Добавил:
kiopkiopkiop18@yandex.ru t.me/Prokururor I Вовсе не секретарь, но почту проверяю Опубликованный материал нарушает ваши авторские права? Сообщите нам.
Вуз: Предмет: Файл:

Ординатура / Хирургия / Библиотека им академика М.И. Перельмана / Книга_6051_Библиотеки_им_академика_М_И_Перельмана

.pdf
Скачиваний:
0
Добавлен:
10.10.2026
Размер:
7 Мб
Скачать
☆
7.RosePS,BridwellKH,Lenke LG,etal.Roleofpelvicincidence, thoracickyphosis,andpatientfactorsonsagittal
planecorrectionfollowingpediclesubtractionosteotomy.Spine2009;34:785–791PubMed
8. Lewis SJ, GrayR, David K, KopkaM, Magana S.Technique of Reverse SmithPetersen osteotomy (RSPO) ina
patientwithfixedlumbarhyperlordosisandnegativesagittalimbalance.Spine2010;35:E721–E725PubMed
9. Cho K-J,Bridwell KH, Lenke LG, BerraA, Baldus C. Comparison ofSmith-Petersen versus pediclesubtraction
osteotomyforthecorrectionoffixedsagittalimbalance.Spine2005;30:2030–2037,discussion2038PubMed
columnosteotomiesinspinaldeformitycorrection.Spine2014;39:870–880PubMed
resectionforspinaldeformity.Spine2006;31(19,Suppl):S171–S178PubMed
osteotomiesforrigidpediatricspinaldeformities.Spine2013;38:E493–E503PubMed
bloctumorexcision.Spine2012;37:346–350PubMed
2014;74:112–120,discussion120PubMed
spinopelvicparametercorrection?JNeurosurgSpine2011;14:184–191PubMed
alignment.JNeurosurgSpine2012;16:15–21PubMed
treatmentofvertebraldiscitis/osteomyelitiswithcollapse.Spine2010;35:1316–1322PubMed
approachforposterior-basedosteotomies.Spine2010;35:E471–E474PubMed
inseverespinaldeformities:atotalof102cases.Spine2011;36:E340–E344PubMed
severe pediatric deformity: minimumtwo-year follow-up of thirty-fiveconsecutive patients. Spine 2009;34:2213–
2221PubMed
4
Indications and Techniques for Sacral-Pelvic
FixationinAdultSpinalDeformity
KristenE.Jones,RobertA.Morgan,andDavidW.Polly,Jr.
Introduction
Fusion attempts across L5/S1 in adult spinal deformity are plagued by a high rate of
pseudarthrosis and implant breakage/failure due to the unique anatomic and
biomechanicalcharacteristicsofthelumbosacraljunction.
1,2
Inasingle-institutionreview
ofadultdeformitypatientswithconstructsgreaterthanfourlevels,constructsendingatS1
hadasignificantlyhigherrateofpseudarthrosiscomparedwithconstructsendingatL5or
more cephalad levels.
1
 Other pseudarthrosis risk factors were age older than 55 years,
more than 12 levels included intheconstruct, and T10-L2 kyphosis of greater than 20
degrees. The addition of sacral-pelvic fixation increases the strength and stability of
constructs spanning the lumbosacral junction and is a formidable tool in the spinal
deformitysurgeon’sarmamentariumforcorrectingspinalimbalance.
AnatomicandBiomechanicalConsiderations
As a transition zone from the mobile lumbar spine to the stiff pelvis, the lumbosacral
junction experiences significant forces challenging arthrodesis attempts across the
segment. Despite bearing axial loads of more than double body weight, the osseous
anatomyofthesacrumprovidesrelativelylittlestrengthforfixation.
3
Thesacrumconsists
ofathin rimofcorticalbone surroundingacancellouscore, withlargepediclediameter
precluding the engagement of both medial and lateral cortical walls via pedicle screw
instrumentation.
Thelumbosacraljunctionisabiomechanicallydistinctlocationthatissubjectedtothe
highestleveloftranslationalshearforceandthemostlimitedrangeofmotionwithinthe
spine, with the L5/S1 disk bearing the largest summation of load vectors.
