24 Safe and strategic vascular access
pushing the needle through the back wall of the
graft, especially if the graft is not yet well incor-
porated. A 4-Fr micropuncture set is useful for
this task. If the graft is resistant to advancement
of the 4-Fr dilator, advance the 3-Fr trochar or
inner dilator and then gradually upsize until the
desired sheath is in place. Attempt to minimize
the size of the sheath since closure is not usually
performed for hemostasis.
Percutaneous puncture may also be performed
on a prosthetic gra that is immediately subcu-
taneous. e most common situation that calls
for this is evaluation of a dialysis access gra.
Occasionally, an axillofemoral, femoral–femoral,
or infrainguinal bypass gra requires direct punc-
ture. Local anesthetic is injected into the skin and
subcutaneous tissue over the gra. No skin inci-
sion is made. e needle tip is used to puncture the
skin and travel several millimeters in the subcuta-
neous tissue parallel to the gra. e needle hub is
then tipped away from the skin so that the needle
is at a 45-degree angle to the gra. e tip of the
needle is then inserted into the gra. is maneu-
ver creates a short subcutaneous tract that will help
protect the gra from infection. It also helps with
hemostasis. e needle should be introduced at
45 degrees or more to avoid a larger, oval-shaped,
or skiving type of puncture site hole in the gra,
which may be more dicult to control. Aer the
guidewire is placed, introduce the smallest caliber
catheter that is adequate for the intended purpose.
Since these puncture sites are usually away from
anastomoses, they are less subject to extensive
scarring around the gra.
Occasionally, a femoral artery that serves as
inow for an autogenous infrainguinal bypass
gra requires puncture. Aim for the hood of the
gra or more proximally along the artery. e
hood of the gra is usually where the pulse is felt
most easily. Use clips and any femoral calcication
seen on uoroscopy as landmarks.
PUNCTURE SITE COMPLICATIONS
The most common type of complication in endo-
vascular care is related to access. Complications
of arterial puncture are listed in Table 2.2. The
rates presented were accumulated using various
techniques but do not include those patients who
have undergone closure procedures at the punc-
ture sites. The worst complications the author
has seen are side branch punctures and side wall
punctures.
SUMMARY OF PUNCTURE SITE
OPTIONS AND CLOSURE STRATEGY
Puncture site options and their relative rates
of risk are summarized in Table 2.3. e retro-
grade femoral puncture is by far the most com-
mon and the most useful approach. Antegrade
femoral puncture is limited in its use to the
Table 2.2 Complications of femoral artery puncture and catheterization
Complication
Frequency
(%)
a
SCVIR complication
threshold (%)
b
Minor bleeding or hematoma 6.0–10.0
Major bleeding or hematoma (requiring transfusion, surgery, or
delayed discharge)
1.0–2.4 3.0
Pseudoaneurysm 0.5–5.0 0.5
Arteriovenous fistula 0.01–0.1 0.1
Occlusion (thrombosis or dissection) 0.3–1.0 0.5
Perforation <0.5
Distal embolization <0.5
Infection <0.1
a
From Valji K. Standard angiographic and interventional techniques. In: Valji K, ed. Vascular and Interventional
Radiology. Philadelphia: WB Saunders, 1999:12–17 and Brown MA, Nemcek AA, Vogelgang RL. Interventional
Radiology Procedure Manual. New York: Churchill Livingstone, 1997:68.
b
From Spies J, Bakal C, Burke D et al. Standards for diagnostic arteriography in adults. J Vasc Intervent Radiol 1993;
4:385–395.
Abbreviation: SCVIR, Society of Cardiovascular and Interventional Radiology.
https://t.me/med1917

Summary of puncture site options and closure strategy 25
ipsilateral infrainguinal arteries; however, this
is the preferred approach for complex tibial
and pedal reconstruction. Proximal puncture
sites in the brachial or axillary arteries are used
whenthere is no adequate femoral puncture site or
when there is some anatomic advantage of a prox-
imal approach (e.g., superior mesenteric artery
stent). Right from the start of the case, you have
to be thinking about how the access will be closed.
