Добавил:
kiopkiopkiop18@yandex.ru t.me/Prokururor I Вовсе не секретарь, но почту проверяю Опубликованный материал нарушает ваши авторские права? Сообщите нам.
Вуз: Предмет: Файл:

Ординатура / Хирургия / Библиотека им академика М.И. Перельмана / Книга_3820_Библиотеки_им_академика_М_И_Перельмана

.pdf
Скачиваний:
0
Добавлен:
15.09.2026
Размер:
15 Мб
Скачать
☆
CHAPTER 15 Transapical valve technology for aortic stenosis 183
https://t.me/med1917
Coronary obstruction
Coronary obstruction might occur if the valve frame or the sealing cuff is placed directly over a coronary ostium, which is, however, exceedingly rare. Of more concern is the possibility of displacing a bulky, calcified native leaflet over a coronary ostium. Although this is potentially fatal, some cases have been successfully managed by immediate percutaneous angioplasty on emer­gently placed cardiopulmonary bypass [43]. The risk of coronary occlusion is usually low although difficult to predict. It most likely depends on the bulkiness of the native leaflets, height of the coro­nary ostium from the annulus, and the dimension of the sinus of Valsalva which can be assessed by MSCT [65].
Annular and root rupture
Rupture of the aortic annulus is a rare complication of TAVI with subsequent hemodynamic collapse. Excessive balloon dilation and aggressive valve oversizing in combination with the presence of extensive annular (especially subcommissural) calcification might increase the likelihood of annular rupture. A tear created at the level of the valve inflow can result in a ventricular septal defect or left ventricular-to-left atrial shunt, whereas a root rupture will likely cause cardiac tamponade requiring emergent cardiopulmonary bypass and surgical repair [58].
Future evolution of TAVR and new devices
Since the results of the first randomized trials (PARTNER trial) are published comparing a cohort of patients with severe aortic stenosis treated with TAVI and standard medical therapy, and with the expectation that technology is definitely to improve within the next few years, the indication for TAVI is likely to shift to a younger population [66,67]. However, controlled randomized clinical trials will be required beforehand. The interdisciplinary nature of TAVR, combining aspects of both surgical and interventional therapies, presents special chal­lenges and requires an enlightened and collabora­tive approach to the development of clinical research recommendations and endpoint definitions. The VARC (Valve Academic Research Consortium)
initiative has been founded in an attempt to achieve the necessary consensus among the various subspe­cialties, such that this innovative treatment modality may be evaluated objectively and according to prac­tical endpoint definitions [68].
Another interesting population are patients with degenerated xenografts. While this problem is less frequent with the current generation of biologic valves, the trend for implantation in younger patient groups will generate an increasing patient cohort requiring a second operation. Redo AVR can be performed with excellent results, but alternative techniques may further decrease the risks associated with redo aortic valve surgery. Especially after root replacement, redo AVR can be challenging. A few studies demonstrated that for both mitral and aortic valve xenografts TAVR can be performed suc­cessfully. The so-called valve-in-valve concept makes useof the stent of the implanted xenograft that serves as a marker during implantation of the transcatheter valve [69–71]. This concept has also already been applied in an experimental setting as valve-in-a-ring for late mitral valve replacement after late failure of mitral valve repair [71]. Another promising approach is the transcatheter placement of autologous tissue engineered valved stents. A proof of concept has recently been demonstrated. This approach may have impor­tant implications for the correction of congenital cardiac malformations [72].
In the absence of randomized trials and the few data on matched comparisons showing similar results for TAVR as for patients undergoing conventional surgery [28], TAVR can currently be considered an alternative approach for selected high-risk patients with severe aortic stenosis.
References
1 Vahanian A, Alfieri OR, Al-Attar N, et al. Transcatheter
valve implantation for patients with aortic stenosis: a posi­tion statement from the European Association of Cardiothoracic Surgery (EACTS) and the European Society of Cardiology (ESC), in collaboration with the European Association of Percutaneous Cardiovascular Interventions (EAPCI). Eur J Cardiothorac Surg 2008;34:1–8.
2 Walther T, Chu MW, Mohr FW. Transcatheter aortic valve
implantation: time to expand? Curr Opin Cardiol 2008;23:111–16.
