Хорошев / ИЛП_материал_маг_02.15 / Спецификация AECMA Specification 2000M / MIL-STD-1388-2B
.pdfMIL-STD-1388-2B
APPENDIX E
A code which indicates physical and chemical characteristics of an item and identifies weight/fragility and preservative relative to the packaging of an item. For applicable codes, see MIL-STD-2073-1 and MIL-STD-2073-2.
283 PACKING CODE |
3 X - - |
A series of codes which identify packing requirements. Consists of the following subfields:
a. Level A Packing (A) |
1 X F - |
A code assigned to identify level “A” packing requirements. applicable codes, see MIL-STD-2073-1 and MIL-STD-2073-2.
b. Level B Packing (B) |
1 X F - |
A code assigned to identify level “B” packing requirements. applicable codes, see MIL-STD-2073-1 and MIL-STD-2073-2.
For
For
c. Minimum Packing (C) |
1 X F - |
A code assigned to identify minimum packing requirements. For applicable codes, see MIL-STD-2073-1 and MIL-STD-2073-2.
284 PARAMETERS |
6 3 X - - |
A field divided into nine subfields which describes technical capabilities/characteristics that an item of operational equipment, TMDE, or calibration equipment/standard is capable of measuring/generating, or which are to be measured on the UUT. Classified parameters and transistor logic levels are not listed in the CMRS. Classified parameters are listed in a classified supplement or appendix to the CMRS and that document appropriately controlled.
a. Parameter Grouping Code (PGC) |
2 A F - |
A two character code linking the requirements set by the unit under test to the capabilities of the SE.
SE PARAMETER GROUP CODE. A PGC of the SE.
SE UUT PARAMETER GROUP CODE. A PGC of the SE UUT which must match the PGC of the corresponding SE.
UUT PARAMETER GROUP CODE. A PGC of the unit under test (WT) which must match the PGC of the corresponding SE.
b. Input/Output |
(1/0) |
1 A F - |
A code specifying the |
corresponding parameter of the equipment in |
|
question (SE or UUT) as an input into equipment or output from the equipment. Codes are as follows:
- 481 -
|
|
MIL-STD-1388-2B |
||
|
|
APPENDIX |
E |
|
Input into equipment |
|
|
I |
|
Output from equipment |
|
|
0 |
|
SE UUT PARAMETER INPUT/OUTPUT CODE. An 1/0 code of the SE UUT. |
||||
SUPPORT EQUIPMENT INPUT OUTPUT CODE. An 1/0 code of the SE. |
||||
UUT |
PARAMETER INPUT/OUTPUT |
CODE. |
An |
1/0 code of the WT. |
|
c. Parameter |
|
|
1 2 X L - |
The |
characteristic (e.g., |
volts, |
DC, |
Hertz, etc.) which an item of TMDE |
is capable of measuring or which are to be measured on the WT.
SE UUT PARAMETER. A parameter of the SE UUT which requires measurement by the SE under analysis.
SUPPORT EQUIPMENT PARAMETER. A parameter which the SE under analysis is to measure.
UUT PARAMETER. A parameter of the SE UUT which requires measurement by the SE under analysis.
d. Range-From |
1 0 D - - |
The lowest value of a particular parameter which can be measured or generated.
SE UUT PARAMETER RANGE FROM. The lowest value of the parameter of the SE UUT that the SE under analysis must measure.
SUPPORT EQUIPMENT PARAMETER RANGE FROM. The lowest value of the parameter that the SE is capable of measuring.
UUT PARAMETER RANGE FROM. The lowest value of the parameter of the UUT that the SE under analysis must measure,
e. Range-To |
1 0 D - - |
The highest value of a particular parameter which can be measured or generated.
SE UUT PARAMETER RANGE TO. The highest value of the parameter of the SE UUT that the SE under analysis must measure.
SUPPORT EQUIPMENT PARAMETER RANGE TO. The highest value of the parameter that the SE is capable of measuring.
UUT PARAMETER RANGE TO. The highest value of the parameter of the UUT that the support equipment under analysis must measure.
f. Accuracy |
2 6 X L - |
A narrative description of the tolerances of the corresponding parameter.
