Добавил:
Sekretar
kiopkiopkiop18@yandex.ru
t.me/Prokururor I Вовсе не секретарь, но почту проверяю
Опубликованный материал нарушает ваши авторские права? Сообщите нам.
Вуз:
Предмет:
Файл:Ординатура / Хирургия / Библиотека им академика М.И. Перельмана / Книга_5835_Библиотеки_им_академика_М_И_Перельмана.pdf
X
- •Contents
- •Preface
- •1.1 Introduction
- •1.5 Free-Hand Scanning with Position Sensing
- •1.5.1 Tracked 3-D US with Articulated Arm Sensing
- •1.5.2 Free-Hand 3-D US with Acoustic Tracking
- •1.5.3 Free-Hand 3-D Scanning with Magnetic Field Sensing
- •1.5.4 3-D US Tracked by Speckle Decorrelation
- •1.6 Free-Hand 3-D US Scanning Without Position Sensing
- •1.7 2-D Array Scanning for Dynamic 3-D Ultrasound (4-D US)
- •1.8 3-D Ultrasound Visualization
- •1.8.1 Multiplanar Reformatting
- •1.8.2 Volume Rendering Techniques
- •1.9 3-D Ultrasound-Guided Prostate Therapy
- •1.2 Disadvantages of 2-D Ultrasound
- •1.3 3-D Ultrasound Scanning Techniques
- •1.4 Mechanical Scanning
- •1.4.1 Linear Mechanical 3-D Scanners
- •1.4.2 Tilt 3-D Mechanical Scanners
- •1.4.3 Endocavity Rotational 3-D Scanners
- •1.9.1 Early-Stage Prostate Cancer Management
- •1.9.2 US-Guided Prostate Brachytherapy
- •1.9.3 3-D TRUS-Guided Brachytherapy System
- •1.9.4 3-D TRUS Imaging System
- •1.9.5 Prostate Segmentation
- •1.9.5.1 Initialization
- •1.9.5.2 Refinement
- •1.9.5.3 Propagation
- •1.9.6 Dosimetry
- •1.9.7 Calibration of the Coordinate Systems
- •1.9.8 Needle Segmentation
- •1.10 Evaluation of 3-D TRUS-Guided Brachytherapy System
- •1.10.1 Methods of Calibration
- •1.10.1.1 Fiducial Localization Error
- •1.10.1.2 Fiducial Registration Error
- •1.10.1.3 Target Registration Error
- •1.10.2 Results of Calibration
- •1.10.3 Accuracy of Needle Placement
- •1.10.4 Accuracy of Needle Angulation
- •1.10.5 Accuracy of Needle Targeting
- •1.10.6 Accuracy of Needle Tracking
- •1.10.7 Accuracy of Seed Implantation
- •1.11 Conclusions
- •Acknowledgments
- •References
- •2.1 Introduction
- •2.2 Despeckle Filtering
- •2.2.1 Local Statistics Filtering
- •2.2.1.1 First-Order Statistics Filtering (lsmv, wiener)
- •2.2.1.2 Homogeneous Mask Area Filtering (lsminsc)
- •2.2.2 Median Filtering (median)
- •2.2.3 Maximum Homogeneity over a Pixel Neighborhood Filtering (homog)
- •2.2.4 Geometric Filtering (gf4d)
- •2.2.5 Homomorphic Filtering (homo)
- •2.2.6 Diffusion Filtering
- •2.2.7 Wavelet Filtering (waveltc)
- •2.3 Methodology
- •2.3.1 Material
- •2.3.2 Recording of Ultrasound Images
- •2.3.3 Despeckle Filtering
- •2.3.4 Texture Analysis
- •2.3.4.1 Statistical Features (SF)
- •2.3.4.2 Spatial Gray-Level Dependence Matrices (SGLDMs)
- •2.3.4.3 Gray Level Difference Statistics (GLDS) [44]
- •2.3.4.4 Neighborhood Gray Tone Difference Matrix (NGTDM) [45]
- •2.3.4.5 Statistical Feature Matrix (SFM) [46]
- •2.3.4.6 Laws Texture Energy Measures (TEM) [46]
- •2.3.4.7 Fractal Dimension Texture Analysis (FDTA) [46]
- •2.3.4.8 Fourier Power Spectrum (FPS) [46]
- •2.3.5 Distance Measures
- •2.3.6 Univariate Statistical Analysis
- •2.3.7 kNN Classifier
- •2.3.8 Image Quality Evaluation Metrics
- •2.3.9 Visual Evaluation by Experts
- •2.4 Results
- •2.4.1 Evaluation of Despeckle Filtering on a Symptomatic Ultrasound Image
- •2.4.2 Texture Analysis: Distance Measures
- •2.4.3 Texture Analysis: Univariate Statistical Analysis
- •2.4.4 Texture Analysis: kNN Classifier
- •2.4.5 Image Quality Evaluation Metrics
- •2.4.6 Visual Evaluation by Experts
- •2.5 Discussion
- •Acknowledgments
- •References
- •3.1 Introduction
- •3.1.1 Limitations of Conventional Carotid Ultrasound Imaging
- •3.2 3-D US Imaging of the Carotid Arteries
- •3.2.1 3-D Carotid Ultrasound Scanning Techniques
- •3.2.1.1 Mechanical Linear 3-D Carotid Ultrasound Imaging
- •3.2.2 Reconstruction of 3-D US Images
- •3.2.3 Viewing of 3-D US Images
- •3.3 Measurement of Plaque Volume
- •3.3.1 Plaque Segmentation by Manual Planimetry
- •3.3.8 Local Distribution and Change of Carotid Wall and Plaque
- •3.3.8.1 Reconstructing Surfaces from Polygonal Slices