184 PART II Structural heart disease
https://t.me/med1917
3 Cribier A, Eltchaninoff H, Bash A, et al. Percutaneous
transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description. Circulation 2002;106:3006–8.
4 Lindroos M, Kupari M, Heikkilä J, et al. Prevalence of
aortic valve abnormalities in the elderly: an echocardio­graphic study of a random population sample. J Am Coll Cardiol 1993;21:1220–5.
5 Otto CM, Lind BK, Kitzman DW, et al. Association of
aortic-valve sclerosis with cardiovascular mortality and morbidity in the elderly. N Engl J Med 1999;341:142–7.
6 Aronow WS, Ahn C, Kronzon I. Association of val-
vular aortic stenosis with symptomatic peripheral arterial disease in older persons. Am J Cardiol 2001;88:1046–7.
7 Agmon Y, Khandheria BK, Jamil Tajik A, et al.
Inflammation, infection, and aortic valve sclerosis: Insights from the Olmsted County (Minnesota) population. Atherosclerosis 2004;174:337–42.
8 Olsson M, Dalsgaard CJ, Haegerstrand A, et al.
Accumulation of T lymphocytes and expression of inter­leukin-2-receptors in nonrheumatic stenotic aortic valves. J Am Coll Cardiol 1994;23:1162–70.
9 Rajamannan NM, Subramaniam M, Rickard D, et al.
Human aortic valve calcification is associated with an osteoblast phenotype. Circulation 2003;107:2181–4.
10 Cowell SJ, Newby DE, Prescott RJ, et al. Scottish Aortic
Stenosis and Lipid Lowering Trial, Impact on Regression (SALTIRE) Investigators. A randomized trial of intensive lipid- lowering therapy in calcific aortic stenosis. N Engl J Med 2005;352:2389–97.
11 Moura LM, Ramos SF, Zamorano JL, et al. Rosuvastatin
affecting aortic valve endothelium to slow the progres­sion of aortic stenosis. J Am Coll Cardiol 2007; 49:554–61.
12 Turina J, Hess O, Sepulcri F, et al. Spontaneous course of
aortic valve disease. Eur Heart J 1987:8:471–83.
13 Kelly TA, Rothbart RM, Cooper CM, et al. Comparison
of outcome of asymptomatic to symptomatic patients older than 20 years of age with valvular aortic stenosis. Am J Cardiol 1988;61:123–30 .
14 Lindblom D, Lindblom U, Qvist J, et al. Long-term
relative survival rates after heart valve replacement. J Am Coll Cardiol 1990;15:566–73.
15 Bonow RO, Carabello BA, Kanu C, et al. ACC/AHA 2006
guidelines for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (writing committee to revise the 1998 Guidelines for the Management of Patients With Valvular Heart Disease): developed in collaboration with the Society of Cardiovascular Anesthesiologists: endorsed by the Society for Cardiovascular Angiography and Interventions and the Society of Thoracic Surgeons. Circulation 2006;114:e84–231.
16 Rosenhek R, Binder T, Porenta G, et al. Predictors of
outcome in severe asymptomatic aortic stenosis. N Engl J Med 2000;343:611–17.
17 Pai RG, Kapoor N, Bansal RC, et al. Malignant natural
history of asymptomatic severe aortic stenosis: benefit of aortic valve replacement. Ann Thorac Surg 2006;82:2116–22.
18 Chizner MA, Pearle DL, deLeon AC, Jr. The natural
history of aortic stenosis in adults. Am Heart J 1980;99:419–24.
19 Pellikka PA, Sarano ME, Nishimura RA, et al. Outcome
of 622 adults with asymptomatic, hemodynamically significant aortic stenosis during prolonged follow-up. Circulation 2005;111:3290–5
20 Baumgartner H. What influences the outcome of valve
replacement in critical aortic stenosis? Heart 2005;91:1254–6.
21 Chiam PT, Ruiz CE. Percutaneous transcatheter aortic
valve implantation: evolution of the technology. Am Heart J 2009;157:229–42.
22 Walther T, Simon P, Dewey T, et al. Transapical mini-
mally invasive aortic valve implantation: multicenter experience. Circulation 2007;116(11 Suppl):I240–5.
23 Webb JG, Chandavimol M, Thompson CR, et al.
Percutaneous aortic valve implantation retrograde from the femoral artery. Circulation 2006;113:842–50.