Closure devices are indicated for retrograde femo-
ral puncture of the native artery. Many operators
have also used closure devices for antegrade femo-
ral, prosthetic gra, and brachial artery closure.
In general, closure should be considered in every
case. In situations of a diagnostic angiogram only
and a 4-Fr or 5-Fr sheath access, the operator may
elect to perform manual compression. For most
therapeutic cases, if the patient is a candidate for a
closure device, this is the simplest and safest way
to proceed. Ultrasound is extremely helpful for
assessing the potential of closure device usage and
also for increasing the likelihood that the device
will be successful by choosing the puncture site
very accurately. It is best not to be too close to
the inguinal ligament as the closure device going
through the ligament can become dislodged at a
later time. It is also best to be in the body of the
artery and to be away from areas of heavily calci-
ed plaque or obstructive lesions. Closure devices
are discussed in more detail in Chapter 30.
Table 2.3 Comparison of puncture site options
Puncture Usefulness
Technical
difficulty
Overall risk of
significant
complications
a
Comments
Retrograde
femoral
Most useful Simplest 1.7% More than 90% of cases may
be performed
transfemorally. It is the
simplest and has the
lowest complication rate
Antegrade
femoral
Useful for
ipsilateral
infrainguinal
arteriography or
intervention
Entering the
origin of the
superior
femoral artery
can be
challenging
A relatively safe approach.
Especially useful for
infrainguinal catheterization
in patients who have a
contraindication to crossing
the aortic bifurcation
Brachial Useful for
arteriography
and/or
intervention when
femoral access
not possible
More
challenging
than femoral
puncture but
simpler than
axillary
7.0% Smaller artery with tighter
neurovascular sheath.
Higher risk of neurologic
complications or distal/hand
ischemia. Consider open
exposure for sheath ≥6-Fr
Previously
placed
graft
Useful in patients
whose anatomy
is altered by
previous surgical
reconstruction
Perigraft scar
tissue can
make catheter
passage
difficult
Administer prophylactic
antibiotics if graft is
prosthetic
Source: From La Berge Golden RL, Kerlan RK et al. Interventional Radiology Essentials. Philadelphia: Lippincott
Williams & Wilkins, 2000.
https://t.me/med1917

https://t.me/med1917

27
3
Sheath access
INTRODUCTION
At the initiation of every case, access must be
secured. e basic sheath provides access for
medication and contrast, is advanced over a
guidewire, may or may not have a radiopaque tip,
secures the access site, prevents bleeding during
the procedure, and is an access point where diag-
nostic or therapeutic catheters can be introduced
into the vascular system. Chapter 2 oered some
advice about choosing an access site and mak-
ing it safe. Routine use of ultrasound guidance
for access and needleplacement was also covered
in Chapter 2. Aer the access site is selected, the
access needle is placed in the artery and the initial
guidewire introduced. en what? e usual situ-
ation is to proceed with placement of a standard
access sheath followed by arteriography. A guiding
sheath or guiding catheter is typically placed when
the decision is made to treat a specic disease seg-
ment. Access for endovascular therapy is covered
in Chapter 14. Asheath is used on every case, from
diagnostic arteriography to complex interventions.
As soon as the needle is in the blood vessel, you will
be ready to place a wire. is chapter includes the
steps you need to take between when the needle is
placed in the artery and when the access is secure.
BASIC ACCESS SITE STEP-BY-STEP
Guidewires are discussed in Chapter 5. e guide-
wire you introduce initially through the access
needle in the artery is a compromise. It must be
sti enough to serve as an initial rail for sheath
passage. e tip of the guidewire must be atrau-
matic, so that if pathology is encountered, it is not
disrupted. e guidewire must be inserted into the
vessel for a sucient distance that the anchoring is
secure in the vascular system for sheath advance-
ment, and a more rm or sturdy portion of the wire
is available at the skin level over which to advance
the sheath. If tortuosity or disease is encountered, a
steerable guidewire is sometimes necessary. Access
is performed with 0.035-inch diameter guidewires.