- •3.3.8.2 3-D Maps of Average and Standard Deviation Carotid Surfaces
- •3.3.2 Studies of Plaque Volume
- •3.3.3 The Effects of Interslice Distance
- •3.3.4 The Accuracy of Plaque Volume Measurements
- •3.3.5 Variability of Plaque Volume Measurements
- •3.3.6 Automated Segmentation of Plaques from 3-D US Images
- •3.3.7 Plaque Surface Morphology
- •3.3.8.3 Vessel Wall Plus Plaque Thickness Map and Its Standard Deviation
- •3.3.8.4 3-D Maps of Carotid Wall Plus Plaque Thickness Change
- •3.3.9 Example Results
- •3.4 Trends and Future Developments
- •3.4.1 The Need for Improved Free-Hand Scanning
- •3.4.2 The Need for Improved Visualization Tools
- •3.4.3 Reduction in the Variability of Plaque Volume Measurement
- •3.4.4 ECG-Triggered Acquisition of 3-D Carotid US Images
- •Acknowledgments
- •References
- •4.1 Introduction
- •4.2 Methodology
- •4.2.1 Ultrasound Imaging Scanners
- •4.2.2 Material
- •4.2.3 Speckle Reduction
- •4.2.4 Image Normalization
- •4.2.5 Statistical and Texture Analysis
- •4.2.5.2 Spatial Gray-Level Dependence Matrix—Range of Values (SGLDM)
- •4.3 Image Quality and Evaluation Metrics
- •4.3.1 Normalized Mean-Square-Error
- •4.3.2 Normalized Root Mean-Square-Error
- •4.3.3 Normalized Error Summation in the Form of the Minkowski Metric
- •4.3.4 Normalized Geometric Average Error
- •4.3.5 Normalized Signal-to-Noise Ratio
- •4.3.6 Normalized Peak Signal-to-Noise Radio
- •4.3.7 Mathematically Defined Universal Quality Index
- •4.3.8 Structural Similarity Index
- •4.4 Visual Perception Evaluation
- •4.5 Results
- •4.6 Discussion
- •Acknowledgments
- •References
- •5.1 Ultrasound Imaging of the Carotid Wall
- •5.1.1 Carotid Artery Anatomy and Pathology
- •5.1.2 Principles and Validity of Ultrasound Analysis of the Carotid Artery
- •5.1.2.1 Normal Carotid Wall
- •5.1.2.2 Ultrasound Analysis of Plaques
- •5.2.1 Different Approaches for ROI Extraction
- •5.2.2 Approaches to Image Segmentation
- •5.3 Structure of the CULEX Algorithm
- •5.3.1 ROI Extraction
- •5.3.2 Segmentation of the Lumen and Carotid Wall
- •5.3.3 Notes About the CULEX Segmentation Strategy
- •5.4 CULEX Characterization and Image Databases
- •5.4.1 Percent Statistics Algorithm
- •5.4.2 Confidence Interval for the Average Segmentation
- •5.4.3 Segmentation Error
- •5.4.4 Image Database and Ultrasound Equipment
- •5.5 ROI Detection and Robustness to Noise
- •5.6.1 Absolute Segmentation Errors and IMT Measurements
- •5.6.2 Percent Statistics
- •5.6.3 Confidence Interval for the Mean Segmentation
- •5.7 Plaque Imaging
- •5.7.1 Stable Plaques
- •5.7.2 Unstable Plaques (Echolucent Type II)
- •5.8 Discussion and Conclusions
- •References
- •6.1 Introduction
- •6.2 Level Set Segmentation Method
- •6.2.1 Basic Level Set Theory
- •6.2.2 Summary of Level Set Theory
- •6.3 Proposed Architecture for the CAD System
- •6.3.1 Data Acquisition
- •6.3.2 Preprocessing Subsystem Architecture
- •6.3.2.1 Anisotropic Diffusion Filtering
- •6.3.2.2 Image Enhancement Via Sigmoid Mapping
- •6.3.3 Segmentation Subsystem Based on the Level Set Framework
- •6.3.4 Beam Angle Statistics
- •6.3.5 Similarity Between Shapes: A Classification Strategy
- •6.3.5.1 Best-Fit Ellipse Computation
- •6.3.5.2 Similarity Measurement Between a True Lesion and a Fitted Lesion
- •6.4 Experimental Protocol, Data Analysis, and Performance Evaluation
- •6.4.1 Similarity Measure Analysis
- •6.4.2 Performance Evaluation
- •6.5 Discussion
- •6.5.1 Discussion About the Dual Level Set
- •6.5.2 Discussion About the Similarity Measure
- •6.5.3 Discussion About Threshold Selection
- •6.6 Conclusion and Future Works
- •References
- •7.1 Introduction
- •7.2 Review of the 2-D Continuous Strain Imaging System
- •7.3 Proposed Architecture of the 3-D Strain Imaging System
- •7.3.1 Data Acquisition
- •7.3.2 Image Enhancement Via Sigmoid Mapping
- •7.3.3 Segmentation Subsystem Based on the Level Set Framework
- •7.3.3.1 Basic Theory of the Level Set
- •7.3.3.2 3-D Strain Imaging and Segmentation
- •7.3.4.1 Normalized Volume Difference
- •7.3.4.2 Normalized Shape Difference
- •7.3.4.3 Normalized Contour Difference
