- •Safety and protection of the atmosphere
- •Statutory environmental performance
- •Indicators of reliability
- •Operational parameters
- •Supplying aggregate
- •The inclined conveyor
- •Drying aggregate
- •Gas cleaning equipment
- •The mixing aggregate
- •Aggregate of ready mix
- •Aggregate of mineral powder
- •The coolant pump station
- •Bitumen heater
- •Operator’s cabin
- •List of measuring instruments used for monitoring compliance with the production of technological modes
- •Supplying aggregate; 2- a cold bucket elevator; 3- dedusting aggregate; 4- drying barrel; 5- a hot bucket elevator
- •Description of technological process The technological process of production
- •The scheme of the input quality control at work
- •Scheme operational laboratory quality control at work
- •Scheme of operational control over the observance of technological modes at work
- •The scheme of acceptance of laboratory control at work
- •Environmental protection.
Aggregate of mineral powder
Bunker capacity of mineral
powder aggregate, m 3, not less 23
Method of loading the bunker with pneumo tools of cement
truck or stationary storage
Drive engine power, kW 2,75
Operating air pressure when
loading the bunker, MPa (kgf / cm 2) 0,1 (1)
Doser of mineral powder
-type Weighting with load cells
The highest limit of dosing
(NAP), kg 150
The lowest limit of dosing
(NmPD), kg 12
Limits of error for each
dose intervals:
- NmPD from 0.5 NAP 0.5% NAP ±.1
- more than 0.5 NPA to NPA as
% of nominal ±.1
The coolant pump station
The coolant Industrial oil
I-20A, and 30A
State Standard 20799-75
The quantity of oil poured
into the system, l 450
Performance of the pump when
pumping coolant viscosity
of 0.75 cm 2 / s, not less l / (m 3 / h) 1,1 (4,0)
Installed power, kW 2,2
Bitumen wires
(of bitumen heater to the mixer)
Nominal diameter of bitumen wires 80
pumping station
- amount, units. 2
- type of pump gear
- efficiency, t / h 20
The installed engine power, kW 11
Pneumatic system
Type of compressor Piston V-shaped, two-step,
two-cylinder air-cooled
Efficiency, m 3/min 0,75
Operating pressure, MPa (kgf / cm 2) 0,6(6)
Number of compressors 1
Engine power, drive, kW 7,5
Skip and dump body
spraying system
The working volume of the tank, m 3 (l), no more 0,3(300)
The applied liquid for spraying Domestic heating fuel
TU 38-101656-76 or
summer diesel fuel L-0, 2
State Standard 305-92
Engine power, kW 1,1
The pressure in the spraying system,
MPa (kgf / cm 2) 0,25 - 0,4 (2,5 - 4)
Bitumen heater
Type Batch with flue
The temperature of bitumen issued
to the mixer, K (0 C) to 433(160)
Tank capacity, m 3 30
Fuel used Diesel fuel "L"
State Standard 305-92
Fuel consumption, kg / hr 30
Installed capacity of fan
motor of burner, kW 0,55