- 482 -
MIL-STD-1388-2B
APPENDIX E
SE UUT PARAMETER ACCURACY. The amount of accuracy of the parameter of the SE UUT that the SE under analysis must measure.
SUPPORT EQUIPMENT PARAMETER ACCURACY. The amount of accuracy of the parameter that the SE is capable of measuring.
UUT PARAMETER ACCURACY. The amount of accuracy of the parameter of the UUT that the support equipment under analysis must measure.
g . Range/Value Code (R/V) |
1 A F - |
A code used to identify specific parameters as either a “range” or a specific “value”. List specific value parameters in the ‘Range-From” block.
Range |
R |
Value |
U |
SE UUT PARAMETER |
RANGE/VALUE CODE. The R/V of the SE UUT. |
SUPPORT EQUIPMENT PARAMETER RANGE/VALUE CODE. The R/V of the SE.
UUT PARAMETER RANGE/VALUE. The R/V of the UUT.
h . Operational/Specification |
1 A F - |
Parameter |
|
A code indicating whether the associated parameter is operational or specification parameter of the UUT.
Operational |
parameter |
O |
Specification parameter |
S |
|
285 PASS THROUGH |
PRICE |
8 N R - |
The cost added to items bought by a prime contractor which are delivered to the government with little or no value added by the prime contractor.
286 PERCENTILE |
2 N F - |
The percentage of all corrective maintenance actions that can be accomplished within a specified maximum time to repair.
MAINTENANCE LEVEL PERCENTILE. The percentile within the specified maximum time to repair for a given operations/maintenance level.
REQUIRED PERCENTILE. The percentile associated with the requirement maximum time to repair.
287 PERFORMANCE STANDARDS |
3 A L - |
Signifies when the following performance standards are required for an individual task.
- 483 -
MIL-STD-1388-2B
APPENDIX |
E |
Supervision required |
A |
Precision required |
B |
Time standard |
C |
288 PERSON IDENTIFIER |
3 X L - |
A three-position code identifying each person required to perform the subtask (codes “A” through “999”). Within a task, a given Person ID relates to a specific “Job” and a specific Skill Specialty Code.
289 PERSONNEL TURNOVER RATE |
4 N - A S |
||||
The portion of personnel, expressed |
in percent per year, leaving their |
||||
SSC |
which will be replaced by new personnel requiring training. |
||||
|
a. |
Military |
|
2 N R - |
|
The |
military |
turnover |
rate. |
|
|
|
b. |
Civilian |
|
2 N R - |
|
The |
civilian |
turnover |
rate. |
|
|
290 PHYSICAL |
AND |
MENTAL REQUIREMENTS |
6 5 X - - |
||
A narrative description identifying any unique physical or mental personnel attributes required or recommended as prerequisites to full qualification in the applicable task.
291 PHYSICAL SECURITY/PILFERANGE CODE |
1 X F - |
A code which indicates the security classification or pilferage control for physical assets. For applicable codes, see DOD 4100.38-M.
292 PILOT REWORK/OVERHAUL CANDIDATE |
1 A F - |
A code indicating selection status of certain complex assemblies/ components considered for pilot rework/overhaul (PR/O) as part of the preoperational support program.
Item is nominated for PR/O program |
Y |
Item is not nominated for PR/O program |
N |
Item is approved as an PR/O candidate by the |
A |
requiring authority |
|
Items nominated are those which require additional skills, training, support and test equipment, facilities, and technical data to ensure a rework/overhaul capacity concurrent with government support of the end item. Consideration shall be given to both intermediate rework and depot level overhaul items.
293 PRECIOUS METAL INDICATOR CODE |
1 X F - |
(PMIC) |
|
- 484 -
MIL-STD-1388-2B
APPENDIX E
A code which indicates the amount and type of precious metal contained in a specific reference numbered item. For applicable codes, see DOD 4100.38-M.
294 PREPARING ACTIVITY |
2 5 X L - |
The name of the activity preparing SE data.
295 PRESERVATION MATERIAL CODE |
2 X F - |
A code which indicates the material used to prevent or inhibit corrosion or deterioration of an item. For applicable codes, see MIL-STD-2073 series.