- •7.3.4.4 Shift Distance
- •7.4 Experimental Protocol, Data Analysis, and Results
- •7.4.1 2-D and 3-D Experimental Protocols
- •7.4.2 Segmentation Results
- •7.4.3 Classification Strategy Using ROC Curves and SVM
- •7.4.4 Figure of Merit for 2-D Versus 3-D: Performance Evaluation
- •7.5 Discussions
- •7.5.1 Discussion About the Level Set Framework
- •7.5.2 Discussion About Strain Features
- •7.5.3 Discussion About 3-D Versus 2-D Strain Methods
- •7.6 Conclusion
- •References
- •8.1 Introduction
- •8.2 Related Works
- •8.2.1 Breast Cancer Diagnosis with Autocorrelation Matrix
- •8.2.2 Solid Breast Nodules with Neural Networks
- •8.3 Theoretical Background
- •8.3.1 Tsallis Entropy
- •8.3.2 The Nonextensive Segmentation Approaches
- •8.3.2.1 Nonextensive Segmentation Algorithm for Image Binarization
- •8.3.2.2 The Nonextensive Segmentation Recursive Algorithm
- •8.3.2.3 The Level Set Formulation
- •8.3.2.4 The Support Vector Machine Theory
- •8.3.3 Morphological Chains: Mathematical Morphology Definitions
- •8.4 The Proposed Five-Step Methodology
- •8.5 Performance Evaluation
- •8.6 Discussion and Conclusions
- •Acknowledgments
- •References
- •9.1 Real-Time 3-D Echocardiography
- •9.2 Anisotropic Diffusion
- •9.3.1 Correlation-Based Optical Flow
- •9.3.2 3-D Ultrasound Datasets
- •9.3.3 Surface Tracing
- •9.3.4 Surface Tracking with Optical Flow
- •9.3.5 Evaluation
- •9.3.6 Results
- •9.3.6.1 Dog Data
- •9.3.6.2 Clinical Data
- •9.4 Dynamic Cardiac Information from Optical Flow
- •9.4.1 Coordinate Systems
- •9.4.2 Dynamic Cardiac Information Measurements
- •9.4.3 Data
- •9.4.4 Results and Discussion
- •9.4.5 Discussion About Estimation of the Myocardial Field
- •9.5 Summary
- •Acknowledgments
- •References
- •10.1 Introduction
- •10.1.1 Left Ventricular Systolic Dysfunction
- •10.1.2 Determinants of LV Systolic Performance
- •10.2 Assessment of Left Ventricular Function—An Overview
- •10.2.1 Ejection Phase Indices
- •10.2.1.1 Ejection Fraction and Fractional Shortening
- •10.2.1.2 Myocardial Performance Index
- •10.2.2 Isovolumetric Indices
- •10.2.3 Pressure-Volume Analysis
- •10.2.3.1 End Systolic Pressure-Volume Relationships (ESPVR)
- •10.2.3.2 Stroke Work
- •10.2.3.3 Preload Recruitable Stroke Work
- •10.2.4 Left Ventricular Stress Strain Relationship
- •10.3 Echocardiographic Examinations
- •10.3.1 Echocardiographic Measurements and Calculations
- •10.3.1.1 Echocardiographic Measurement of Left Ventricular Volume
- •10.3.1.2 Left Ventricular dp/dt
- •10.3.1.3 Left Ventricular End-Systolic Wall Stress
- •10.3.1.4 Left Ventricular Forward Stroke Volume and Cardiac Output
- •10.3.1.5 Mitral Regurgitant Volume
- •10.3.1.6 Wall Motion Index
- •10.3.1.7 Mitral Annulus Motion
- •10.3.2 Real-Time Left Ventricular Volume by Automated Boundary Detection
- •10.4 Left Ventricle Systolic Dysfunction Identification
- •10.4.1 Delineation of Left Ventricle
- •10.4.2 Quantification of Systolic Dysfunction
- •10.4.3 Region of Dysfunction Identification
- •10.4.3.1 Centerline Method
- •10.4.3.2 Color Kinesis Method
- •10.4.3.3 Anatomic M-Mode
- •10.4.3.4 Radial Line Method
- •10.4.3.5 Regional Area Method
- •10.5 Real-Time 3-D Echocardiography
- •10.5.1 Sparse Array Transducer
- •10.5.2 Full Matrix Array
- •10.5.3 Real-Time Volume Rendered 3-D Imaging
- •References
- •11.1 Introduction
- •11.2 Origin of Heart Sounds
- •11.2.1 Auscultatory Areas
- •11.2.2 Rate and Rhythm
- •11.2.3 Normal Heart Sounds
- •11.2.3.1 First Heart Sound (S1)
- •11.2.3.2 Second Heart Sound (S2)
- •11.2.3.3 Third Heart Sound (S3)
- •11.2.3.4 Fourth Heart Sound (S4)
- •11.2.4 Abnormal Heart Sounds
- •11.2.4.1 Abnormal S1
- •11.2.4.2 Abnormal S2
- •11.2.5 Murmur Classifications
- •11.2.5.1 Murmur Mechanisms
- •11.2.7 Gallop Sounds
- •11.2.8 Clicks
- •11.2.9 Opening Snaps
- •11.2.9.1 Tricuspid Valve Opening Snap
- •11.2.9.2 Mitral Valve Opening Snap
- •11.2.9.3 Differential Diagnosis of MVOS Versus S3 Gallop
- •11.2.9.4 Differential Diagnosis of MVOS Versus Splitting of S2
- •11.2.10 Maneuvers
- •11.3 Phonocardiograph
