64 Guidewire and catheter passage
Table 7.1 When to use fluoroscopy during guidewire and catheter passage
Task When? Purpose?
How often is
it necessary?
Planning puncture Prior to arterial
puncture
Identify anatomy when there is no pulse
or poor pulse; locate proximal femoral
artery for antegrade puncture
Occasional
Guidewire passage
through entry
site
Guidewire will not
pass
Guidewire passes through needle but
will not advance into artery; check
guidewire position/direction with
fluoroscopy
Occasional
Advancing
guidewire into
position
Soon after
guidewire enters
the artery
Observe guidewire progress; avoid
endoluminal injury; avoid passing the
guidewire into the wrong place
Always
Advancing
catheter through
entry site
Catheter will not
advance through
entry site
Check to see if catheter is coiling in the
subcutaneous tissue; check to see if
guidewire is bent
Rare
Advancing
catheter into
position
Soon after
catheter enters
the artery
Observe catheter progress; monitor
position; do not push catheter beyond
end of wire
Always
Removing
guidewire
After guidewire is
withdrawn from
catheter head
Observe appropriate formation and final
position of catheter head
Always
A
T12
L1
T12 T12
L1
L2
B
C
Fig. 7.1 Using landmarks to assist with catheter positioning. Bony landmarks are used to help place
the arteriographic catheter. (A) The renal arteries are usually located near the junction of the first
and second lumbar vertebral bodies. The twelfth thoracic vertebral body is identified by its attached
ribs and the operator counts down. (B) The catheter head is placed near the L1–L2 junction so that a
high-pressure injection of contrast will reflux a few centimeters above that level. (C) The aortogram
demonstrates the origins of the renal arteries.
https://t.me/med1917

Where does the guidewire naturally want to go? 65
the head of the ush catheter assumes its proper
shape (Fig u re 7. 2). As the guidewire is removed
from the curved-head shape of the ush catheter,
the catheter head, which has been straightened
onto the guidewire, assumes its shape, which short-
ens the overall length of the catheter. erefore, the
catheter head position is usually adjusted slightly
within the artery, as appears necessary. Aer the
guidewire is removed, if there is any doubt about
its position or whether it is safe to administer con-
trast in this location, it is useful to twirl the cath-
eter to ensure its tip is free within the ow stream.
It is usually best to avoid unguided interactions
between the catheter and any lesions along the way.
e position and behavior of the catheter is help-
ful for determining if the catheter is in a safe posi-
tion. If there is any doubt, hand administration of
a small amount of contrast will solve the issue. In
general, intermittent uoroscopy can be performed
to provide adequate information to guide the case
but minimize the radiation required.
GUIDEWIRE AND CATHETER
COMBINATIONS
ere are many correct guidewire and catheter
choices; however, if the one you have chosen is
not working, move on. e goal of the procedure,
whether strategic or therapeutic, determines the
order and range of choices of guidewires and cath-
eters. e guidewire is chosen rst for routine arte-
riography. If a guiding sheath is needed to treat a
lesion, a stier guidewire is required for sheath
placement. If crossing lesions is required to set
up a therapeutic procedure, a dierent guidewire
may be required. If the initial guidewire choice is
not successful, a catheter may be placed over it to
alter the handling characteristics of the guidewire.
Acatheter may add stiness, steering, and pushing
strength to a guidewire. When the goal is selective
catheterization of a branch artery before the lesion
is encountered, the catheter is selected rst. When
a selective catheter is required, the usual guidewire
choice is one that is hydrophilic (low friction) and
steerable (directionality).
WHERE DOES THE GUIDEWIRE
NATURALLY WANT TO GO?
In passing the guidewire there are certain locations
that are inexplicably entered on a routine basis dur-
ing the casual placement of the wire in preparation
for catheter advancement. It is important that the
location of the wire placement is conrmed before a
larger catheter is advanced over it, especially if it is
a treatment catheter for balloon angioplasty, stent-
ing, or other types of treatment. Deployment of
these larger catheters can cause injury if the wire is
inadvertently placed in a collateral or small branch
vessel. When passing a guidewire up and over the
aortic bifurcation, it is common for the wire to
bounce o the outer wall of the contralateral com-
mon iliac artery and enter the internal iliac artery
instead of the external iliac artery. Oen, when
passing the wire from the external iliac artery into
the common femoral artery it passes directly, as
intended. However, a signicant minority of the
time, the guidewire enters into the medial or lat-
eral circumex iliac vessels and attempts to enter
the pelvis or the epigastric vessels. Passing the wire
into the lower extremity, as it advances through the
popliteal artery there are numerous perigenicu-
lar collaterals that fan away from the P2 segment
A B
Fig. 7.2 Evaluating the catheter head to ensure
that it has reached its appropriate shape and
location. (A) As the guidewire is removed, the
catheter head can be observed taking its pre-
formed shape. (B) The catheter may be twirled to
make certain that the catheter head is not stuck
against the wall of the artery.
https://t.me/med1917

66 Guidewire and catheter passage
of the popliteal artery and form an arborization.