2,4–6
 These
unique stresses, combined with the relatively small amount of sacral cortical bone
available for fixation, resultin increased pseudarthrosis and implant breakage/failure in
longinstrumentationconstructsendingatS1.
2,7
McCordetal
6
introducedtheconceptofthelumbosacralpivotpointatthejunctionof
the L5-S1 disk and the middle osteoligamentous column to describe the considerable
flexion moments and cantilever forces acting at the lumbosacral junction. Extending
fixationanterior tothispivot pointincreases constructstrength.Screw insertioninto the
iliumprovidesthelongestfixationlengthanteriortothispivotpoint,andwasfoundtobe
theonlyinstrumentation typeatthe lumbosacraljunctionthatsignificantly increasedthe
maximumflexionmomentatfailure.Comparedwiththeweakcancellouscompositionof
thesacrum,theposterioriliumoffersabundantcorticalboneforanchoringinstrumentation
and enablesincreased screwlength and diameter, makingsacral-pelvic fixationa useful
techniqueforincreasingconstructstrength.
IndicationsforSacral-PelvicFixation
Therigidfixationprovidedbysacral-pelvicinstrumentationisausefuladjuncttotreating
a widearrayof pathological entities. Sacral-pelvicfixation is indicated for lumbosacral
arthrodesis extending cephalad to the L2 vertebra, augmentation for poor quality or
osteoporoticbone,sacrectomyfortumororinfection,unstablesacralfractures,correction
of flat-back syndrome via lumbar osteotomy, correction of pelvic obliquity, and high-
grade spondylolisthesis.
8
 The addition of iliac fixation in these conditions significantly
reducesthestressplacedonS1instrumentationandincreasesconstructstrength.
As with all spinal surgery,selection of the appropriate approach for each individual
patientand meticulousattention tosurgicaltechnique isthe keytosuccessfultreatment.
Althoughsacral-pelvicfixationisnotrequiredformanypatientsundergoinglumbosacral
arthrodesis,theforcevectorsrequiredforthecreationandmaintenanceofpropersagittal
alignmentrelativetothepatient’sindividualbonequalitymustbeconsidered.
Sacral-PelvicInstrumentationSelectionandTechniques
SacralFixation
Screws atS1 can beplaced through thepedicles in amedially convergentmanner with
bicorticalend-plateortricorticalpurchase,orthroughthealainadivergentmanner(Fig.
4.1a).Sublaminarhooks andwiresandS2pedicle screwscanbeusedto supplementS1
pedicle/alarscrewsbutshouldnotbereliedonforanchoringalongconstruct.
S1PedicleScrews
The sizable medially convergent sacral pedicles accommodate large screw length and
diameter while simultaneously preventing “filling” the pedicle to achieve bicortical
purchaseofthemedialandlateralpediclewallwithasinglescrew.Thelargelycancellous
sacral pedicles provide relatively little pullout strength in unicortical fixation, and
unicortical pedicle screws should be avoided.
3
 Bicortical fixation anchored into the
anterior sacral cortex provides increased pullout strength compared with unicortical S1
pedicle screws; however, additional trajectories can be employed to further enhance
pullout strength. Luk et al
9
 compared bicortical S1 pedicle screw insertion torque and
pulloutstrengthtothatofS1pediclescrewsadvancedthroughtheS1superiorendplate.
S1pediclescrewstraversingtheendplatehadsignificantlyhigherinsertionaltorqueand
pulloutstrengthcomparedwithbicorticalS1screws.
Tricorticalfixation,definedasascrewtrajectorytowardthemedialsacralpromontory,
captures purchase in the dorsal, anterior, and superior end-plate cortex (Fig. 4.1b).
Lehman et al
10
 found that this tricortical trajectory doubles the insertional torque
compared with bicortical S1 pedicle screws parallel to the S1 end plate. Tricortical S1
screwstrengthhas notbeendirectly comparedwithtrans–end-platescrew strength;both
provideenhancedstrengthcomparedwithtypicalbicorticalpurchaseparalleltotheS1end
plate. Triangulationof the pedicle screw trajectory increases pullout strength compared
withstraight-aheadtrajectoryandshouldbeuniversallyemployed.
SacralAlarScrews
Alarscrewinsertion utilizesa lateral trajectoryinto low-densitycancellous sacral bone.