In general, steerable guidewires in this platform,
such as the Glidewire
®
, do not have much sha
strength for sheath placement. A Bentson Wire
Guide, Newton Wire Guide, or Starter
®
Guidewire
is usually adequate for initial atraumatic guide-
wire placement. If there is a lot of scar or disease
in the groin, a slightly stier Rosen wire might be a
better choice, but the tip is stier and a little more
traumatic. If a Glidewire
®
is needed, the author
usually exchanges it out using a 4-Fr dilator and
places a stier guidewire for sheath placement.
e author routinely uses micropuncture tech-
nique, as described in Chapter 2. Aer placement
of the 21-gauge micropuncture needle, the 0.018-
inch wire (which comes with the set) is advanced.
e 4-Fr or 5-Fr dilator with the micropuncture
is advanced. At that point, the 0.035-inch wire
selected by the operator is advanced.
As soon as the 0.035-inch introducing guide-
wire is in place, a basic access sheath must be read-
ily available. Arteriography through a 4-Fr or 5-Fr
catheter requires a 4-Fr or 5-Fr sheath, respec-
tively. If an intervention is already planned and the
anatomy already examined, prepare and deploy a
sheath through which to perform therapy. is is
faster and smoother than placing a small caliber
sheath and upsizing later. If there is a chance that a
therapy may be precluded by some anatomic detail
that will be revealed during the arteriographic
study, then go with a smaller sheath, initially for
https://t.me/med1917

28 Sheath access
diagnostic purposes only, so that a minimally sized
puncture site is created.
INITIAL MANEUVERS TO SECURE
THE ACCESS
Aer the guidewire is in place, some operators
use dilators on a regular basis and some do not.
Dilators are discussed in the section “When is a
dilator needed?”. Hold pressure on the groin when
the guidewire is alone across the arteriotomy. is
helps to prevent blood from accumulating under
the skin and around the puncture site in between
dilator or catheter exchanges. When the needle is
in the artery with the guidewire going through it,
do not hold pressure. e needle is rigid and push-
ing on it may cause it to dislodge or cause the nee-
dle tip to injure the artery.
Aer the guidewire is in the artery, it is
advanced away from the entry site. e guidewire
must be advanced through the entry needle and
into the artery at least far enough so that the oppy
tip portion of the guidewire has cleared the entry
site. Fluoroscopy is initiated and the guidewire is
advanced into the desired location. If resistance
is met by the guidewire, stop pushing and initiate
uoroscopy to help guide the process and avoid
injury. Pressure at the puncture site is held as the
needle is removed. e guidewire is wiped with
heparin–saline-soaked gauze or Telfa.
A dilator is placed. If a skin incision is desired, it
is best to perform the incision directly over the dila-
tor (Figure 3.1). Usually any sheath larger than 5-Fr
is placed more easily with a small skin incision. e
dilator is a hard material, is inexpensive, and will
be discarded aer the access is achieved. A surgi-
cal No. 11 blade can be placed directly on the dila-
tor and the dilator over the guidewire may be used
as a rail. is way the incision may be minimized.
When the incision is performed over the guidewire
itself, it is usually done blindly since blood comes
out of the access site and pools at this location.
When the puncture site incision is made over the
sha of the sheath, the blade can easily cut the thin-
walled sheath and it will leak until it is replaced.
When using dilators, go for the same French
number size as that of the sheath (this is a dilator
that is one size outside diameter (OD) smaller than
the sheath) or one size larger than the sheath (this
is a dilator that is the same size OD as the sheath).
If it is a scarred groin or the artery is calcied, use a
dilator with an OD the same size as the sheath (one
number size larger).
HOW DO YOU PLACE A SHEATH?