Some of these collateral branches appear parallel
to the popliteal artery itself, and the guidewire can
easily enter and be mistaken for being in the popli-
teal artery. Another example as the wire progresses
distally in the leg is the recurrent collateral that
originates from the proximal anterior tibial artery.
is usually originates within a few centimeters of
the anterior tibial artery origin and at the location
where the artery turns inferiorly. is collateral
passes retrograde in a superior direction. is is
oen how the anterior tibial artery is collateralized
when its origin is occluded. During an antegrade
approach to the lower extremity and immediately
aer common femoral artery puncture, it is quite
common for the guidewire to progress posteri-
orly and directly into the profunda femoris artery,
rather than enter the supercial femoral artery.
In passing the guidewire into the carotid
artery, as it progresses from the common carotid
artery into the carotid bifurcation, it is quite com-
mon for the guidewire to select the superior thy-
roid artery. It must be redirected into either the
internal or external carotid artery, depending on
the intention of the operator. When cannulating
the subclavian artery, the guidewire frequently
enters into the thyrocervical trunk. Likewise,
if the artery selected is the internal mammary
artery and the patient has a le internal mam-
mary gra, this must be recognized prior to using
this as a location for an exchange guidewire to be
placed. As the guidewire is advanced from the
subclavian artery into the axillary artery, it fre-
quently selects the large collaterals at the head of
the humerus. ere are other examples, but these
demonstrate that the operator must be vigilant
and understandthe anatomy and have an index
of suspicion about the potential for the guidewire
to enter the wrong location.
PASSING THROUGH DISEASED
ARTERIES
As a general rule, lesions are only crossed just
prior to performing therapy, if at all possible (see
Chapters 15 and 16). Occasionally, arteries may
be so diusely diseased that there is no approach
through relatively healthy segments for arterio-
graphic catheter placement. In addition, a puncture
may be placed in an artery with a seemingly normal
pulse, and there may be a severe but unsuspected
stenosis just upstream or downstream from the
puncture site. ese factors indicate that uoros-
copy should be initiated early aer guidewire inser-
tion. e guidewire should be advanced steadily but
carefully through diseased segments. If the guide-
wire forms a leading elbow, continue to advance the
guidewire but do not force it. You do not want the
guidewire to become a loop stripper. Be particu-
larly careful with hydrophilic wires in this regard.
When the guidewire does not cross the desired arte-
rial segment, place a dilator overthe guidewire to
secure the access site and remove the initial choice
guidewire. If the guidewire has formed a loop, use
the catheter to pull the guidewire back to remove
the loop. Use a pu contrast to conrm the intra-
luminal position and obtain information about the
diseased segment. e catheter is used in this case
to guide and support the guidewire. A hydrophilic-
coated guidewire may cross the artery with greater
ease. Use a steerable guidewire and probe the lumen
of the artery gradually as the guidewire is advanced
(Fi g ure7.3). Aer the guidewire is placed, the cath-
eter is advanced over it and continuously observed
using uoroscopy.
If the arterial segment that has been crossed is
severely diseased, the passage of the guidewire and
catheter may stop ow or slow it down. Consider
anticoagulation to avoid generating thrombus
Fig. 7.3 Passing through severely diseased arterial segments can be challenging. A steerable
guidewire may be used to make multiple turns when attempting to cross a lengthy critical lesion.
Theguidewire tip may be used to probe the lesion. After the wire is across a long lesion, pass a
hydrophilic or lubricious exchange catheter; usually, a straight tip is easiest. Place a sturdier wire over
which to advance devices. An alternative is to place a low-profile wire and follow it with a low-profile
balloon and predilate the lesion to create space for the treatment devices that follow.
https://t.me/med1917

Negotiating tortuous arteries 67
along the catheter and also consider whether the
arterial segment should be treated right away.