Bicortical alar fixation is technically possible but fraught with risk of injuring the L5
nerveroots orcommon iliacvessels drapedanteriorlyacrosstheala.
3
Thus,alar screws
are utilized mainly as unicortical supplements to bicortical/tricortical S1 pedicle screw
constructs.AChopin orColoradoplateoraTacoma blockcanbeutilizedtoconnectS1
andalarscrews.Disadvantagesofthistechniqueincludeconstrainedscrewstartingpoint
andpotentialimpairmentoftheidealtrajectory.
Fig.4.1a,bSacralscrewtrajectories.(a)TrajectoriesforS1pedicle(A)andalar(B)screwplacement.(b) Intraoperative
view demonstrating probe insertion in tricortical S1 screw trajectory. Tricortical purchase utilizing dense sacral
promontorycorticalboneshouldbeemployedtomaximizescrewpulloutstrength.
SacralSublaminarWiresandHooks
Althoughsublaminar wiresand hookslack sufficientbiomechanicalstrength toserve as
anchorstolongconstructs,theycanbeusedassupplementsforshort-segmentfusions.
3,11
Hooks areoptimally placed in thedorsal sacral neuroforaminawhereimproved cortical
purchase can be achieved. The Harrington instrumentation system initially employed
sacral hooks as anchors to long constructs, but the rate of pseudarthrosis and hook
dislodgmentatL5/S1 wasunacceptablyhigh.Sacralsublaminarwiresand hooksshould
notbeusedasanchorstolongconstructs.
S2Screws
S2 pedicle screw strength is typically limited by a short pedicle length and a location
dorsal to the lumbosacral pivot point described by McCord et al
6
 and Kebaish.
11
 S2
pediclescrewsandS2screwsdirectedlaterallyintothealacanbeusedasadjunctsupport
toshort-segmentfusionsbutlackthebiomechanicalstrengthtoanchorlongconstructs.
12
JacksonIntrasacralRodTechnique
JacksonintrasacralrodsareinsertedverticallythroughthealafromS1tothelevelofS2
and then can be connected to a construct including S1 pedicle screws. Insertion is
technicallydifficultandcanbeprecludedbyalaranatomicvariations.Thistechniquehas
been shown tobe biomechanically inferior to a lumbosacral pediclescrews–iliac screw
constructandismentionedforhistoricalcontextonly.
5
TranssacralFixation
Kellogg Speed first described transvertebral strut grafting at L5/S1 from an anterior
approach for patients with high-grade spondylolisthesis. The Speed technique involves
drivingafibularstrutgraftthroughtheL5vertebralbodyandintothesacrumviaanterior
exposure, and is a useful technique in lieu of interbody cage placement, which has an
increasedriskofanteriorsubsidenceforpatientswithhigh-gradespondylolisthesis.
13
Duetotheriskoftheanteriorexposuretothelumbosacraljunction,includinginjuryto
the great vessels during mobilization or sympathetic plexus dysfunction causing
retrograde ejaculation in males, H.H. Bohlman popularized the posterior approach for
transvertebralfibularstrutgraftingatL5-S1forpatientswithhigh-gradespondylolisthesis.
AnteriorfixationthroughL5/S1canalsobeperformedviaaparacoccygealapproachina
minimally invasive fashion utilizing synthetic implants. As with all constructs, the
additionofposteriorcolumnsupportincreasesstability.
IliacFixation
Anchoring a construct with iliac fixation creates a longer lever arm to resist cantilever
forces across the lumbosacral junction via extension anterior to the lumbosacral pivot
point,increasingbiomechanicalstrengthofsacral-pelvicconstructs.
6
Incorporationofthe
iliuminto aconstruct offloadsstressfrom sacralscrews anddecreasesthe rateof sacral
instrumentationfailureandpseudarthrosisacrossthelumbosacraljunction.
4,14
TransiliacFixation
HarringtonThreadedSacralRod
Developed forpelvic fixation inadjunct with Harrington distractionrods, this deviceis
mentionedforhistoricalpurposes.Twoseparateposterioriliacincisionsareusedtoinsert
the threaded rod through the posterior iliac wings with compression applied.
Pseudarthrosis rates have been reported above 40%m and the distraction forces of
Harringtonrodscanresultinsagittalplaneimbalance.