24 Leon MB, Smith CR, Mack M, et al. Transcatheter aortic-
valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med 2010; 363:1597–607.
25 Webb JG, Altwegg L, Boone RH, et al. Transcatheter
aortic valve implantation: impact on clinical and valve­related outcomes. Circulation 2009;119:3009–16.
26 Wong DR, Ye J, Cheung A, et al. Technical consider-
ations to avoid pitfalls during transapical aortic valve implantation. J Thorac Cardiovasc Surg 2010;140:196–202.
27 Wendler O, Walther T, Nataf P, et al. Trans-apical aortic
valve implantation: univariate and multivariate analyses of the early results from the SOURCE registry. Eur J Cardiothorac Surg 2010;38:119–27.
28 Walther T, Schuler G, Borger MA, et al. Transapical
aortic valve implantation in 100 consecutive patients: comparisonto propensity-matched conventional aortic valve replacement. Eur Heart J 2010;31:1398–403.
29 Walther T, Dewey T, Wimmer-Greinecker G, et al.
Transapical approach for sutureless stent-fixed aortic valve implantation: experimental results. Eur J Cardiothorac Surg 2006;29:703–8.
30 Webb JG, Altwegg L, Masson JB, et al. A new transcath-
eter aortic valve and percutaneous valve delivery system. J Am Coll Cardiol 2009;53:1855–8.
31 Falk V, Schwammenthal EE, Kempfert J, et al. New ana-
tomically oriented transapical aortic valve implantation. Ann Thorac Surg 2009;87:925–6.
CHAPTER 15 Transapical valve technology for aortic stenosis 185
https://t.me/med1917
32 Falk V, Walther T, Schwammenthal E, et al. Transapical
aortic valve implantation with a self-expanding anatomi­cally oriented valve. Eur Heart J 2011;32(7):878–87.
33 Trahan R. JenaValve Technology initiates multicenter
CE-mark study for its transapical TAVI system. San Francisco: Business Wire, 2010 (updated November 2, 2010, cited January 17, 2011). Available from http://www. businesswire.com/news/home/20101102006317/en/ JenaValve-Technology-Initiates-Multicenter-CE-Mark­Study-Transapical.
34 JenaValve™ Technology. Technology – unique features.
Munich: © JenaValve™ Technology GmbH, 2010, 2011 (cited January 17, 2011). Available from http://www. jenavalve.de/index.php?id=Technology&subid= Unique%20Features&PHPSESSID=97a6c9ab9658d714a a332720cd58deb7.
35 Osswald BR, Gegouskov V, Badowski-Zyla D, et al.
Overestimation of aortic valve replacement risk by EuroSCORE: implications for percutaneous valve replacement. Eur Heart J 2009;30:74–80.
36 Dewey TM, Brown D, Ryan WH, et al. Reliability of risk
algorithms in predicting early and late operative out­comes in high-risk patients undergoing aortic valve replacement. J Thorac Cardiovasc Surg 2008; 135:180–187.
37 Purser JL, Kuchibhatla MN, Fillenbaum GG, et al.
Identifying frailty in hospitalized older adults with significant coronary artery disease. J Am Geriatr Soc 2006;54:1674–81.
38 Jones DM, Song X, Rockwood K. Operationalizing a
frailty index from a standardized comprehensive geri­atric assessment. J Am Geriatr Soc 2004;52:1929–33.
39 National Institute of Health and Clinical Excellence.
Transcatheter aortic valve implantation for aortic stenosis: guidance. London: NICE, June 2008, abstract no. IPG 266.
40 Dewey TM, Brown DL, Das TS, et al. High-risk patients
referred for transcatheter aortic valve implantation: management and outcomes. Ann Thorac Surg 2008;86: 1450–6.
41 Walther T, Dewey T, Borger MA, et al. Transapical aortic
valve implantation: step by step. Ann Thorac Surg 2009;87:276–83.
42 Ruel M, Dickie S, Chow BJ, Labinaz M. Interventional
valve surgery: building a team and working together. Semin Thorac Cardiovasc Surg 2010;22:145–9.
43 Walther T, Falk V, Kempfert J, et al. Transapical mini-
mally invasive aortic valve implantation; the initial 50 patients. Eur J Cardiothorac Surg 2008;33:983–8.