Stoppage of ow will also aect the appearance
of ow in the artery during arteriography. As
wire passes through each lesion in a sequence
of diseased segments, the wire directionality is
decreased. is makes the subsequent lesions
more dicult to cross and if the wire is all the way
across the diseased segment, it makes the wire tip
less responsive. In addition, each wire has its own
sha stiness and trajectory based on the angle of
approach. is causes wire bias (Fi g ure 7.4). is
is important because it inuences the course of
everything that subsequently passes over that wire.
Technique: Catheter will not follow
guidewire
1. Use gentle catheter manipulations to assess the
exact location where the catheter fails to pass.
Where is the hang-up? Is it at a location of dis-
ease or tortuosity? Is the guidewire at that loca-
tion sti enough or is that segment too oppy?
2. Is the guidewire kinked? A seemingly minor
kink may be very dicult to pass with the cathe-
ter. Use a magnied view to study the guidewire.
Withdraw the guidewire a few centimeters and
pass the catheter again.
3. Is the guidewire subintimal? Does the guide-
wire itself move freely within the artery?
Usually, when the guidewire is in a dissection
plane, it will not advance beyond a certain
point and it will appear tethered at the point of
subintimal passage. Is the guidewire in a small
collateral or side branch?
4. Is the lesion so critical that the guidewire itself
has interrupted ow and there is not enough
residual lumen to pass a catheter? In this case,
heparin should be given. Immediate plans
should be made for treating the lesion.
5. In these situations, consider passing a smaller
(4-Fr) straight catheter with side holes. Aer
the tip of the straight catheter is passed just
beyond the point of obstruction, the guide-
wire may be withdrawn and a pu of contrast
should clarify the situation and an appropriate
guidewire may be placed.
6. Is there too much friction when passing
the catheter through an occlusion? Use an
exchange catheter with hydrophilic coating.
Place a small caliber wire and predilate with a
low caliber over-the-wire balloon.
NEGOTIATING TORTUOUS ARTERIES
ere are two issues: advancing the guidewire
through a tortuous passage and advancing the cath-
eter over the guidewire. In very tortuous arteries,
the guidewire and catheter must be advanced as a
team; one and then the other until enough ground
is gained to make it all the way across (Fig ure 7.5).
An access sheath is placed. A hydrophilic wire is
introduced and advanced until it slows to a crawl.
An angled catheter is passed over the guidewire
to support it and to point the way to the next turn.
Aer the guidewire is advanced, the catheter is
advanced in turn. Sometimes, the guidewire will go
but the catheter will not go over it. Sometimes, the
guidewire will not advance unless it is supported
by a sheath and also a catheter. Tortuous arteries
place constrictions on guidewires and catheters that
may not be immediately obvious under the two-
dimensional representation available with uoros-
copy. Anatomic segments, such as iliac vessels and
branches of the aorta, may exhibit tortuosity, kinks,
and loops. Despite a widely patent lumen, forces on
the guidewire–catheter apparatus may be such that
A B
Fig. 7.4 Wire bias. This is caused by the stiffness
of the shaft of the wire, the angle of approach
that the wire must take, and the impingement
on the wire by lesions along its course.
(A) In this example, the wire is usually biased
toward one wall of the renal artery. The pres-
ence of a lesion may also influence the wire bias.
(B) In this example of the aortic arch, wire bias
may be present and will depend on which arch
branch is cannulated.
https://t.me/med1917

68 Guidewire and catheter passage
they are prevented from advancing aer passing
through multiple turns. Each turn in a tortuous sys-
tem restricts the forward movement and the steer-
ability of the catheter as it approaches the next turn.
Oblique views of the tortuous segments are useful
to identify the true angles followed by the arteries.
A steerable, hydrophilic guidewire helps to negoti-
ate the turns. A straight or angle tip catheter may be
passed over the guidewire to help straighten some
of the initial curves and provide support for the
guidewire as it goes into its next turn. A sheath may
also be placed, not just at the entry site but into or
through the tortuous segment to decrease friction.
Aer the guidewire and catheter have been passed,
consider exchanging the guidewire for a stier one
before initiating therapy. When the forward motion
of the catheter stalls, the options are as follows:
place the guidewire further into the system; place a
stier guidewire; exchange for a longer access sheath
to support the guidewire–catheter apparatus and
straighten some of the initial tortuosity; and use a
soer, more hydrophilic catheter. In more dicult
cases, a body oss can be performed by externalizing
both ends of the guidewire and putting tension on
both ends. Anexample of this is a brachial-femoral
wire during complex aneurysm repair.