2,8
KostuikTransiliacBar
Inserted fromthe midline, theKostuik transiliac baris placed 1to 2 cmanterior to the
posteriorsuperioriliacspineandthenattachedviacustomconnectorstoS1pedicleoralar
screws. The bar is smooth and has a contoured shape that accommodates the midline
sacraldorsalprominence,andhasbeenreportedtohaveahighfusionrateofupto97%.
8
IliacFixation
LuqueL-fixation
Thefirsttodevelopsegmentalinstrumentation,Luqueextendedlumbosacralconstructsto
the pelvisusing L-shaped rodswhose ends were insertedinto the posteriorilium at the
posteriorsuperior iliacspine. Thiscircumvented thedistractionproblem associatedwith
theHarringtontechniqueandimprovedfusionrates,butpistoningoccurringbetweenthe
rodsdecreasedthestabilityoftheLuqueL-fixationintorsionandflexion.
2,8
GalvestonTechnique
Ben L. Allen and Ron L. Ferguson developed the Galveston technique in the 1980s.
Smoothrodsinsertedfromtheposteriorsuperioriliacspineintotheiliumwereconnected
tosegmentallumbosacral instrumentation.Rodcontouringrequiredsignificant expertise.
Toobviatetheneedforthis,rodswithpre-bentsagittalcontourandbilateraliliacfixation
werecreatedin asinglepiece.
3
This constructstillrequired substantialrod management
skills. Because the smooth rods had inferior pullout strength compared with threaded
screws,iliacscrewsquicklybecameamorepopularmethodoffixation.
IliacScrews
Iliacfixationwithsingleorstackedunilateralorbilateralscrewsisperformedwithfullyor
partiallythreadedscrews.Thepulloutstrengthand rotationalstabilityissuperiortonon-
threaded rod techniques. The starting point for screw insertion is at the level of the
posteriorsuperioriliac spinewitha trajectorytargetingeitherthesupra-acetabular notch
or the anterior superior iliac spine (Fig. 4.2). The screw trajectory is planned via
visualizationofthe“iliacteardrop”oneitherfluoroscopyorcomputedtomography (CT)
imageguidance.Theiliacteardropisaregionabovetheacetabulumborderingthemedial
iliac wall,the lateral iliac wall,and the zenith of thesciatic notch. The screwachieves
greatestpurchaseinthelateralmarginoftheteardrop, directedthrough thecorticalbone
justabovethe sciaticnotch.Santosetal
15
analyzedvariousscrew lengthsanddiameters
andfoundasignificant increaseininsertionaltorqueforiliacscrewsoflength≥80 mm
and diameter ≥ 9.5 mm. Nodifference in insertional torque existed between the supra-
acetabular notch and the anteroinferior iliac spine-directed trajectory. Given the risk of
acetabularjointviolationwiththesupra-acetabular trajectory,theauthors concludedthat
optimaliliacscrews areinsertedin theanteroinferioriliacspine trajectorywithlength ≥
80mmanddiameter≥9.5mm.
Iliac screws can be used in combination with sacral screws to provide increased
construct strength and are biomechanically superior to other pelvic fixation options.
Comparing the Galveston technique to iliac screws in a series of 20 neuromuscular
scoliosispatients,iliacscrewsenabledbettercorrectionofpelvicobliquityanddecreased
implantbreakage.
16
In a biomechanicalcomparison between the modified Galveston techniquewith iliac
fixationbutnoS1fixationversusS1pediclescrewsplusiliacscrews,orS1andS2screws
without iliac fixation, Tis et al
17
 found that constructs with iliac screws conferred
significant strength via decreased range of motion in multidirectional flexibility testing
andincreasedloadtofailure.
Bridwell’s group
4
 performed a laboratory investigation comparing multidirectional
flexibilityand flexuralload tofailure amongthe followingconstruct types:lumbosacral
pediclescrews,interbodycage,andiliacscrews.Iliacscreworinterbodycageplacement
significantly reduced multidirectional flexibility at the lumbosacral junction compared
withpediclescrewsalone,butiliacscrewfixationwassuperiorinprotectingsacralscrews
frompulloutorplowthrough.