- •11.3.2 Amplifier
- •11.3.1 Instrument Description
- •11.3.1.1 Transducer
- •11.3.3 Filter
- •11.3.4 Analysis
- •11.3.5 Segmentation of S1 and S2
- •11.3.5.1 Blind Source Separation
- •11.3.5.2 Complexity-Based Gating
- •11.3.6 Decomposition of PCG
- •11.3.7 Short-Term Fourier Transform
- •11.3.8 Continuous Wavelet Transform
- •11.3.8.1 Resolution
- •11.3.9 Wigner Distribution
- •11.3.10 The Choi-Williams Distribution
- •11.3.11 Autoregressive Modeling
- •11.3.12 Feature Extraction
- •11.3.13 Classification
- •11.3.13.1 Neural Networks
- •11.3.13.2 Fuzzy Systems
- •11.3.13.3 Wavelet Method
- •References
- •12.1 Level Set Method
- •12.1.1 Front Evolution
- •12.1.2 Boundary Value Formulation
- •12.1.3 Initial Value Formulation
- •12.1.4 Applications of Level Set Method
- •12.2 Active Contours in Level Set Framework
- •12.2.1 Front Evolving Geometric Models of Active Contours
- •12.2.2 Geodesic Active Contour Models
- •12.2.3 Tuning Geometric Active Contour with Regularizers
- •12.2.3.1 Clustering-Based Regularizers
- •12.2.3.2 Bayesian-Based Regularizers
- •12.2.3.3 Shape-Based Regularizers
- •12.2.3.4 Coupling-Surfaces Regularizers
- •12.2.4 Region-Based Active Contour Models
- •12.2.4.1 Mumford-Shah (MS) Function
- •12.2.4.2 The Level Set Approach to Solving the Mumford-Shah Function
- •12.3 Fully Automated 3-D Prostate Segmentation from Transrectal Ultrasound (TRUS) Images
- •12.3.1 3-D Shape Prior Extraction
- •12.3.2 Intensity Prior Extraction
- •12.3.3 Segmentation in Bayesian Interface
- •12.4 Evaluation of the System Performance
- •12.4.1 Transrectal Ultrasound Images
- •12.4.2 Validation Method
- •12.5 Results
- •12.6 Conclusions and Future Work
- •References
- •13.1 Introduction
- •13.2 Recent Developments in HIFU and Therapy Planning
- •13.2.1 HIFU Applications
- •13.2.2 HIFU Therapy Guidance
- •13.2.3 HIFU Transducers and Instrumentation
- •13.2.4 Theoretical and Experimental Study of the HIFU Mechanism
- •13.2.5 HIFU Dosimetry and Therapy Planning
- •13.3 Generalized Strategies for HIFU Therapy Planning
- •13.3.1 Overview of Generalized Strategy
- •13.3.2 Pretreatment Imaging
- •13.3.3 Defining the Target and Surrounding Tissues
- •13.3.4 Simulation of HIFU
- •13.3.5 Integration and Visualization
- •13.3.6 Planning of HIFU Delivery and Control
- •13.3.7 Overall Software Design and Integration of Tools
- •13.3.8 Validation and Clinical Use of the HIFU Therapy Planning System
- •13.4 Challenges and Work Ahead
- •Acknowledgments
- •References
- •14.1 Introduction to HIFU
- •14.2 Ultrasonic System and Various Measurement Systems
- •14.2.1 Attenuation Measurement
- •14.2.2 Ultrasonic System
- •14.2.3 Acoustical Monitoring of Cavitation
- •14.2.4 Software
- •14.2.5 Acoustical Field Measurement
- •14.2.6 In Vitro Experiments
- •14.2.7 In Vivo Experiments
- •14.3 Simulation Model
- •14.3.1 Estimation of Temperature
- •14.3.2 Estimation of Thermal Dose
- •14.3.3 Estimation of Lesion Size
- •14.3.4 Effect of Attenuation
- •14.4 Attenuation Measurement as a Function of Thermal Dose
- •14.4.1 Results of Attenuation Versus Thermal Dose
- •14.4.2 Simulation Results Using Variable Attenuation
- •14.5 Kidney Ablation
- •14.5.1 Results
- •14.6 Kidney Ablation Under MRI Guidance
- •14.6.1 HIFU Parameters
- •14.6.2 MRI Parameters
- •14.6.3 Results
- •14.7 Liver Ablation
- •14.7.1 HIFU Parameters
- •14.7.2 MRI Analysis
- •14.7.3 Results
- •14.8 Effect of Interfaces in HIFU Ablation
- •14.8.1 MRI Analysis
- •14.8.2 Results
- •References
- •15.1 Introduction
- •15.2 Thermal Ablation Mechanisms
- •15.2.1 Hyperthermia and Ablation
- •15.2.2 Cryoablation
- •15.2.3 Chemical Ablation
- •15.3 Therapeutic Modalities for Thermal Ablation
- •15.3.1 RF Ablation
- •15.3.2 Microwave Ablation
- •15.3.3 Laser Thermal Ablation
- •15.3.4 Focused Ultrasound-Based Ablation
- •15.4 Focal Ultrasound Surgery Robots—FUSBOTs
- •15.5 Concluding Remarks
- •References
- •About the Editors
- •List of Contributors
- •Index

behaves like a human operator in segmenting the distal carotid wall in our image
database.