How to pass through a diseased
artery that is also tortuous
Passing through tortuous arteries depends on
the ability of the operator to be able to change the
curve of the vessels by passing devices through
them and causing them to “accordion” to some
extent. When the arteries are also heavily calci-
fied and have no flexibility, the diseased and tor-
tuous system will attempt to push the catheter
backward. If there is a calcific shelf at an angle
in the pathway, it can damage the catheter or
catch it so that the operator gets resistance when
attempting to remove the catheter. These are
situations where the patient’s anatomy will not
bend to the operator’s will. Use the techniques
described, especially the telescoping technique
in which the catheter and the wire are advanced
one-and-then-the-other. The guiding catheter or
a sheath may also be advanced this way so that
there are three parts to the system. Monitor the
patient carefully for pain or other symptoms or
signs. These are the situations where rupture or
dissection is more likely. If unsuccessful, it may
be better to choose a different approach than to
forge ahead.
Wire Wire is
advanced
Angled tip on
the catheter
Catheter tip
Access
sheath
Wire has
advanced further
A B C D
Fig. 7.5 Crossing tortuous arteries. (A) An access sheath is placed. (B) A Glidewire
®
is advanced.
(C) An angled catheter is used to support the wire and point the way for the next advancement.
(D)The wire is advanced and the process repeated.
https://t.me/med1917

Remote puncture site 69
REMOTE PUNCTURE SITE
A very remote puncture site may be required
in a variety of circumstances and the tools are
generally available for most of these occasions. An
example of this includes infrainguinal interven-
tion through a brachial approach when a femoral
approach is contraindicated by anatomy, infec-
tion, previous surgery, or other conditions. e
approach required for arteriography is dierent
from that required for treatment. Arteriography
requires catheter positioning upstream from the
lesion, whereas therapy requires guidewire and
catheter placement across the remote lesion at a
distance where guidewire control may be poor. e
operator must be prepared to undertake multiple
maneuvers to reach the intended destination sev-
eral vascular beds away from the entry site. In gen-
eral, the closer the tip of the sheath can be placed
to the target lesion, the more ecient and safe the
control of the intervention.
In the example mentioned above, selective arte-
riography would necessitate catheter placement
in the distal iliac or femoral arteries. e guide-
wire is introduced into the brachial artery and
advanced retrograde into the subclavian artery.
A catheter and a steerable tip guidewire are used
to advance into the aortic arch and avoid enter-
ing branches. e angle of take-o of the subcla-
vian artery from the aorta determines whether the
guidewire will preferentially enter the arch or the
descending aorta, but it usually enters the ascend-
ing aorta. A curved tip catheter, such as an Omni
®
Flush, is oen required to direct the guidewire
inferiorly into the descending aorta. e guide-
wire is advanced into the distal descending aorta,
and the catheter may be advanced over it. If a lon-
ger guidewire is required, it may be exchanged at
this point. Usually a 260-cm angle tip Glidewire
®
is a reasonable choice. e guidewire is advanced
into the femoral artery using the steerable tip and
using the catheter for support. Aer the catheter
has reached the infrainguinal area, the guidewire
is withdrawn and arteriography performed. Once
a wire is placed retrograde across the origin of the
subclavian artery, it is best to protect the artery
wall with a catheter so that the wire, when placed
under tension, does not injure the wall.
If endovascular therapy is appropriate, the
guidewire is replaced and a long (90 cm) 6-Fr or
7-Fr sheath is placed over the guidewire. e patient
is heparinized to protect the brachial access site
from thrombosis and prevent thrombus formation
along the sheath. e steerable Glidewire
®
is
advanced antegrade into the infrainguinal arteries.
Anticipate the respective lengths of guidewires,
catheters, sheaths, and therapeutic delivery cath-
eters that are required. e long sheath provides
extra support for the guidewire and helps to main-
tain its pushability and steerability. Consider pass-
ing an angletip catheter through the sheath to assist
in directing the guidewire across the lesion. e
more remote the approach, the more you need sup-
port with a long sheath or guiding catheter. ere is
more information on this technique in Chapter14,
which covers access for endovascular therapy. It is
oen helpful, aer the sheath is in place and in a
stable position, to switch to a low-prole wire and
small caliber platform to increase maneuverabil-
ity. e same process would be followed to treat a
visceral or renal lesion from a proximal approach.