4
Fig.4.2a–dIliacscrewplacementusingintraoperativecomputedtomography(CT)-basedframelessnavigation.(a)Iliac
screw insertion pointisat the posteriorsuperior iliac spine,directed toward theanterior inferior iliacspine.(b) The
teardropview is utilizedtooptimize screw purchaseinthe lateral corticalwall,just above thesciaticnotch. (c) The
sagittalviewis usedtodemonstratescrewangulation towardtheanteriorinferioriliac spine,avoidingviolationofthe
acetabulum.(d)Stacked iliac screw construct in patient with progressivedeformityfromhigh-gradespondylolisthesis
previouslyfusedinsitu,requiringsacralosteotomyfordeformitycorrection.
Lebwohl et al
5
 performed a laboratory biomechanical analysis comparing construct
stiffness, S1 screw strain, and ultimate failure load among several techniques of
supplementary sacral fixation, using S1 pedicle screws with and without S2 screws, as
wellasanintrasacralrodandiliacscrews.AlltechniquesdecreasedtheS1screwstrainin
flexion-extension, but only iliac screws decreased S1 screw strain in axial loading. In
destructivetestingwithflexionloading,onlyiliacscrewssignificantlyincreasedthe load
tofailure.Theauthorsconcludedthattheadditionofiliacfixationsignificantlyincreases
thebiomechanicalstrengthofsacralconstructs.
Asignificantdisadvantagetoiliacscrewsisthepotentialprominenceofthescrewhead
attheposteriorsuperioriliacspine(PSIS).Althoughthestartingpointcanbemodifiedor
the PSIS notched to allow burying of the screw head, implant prominence cannot be
completelyeliminated.Anotherdisadvantageistherequirementofanoffsetconnectorfor
segmentallumbosacralinstrumentation.
TranssacralIliacFixation
S2-Alar-IliacScrews
Developed to address the problematic implant prominence and offset location of iliac
screws, S2-alar-iliac (“S2-iliac”) screws are associated with a lower complication rate
relatedto implant prominence-relatedpain, necessitatingscrew removal, comparedwith
traditional iliacfixation.
11
 Implantprominence is minimized, withthe mean distance of
the insertion point to the skin 15 mm deeper for the S2-iliac technique compared with
traditionaliliac screwinsertionat thePSIS.
18
The S2-iliacscrewstarting pointis 2to4
mmlateraland 4to8mm caudaltothedorsal S1foramen,witha trajectorytowardthe
anterior inferioriliac spine (Fig.4.3a) atanangle of ~40 degrees lateraland20 to 30
degreescaudal.
11,18
Theiliactear-dropisagainemployedfortrajectoryalignment.Unlike
traditional iliac screws, S2-iliac screws do not typically require an offset connector for
joiningrodstolumbosacralpediclescrewconstructs(Fig.4.3b).Biomechanicaltestingof
S2-iliacscrewshasshownequivalentstabilitytoconventionaliliacscrews.
19
TheS2-iliac
screwtrajectory resultsin crossingthesacroiliac joint,which hasnot beenshown tobe
problematicinthefirst5yearsoffollow-upofthistechnique,butwhichrequiresongoing
surveillance(Fig.4.3c,d).Althoughhaloingaroundiliacscrewsmaybeobservedinover
25%ofpatients,iliacscrewpulloutorbreakageisveryrare.
1,11,14
AdjunctiveAnteriorInterbodySupport
Polly and colleagues
20
 found that load-bearing interbody structural grafts increase
construct stiffnessand therefore candecrease the strain onposterior instrumentation, in
additiontoincreasingthesurfaceareaavailable forarthrodesis.Theyalsofoundthatthe
locationof theinterbody graftin thesagittalplane hasbiomechanical significance,with
anteriorly placed grafts having increased stiffness compared with central or posteriorly
placed interbody grafts. Compared with stand-alone pedicle screw and combination
pedicle-iliac screw constructs, pedicle-iliac screw constructs combined with interbody
cages significantly reduce segmental movement across the lumbosacral junction in
laboratoryanalysis.
4
PatientPositioning
Patients undergoing sacral-pelvic instrumentation via open or minimally invasive
technique shouldbe positioned prone on anoperating table that enablesthecreation or
maintenanceofanatomiclumbarlordosis.Fixationofthelumbosacraljunctioninaflator