      1. Technical data sets to test relay protection

Description

Information:

Note

Required Customer

Guaranteed Contractor

Microprocessor device for checking the equipment RP

1.

Type

2.

Manufacturer

3.

Standards

4.

Technical description

5.

Sources (generators) current

5.1

Sources (generators) current

6

5.2

Range of output current, single, without switching.А

5.2.1

6-phase AC (L-N)

6 x 0...30 А

5.2.2

3-phase AC (L-N)

3 x 0...60 A

5.2.3

1-phase AC (LL-LN)

1 x 0...90 A

5.2.4

DC (LL-LN)

1 x 0...±120 A

5.3

The output power of the current source, ВА

5.3.1

Power 6-phase AC (L-N)

6 x 400 VA

5.3.2

Power 3-phase AC (L-N)

3 x 800 Va

5.3.3

Power 1-phase AC (LL-LN)

1 x 1000 VA

5.3.4

Power 1-phase AC (L-L)

1 x 1600 VA

5.3.5

Power 1-phase AC (L-L-L-L)

1 x 1600 VA

5.3.6

Power DC (LL-LN)

1 x 1400 W

5.4

The minimum step change in current, mА

1,0

5.5

Load resistance, no more than, Ом

0,5

5.6

Overload protection and over-temperature

Yes

6.

Sources (generators) voltage

6.1

The number of voltage sources, things.

4

6.2

Range of output voltage, single, without switching, V

6.2.1

3-phase AC voltage (L-N)

3 x 0 ... 300 V

6.2.2

1-phase AC voltage (L-L)

1 x 0 ... 600 V

6.2.3

Direct current voltage (L-N)

4 x 0 ... ±300 V

6.3

Выходная мощность источника напряжения, VA

6.3.1

Power 3-phase voltage АС (L-N)

3 х 100 ВА (AC)

6.3.2

Power 1-phase voltage АС (L-N)

1 х 200 ВА (AC)

6.3.3

Power 1-phase voltage АС (L-L)

1 х 250 ВА (АC)

6.3.4

Power voltage DC (L-N)

1 x 300 Вт (DC)

6.4

The minimum increment mV

10,0

6.5

Load resistance, however, Ohm

140

6.6

Protection against short-circuit, overload, overheating

Yes

6.7

The range of frequency change, Hz

(10 – 1000) ± 0,01

6.8

The range of changes in the phase angle, power. deg.

(0 - 359,99) ± 0,01

6.9

Bit DAC analog outputs

16

6.10

The sampling period of the analog signal, msec

25 (800 points during the period f = 50Гц)

6.11

The change in amplitude, phase and frequency in each source

independent

6.12

The duration of continuous playing digital program, however, min.

5

7.

Low level outputs

7.1

Number of outputs

6

7.2

Setting range

0... ±10 В peak.

7.3

Maximum output current mA

1

7.4

Resolution, mcV

250

7.5

Overload indication

yes

7.6

Connection

combo jack

8.

Optional DC power supply

8.1

Ranges of voltage,V

0...260

8.2

Power,W

40

9.

Binary outputs, transistor

9.1

Type

The output circuits on the circuit with open collector

9.2

Amount

4

9.3

Update frequency, kHz

10

9.4

Maximum current mA

5

9.5

Connection

combo jack

10.

Digital (Binary) Inputs

10.1

Number of digital inputs, however, things

8

10.2

Trigger criteria

Switching from the sous-xux contacts or U post. U current is compared with a threshold. VALUE.

10.3

Input characteristics

threshold or without potential.

10.4

The ranges, however, V

20 В / 300 В

10.5

Resolution (polling period state) msec

100

10.6

Programmability

yes

10.7

The maximum measurement time

Unlimited

10.8

Galvanic upshot

yes

11.

Digital (Binary) Outputs

11.1

Number of digital outputs, however, thgs

4

11.2

Switching alternating voltage, however, V

250

11.3

Switching alternating current, at least, A

6

11.4

Switching capacity cycle

tо 100 000

11.5

Programmability

yes

11.6

The type of output contacts

Normally open a pair of relay contacts

12.

Time synchronization

12.1

Synchronizing two test plants at a distance using GPS

yes

12.2

Synchronization test sets at a distance using the IRIG-B

yes

12.3

Synchronisation with the mains power source

yes

12.4

Precision Time Protocol (PTP)

yes

12.5

The communication interface with the control PC

Ethernet (USB)

12.6

Signalings modes display control PC

yes

10.

Power

10.1

Supply voltage,V

220

10.2

Supply frequency, Hz

50

10.3

Power consumption, not more, V ∙ A

2200

10.4

The degree of protection of the device in accordance with GOST 14254, not less

IP20

10.5

Software to test all types of protection set

1

10.6

Connecting wires set

1

10.8

Russian interface

yes