•Submax HR (75% MPHR)

•Inf-post WMA at rest

•Low dose - no change

•Peak dose

–Augmentation of posterior wall

–No change in inf wall

–Other territories appropriate augmentation

•No ischemia, posterior borderzone viability

•Medical therapy, EF improves over time

Pretest probability of CAD influences stress testing results

•If low pre-test probability

–Potential for high rate of false positive tests

–False negative tests will be low

•If high pre-test probability

–False positive tests will be low

–Potential for higher rate of false negative tests

Pre-test probability affecting stress test results

100 pts Pretest likelihood

10 %

CAD +

Sensitivity = 80%

CAD –

 

 

 

10 pts

Specificity = 90 %

90 pts

 

 

 

 

 

 

 

 

False +

 

 

False –

 

True +

 

 

True –

 

 

 

 

 

 

 

9 pts

 

 

2 pts

 

8 pts

 

 

81 pts

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

False Positive rate = 53%

False Negative rate = 2 %

Pre-test probability affecting stress test results

100 pts Pretest likelihood

90 %

CAD +

Sensitivity = 80%

CAD –

 

 

 

90 pts

Specificity = 90 %

10 pts

 

 

 

 

 

 

 

 

False +

 

 

False –

 

True +

 

 

True –

 

 

 

 

 

 

 

1 pts

 

 

18 pts

 

72 pts

 

 

9 pts

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

False Positive rate = 1%

False Negative rate = 66 %