296 PREVENTIVE MAINTENANCE CHECKS AND |
1 A F - |
SERVICES (PMCS) INDICATOR CODE |
|
A code which indicates whether or not the task code is applicable to the PMCS tables.
Task |
is applicable to PMCS table |
Y |
Task |
is not applicable to PMCS table |
N |
297 PRIOR ITEM PROVISIONING LIST ITEM |
5 X L - |
|
SEQUENCE NUMBER |
|
|
(PRIOR ITEM PLISN) |
|
|
The PLISN which appeared on the Interim Support Items List, the Long Lead Times Items List, or first appearance of item in incremental pro visioing submittals.
298 |
PROCUREMENT QUANTITY |
3 N R - |
|
The number of systems\equipment being procured. |
|
299 |
PRODUCTION LEAD TIME |
2 N R - |
|
(PLT) |
|
The computed or expected time interval in months between placement of a new contract and shipment of the first deliverable quantity.
300 PRODUCTIVITY FACTOR |
3 N R 2 |
This factor is used to account for nonproductive time and has the effect of increasing manpower requirements for performing maintenance. For instance, if the soldier’s scheduled work day is 8 hours, he may only be available for 6 hours to do maintenance due to other duty assignments, in this case, the productivity factor is ((8-6)/8) + 1 = 1.25.
301 PROGRAM ELEMENT |
|
3 X L - |
A code consisting |
of up to three alphanumeric characters identifying |
|
the applicable |
SE |
program element specified by the requiring authority. |
- 485 -
MIL-STD-1388-2B
APPENDIX E
302 PROGRAM PARTS SELECTION LIST |
1 A F - |
(PPSL) |
|
A code indicating whether the part is included within contractually controlled Federal Supply Classes (FSC), as outlined in MIL-STD-965, Parts Control Program. Codes assigned are as follows:
Part is included in contractually controlled FSCs and approved for use in PPSL
Part is included in contractually controlled FSCs and not approved for use in PPSL
303 PROGRAM SUPPORT INVENTORY CONTROL |
2 A F - |
POINT |
|
A
N
A government code to identify the service supporting Inventory Control Point (ICP) where the using SE weapon/inventory manager is located. Codes are as follows:
Service/Agency |
ICP |
|
Code |
|
Marine |
Corps |
Marine Corps Logistics Base, Albany, GA |
PA |
|
USAF |
|
Sacramento ALC, |
CA |
TA |
|
|
Warner Robins ALC, Robins AFB, GA |
TG |
|
|
|
San Antonio ALC, Kelly AFB, TX |
SE |
|
|
|
Ogden ALC, Hill |
AFB, UT |
SU |
|
|
Oklahoma City ALC, Tinker AFB, OK |
SX |
|
|
|
AF Cryptologic Support Center (ESC), |
SJ |
|
|
|
San Antonio, |
TX |
|
Army |
|
Communications |
and Electronics Materiel |
CL |
|
|
Readiness Command, Fort Monmouth, NJ |
|
|
|
|
Tank Automotive Command, Warren, MI |
AZ |
|
|
|
Missile Command, Redstone Arsenal, AL |
BD |
|
|
|
Armament Munitions & Chemical Command |
BF |
|
|
|
Rock Island, |
IL |
|
|
|
Aviations Systems Command, St. Louis, MO |
CT |
|
|
|
Troop Support Command, St. Louis, MO |
AJ |
|
|
|
COMSEC Logistics Activity, Fort Huachuca, AZ |
CM |
|
Navy |
|
Ships Parts Control Center, Mechanicsburg, PA |
HD |
|
|
|
Aviation Supply Office, Philadelphia, PA |
KE |
|
FAA |
|
Mike Monroney Aeronautical Center |
48 |
|
|
|
Oklahoma City, OK |
|
|
304 PROPER |
SHIPPING |
NAME |
6 0 X L - |
|
The proper shipping name of the item to be transported, if this name is categorized as a hazardous material (e.g., CFR 49, UNTDF).
- 486 -
MIL-STD-1388-2B
APPENDIX E
305 PRORATED EXHIBIT LINE ITEM NUMBER |
6 X - - |
(PRORATED ELIN) |
|
The ELIN which was assigned to the previous item procurement on an item affected by proration,
306 PRORATED QUANTITY |
6 N R - |
The specific quantity remaining on order for the Prorated Exhibit Line Item Number.