An aortic branch is oen best treated with an
angle tip sheath or guiding catheter. e length
of the catheters and wires may be a limiting factor
depending on the distance between the access site
and the lesion intended for treatment.
Technique: Guidewire–catheter
buckling
A catheter–guidewire combination that buckles
when the catheter is advanced (F i g ure 7. 6) has lost
its pushability. is is usually because of distance,
tortuosity, or lack of an adequate rail. Very oen
in this situation, the catheter will not advance
smoothly over the wire and additional maneuvers
are required. A stier wire may be required, and
sometimes a telescoping system of access is useful.
1. Double-check that the guidewire–catheter
position is intraluminal and not subintimal.
2. Try a stier guidewire.
3. Use a long sheath to decrease friction over the
length of the catheter.
4. Try a stier catheter (e.g., nylon).
5. Try a dierent approach with a shorter or
straighter course, rather than force one that is
not going to work.
6. Prior to passing the catheter through a tortu-
ous area, take slack out of the wire (Figu r e 7.7 ).
https://t.me/med1917

70 Guidewire and catheter passage
A B C
Fig. 7.6 Guidewire–catheter buckling. (A) A contralateral approach is selected for treatment of a
superficial femoral artery stenosis. (B) After initial access sheath placement, a catheter is advanced
with the intention of passing over the bifurcation. The wire is prolapsed into the infrarenal aorta.
Thiscreates slack in the system and encourages the possibility of the catheter prolapsing into the
infrarenal aorta rather than passing to the contralateral iliac artery. (C) In this setting, the slack must
be removed from the wire to offer smooth passage of the catheter.
A B C
Fig. 7.7 Situations where slack in the system promotes wire prolapse during catheter passage. After the
wire is in place, the catheter is advanced over the smoothest possible course. The principle of eliminat-
ing slack from the system applies to both angiographic catheters and treatment delivery catheters. Here
are some examples where slack may accumulate and prevent catheter passage. (A) After advancing a
wire into the carotid artery, the catheter may not follow in a tortuous arch. The wire tends to prolapse
back into the aortic arch. (B) When using a left brachial approach to the descending aorta, the turn from
the left subclavian artery into the aorta can be challenging and the wire tends toward prolapsing into
the arch and ascending aorta. (C) When a visceral or renal vessel is the target, there is limited distance
beyond the origin of the artery in which it is safe to pass the wire. When the catheter is advanced, rather
than follow the curve of the wire, it tends to drag the wire out of the vessel and prolapse into the aorta.
HOW TO CHANGE THE PLAN IF THE
CATHETER WILL NOT PASS AND YOU
HAVE TRIED EVERYTHING
Usually when this occurs, there is a fundamental
problem with your plan. Typically, you will have
already replaced any wire that is too oppy for
one that oers more support. More catheter sup-
port can also be gained by placing the sheath tip
very close to the area where the catheter must be
passed. In addition, sometimes the 0.035-inch plat-
form catheter is simply too large to pass through a
https://t.me/med1917

How do you decide if disease encountered on the pathway 71
heavily calcied or long occlusion. In this case you
can exchange it for a lower-prole wire and use a
hydrophilic catheter. Sometimes, a larger sheath
is required in order to support the force needed
to deliver the device. Lastly, consider the possibil-
ity that the wire passes through a place where the
catheter should not follow. An example would be if
it goes through the struts of a stent. If all of these
approaches fail, consider approaching the lesion
or artery segment from an alternative direction.
Change to an antegrade approach if the initial
approach was retrograde and change to a retro-
grade approach if it was antegrade.
HOW DO YOU DECIDE IF DISEASE
ENCOUNTERED ON THE PATHWAY
TO TREAT THE TARGET LESION
ALSO NEEDS TO BE TREATED?
When does treatment need to be initiated to
enhance wire or catheter passage or sheath pas-
sage? If there is a coincidental arterial lesion along
the way, how do you know when to go ahead and
treat it, or leave it alone? ere are a couple of
scenarios in which this will have a role. On the
way to treat a target lesion, if there is another
lesion in series with the target lesion as an inow
obstruction and it appears to be signicant, then
it usually should be considered for treatment.
