process Image
3.1.4.2 Fieldbus specific Process Data Architecture
With some I/O modules, the structure of the process data is fieldbus specific.
In the case of a CANopen coupler/controller, the process image uses a byte structure (without word alignment). The internal mapping method for data greater than one byte conforms to the Intel format.
The following section describes the process imagefor all of the coupler/ controller supported WAGO-I/O-SYSTEM 750 I/O modules when using a CANopen coupler/controller.
Note
Depending on the specific position of an I/O module in the fieldbus node, the process data of all previous byte or bit-oriented modules must be taken into account to determine its location in the process data map.
In the CANopen object directory the entire input process image can be read over the index 0x5000 and the entire output process image can be written over the index 0x5001.
3.1.4.2.1 Digital Input Modules
Digital input modules supply one bit of data per channel to specify the signal state for the corresponding channel. These bits are mapped into the Input Process Image.
When analog input modules are also present in the node, the digital data is always appended after the analog data in the Input Process Image, grouped into bytes. Therefore for each byte one Subindex is occupied.
Some digital modules have an additional diagnostic bit per channel in the Input Process Image. The diagnostic bit is used for detecting faults that occur (e.g., wire breaks and/or short circuits).
1 Channel Digital Input Module with Diagnostics
750-435
Input Process Image
Bit 7 |
Bit 6 |
Bit 5 |
Bit 4 |
Bit 3 |
Bit 2 |
Bit 1 |
Bit 0 |
|
|
|
|
|
|
Diagnostic bit |
Data bit |
|
|
|
|
|
|
S 1 |
DI 1 |
For the digital inputs the object 0x6000 (also 0x2000 possible) is used.
2 Channel Digital Input Modules
750-400, -401, -405, -406, -410, -411, -412, -427, -438, (and all variations)
Input Process Image
Bit 7 |
Bit 6 |
Bit 5 |
Bit 4 |
Bit 3 |
Bit 2 |
Bit 1 |
Bit 0 |
|
|
|
|
|
|
Data bit |
Data bit |
|
|
|
|
|
|
DI 2 |
DI 1 |
|
|
|
|
|
|
Channel 2 |
Channel 1 |
For the digital inputs the object 0x6000 (also 0x2000 possible) is used.
WAGO-I/O-SYSTEM 750
CANopen
Fieldbus Controller 750-837, /02x-000, 750-838, /02x-000 • 53
Process Image
2 Channel Digital Input Modules with Diagnostics
750-419, -421, -424, -425
Input Process Image
Bit 7 |
Bit 6 |
Bit 5 |
Bit 4 |
Bit 3 |
Bit 2 |
Bit 1 |
Bit 0 |
|
|
|
|
Diagnostic |
Diagnostic |
Data bit DI 2 |
Data bit DI |
|
|
|
|
bit S 2 |
bit S 1 |
Channe 2 |
1 |
|
|
|
|
Channel 2 |
Channel 1 |
Channel 1 |
|
|
|
|
|
|
For the digital inputs the object 0x6000 (also 0x2000 possible) is used.
2 Channel Digital Input Module with Diagnostics and Output Process Data
750-418
The 750-418 digital input module supplies a diagnostic and acknowledge bit for each input channel. If a fault condition occurs, the diagnostic bit is set. After the fault condition is cleared, an acknowledge bit must be set to reactivate the input. The diagnostic data and input data bit is mapped in the Input Process Image, while the acknowledge bit is in the Output Process Image.
Input Process Image
Bit 7 |
Bit 6 |
Bit 5 |
Bit 4 |
Bit 3 |
Bit 2 |
Bit 1 |
Bit 0 |
|
|
|
|
Diagnostic |
Diagnostic |
Data bit |
Data bit |
|
|
|
|
bit S 2 |
bit S 1 |
DI 2 |
DI 1 |
|
|
|
|
Channel 2 |
Channel 1 |
Channel 2 |
Channel 1 |
For the digital inputs the object 0x6000 (also 0x2000 possible) is used.
Output Process Image
Bit 7 |
Bit 6 |
Bit 5 |
Bit 4 |
Bit 3 |
Bit 2 |
Bit 1 |
Bit 0 |
|
|
|
|
Acknowl- |
Acknowl- |
|
|
|
|
|
|
edgement bit |
edgement bit Q |
0 |
0 |
|
|
|
|
Q 2 Channel |
1 |
||
|
|
|
|
|
|
||
|
|
|
|
2 |
Channel 1 |
|
|
For the digital outputs the object 0x6200 (also 0x2100 possible) is used.
4 Channel Digital Input Modules
750-402, -403, -408, -409, -414, -415, -422, -423, -428, -432, -433
Input Process Image
Bit 7 |
Bit 6 |
Bit 5 |
Bit 4 |
Bit 3 |
Bit 2 |
Bit 1 |
Bit 0 |
|
|
|
|
Data bit |
Data bit |
Data bit |
Data bit |
|
|
|
|
DI 4 |
DI 3 |
DI 2 |
DI 1 |
|
|
|
|
Channel 4 |
Channel 3 |
Channel 2 |
Channel 1 |
For the digital inputs the object 0x6000 (also 0x2000 possible) is used.