307 PROVISIONING CONTRACT CONTROL NUMBER |
6 X F - |
(PCCN) |
|
A number assigned by the requiring authority to identify a specific contract or a group of end items/components that can have many configurations/models.
NOTE: The first position shall be alphabetic and will identify the applicable military service/agency provisioning designator having responsibility for the item(s) being processed.
First position codes are as follows:
Army
National Security Agency
Federal Aviation Administration
Marine Corps
Navy
Air Force
Coast Guard
Defenese Logistics Agency
SYSTEM/EI PROVISIONING CONTRACT CONTROL NUMBER. end item as a model (A indenture code) item.
A-I
J
K
N-R
S-X
Y
Z
The PCCN of the system/
308 PROVISIONING LIST CATEGORY CODE |
12AF- |
(PLCC) |
|
A code which indicates whether the item is documented on another list or is a government furnished item.
Government furnished |
A |
Interim support items |
B |
Long lead time item |
C |
Tools and test equipment |
D |
Common and bulk item |
E |
Repairable items |
F |
Interim released item |
G |
Installation and checkout item |
H |
Authorization stockage list item |
J |
Recommended buy list item |
K |
Prescribed load list item |
L |
System support package component list item |
M |
- 487 -
MIL-STD-1388-2B
APPENDIX E
309 PROVISIONING LIST ITEM |
5 X L - |
SEQUENCE NUMBER (PLISN) |
|
A sequentically assigned value for all items contained in the system/ equipment breakdown. The codes are as follows:
AAAA through 9999 (less I and O)
The numbering of line items shall begin with AAAA and progress through 9999, or as specified by the requiring authority.
a. When an item is contained in both a common and bulk items list (CBIL and a provisioning parts list (PPL), it may be assigned the same PLISN on both lists. When an item appears on a CBIL only, the PLISN may be unique (i.e., will not duplicate any PLISN in the PPL).
b. The fifth position of the PLISN shall be used to indicate addi tions to the breakdown. For this purpose, the letters A through Z, inclusive (except I and O) and the numbers O through 9, inclusive, shall be used starting with the letter A for the first addition and continuing sequentially through the alphabet and then through the numeric characters. An add entry, identified by the letters A, B, C, etc. , in the fifth position of the PLISN, is sequenced for inserting new items in the provisioning list either as a first or subsequent (same as) item en-
try, which |
will be used for either regular additions or replacement |
|
items. |
If |
the item listed is not an addition, the fifth position shall |
be left |
blank. |
|
SYSTEM/EI PROVISIONING LIST ITEM SEQUENCE NUMBER. The PLISN of the system/end item as a model (A indenture code) item.
310 PROVISIONING NOMENCLATURE |
6 5 X - - |
A description in narrative form used to provide additional identification of an item to be included in a repair parts manual.
311 |
PROVISIONING REMARKS |
6 5 X - - |
|
Narrative clarification of provisioning data. |
|
312 |
PROVISIONING SYSTEM IDENTIFIER |
3 X L - |
|
CODE |
|
|
A unique code assigned to a system/end item. |
The code will be assigned |
|
by the requiring authority. |
|
313 |
PROVISIONING TECHNICAL |
1 1 A - - |
|
DOCUMENTATION SELECTION CODE |
|
A code which indicates that an item is to be selected for a specific provisioning technical documentation list. If the item applies to a particular list, a “Y” is entered. Leave blank if the item does not apply. The lists for which items can be selected are as follows:
- 488 -
|
|
|
|
MIL-STD-1388-2B |
|
|
|
|
|
|
APPENDIX E |
|
|
|
a. |
Long Lead Time Items List (LLTIL) |
1 A F - |
|||
|
b. |
Provisioning Parts List |
(PPL) |
1 A F - |
||
|
c. |
Short |
Form Provisioning |
Parts |
1 A F - |
|
List |
(SFPPL) |
|
|
|
|
|
|
d. |
Common and Bulk Items List (CBIL) |
1 A F - |
|||
|
e. |
Repairable Items List (RIL) |
1 A F - |
|||
|
f. |
Interim Support Items List (ISIL) |
1 A F - |
|||
|
g. |
Post Conference |
List (PCL) |
1 A F - |
||
|
h. |
Tools |
and Test |
Equipment |
|
1 A F - |
List |
(TTEL) |
|
|
|
|
|
|
i. |
System |
Configuration |
|
1 A F - |
|
Provisioning List (SCPL) |
|
|
|
|||
|
j. |
As designated by requiring |
1 A F - |
|||
authority |
(one) |
|
|
|
|
|
|
k. |
As designated by requiring |
1 A F - |
|||
authority |
(two) |
|
|
|
|
|
—Note: Design Change Notice processing occurs against an established list (normally the PPL or PCL).