44 Heinze H, Sier H, Schafer U, et al. Percutaneous aortic valve
replacement: overview and suggestions for anesthestic management. J Clin Anesth 2010;22:373–8.
45 Ferrari E, von Segesser LK. Transcatheter aortic valve
implantation (TAVI): state of the art techniques and future perspectives. Swiss Med Wkly 2010;140:w13127.
46 Fan CM, Liu X, Panidis JP, et al. Prediction of homograft
aortic valve size by transthoracic and transesophageal two-dimensional echocardiography. Echocardiography 1997;14:345–8.
47 Moss RR, Ivens E, Pasupati S, et al. Role of echocardiog-
raphy in percutaneous aortic valve implantation. JACC Cardiovasc Imaging 2008;1:15–24.
48 Tops LF, Wood DA, Delgado V, et al. Noninvasive
evaluation of the aortic root with multislice computed tomography implications for transcatheter aortic valve replacement. JACC Cardiovasc Imaging 2008;1:321–30.
49 Schultz CJ, Moelker A, Piazza N, et al. Three dimensional
evaluation of the aortic annulus using multislice com­puter tomography: are manufacturer’s guidelines for sizing for percutaneous aortic valve replacement helpful? Eur Heart J 2010;31:849–56.
50 Messika-Zeitoun D, Serfaty JM, Brochet E, et al.
Multimodal assessment of the aortic annulus diameter. JAm Coll Cardiol 2010;55:186–94.
51 Thomas M, Schymik G, Walther T, et al. Thirty-day
results of the SAPIEN aortic Bioprosthesis European Outcome (SOURCE) Registry: a European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve. Circulation 2010;122:62–9.
52 Eltchaninoff H, Prat A, Gilard M, et al.; on behalf
of the FRANCE Registry Investigators. Eur Heart J 2011;32:191–7.
53 Sinhal A, Altwegg L, Pasupati S, et al. Atrioventricular
block after transcatheter balloon expandable aortic valve implantation. JACC Cardiovasc Interv 2008;1:305–9.
54 Piazza N, Onuma Y, Jesserun E, et al. Early and persis-
tent intraventricular conduction abnormalities and requirements for pacemaking after percutaneous replacement of the aortic valve. JACC Cardiovasc Interv 2008;1:310–16.
55 Murphy CJ, Pasupati S, Webb JG. Hemolysis after trans-
catheter balloon-expandable aortic valve insertion. Can J Cardiol 2007;23:260.
56 Azadani AN, Jaussaud N, Matthews PB, et al. Energy loss
due to paravalvular leak with transcatheter aortic valve implantation. Ann Thorac Surg 2009;88:1857–63.
57 Tuzcu ME. Transcatheter aortic valve replacement mal-
position and embolization: innovation brings solutions also new challenges. Catheter Cardiovasc Interv 2008;71:579–80.
58 Walther T, Falk V, Borger MA, et al. Minimally invasive
transapical beating heart aortic valve implantation – proof of concept. Eur J Cardiothorac Surg 2007;31:9–15.
59 Masson JB, Kovac J, Schuler G, et al. Transcatheter
aortic valve implantation. JACC Cardiovasc Interv 2009;2:811–20.
60 Berry C, Cartier R, Bonan R. Fatal ischemic stroke
related to non permissive peripheral artery access for
186 PART II Structural heart disease
https://t.me/med1917
percutaneous aortic valve replacement. Catheter Cardiovasc Interv 2007;69:56–63.
61 Isner J. Acute catastrophic complications of balloon
aortic valvuloplasty: the Mansfield scientific aortic valvuloplasty registry investigators. J Am Coll Cardiol 1991;17:1436–44.
62 Svensson LG, Dewey T, Kapadia S, et al. United States
feasibility study of transcatheter insertion of a stented aortic valve by the left ventricular apex. Ann Thorac Surg 2008;86:46–54.
63 Cribier A, Eltchaninoff H, Tron C, et al. Treatment of
calcific aortic stenosis with the percutaneous heart valve: mid-term follow-up from the initial feasibility studies: the French experience. J Am Coll Cardiol 2006; 47:1214–23.