Aer the sheath is selected, the dilator for the
sheath and the sheath itself are each ushed and
wiped with heparinized saline. e stopcock on
the side arm is turned to the “o” position. Before
placing the sheath, double-check that you have
the desired size in hand. Lock the dilator hub in
place so that the dilator does not back out while
the sheath is being advanced. Check the skin inser-
tion site to see if the incision needs to be enlarged
slightly. is can be done with a mosquito clamp.
Conrm that the guidewire in place is sti enough
to facilitate sheath placement. Sheaths can usually
A
B
C
Fig. 3.1 Making a skin incision at the entry site.
It is important to minimize the size of the incision
to just what is needed for the case. (A) After the
guidewire is placed and confirmed to be in the
artery, a 4-Fr or 5-Fr dilator is advanced over the
wire. (B) When the dilator is withdrawn slightly,
it “tents” up the skin and draws out the tissue
immediately surrounding the puncture site.
(C)Ascalpel is used to incise the skin directly
over the dilator. A 6-Fr sheath requires a 2-mm
opening in the skin. A10-Fr sheath requires a
3-mm opening. The dilator will be discarded
and it is much more resistant to a scalpel cut
than a usual sheath. Bleeding from the skin itself
at the entry site is a common cause of concern
and repeat visits for the patient and phone calls
for the physician. Do this carefully and minimize
theincision to only what is needed.
https://t.me/med1917

How do you place a sheath? 29
be placed using a starting guidewire. If the sheath
is large, long, or passing through a scarred groin,
consider a stier guidewire. Make sure that which-
ever guidewire is in place has been advanced far
enough so that the oppy tip is well inside the
patient and that the artery entry site is crossed with
the stier portion of the sha of the wire.
Gradual, stepwise enlargement of the tract
and artery entry site with dilators is not always
required, but is the cleanest way to place a sheath
(Figure 3.2). If the sheath is upsized by two French
sizes or more, dilators should be used. When plan-
ning sheath placement through a dicult entry site
(e.g., a scarred groin or a previously placed bypass
gra), a series of vascular dilators should be used
to predilate the entry site to one French size larger
than the label on the sheath. is eases placement
and helps prevent a buckle at the tip of the sheath,
which can damage the arteriotomy site and unnec-
essarily enlarge it. In between passing each dilator
and, eventually, the passage of the sheath, pressure
should always be held at the puncture site to pre-
vent bleeding. Blood that accumulates under the
skin between each step forms the beginning of
a hematoma. If this is not managed diligently, at
some point in the case, especially aer anticoagu-
lation, it may not be clear if the patient is actively
bleeding at the puncture site. In addition, aer the
procedure, the only thing the patient will be able
to see is the puncture site. Minimizing blood col-
lection and ecchymosis at the puncture site is a
worthwhile endeavor.
e sheath is loaded onto the guidewire by an
assistant and advanced all the way to the entry
site. e guidewire is pinned by the assistant. e
operator maintains gentle manual pressure with
one hand at the access site and with the other hand
advances the sheath over the guidewire, through
the skin, and into the artery. Pressure is maintained
at the puncture site until the tip of the dilator or
the sheath is inside the artery to tamponade the
arteriotomy. e sheath is advanced by holding it
along its sha near its tip so that it does not buckle
as it goes through the skin. Sometimes it is helpful
to rotate the sheath back and forth to get through
the subcutaneous tissue. Place the side arm port in
a convenient orientation, usually toward the opera-
tor. Occasionally, when the sheath is advanced, the
dilator loosens at the hub and begins to back out. If
this occurs, the open end of the sheath will be push-
ing bluntly into the tissues and be damaged and
may also damage the artery. If this occurs, with the
dilator inadvertently backing out during advance-
ment of the sheath, stop advancing the sheath and
assess. If the sheath is not already inside the artery,
take it out and examine it. If the tip of the sheath
itself is damaged, get a new one. Pressure is main-
tained on the arteriotomy with the free hand until
the sheath can be felt going into the artery. Aer
the tip of the sheath clears the arteriotomy, there
is usually minimal resistance during advancement.
e hand advancing the sheath can usually sense
a “give” in the progress of the sheath, aer which
the sheath advances smoothly and easily. If there is
A C D EB
Fig. 3.2 Sheath placement. Sheath placement permits safe, simple, and hemostatic access.