314 PROVISIONING |
UNIT OF MEASURE/ |
1 A F - |
ISSUE PRICE |
CODE |
|
A code used to indicate the Unit of Measure (UM) or Unit of Issue (UI) Price, which will be used for provisioning technical documentation, when multiple UM PRICES are entered.
UM/UI |
Price |
used |
Y |
UM/UI |
Price |
not used |
N |
UI PRICE PROVISIONING. The provisioning UI price.
UM PRICE PROVISIONING. The provisioning UM price.
315 QUALITATIVE AND |
QUANTITATIVE |
6 5 X - - |
MAINTAINABILITY |
REQUIREMENTS: |
|
NUCLEAR HARDENED |
CHARACTERISTICS, |
|
FAIL SAFE, ENVIRONMENTAL, ETC.
A narrative description identifying maintainability design constraints and characteristics that must be considered during the design process, to include:
- 489 -
MIL-STD-1388-2B
APPENDIX E
a.Fail Safe Requirements. A narrative description identifying
required fail safe characteristics (i.e., redundancy) back-up systems, built-in-test and warning equipment, fail safe provisions necessary to protect the equipment from serious damage after failure, and design features to prevent injury to personnel Subsequent to equipment failure).
b.Environmental Considerations. A narrative description identify
ing the applicable environmental conditions within which the item can operate satisfactorily. This information should include limitations, sensitivity factors, etc. , that can affect the performance and
reliability of the item installed in the system/equipment. Limiting fac- tors such as the following should be considered: shock limits; vibration
limits; ambient temperature ranges; operating temperatures in area (compartment) where item is installed in the system/equipment; humidity factors; altitude factors; magnetic interference; dust and dirt factors; salts or other corrosive atmosphere; and, light sensitivity. The narra- tive should include that portion of the system/equipment environmental impact statement which relates to the effects of the support system on the environment.
c. Nuclear Hardened Characteristics. A narrative description identifying the design characteristics which provide minimum nuclear survivability of the item. No design changes should be made without survivability/vulnerability evaluation to avoid inadvertent degradation of nuclear hardness.
316 QUANTITY PER ASSEMBLY |
4 A L - |
(QTY/ASSY) |
4 N R - |
The total number of times a line item is used in the assembly of which it is a part. If the quantity is unknown or cannot be determined, specify the quantity by “V” (variable) or as specified by the provisioning activity.
Option 1. The contractor shall enter the total number of times the
line item is used in the assembly of which it is a part. |
Note : |
Option 1 |
|||||
QTY/EI can only be used with Option 1 QTY/ASSY. |
|
|
|
|
|||
Option 2. For provisioning parts lists (PPLs) in reference designa- |
|||||||
tion format, enter the number |
of |
times |
the item |
appears |
at |
the |
location |
in the end item documented by |
the |
PPL. |
When an |
assembly |
is |
broken down |
|
by individual piece parts at its first appearance, the quantity for the
assembly |
and for each piece part at each location shall be the |
number of |
||||
times it |
appears in the assembly |
multiplied by the number |
of appearances |
|||
of the assembly in the |
end |
item. |
For other provisioning |
lists |
under |
|
option 2, the QTY/ASSY |
can |
be considered as the QTY/EI. |
|
|
||
Option 3. The contractor shall enter the total number of times the line item is used in the assembly of which it is a part. An assembly only. needs to be broken out to its piece parts at its first occurrence on a list. Subsequent appearances of the same assembly shall not be broken out.
- 490 -