An example of this would be a supercial femo-
ral or popliteal stenosis proximal to target tibial
disease. Another scenario is when the lesion is
coincidentally located in a pure access vessel and
does not diminish ow to the organ system that is
being treated. An example of this is when an up-
and-over approach encounters an iliac lesion on
the side of the puncture and contralateral to the
limb intended for treatment. If the lesion along
the access pathway is severe enough that the direc-
tionality in the passage of the catheter or sheath is
inhibited, then the lesion needs to be treated. If the
lesion alongthe access route is severe enough that
once the treatment sheath is passed through it that
ow is stopped, then it should be treated. Usually
it is best to perform angioplasty rst to create a
larger lumen. Pass the treatment sheath and treat
the target lesion. If the coincidental lesion requires
stent placement, that can be performed aerward.
Once a stent is placed it can create a point of fric-
tion or catch the edge of a sheath passing through
it. If there is doubt about the signicance of the
lesion, obtain oblique views to nd the greatest
degree of stenosis. Pressure across the lesion can
also be measured. However, the full pressure gra-
dient may not be accurate across an inow lesion
where there are lesions in series, since the more
distal lesion may cause outow obstruction.
Passing through dissected arteries
e most common situation in which an operator
is required to pass through a dissected artery is in
the case of aortic dissection (see “Passing through
aortic dissection”). However, there are also situa-
tions of dissection due to injury or spontaneous
dissection (carotid, renal, visceral). Another situa-
tion that every operator will face is when a dissec-
tion occurs during treatment, but the wire access
is inadvertently lost. Some examples of passing
through dissected arterial segments are shown in
Fi gure 7. 8 . Place a so tip, angled catheter, such
as a Glidecath
®
, close to the lesion. Do not per-
form a high-pressure injection, since this can lead
to additional propagation of a dissection. Allow
the dissected segment to ll with contrast and see
where it goes. If the dissection ap appears hazy
or there is no clear entrance, obtain oblique views.
Use a steerable, atraumatic 0.014-inch diameter
guidewire. Whichever wall of the artery appears
to have sustained the worst damage, steer the wire
toward the opposite side. Very oen, an entrance
to the dissection is visible. Advance the wire gently.
Allow the tip of the wire to oat and dance from
side to side to see if it can select the correctpathway.
A B C
Fig. 7.8 Passing through a dissected artery.
Inthis case guidewire access has been lost across
a partially treated lesion. (A) The wire is rein-
troduced using an angled catheter. (B) Oblique
views are obtained. Very often an entrance to the
dissection is identifiable. (C) A low-profile wire
is advanced and allowed to probe gently and
dance freely through the lesion.
https://t.me/med1917

72 Guidewire and catheter passage
Carefullyobserve the wire tip to see if it is free or if
it is pinned in tissue. Steer away from areas where
the guidewire seems to get caught in the tissue.
Aer multiple attempts to cross from one direc-
tion, if it will not pass, attempt crossing from the
opposite direction. Do not form a loop of wire as
this will tend to go into the dissection plane and
propagate the dissection further.
Passing through stents
Stents may cause diculty for wire passage
(Fi g ure 7.9). Both balloon-expandable and self-
expanding stents can provide challenges and both
types of stents can be damaged with aggressive
attempts at device passage through them. Self-
expanding stents, especially if they are an open
cell design, may have a degree of luminal irregu-
larity or sh scaling, where stent struts and joints
protrude into the lumen at locations of curvature.
Every stent has struts with various sized apertures
in between the struts, and all may easily accept pas-
sage of a guidewire. When this occurs, the guide-
wire may appear to be constricted in its course as
it passes through a portion of the stent. It can also
be dicult to discover whether the guidewire has
passed in between stent struts. If there is any doubt
about this, pass a simple curve catheter over the
wire. If it repeatedly hangs up at the same location,
the likelihood is extremely high that the wire has
passed through the stent struts. e rst passage
through a stent is usually best with a loop of atrau-
matic guidewire tip, such as a Bentson or Rosen.
Guidewires passed through stents typically have a
certain degree of wire bias, with a specic trajec-
tory of the wire as it enters the stent and exits the
stent. When the next catheter or device is passed
over the wire it will tend to catch on whichever
edge of the stent is aected most by wire bias.
When stents have been placed at the aortic bifurca-
tion and the goal is to pass up-and-over the aortic
bifurcation, it is quite common for the tip of the
catheter to catch on the stent as it traverses to the
contralateral side.