(A)Aguidewire is placed in the infrarenal aorta. (B) The femoral arteriotomy is dilated using the
dilator appropriate to the sheath intended for placement. (C) Digital pressure is maintained over the
arteriotomy to prevent hemorrhage after the dilator is removed. (D) The dilator is placed within its
sheath and the dilator–sheath combination is advanced over the guidewire. Slight pressure at the
puncture site prevents buckling of the sheath. The sheath–dilator apparatus can be rotated as it is
advanced. (E)After sheath placement, the dilator is removed and the sheath flushed.
https://t.me/med1917

30 Sheath access
resistance, something may be wrong. Use uoros-
copy to evaluate. Occasionally, the tip of the sheath
becomes damaged and irregular and catches on
the artery as it is advanced. Sometimes, this dam-
age to the sheath is severe enough that the sheath
must be discarded and a new one placed to avoid
damaging the artery. Once the sheath tip is in the
artery, advance it to its hub.
Aer the sheath is placed, take out the dilator
that comes with the sheath, aspirate through the
side arm port, and ush with heparinizedsaline.
Aer administering contrast through the sheath,
it should be ushed. When you ush the sheath
with a syringe, point the syringe inferiorly
(toward the oor) to avoid getting air into the
sheath. e sheath should also be ushed inter-
mittently throughout any case. Occasionally, a
continuous slow infusion of heparinized saline
using a pressure bag is required to keep the sheath
clear. Ifthere is bleeding around a sheath during
the case, apply gentle pressure. If that does not
work, upsize the sheath to tamponade the tract.
If you upsize the sheath in this situation, use a
0.035-inch wire of adequate stiness, usually the
same wire that was used to permit sheath inser-
tion initially. If the sheath is withdrawn any sig-
nicant distance, to readvance it any further, its
dilator should be replaced before it is advanced.
If the so edges of the sheath tip have become
frayed during a placement attempt, place a dier-
ent one to avoid irregular tears at the arteriotomy
site. When a sheath is placed in a patient with
large and tortuous arteries, it tends to slide in and
out. If tortuosity is severe and is near the access
site, the sheath may start to back out on its own.
It is sometimes worthwhile to secure the sheath
with a stitch in the skin and around the hub to
avoid spontaneous sliding. If a catheter is placed
through the sheath that is labeled the same as the
sheath size (i.e., a 5-Fr catheter in a 5-Fr sheath), it
will not usually be possible to administer contrast
or heparinized saline through the side arm since
the catheter completely lls the sheath. When
performing interventions, you must know where
the sheath tip is located to avoid performing bal-
loon angioplasty or deploying a stent within the
sheath. When performing interventions, it is usu-
ally best to use a sheath with a radiopaque marker
at the tip. If the sheath tip is close to the treatment
site, the operator wants to avoid inadvertent bal-
loon angioplasty within the tip of the sheath.
Fluoroscopy is initiated as the catheter is
advanced over the guidewire past the sheath. When
lesions are encountered on the initial guidewire
pass, it is usually best to stop the wire advance and
secure the access site before crossing. If the guide-
wire is not far enough inside the artery to secure
the access, a careful attempt should be made to
cross the lesion. Guidewire and catheter exchanges
are dicult in this position, with the wire barely
inside the artery. Sucient guidewire must be
advanced into the artery so that the stier part of
the body of the wire is in the arteriotomy, in order
to support the advancement of a dilator. When a
lesion is encountered in the iliac artery during ret-
rograde femoral puncture and the guidewire does
not cross it, sometimes the wire can be looped on
itself distal to the lesion in order to get enough sti
wire length inside the artery to allow the stier
part of the wire to be at the arteriotomy site. If an
ipsilateral iliac lesion is anticipated, consider using
a long 5-Fr micropuncture. In this scenario, the
wire only has to cross the lesion once and the 5-Fr
access across the lesion will support the 0.035-inch
wire of choice.