The corresponding values for the near wall were equal to 0.514 for the
lumen–intima interface and 0.3 for the media–adventitia interface. This latter inter-
face is the only one that did not pass the statistical test. Results are in line with the
measurements of the segmentation error: the greater difficulties can be found in the
outlining of the near wall media–adventitia border. The third column of Table 5.1
reports the results for this test.
To our knowledge, none of the previously referenced algorithms for the carotid
artery segmentation were tested by means of the Percent Statistics algorithm; hence,
a direct comparison of the performances is impossible. However, we believe this test
is important because in many practical applications (i.e., image reconstruction,
image fusion, carotid wall texture analysis) it is more important to know that the
CGBs are not different from those obtained by experts than to have a low segmenta-
tion error. Our algorithm passed this statistical test, even though p value was
extremely close to the limit of the acceptance region. Clearly, we are working to
increase the number of human operators segmenting our sample database, since this
would enforce the strength of the statistical test.
5.6.3 Confidence Interval for the Mean Segmentation
Figure 5.17 represents the distribution of the results for the confidence interval. The
CGB was tested against the average segmentation of the four humans. The bars rep-
resent the percentage of times the CGB falls within the confidence interval (
0.05)
for the average LI profiles (left graphs, far wall at the top, near wall at the bottom)
and MA profiles (right graphs, far wall at the top, near wall at the bottom). The
number of tested points was 10,000 (50 points per image). The probability of falling
into the 95% CI for the average segmentation was always quite high, and no signifi-
cant differences were found among LI
NW
, LI
FW
, and MA
FW
in terms of CULEX seg-
mentation. Once again, however, the MA
NW
interface was more problematic; Figure
5.17 shows, in the bottom right histogram, that in 40% of the cases, 40% or fewer
of the pixels fell into the CI. In fact, due to the characteristics of the ultrasound
images, the near wall media–adventitia layer is often difficult to track, even for a
trained expert. At present, our algorithm is capable of performing a segmentation
that is reliable, but it overestimates the real position of the MA
NW
border.
Finally, Figure 5.18 shows an example of segmentation with the CIs overlapped.
Note that, in this image, nearly the 100% of the points of the CGBs are within the
95% CI of the average manual segmentations.
This test is a further step toward ensuring that CULEX performs reasonably like
a human expert when segmenting the CCA walls.
5.7 Plaque Imaging
The availability of a user-independent technique for the segmentation of carotid
wall plaques is of paramount importance in clinical practice as well as in the engi
-
neering field. In fact, most of the time, the segmentation of a plaque is a preliminary
134 User-Independent Plaque Segmentation

5.7 Plaque Imaging 135
Figure 5.18 Example of CULEX segmentation and of the 95% CI. The white lines represent the
borders traced by CULEX; the dashed white lines represent the 95% CI. In this example, nearly
100% of the pixels fall into the CI.
0
0 0.1 0.2
0.3
0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 0.1 0.2
0.3
0.4 0.5 0.6 0.7 0.8 0.9 1.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
LI - near wall MA - near wall
LI - far wall MA - far wall
Percentage of CGB pixels
falling into the CI
Percentage of CGB pixels
falling into the CI
Frequencies (%)
Frequencies (%)
Figure 5.17 Distribution of the pixels falling into the 95% CI for the four interfaces. The abscissa
represents the percentage of pixels falling into the 95% CI in a given image; the bars report the
percentage frequencies over 200 images. The mean percentage values were 92% for the LI
NW
, 81%
for the LI
FW
, and 85% for the MA
FW
interface. The MA
NW
interface presents an average value equal to
52%, confirming that this specific border is the most difficult to track by means of our technique.

step for the application of some other analysis technique, ranging from 3-D morpho-
logical reconstruction to plaque classification. CULEX proved suitable for segment-
ing both fibrous and echolucent type II plaques. We tested CULEX on our second
database, consisting of 100 images of plaques and thickened carotid walls.
When in presence of increased IMT, CULEX provided performances that were
statistically equal to the case of normal carotid wall. ROI selection was effective on
all 30 images in the database, with segmentation errors comparable to the normal
case.