WAGO-I/O-SYSTEM 750
CANopen
54• Fieldbus Controller 750-837, /02x-000, 750-838, /02x-000 Process Image
8 Channel Digital Input Modules
750-430, -431
Input Process Image
Bit 7 |
Bit 6 |
Bit 5 |
Bit 4 |
Bit 3 |
Bit 2 |
Bit 1 |
Bit 0 |
Data bit |
Data bit |
Data bit |
Data bit |
Data bit |
Data bit |
Data bit |
Data bit |
DI 8 |
DI 7 |
DI 6 |
DI 5 |
DI 4 |
DI 3 |
DI 2 |
DI 1 |
Channel |
Channel |
Channel |
Channel |
Channel |
Channel |
Channel |
Channel |
8 |
7 |
6 |
5 |
4 |
3 |
2 |
1 |
For the digital inputs the object 0x6000 (also 0x2000 possible) is used.
3.1.4.2.2 Digital Output Modules
Digital output modules use one bit of data per channel to control the output of the corresponding channel. These bits are mapped into the Output Process Image.
When analog output modules are also present in the node, the digital image data is always appended after the analog data in the Output Process Image, grouped into bytes. Therefore for each byte one Subindex is occupied.
1 Channel Digital Output Module with Input Process Data
750-523
Input Process Image
Bit 7 |
Bit 6 |
Bit 5 |
Bit 4 |
Bit 3 |
Bit 2 |
Bit 1 |
Bit 0 |
|
|
|
|
|
|
not |
Status bit |
|
|
|
|
|
|
„Manual Op- |
|
|
|
|
|
|
|
used |
|
|
|
|
|
|
|
eration“ |
|
|
|
|
|
|
|
|
For the digital inputs the object 0x6000 (also 0x2000 possible) is used.
Output Process Image
Bit 7 |
Bit 6 |
Bit 5 |
Bit 4 |
Bit 3 |
Bit 2 |
Bit 1 |
Bit 0 |
|
|
|
|
|
|
not |
controls DO 1 |
|
|
|
|
|
|
used |
Channel 1 |
For the digital outputs the object 0x6200 (also 0x2100 possible) is used.
2 Channel Digital Output Modules
750-501, -502, -509, -512, -513, -514, -517, -535, (and all variations)
Ausgangsprozessabbild
Bit 7 |
Bit 6 |
Bit 5 |
Bit 4 |
Bit 3 |
Bit 2 |
Bit 1 |
Bit 0 |
|
|
|
|
|
|
controls |
controls |
|
|
|
|
|
|
DO 2 |
DO 1 |
|
|
|
|
|
|
Channel 2 |
Channel 1 |
For the digital outputs the object 0x6200 (also 0x2100 possible) is used.
WAGO-I/O-SYSTEM 750
CANopen
Fieldbus Controller 750-837, /02x-000, 750-838, /02x-000 |
• 55 |
Process Image |
|
|
|
2 Channel Digital Input Modules with Diagnostics and Input Process Data
750-507, -522
The 750-507 and 750-522 digital output modules have a diagnostic bit for each output channel. When an output fault condition occurs (i.e., overload, short circuit, or broken wire), a diagnostic bit is set. The diagnostic data is mapped into the Input Process Image, while the output control bits are in the Output Process Image.
Input Process Image
Bit 7 |
Bit 6 |
Bit 5 |
Bit 4 |
Bit 3 |
Bit 2 |
Bit 1 |
Bit 0 |
|
|
|
|
|
|
Diagnostic |
Diagnostic |
|
|
|
|
|
|
bit S 2 |
bit S 1 |
|
|
|
|
|
|
Channel 2 |
Channel 1 |
For the digital inputs the object 0x6000 (also 0x2000 possible) is used.
Output Process Image
Bit 7 |
Bit 6 |
Bit 5 |
Bit 4 |
Bit 3 |
Bit 2 |
Bit 1 |
Bit 0 |
|
|
|
|
|
|
controls |
controls |
|
|
|
|
|
|
DO 2 |
DO 1 |
|
|
|
|
|
|
Channel 2 |
Channel 1 |
For the digital outputs the object 0x6200 (also 0x2100 possible) is used.
750-506
The 750-506 digital output module has 2-bits of diagnostic information for each output channel. The 2-bit diagnostic information can then be decoded to determine the exact fault condition of the module (i.e., overload, a short circuit, or a broken wire). The 4-bits of diagnostic data are mapped into the Input Process Image, while the output control bits are in the Output Process Image.
Input Process Image
Bit 7 |
Bit 6 |
Bit 5 |
Bit 4 |
Bit 3 |
Bit 2 |
Bit 1 |
Bit 0 |
|
|
|
|
Diagnostic |
Diagnostic |
Diagnostic |
Diagnostic |
|
|
|
|
bit S 3 |
bit S 2 |
bit S 1 |
bit S 0 |
|
|
|
|
Channel 2 |
Channel 2 |
Channel 1 |
Channel 1 |
For the digital inputs the object 0x6000 (also 0x2000 possible) is used.
Output Process Image
Bit 7 |
Bit 6 |
Bit 5 |
Bit 4 |
Bit 3 |
Bit 2 |
Bit 1 |
Bit 0 |
|
|
|
|
|
|
controls |
controls |
|
|
|
|
not used |
not used |
DO 2 |
DO 1 |
|
|
|
|
Channel |
Channel |
||
|
|
|
|
|
|
||
|
|
|
|
|
|
2 |
1 |
For the digital outputs the object 0x6200 (also 0x2100 possible) is used.
WAGO-I/O-SYSTEM 750
CANopen