64 Grube E, Schuler G, Buellesfeld L, et al. Percutaneous
aortic valve replacement for severe aortic stenosis in high-risk patients using the second- and current third­generation self-expanding CoreValve prosthesis: device success and 30-day clinical outcome. J Am Coll Cardiol 2007;50:69–76.
65 Lu TL, Huber CH, Rizzo E, et al. Ascending aorta mea-
surements as assessed by ECG-gated multi-detector computed tomography: a pilot study to establish norma­tive values for transcatheter therapies. Eur Radiol 2009;19:664–9.
66 Leon MB, Smith CR, Mack M, et al.; PARTNER Trial
Investigators. Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med 2010;363:1597–607.
67 Lefèvre T, Kappetein AP, Wolner E, et al.; on behalf of the
PARTNER EU Investigator Group. One year follow-up of the multi-centre European PARTNER transcatheter heart valve study. Eur Heart J 2011;32:148–57.
68 Leon MB, Piazza N, Nikolsky E, et al. Standardized end-
point definitions for transcatheter aortic valve implanta­tion clinical trials: a consensus report from the Valve Academic Research Consortium. Eur Heart J 2011;32:205–17.
69 Seiffert M, Franzen O, Conradi L, et al. Series of trans-
catheter valve-in-valve implantations in high-risk patients with degenerated bioprostheses in aortic and mitral posi­tion. Catheter Cardiovasc Interv 2010;76:608–15.
70 Webb JG, Wood DA, Ye J, et al. Transcatheter valve-in-
valve implantation for failed bioprosthetic heart valves. Circulation 2010;121:1848–57.
71 Kempfert J, Blumenstein J, Chu MW, et al. Minimally
invasive off-pump valve-in-a-ring implantation: the atrial transcatheter approach for re-operative mitral valve replacement after failed repair. Eur J Cardiothorac Surg 2009;35:965–9.
72 Schmidt D, Dijkman PE, Driessen-Mol A, et al. Minimally
invasive implantation of living tissue engineered heart valves. J Am Coll Cardiol 2010;56:510–20.
Videoclips
This chapter contains the following videoclips:
Video 15.1 Animation Edwards Ascendra 2
system.
Video 15.2 Case presentations: Edwards
Ascendra 2 transapical heart valve (Sapien XT 23 mm).
Video 15.3 Case presentations: Medtronic
Engager transapical heart valve (Engager 26 mm).
Video 15.4 Animation of the transapical
deployment of the JenaValve.
They can be accessed at www.wiley.com/go/ valverepair.
16
https://t.me/med1917
CHAPTER 16
Axillary/subclavian access for transcather aortic valve replacement
Gilles Lemesle1, Arnaud Sudre1 & Thomas Modine
1
Service de Cardiologie B et Centre Hémodynamique, Pôle de Cardiologie, Hôpital Cardiologique,
CHRU de Lille, France
2
Service de Chirurgie Cardio-vasculaire, Pôle de Chirurgie Cardio-vasculaire, Hôpital Cardiologique,
CHRU de Lille, France
Introduction
Patient selection plays a crucial role in the success of transcather aortic valve replacement (TAVR) [1–5]. Vascular access is of major interest and patient selection requires a complete study of the different arterial access points. Today, the trans­femoral route is recommended to be the first vascular access of choice in all TAVR procedures. In some patients, the ilio-femoral artery and/or abdominal aorta anatomy does not allow TAVR through the femoral approach. Small peripheral arteries (diameter less than 6 mm), severe peripheral artery disease, and severe ilio-femoral and/or aorta tortuosities may render the ilio-femo­ral approach difficult or even impossible (Fig.16.1). Indeed, these parameters greatly increase the risk of implantation failure or vascular injury that con­tributes significantly to mortality and morbidity associated with transfemoral TAVR [1–5].
Although there has been a reduction in the sheath size for the different available percutaneous aortic valve implantation (PAVI) devices, they are still relatively big. The Edwards Sapien Retroflex system is a 18 French or 24 Fr delivery catheter
2
system [1–3]. As shown in Fig.16.2, the Medtronic CoreValve revalving system (Minneapolis, MN) is a smaller 18 Fr delivery catheter system [4,5] that subsequently permits the use of the axillary/ subclavian access as a second option when the ilio-femoral access is either impossible or too risky [6–11]. Up to date, little is known about the safety of this approach for PAVI procedures compared with the ilio-femoral access The chapter reviews the technical issues related to this specific access route.