If the access femoral artery is heavily calcied
or there is a lot of surrounding scar tissue, the
guidewire may well go into the artery, but there
may be signicant diculty in passing a dilator or
sheath over it. In this case, the tip of the dilator
may bounce o the diseased artery and the whole
system, guidewire and sheath, may begin to buckle
in the subcutaneous tissue. When the artery is
scarred in an obese patient, this scenario is even
more likely to occur, with the access sheath becom-
ing lost in the subcutaneous tissue. e operator
can push in a more downward direction to pass the
dilator, as if pushing toward the oor, so the dilator
approaches the artery at nearly a 90-degree angle.
e operator also guides the dilator and straightens
the guidewire in the subcutaneous tissue using the
nondominant hand (Figure 3.3). Aer the initial
dilator placement, the guidewire may be replaced if
a dierent one is required for negotiation of lesions
or if a stier wire is needed over which to advance
the sheath.
WHEN IS A DILATOR NEEDED?
Your best chance of a favorable puncture site is
the initial attempt. is is also the best opportu-
nity for an access site that can be managed with
https://t.me/med1917

When is a dilator needed? 31
a closure device – a straight tract of adequate size
leading to a smooth and regular shaped arteri-
otomy in a location along the anterior surface
of the healthiest part of the artery. Many of the
steps discussed so far, including, how to choose
the puncture site, use of ultrasound guidance
and micropuncture, and various things to do and
avoid, are all leading toward this goal. e last
step is to use dilators.
e use of dilators is unlikely to damage any-
thing, and in some cases may be of help. A 4-Fr
or 5-Fr sheath can usually be passed without dif-
culty. If there is a lot of periarterial scar or the
artery is heavily calcied, even a 4-Fr or 5-Fr sheath
may require use of a dilator. In general, the larger
the sheath, the more likely a dilator will help the
operator. Make sure the guidewire is still straight,
using uoroscopy, and that it is not twisted in the
subcutaneous tissue if there is any question. A dila-
tor may then be advanced to secure the entry site
and slightly dilate the tract. When the access site is
hostile, aer placement of the smallest dilator, usu-
ally 4-Fr, it is sometimes useful to replace the wire
with a sti exchange guidewire, such as an Amplatz
guidewire. When the operator is concerned about
the size of the sheath intended for placement or
the quality of the access site, it is appropriate to
initiate sheath placement using a dilator or even
a series of dilators. When endovascular therapy is
planned, the arterial access site may require sub-
stantial enlargement, to sheath sizes larger than
20-Fr. is is done by passing progressively larger
dilators over the guidewire (e.g., 6-, 8-, 10-Fr dila-
tors) until the site is adequately sized to accept
the intended therapeutic device. Since dilators
are sized by OD and sheaths are sized by inside
diameter (ID), a 7-Fr dilator is used to prepare
the tract for a 6-Fr sheath. Occasionally, in a very
scarred access site, it is necessary to place a dila-
tor that is one size larger than the intended sheath.
For example, an 8-Fr dilator may be required to
prepare the tract for a 6-Fr sheath. During sheath
A B
C
Fig. 3.3 Placement of the sheath in a calcified, thickened, or scarred artery. (A) After guidewire
placement and enlargement of the subcutaneous tract, the sheath is advanced. (B) If the artery is
calcified or thick walled, or there is surrounding scar tissue, the tip of the dilator will sometimes
bounce off the artery, instead of entering it. (C) The nondominant hand can be used to press the
tissues around the guidewire and guide the tip of the sheath into the artery.
https://t.me/med1917

32 Sheath access
placement, if the tip of the sheath hits signicant
resistance as it is being passed into the artery, it is
usually better to back o and take out the sheath
and place the dilator to prepare the way. Be sure
to inspect the tip of the sheath if the advancement
is aborted. Occasionally, the initial pass into the
subcutaneous tissue will result in tearing of the tip
of the sheath. Keep in mind that the dilators are
usually intended to prepare the tract and the arte-
riotomy, and usually do not need to be advanced to
the hub. Occasionally, dilators are used to “sound”
the artery, gently stretch the artery, or Dotter a
diusely diseased segment. is is a common
maneuver for obtaining access for larger vascular
devices such as stent–gra delivery catheters for
treatment of abdominal aortic aneurysm. In this
case, the dilator is usually advanced all the way
into the artery.
