ETSI ES 201 980 V4.1.2 (2017-04)

8.5.2FAC cells

8.5.2.1Cell positions

The cells used for FAC are cells that are neither frequency references, nor time references, nor gain references, nor data cells in the symbols that do not contain the SDC.

FAC cells convey highly protected QAM symbols that allow fast detection by the receiver of the type of signal it is currently receiving.

For robustness modes A, B, C and D there are 65 FAC cells and for robustness mode E there are 244 FAC cells. Tables 62 to 66 give the position of the FAC cells for each robustness mode.

Table 62: Position of the FAC cells in robustness mode A

Symbol

Carrier number

0

 

1

 

2

26, 46, 66, 86

3

10, 30, 50, 70, 90

4

14, 22, 34, 62, 74, 94

5

26, 38, 58, 66, 78

6

22, 30, 42, 62, 70, 82

7

26, 34, 46, 66, 74, 86

8

10, 30, 38, 50, 58, 70, 78, 90

9

14, 22, 34, 42, 62, 74, 82, 94

10

26, 38, 46, 66, 86

11

10, 30, 50, 70, 90

12

14, 34, 74, 94

13

38, 58, 78

14

 

Table 63: Position of the FAC cells in robustness mode B

Symbol

Carrier number

0

 

1

 

2

13, 25, 43, 55, 67

3

15, 27, 45, 57, 69

4

17, 29, 47, 59, 71

5

19, 31, 49, 61, 73

6

9, 21, 33, 51, 63, 75

7

11, 23, 35, 53, 65, 77

8

13, 25, 37, 55, 67, 79

9

15, 27, 39, 57, 69, 81

10

17, 29, 41, 59, 71, 83

11

19, 31, 43, 61, 73

12

21, 33, 45, 63, 75

13

23, 35, 47, 65, 77

14

 

ETSI

132

ETSI ES 201 980 V4.1.2 (2017-04)

Table 64: Position of the FAC cells in robustness mode C

Symbol

Carrier number

0

 

1

 

2

 

3

9, 21, 45, 57

4

23, 35, 47

5

13, 25, 37, 49

6

15, 27, 39, 51

7

5, 17, 29, 41, 53

8

7, 19, 31, 43, 55

9

9, 21, 45, 57

10

23, 35, 47

11

13, 25, 37, 49

12

15, 27, 39, 51

13

5, 17, 29, 41, 53

14

7, 19, 31, 43, 55

15

9, 21, 45, 57

16

23, 35, 47

17

13, 25, 37, 49

18

15, 27, 39, 51

19

 

Table 65: Position of the FAC cells in robustness mode D

Symbol

Carrier number

0

 

1

 

2

 

3

9, 18, 27

4

10, 19

5

11, 20, 29

6

12, 30

7

13, 22, 31

8

5, 14, 23, 32

9

6, 15, 24, 33

10

16, 25, 34

11

8, 17, 26, 35

12

9, 18, 27, 36

13

10, 19, 37

14

11, 20, 29

15

12, 30

16

13, 22, 31

17

5, 14, 23, 32

18

6, 15, 24, 33

19

16, 25, 34

20

8, 17, 26, 35

21

9, 18, 27, 36

22

10, 19, 37

23

 

ETSI

Соседние файлы в папке материалы