General considerations
Since the first case of TAVR through the axillary/ subclavian access with the Medtronic CoreValve revalving system was published in 2008 [11], the technique has continued to evolve with a rapid degree of adoption [6–10]. Assessing the safety and the fea­sibility of the axillary/subclavian route requires, how­ever, a complete analysis from the skin to the aortic valve. In contrast to the ilio-femoral arteries, axillary and subclavian arteries are usually relatively free of disease even in elderly people and are frequently good-sized vessels. Axillary and subclavian arteries fulfill anatomic criteria in most patients eligible for
Endovascular and Hybrid Therapies for Structural Heart and Aortic Disease, First Edition. Edited by Jacques Kpodonu and Raoul Bonan. © 2013 John Wiley & Sons, Ltd. Published 2013 by John Wiley & Sons, Ltd.
187
188 PART II Structural heart disease
https://t.me/med1917
Fig. 16.1 Examples of ilio-femoral artery and/or abdominal
aorta anatomies that do not allow percutaneous aortic valve implantation. Blue arrows indicate signicant
Over-the-wire (0.035” compatible)
12 F Flexible shaft
atherosclerotic disease reducing the lumen to less than 6 mm in diameter. Green arrows indicate severe tortuosities. Red arrows indicate severe artery aneurysm.
Radiopaque tip
18 F Valve capsule
Radiopaque
marker
Fig. 16.2 Medtronic CoreValve revalving
system, an 18 Fr delivery catheter system.
CHAPTER 16 Axillary/subclavian access for transcather aortic valve replacement 189
https://t.me/med1917
TAVR. Just as a reminder, there are some anatomic criteria that exclude the axillary/subclavian route with regard to the risk of vessel injury.
Contraindications, as for the ilio-femoral route, include:
t
Vessel diameter <6 mm.
t
Severe tortuosity.
t
Severe disease and/or circumferential calcifications.
Patient selection and imaging
Parameters to be assessed for TAVR (such as patient comorbidities, aortic valve anatomy, aortic
(a)
root and ascending aorta anatomy, coronary artery disease, left ventricular function and volume, etc.), have to be analyzed prior to any PAVI procedure through the axillary/subclavian route.
Skin assessment
A simple physical examination is required in order to establish local skin integrity and to eliminate any local infection process and/or skin injury. In addition, operators have to make sure that no obstacle, such as pacemakers, will make it impos­sible for surgical access, hence a careful assessment of the clavicular is needed.
A
C
Fig. 16.3 (a) Examples of assessment of the subclavian
arteries by angiogram: A, aortic arch angiogram allowing a perfect analysis of the origin of the left subclavian artery; B, angiogram of the right subclavian artery; C and D,
B
D
angiogram of the left subclavian artery. (b) Examples of assessment of the subclavian arteries by a CT scanner. (c) Examples of assessment of the subclavian arteries by MRI.
190 PART II Structural heart disease
https://t.me/med1917
(b)
Right subclavian
artery
Right carotid
artery
Right subclavian
artery
Left subclavian
artery
Right carotid
artery
Left carotid
artery
Left carotid
artery
Left subclavian
artery
(c)
Fig. 16.3 (Continued).
Right carotide
artery
Right subclavian
artery
Left carotide
artery
Left subclavian
artery
CHAPTER 16 Axillary/subclavian access for transcather aortic valve replacement 191
https://t.me/med1917
Fig. 16.4 Examples of angle between the aortic valve annulus (red line) and the horizontal line (blue line).
Vessel assessment
Vessel assessment is one of the major points required prior to considering a patient for TAVR. Similar to assessment of the ilio-femoral arteries, angiograms (Fig. 16.3a), computed tomography (CT) scans (Fig.16.3b), and/or magnitude reso­nance imaging (MRI) (Fig.16.3c) provide accurate data on the diameter, tortuosities, and degree of disease and calcifications of the axillary and subclavian arteries. Special care should be taken to look at the origin of the subclavian artery andto any bifurcations, where significant disease and/or calcifications are more frequently found. In addition, the relationship to the verte bral, carotid, and mammary arteries has to be clearly individu-
Fig. 16.5 Left subclavian surgical access (infraclavicular
incision), with an 18 Fr sheath insertion.
alized, especially in patients with patent graft.