5.7.1 Stable Plaques
Figure 5.19 depicts the CULEX segmentation of an image containing fibrous
plaques. The left panel of the upper row depicts the original image; the right panel
depicts the CULEX segmentations. The image is relative to a subject showing an
important plaque located on the proximal wall (as indicated by the large white
arrows); the far wall is comparable to a normal wall. This image indicates that
CULEX correctly characterizes plaque on the near wall and segment of the distal
wall.
We would like to remark once again that this segmentation is completely user
independent, and the four profiles are extracted in a single shot, without the need to
136 User-Independent Plaque Segmentation
MA
FW
MA
NW
LI
FW
LI
NW
MA
FW
CCA
CCA
JV
JV
MA
NW
LI
FW
LI
NW
Figure 5.19 CULEX segmentation of stable plaques. The upper row shows the case of a fibrous
plaque located on the near CCA wall; the lower row shows a CCA with a distal and a proximal
plaque. Left images are the raw ultrasound B-mode images. Large white arrows point to plaques.
The right images report CULEX segmentation of the plaques, where we can see that this technique
allows for excellent characterization of the plaque profile.

tune the algorithm or select parameters. Specifically, in this image, CULEX was
capable of segmenting contemporarily a plaque and a normal carotid wall.
The left panel of the lower row in Figure 5.19 shows two fibrous plaques: one
on the near wall and one on the far wall. Again, CULEX was able to characterize
plaques (right image).
To determine how CULEX performed on the plaque database, we calculated
the percentage of misclassified pixels in relation to the total number of pixels corre-
sponding to plaque (i.e., an error expressed as percentage of misclassification over
the plaque area). For the 30 images constituting our database, we found an error
equal to 8% ± 5% (mean ± STD).
We also compared the maximum stenosis diameter of the CCA lumen as
detected by CULEX and compared it to the one derived from human tracings; we
found a relative error lower than 1% (STD = 1%).
In this case too, a direct comparison of the CULEX performances with previous
proposed techniques is not possible. Some approaches are not suitable for plaque
characterization [14, 15], whereas other algorithms fail to segment proximal wall
malformations [16]. Besides being completely user independent, our approach
allows for direct extraction of a plaque contour, independent of its location.
5.7.2 Unstable Plaques (Echolucent Type II)
Figure 5.20 illustrates the CULEX segmentation of two echolucent plaques located
on the distal CCA wall. The left panel shows the raw images, whereas the right
panel depicts the segmentations. Note that echolucent type II plaques can also be
correctly characterized by our technique. Of the 40 images in our database, the seg-
mentation error was equal to 12% ± 4% (mean ± STD). The difference between
maximum the stenotic diameter was, in this case, about 10% (STD = 3%).
The development of an algorithm capable of also segmenting echolucent
plaques poses a problem of SNR. Specifically, if the image is too noisy or character-
ized by excessive blood backscattering, the lumen–intima interface segmentation
may become difficult. Some pixels belonging to the lumen, in fact, could be classi-
fied as plaque due to the fact that they represent light-gray spots in the black of the
vessel lumen. Similarly, pixels belonging to an echolucent plaque may be classified
as lumen if the SNR is poor. A partial solution could be to filter the image, but such
an operation enhances the signal power, but decreases the image detail and con-
trast, resulting in greater bias in the automatically segmented profiles. Hence, to
correctly segment echolucent plaques, the image must be of good quality.
Again, no other technique that we are aware of allows for the segmentation of
echolucent plaques in a user-independent fashion. Most of the previously described
techniques are not capable of distinguishing echolucent plaques from image noise
[14–16]. Hence, despite a segmentation error that is of the order of one-tenth of the
plaque area, our approach allows for the individuation and characterization of
echolucent plaques withoutbeing instructed by the user. It must be considered, also,
that with this structure it is possible to segment a CCA ultrasound image in a com-
pletely blind fashion: CULEX proved suitable for normal scans as well as for
pathological carotid images.
5.7 Plaque Imaging 137

5.8 Discussion and Conclusions
The CULEX algorithm can be proficiently used for the segmentation of ultrasound
images of the common carotid artery wall. This algorithm has the advantage of
being completely user independent; that is, the raw US image in DICOM format can
be processed without any interaction with the operator. Moreover, the CULEX
algorithm is able to characterize both echogenic and echolucent plaques in the
carotid wall. Pixel fuzziness and user independence are preserved and the obtained
IMT design is extremely close to the gold-standard tracing.
On normal carotids, the characterization of the algorithm showed that the con-
tour traced by the CULEX is statistically comparable to that of a human trained
operator. Moreover, the average error the algorithm commits in segmenting the
lumen–intima and the media–adventitia interfaces is lower than 1 pixel for the far
wall, equal to 1.2 pixels for the lumen–intima interface of the near wall, and equal to
2.1 pixels for the media–adventitia layer of the near wall.
When estimating the IMT, the average error is equal to 9%: note that this per
-
formance is in line with that obtained by means of user-dependent techniques.