BASIC SIZING ISSUES
Sizing issues are confusing but they should be
considered prior to the case. erapeutic cases,
especially complex ones, may be a challenge with
respect to sizing. In this discussion, some of the
initial sizing issues are presented. More detail
about sizing can be found in Chapter 14. When
referring to sizing, the discussion is usually about
caliber. e length of each device is also important
and is discussed in multiple sections throughout
this text.
Guidewire diameter or caliber is measured in
inches. e number “035” refers to a guidewire
that is 0.035 inches in diameter. Guidewires are
described in Chapters 5 and 6. Available guidewire
sizes are 0.010, 0.014, 0.018, 0.025, 0.035, and 0.038
inches in diameter. Each guidewire caliber has
associated catheter sizes that are appropriate for
use with it. e most commonly used guidewires
are 0.14, 0.18, and 0.35 inches in diameter.
Dilator and catheter sizes are described using
the French system. is system is a description of
the caliber of the catheter. e French caliber mea-
suring system is based on pi (3.14), the number of
times that the diameter of a circle goes around the
outside of the circle to make up the circumference.
To convert from French measurement to the diam-
eter of the catheter or sheath, divide the sheath size
by pi or approximately 3. For example, the diam-
eter of a 6-Fr sheath is approximately 2 mm, or
6 divided by 3. e diameter of a 24-Fr sheath is
approximately 8 mm, or 24 divided by 3. To con-
vert a French size, divide by 3, and that is how big
the hole in the artery will be in millimeters.
Dilators and catheters are described by their
OD. Sheaths are sized by their ID. A sheath is
described by what will t through it. is is appro-
priate since the sheath serves as a conduit for intro-
ducing other devices into the vascular system.
A6-Fr sheath has a 2-mm diameter. When a sheath
is placed percutaneously, if it needs to be replaced,
it must always be exchanged for a sheath that is the
same French size or larger so that the artery does
not bleed around the sheath.
WHEN TO USE FLUOROSCOPY
Fluoroscopy–eye–hand coordination is a develop-
mental skill that must be gained by endovascular
specialists. All modern uoroscopic equipment
uses foot pedal controls. is introduces the poten-
tial for overuse and ineciency since plantarex-
ion and dorsiexion are required by the operator
intermittently throughout the case, oen while
both hands are working simultaneously.
Fluoroscopy is occasionally useful in plan-
ning the puncture. is is especially true for the
pulseless femoral artery or for antegrade femo-
ral puncture. When performing an antegrade
femoral puncture, where the accuracy of position
is very sensitive, uoroscopy can be very helpful
for orientation. Fluoroscopy is not usually required
during the actual puncture. Occasionally, when
there is blood return from the puncture needle but
the guidewire cannot be advanced, a uoroscopy
spot check of the position of the wire is warranted.
Soon aer the guidewire has been placed into
the artery aer a routine puncture, uoroscopy
should be initiated. is may be continuous or
intermittent but frequent. If there is any resistance
to guidewire advancement on the rst pass, the
operator should stop and check the wire’s progress
with uoroscopy. e guidewire may have turned
into the iliac circumex vessel or another collat-
eral route or may have encountered a lesion close
to the puncture site. Any encounters with lesions
must be observed using uoroscopy. If the opera-
tor suspects iliac occlusive disease ipsilateral to the
puncture, early initiation of uoroscopy is war-
ranted. Aer the guidewire is in place, the catheter
is observed with uoroscopy as it is passed over
the wire.