Although the left axillary/subclavian artery is the preferred route, the right axillary/subclavian artery is also feasible and safe. The right axillary/ subclavian artery access, however, needs addi-
annulus plan and the horizontal line disqualifies the use of the right axillary/subclavian approach
(Fig.16.4) [7,9]. tional anatomic criteria to be checked. Due to the wire and valve catheter stiffness, the valve catheter tends to be at a vertical angle to the native aortic valve annulus, especially when the right axillary/ subclavian artery is used as access. Other authors have reported that TAVR through the right axillary/subclavian artery is almost impossible when the aortic root becomes more horizontal (i.e. the aortic valve annulus becomes more vertical). An angle greater than 25° between the aortic valve
Surgical access
As direct manual compression is ineffective for
axillary/subclavian arteries in case of closure
failure, percutaneous access is not recommended
and a surgical access is mandatory.
The axillary/subclavian access is very familiar to cardiovascular surgeons. The vessels are usually approached through an infraclavicular incision
192 PART II Structural heart disease
https://t.me/med1917
(Fig.16.5). In patients with an implanted pacemaker in that area, supraclavicular incision could be used, taking into consideration the proximity to the ner vous brachial plexus origin. The infraclavicular incision is well tolerated and causes little discomfort, thus allow­ing very early mobilization. Most of the time, the axillary/subclavian access is done under general anesthesia. Such a vascular access could, however, be done under local anesthesia in an experienced team.
Advantages of the use of the axillary/subclavian access
Most axillary and subclavian arteries are good­sized vessels and are often free of significant disease and calcifications, even in sicker and older people. They subsequently fulfill the implantation criteria in most of the patients.
Secondly, the shorter distance between the arterial access point and the aortic valve compared to the ilio-femoral access usually provides better stability of the delivery catheter. This improves the accuracy of positioning the valve and reduces procedure time (Fig.16.6). An optimal position of the prosthetic valve is of major interest to reduce the risk of valve embolization, para-valvular insuf­ficiency, and coronary artery obstruction.
Thirdly, axillary and/or subclavian artery access and repair are familiar to all cardiovascular sur­geons, with a limited risk of vascular complications and local bleeding.
Limitations of the axillary/ subclavian access
Similar to the ilio-femoral route, vessel diameter <6 mm, severe tortuosity, severe disease, and circumferential calcifications are contraindications. In addition, the presence of a pacemaker may increase the risk of pacemaker damage and/or infec­tion, hence it is recommend that the other subclavian artery be used instead. Finally, the presence of a patent and functional internal mammary artery graft is also reported as a potential contraindication to the use of the axillary/subclavian route because of the risk of graft occlusion or injury.
In the presence of a patent graft, some criteria have to be strictly respected with regard to the risk of axillary and/or subclavian artery dissection or ostial graft occlusion. Should the axillary/ subclavian access be used an artery diameter of >6.5 mm (rather than 6 mm) is needed, there should be an absence of circumferential calcifica­tions or extensive atherosclerotic disease close to the graft origin, and an absence of athero sclerotic lesions requiring peripheral balloon angioplasty.
Conclusions
Among patients eligible for PAVI, some do not meet the criteria for the transfemoral approach. The Medtronic CoreValve revalving system is an 18Fr delivery catheter system that allows axillary/ subclavian access as a second option when ilio­femoral access is either impossible or too risky. The axillary/subclavian approach is indeed feasible and safe for TAVR using the Medtronic CoreValve revalving system allowing especially perfect sta­bility of the device and an easier valve positioning compared to the transfemoral route. It requires, however, an experienced team and a complete check-up from the skin to the aortic valve in order to eliminate all limitations and/or contraindica­tions of the technique.
Fig. 16.6 An 18 Fr sheath in place in the left subclavian
artery, with a short distance between the end of the sheath and the aortic valve annulus allowing a perfect positioning of the valve.
References
1 Cribier A, Eltchaninoff H, Bash A, et al. Percutaneous
transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description. Circulation 2002;106:3006–8.
2 Cribier A, Eltchaninoff H, Tron C, et al. Treatment of
calcific aortic stenosis with the percutaneous heart