- •Comprehensive reading
- •Comprehensive reading What is a Centrifugal Pump?
- •What is a gear pump?
- •How do gear pumps work?
- •What is a Piston Pump?
- •How do Piston Pumps work?
- •What is a screw pump?
- •How do screw pumps work?
- •What is a vane pump?
- •How do vane pumps work?
- •Unit one. Auxiliaries words and expressions
- •Air compressor
- •Starting
- •Stopping
- •Maintenance and operating troubles and remedy
- •Heat exchangers words and expressions
- •Heat exchangers. Plate type. Operation, maintenance and troubleshooting. Words and expressions.
- •Symptom cause remedy
- •Distillation systems oil/water separator. Sewage treatment.Incirator. Words and expressions
- •Text distillation systems
- •Oil water separators
- •Sewage treatment
- •Incinerator
- •Words and expressions
- •Sea Water Desalination
- •Vocabulary
- •Vocabulary Section
- •Only for advanced Section I -- Pump Operation and Maintenance
- •Predictive and Preventative
Heat exchangers. Plate type. Operation, maintenance and troubleshooting. Words and expressions.
troubleshooting - выявление повреждений
to reduce - уменьшать, снижать
considerably - значительно
filling - заполнение
occasionally - изредка, время от времени
afterwards - впоследствии
circumstance - обстоятельство
О- ring - уплотнительное кольцо
connection - связь, соединение
gasket - прокладка
sealing surface - уплотняющая поверхность
deposits - отложения
flow rate - расход
visible - видимый
further - далее, затем, зд: сильнее
deformed - деформированный
double - двойной
adjoining plate - прилегающая (примыкающая) пластина
volume - объем, размер
to decrease - уменьшать
respective - соответствующий
hole - отверстие
to apply - применять
opposite side - противоположная сторона
TEXT
Temperature of coolers is controlled by adjusting the cooling liquid outlet valve. The inlet valve is left open which ensures a constant pressure within the cooler. This is very important with sea water cooling where reducing pressure can result in air remaining in a cooler which will considerably reduce the cooling effect. Vents provided in the highest point of coolers should be opened on first filling and occasionally afterwards. Drain plugs are also fitted at the lowest point in coolers.
The plate heat exchangers should be opened and cleaned regularly and under normal circumstances every six months. The Q-rings in the connections, the gaskets and the sealing surfaces on the back of the plate should be checked before the heat exchanger is reassembled.
Symptom cause remedy
1. Reduced cooling a) Deposits a) Check the heat transfer efficiency. surface for deposits and
if any remove them.
b) The flow rates b) Check that flow rates for
for oil and water are oil and water are correct.
Incorrect.
2. Leakage visible on a) The plate pack is a) Tighten the plate pack
the outside of the not tightened enough. further.
plate pack.
b) The gaskets and b) Replace the gaskets and
sealing surfaces are the damaged plates.
not clean and the
plates are deformed.
c) Corrosion between c) Replace the gaskets or
the double gaskets the plate.
or in the same area
of the adjoining plate.
3. Fresh water or There is a hole in Remove the lower sea lubricating oil decrease the plate. water valve, apply a test volumes pressure on the opposite side in the respective and, if liquid flows from the systems. side under pressure, replace
the faulty plate.