https://t.me/med1917

When to abandon an access 33
ABOUT ACCESS SHEATHS
A hemostatic sheath provides protection of the
arteriotomy from the irregular edges of endo-
vascular devices. Multiple guidewire or catheter
exchanges are made simpler and safer with a sheath
in place. A sheath reduces the friction encountered
at the access site when manipulating a selective
catheter into a branch. An access sheath has a one-
way hemostatic valve, a dilator to stien it during
placement, and a side arm port that is used for
the administration of medication or contrast. e
sheath is advanced only with the accompanying
dilator in place to avoid uncontrolled endarterec-
tomy by the hollow sheath tip. e operator must
be cognizant of the location of the tip of the sheath.
Any angiographic or balloon catheter must clear
the tip of the sheath in order to function properly.
If there is a lesion intended for treatment near the
puncture site, use a sheath with a radiopaque tip
so that the tip of the sheath is easily identied.
Sheaths are sized according to the largest diameter
catheter the sheath will accept (see “Basic sizing
issues”). Aer the sheath is placed, the seal of the
hemostatic valve can be opened for guidewire
insertion by placing the tip of the dilator through
the valve.
Technique: Handling access sheaths
1. Flush and wipe the sheath and its dilator with
heparinized saline.
2. Turn stopcock on side arm to “o” position.
3. Double-check sheath size before insertion.
4. Lock or snug-t the dilator into the hub of the
sheath.
5. Enlarge the skin entry site.
6. Use arterial dilators to prepare the tract.
7. Hold pressure at entry site during exchanges.
8. Pin the guidewire.
9. Insert sheath by holding along its sha, usu-
ally close to the tip of the sheath.
10. Rotate sheath slightly to pass through the
subcutaneous tissue.
11. Hold pressure at arteriotomy until the tip of
the sheath is in the artery.
12. Orient the side arm toward the operator.
13. Monitor the sheath’s dilator to make certain it
does not back out.
14. If there is catching or hesitation, check the
sheath tip is smooth.
15. If there is resistance in the artery, stop and
evaluate. Make sure the tip of the sheath is
smooth.
16. Advance sheath to its hub.
17. Aer placement, remove dilator, aspirate, and
ush.
18. Upsize the sheath if there is bleeding around it.
19. Do not advance the sheath without the dilator
in place.
20. Replace the sheath if tip is damaged or irregular.
21. Secure the sheath with a stitch if it tends to
slide out (not usually necessary).
22. Do not inject through the side arm if the
sheath is lled with an equally sized catheter.
HOW DO YOU DECIDE WHEN TO
PLACE A LARGER ACCESS SHEATH?
A common scenario is that the case begins with
the smallest adequate access for angiography.
When the decision is made to proceed to interven-
tion, the operator selects a new sheath and upsizes
to the caliber needed for the interventional devices
required. However, occasionally there is substan-
tial bleeding around the sheath, especially with
heavily calcied arteries. is may also be mani-
fested by a gathering hematoma at the access site.
In this case, it is best to upsize the sheath by one
French size to tamponade the hole. It also helps to
hold pressure at the access site for a few minutes,
even while the sheath is in place. Another scenario
where a sheath upsize may be required is if there is
signicant tortuosity in the iliac artery that can-
not be managed with the sheath selected or that
may be continuously pushing the sheath out of the
access site. In this case a larger and longer sheath
can be placed through the same site. It must be
two French sizes larger. e original sheath can
then be placed through it. For example, if a 6-Fr
sheath is needed for treatment, but it is not han-
dling well because of severe tortuosity, an 8-Fr
sheath can be placed and then the 6-Fr sheath
is placed through it (sheath-within-a-sheath).
is has the eect of allowing the 6-Fr sheath a
straighter path and with less friction.
WHEN TO ABANDON AN ACCESS
Abandoning an access is also discussed in
Chapter2. e key factor is to recognize as soon
as possible during the procedure that an access