138 User-Independent Plaque Segmentation
MA
FW
MA
NW
LI
FW
LI
NW
MA
FW
CCA
CCA
JV
JV
MA
NW
LI
FW
LI
NW
Figure 5.20 CULEX segmentation of unstable plaques. The upper row shows the case of a big
echolucent type II plaque located on the near CCA wall; the lower row shows a plaque image in
which the operator fixed four markers for the delimitation of the plaque area. The images in the
left panel are the raw ultrasound B-mode images. Large white arrows point to plaques. The images
on the right depict CULEX segmentation of the plaques, in which we can see that this technique
allows for excellent characterization of the plaque profile. Specifically, the percentage of
misclassified pixels with respect to the plaque area is lower than 9% in these examples.

On stable plaques and on increased IMT images, the CULEX algorithm per-
formed a segmentation substantially equal to that obtained on normal images.
When processing echolucent plaques, the segmentation error increased slightly
because of the weak difference in gray tones between pixels belonging to the wall
and pixels belonging to the lumen.
This algorithm is a step forward in the completely automatic detection of the LI
and MA interfaces in an ultrasound B-mode carotid scan, suitable for healthy as
well as pathological subjects.
One of the major advantages of this technique, in fact, is that it can also be used
in presence of pathology. The algorithm proved effective in automatically detecting
and segmenting echolucent type II plaques, echogenic plaques, and carotid walls
with increased IMT. Despite a small bias in the estimation of the plaque dimensions,
we found the performance of our algorithm to be extremely useful for the assess-
ment of the carotid media layer, as a computer aid to the early diagnosis of wall
degeneration in asymptomatic patients.
This system may be extremely helpful when segmentation is just a preliminary
step for further processing such as coregistration with other imaging techniques,
3-D reconstruction, and carotid wall assessment. As an example, this automatic
algorithm could be used for plaque identification before performing plaque texture
analysis, especially when the effects of several image processing steps need to be
validated.
The results are very promising and the system is being integrated into clinical
setups for automatic pathological carotid wall analysis.
References
[1] Touboul, J. P., et al., “Carotid Intima-Media Thickness, Plaques, and Framingham Risk
Score as Independent Determinants of Stroke Risk,” Stroke, Vol. 36, No. 8, 2005,
pp. 1741–1745.
[2] Watanabe, T., et al., “Small Dense Low-Density Lipoprotein and Carotid Atherosclerosis
in Relation to Vascular Dementia,” Metabolism, Vol. 53, No. 4, 2004, pp. 476–482.
[3] Gray, H., Gray’s Anatomy: Anatomy of the Human Body, Philadelphia, PA: Lea &
Febiger, 1918.
[4] Steinberg, D., “An Interpretive History of the Cholesterol Controversy: Part I,” J. Lipid
Research, Vol. 45, 2004, pp. 1583–1593.
[5] el-Barghouti, N., et al., “The Relative Effect of Carotid Plaque Heterogeneity and
Echogenicity on Ipsilateral Cerebral Infarction and Symptoms of Cerebrovascular Dis-
ease,” Int. Angiol., Vol. 15, 1996, pp. 300–306.
[6] Sabetai, M. M., et al., “Carotid Plaque Echogenicity and Types of Silent CT-Brain Infarcts.
Is There an Association in Patients with Asymptomatic Carotid Stenosis?” Int. Angiol.,
Vol. 20, 2001, pp. 51–57.
[7] Pignoli, P., et al., “Intimal Plus Medial Thickness of the Arterial Wall: A Direct Measure-
ment with Ultrasound Imaging,” Circulation, Vol. 74, 1986, pp. 1399–1406.
[8] Molinari, F., et al., “Characterization of a Completely User-Independent Algorithm for
Carotid Artery Segmentation in 2-D Ultrasound Images,” IEEE Trans. on Instrum. &
Meas., Vol. 56, No. 4, 2007.
[9] Wendelhag, I., et al., “Ultrasound Measurement of Wall Thickness in the Carotid Artery:
Fundamental Principles and Description of a Computerized Analysing System,” Clin.
Physiol., Vol. 11, 1991, pp. 565–577.
5.8 Discussion and Conclusions 139

[10] Gray-Weale, A. C., et al., “Carotid Artery Atheroma: Comparison of Preoperative B-Mode
Ultrasound Appearance with Carotid Endarterectomy Specimen Pathology,” J. Cardiovasc.
Surg., Vol. 29, 1988, pp. 676–681.
[11] Suri, J. S., et al., Plaque Imaging: Pixels to Molecular Levels, Amsterdam: IOSPress, 2005.
[12] Christodoulos, C. I., et al., “Texture-Based Classification of Atherosclerotic Carotid
Plaques,” IEEE Trans. on Medical Imaging, Vol. 22, No. 7, 2003, pp. 902–912.
[13] Widder, B., et al., “Morphological Characterization of Carotid Artery Stenoses by Ultra-
sound Duplex Scanning,” Ultrasound Med. Biol., Vol. 16, No. 4, 1990, pp. 349–354.
[14] Liguori, C., A. Paolillo, and A. Pietrosanto, “An Automatic Measurement System for the
Evaluation of Carotid Intima-Media Thickness,” IEEE Trans. on Instr. and Meas., Vol. 50,
2001, pp. 1684–1691.
[15] Gutierrez, M. A., et al., “Automatic Measurement of Carotid Diameter and Wall Thickness
in Ultrasound Images,” Computers in Cardiology, Vol. 29, 2002, pp. 359–362.