Passing through aneurysms
e development of stent–gra treatment of
abdominal aortic aneurysms has resulted in
aggressive catheterization of aneurysms. Passing
catheters through aneurysms is associated with a
risk of embolization of the compacted thrombus
A B C D
Fig. 7.9 Passing through stents. (A) The guidewire is advanced in a very loose and easy manner and
allowed to pass through the stent, preferably leading with a loop of atraumatic wire. (B) After the
guidewire is passed, if there is doubt about its location with regard to the stent struts, a catheter is
passed over the wire to see if it catches on the stent. In this case, the wire has passed through the
edge of the stent, This is detected by advancing a standard angled catheter. (C) Fish-scaling occurs
when an open cell stent is placed in a tortuous artery. The metal is bunched up on the inner curve and
in a place where the wire can be caught. In this case, a catheter is used to steer around it. (D) Wire bias
occurs as a result of the inability of the wire to conform to the angulation of the pathway. Occasionally,
this leads to direct interaction with a stent, which must be negotiated carefully. In this example, there is
a previously placed stent in the proximal left common iliac artery. The wire bias is such that the wire is
eccentric and on the stent surface. Care must be taken as a sheath is advanced through the stent.
https://t.me/med1917

How do you decide if disease encountered on the pathway 73
in the aneurysm sac. Associated occlusive disease
that involves the neck of the aneurysm tends to be
friable, and embolization is a risk when this mate-
rial is present. It is surprising that embolization
does not occur more oen. e usual approach is
retrograde through the common femoral artery.
Passing through aneurysms involves crossing the
iliac arteries, which may also be aneurysmal and
are likely to be tortuous, and then getting through
the abdominal aortic aneurysm.
Tortuosity of the iliac arteries may make the
approach challenging, especially if there is associ-
ated occlusive disease. Because occlusive disease and
calcication cause an iliac segment to become stier
than adjoining segments, relatively xed in con-
guration, and less pliable, the angle of curvature
is more extreme in the more compliant, juxtaposed
segments. Unfortunately, this causes the occlusive
lesions to be present at either end of a tortuous seg-
ment. erefore, the operator must be prepared to
use steerable guidewires and selective catheters to
cross the aneurysm. Sometimes, tortuosity is severe
enough that the loops formed as the guidewire
crosses the tortuous segments create signicant ten-
sion. As the forward progress of the guidewire bogs
down, the back pressure by the vessel system on
the wire tries to “spit out” or force back the guide-
wire. When this happens, reconsider the approach.
If signicant tortuosity occurs in an aneurysmal
common iliac artery, the guidewire may want to
“pile up” inside the iliac aneurysm and the neck may
be dicult to nd since it is not a straight shot.
Passage of a guidewire through a large abdomi-
nal aortic aneurysm can be dicult if the neck is
hard to nd. e wire tends to get lost and pile up
in the wide open space of the aneurysm. High-
pressure contrast injection into the aneurysm
to dene anatomy is contraindicated. Pung
contrast in the iliac arteries may be useful but in
the aneurysm it is useless since there is tremen-
dous mixing with nonopacied blood. Multiple
attempts at passage are sometimes required. e
guidewire should not be placed so redundantly
into the aneurysm that it curls up within the sac.
It is a counterproductive maneuver and may result
in embolization of aneurysm contents or tangling
of the guidewire.
It is usually best to place a standard access
sheath and pass a starting guidewire from the
femoral artery using uoroscopy. Oen, the
guidewire will pass without specic direc-
tion, despite tortuosity and nearly blind sacs. If
it does not pass, or when the wire tip starts to
coil up, place an angle tip catheter over it, such
as an MPB, a Berenstein, or a TegT. Exchange
for a steerable guidewire and advance carefully.
Pu contrast into the iliac arteries if necessary.
If a CT scan or other imaging study is available,
refer to that for clues about what to expect. Aer
entering the aneurysm from below, advance the
angle tip catheter over the guidewire and use it
to point the wire toward the neck of the aneu-
rysm (Fig ure 7.10). Always use a oppy-tipped
guidewire.
Fig. 7.10 Crossing
an aneurysm.
(A)The guidewire
tends to pile up
in the aorta when
crossing an aneu-
rysm. (B) A multi-
purpose, simple
curve selective
catheter, such as an
MPB, may be used
to direct the guide-
wire past tortuous
iliac and aortic
segments.
A B
https://t.me/med1917
Соседние файлы в папке Библиотека им академика М.И. Перельмана