[16] Cheng, D., et al., “Using Snakes to Detect the Intimal and Adventitial Layers of the Com-
mon Carotid Artery Wall in Sonographic Images,” Computer Methods and Programs in
Biomedicine, Vol. 67, 2002, pp. 27–37.
[17] Touboul, P. J., et al., “Use of Monitoring Software to Improve the Measurement of Carotid
Wall Thickness by B-Mode Imaging,” J. Hypertens., Vol. 10, No. 5 (Suppl.), July 1992,
pp. S37–S41.
[18] Gustavsson, T., et al., “Implementation andComparison of FourDifferent Boundary Detec-
tion Algorithms for Quantitative Ultrasonic Measurements of the Human Carotid Artery,”
IEEE Computers in Cardiology, Vol. 24, 1997, pp. 69–72.
[19] Liang, Q., et al., “A Multiscale Dynamic Programming Procedure for Boundary Detection
in Ultrasonic Artery Images,” IEEE Trans. on Medical Imaging, Vol. 19, 2000,
pp. 359–369.
[20] Lobregt, S., and M. Viergever, “A Discrete Dynamic Contour Model,” IEEE Trans. on
Medical Imaging, Vol. 14, 1995, pp. 12–24.
[21] Delsanto, S., etal., “CULEX—Completely User-Independent Layers EXtraction: Ultrasonic
Carotid Artery Images Segmentation,” 27th Annual International Conference of the IEEE
EMBS, Shanghai, China, September 2005.
[22] Xu, C., and J. L. Prince, “Snakes, Shapes, and Gradient Vector Flow,” IEEE Trans. on
Image Processing, Vol. 7, 1998, pp. 359–369.
[23] Soille, P., Morphological Image Analysis: Principles and Applications, Berlin:
Springer-Verlag, 1999, pp. 173–174.
[24] Chalana, V., and Y. Kim, “A Methodology for Evaluation of Boundary Detection Algo-
rithms on Medical Images,” IEEE Trans. on Medical Imaging, Vol. 16, 1997,pp. 642–652.
[25] Alberola-Lòpez, C., M. Martìn-Fernandez, and J. Riuz-Alzola, “Comments on: A Method-
ology for Evaluation of Boundary Detection Algorithms on Medical Images,” IEEE Trans.
on Medical Imaging, Vol. 23, 2004, pp. 658–659.
[26] Bruckhardt, C. B., “Speckle in Ultrasound B-Mode Scans,” IEEE Trans. on Sonics
Ultrason., Vol. SU-25, No. 1, 1978, pp. 1–6.
[27] Delsanto, S., et al., “Characterization of a Completely User-Independent Algorithm for the
Segmentation of Carotid Artery Ultrasound Images,” IEEE Instrumentation and Measure-
ment Technology Conference (IMTC), Sorrento, Italy, April 2006.
140 User-Independent Plaque Segmentation

PART III
2-D/3-D Breast Ultrasound Imaging


CHAPTER 6
Breast Lesion Classification Using 3-D
Ultrasound
Ruey-Feng Chang, Chii-Jen Chen, Kau-Yih Chiou, Woo Kyung Moon, Dar-Ren
Chen, and Jasjit S. Suri
6.1 Introduction
Breast cancer is a progressive disease, and the probability of developing invasive
breast cancer in women is not the same at different age intervals [1]. According to
recent studies [2, 3], early detection of breast cancer can reduce morbidity and mor-
tality rates. In the past, mammography has been the most widely used screening
modality, but it has a low false-negative rate [4]. False-negatives can be attributed to
the existing technological limitations of mammography, human error, and quality
assurance failures. Many researchers have found that only 5.1% of malignancies
(193 of 3,753) were detected in women with an abnormal or benign finding on the
mammogram [5]. Recently, it has been shown that the rates of false-negatives can
be reduced by using a different modality, such as ultrasound [6].
Because ultrasound is widely available and relatively inexpensive to perform, it
has become a valuable diagnostic adjunct to mammography [7–9]. Zonderland et
al. [10] reported a sensitivity of 91% and specificity of 98% for ultrasound com-
pared to mammography (83% and 97%, respectively) based on their experiment.
Although different ultrasound operators can produce different US images, ultra-
sound is still preferred due to its convenience, noninvasiveness, and low cost. To
reduce the effect of operator dependence in ultrasound, several computerized meth-
ods have been proposed to help the classification between benign and malignant
tumors [11–18].
The general idea of computer-aided diagnosis (CAD) has been developed to
assist physicians in diagnosing ultrasonic abnormalities suspicious for breast can-
cer. With the assistance of CAD, physicians can efficiently detect lesions, such as
spiculations, and discriminate more accurately between begin and malignant
tumors [11, 16, 19–25]. Sawaki et al. [11] proposed a CAD system that uses fuzzy
inference for breast sonography and adopted six different criteria to classify lesions:
lesion shape, border, edge shadows, internal echoes, posterior echoes, and halo.
However, their system’s accuracy, sensitivity, and specificity were only 60.3%,
82.1%, and 42.9%, respectively.
143
Соседние файлы в папке Библиотека им академика М.И. Перельмана
