In a fired heater, which of the following problems can occur:

A - Overheating, surging, and reflux B - Overheating, tube ruptures, and refractory breakdown C - Overheating, surging, and refractory breakdown D - Overheating, tube ruptures, and reflux Correctness Rule: Single Correct Answer Required Answer(s) Given: B Correct Answer(s): B Marked as: Correct _______________________________________________

Question 5:

The stabilizer overhead condenser:

A - Provides sufficient holding time to settle the flow surges from the inlet separators B - Cools the vapour from the top of the tower C - Prevents hydrates in the tower D - Recovers heat from the overhead product and transfers it to the stabilizer feed Correctness Rule: Single Correct Answer Required Answer(s) Given: B Correct Answer(s): B Marked as: Correct _______________________________________________

Question 6:

The heat exchanger contributes to the economy of the system by:

A - Recovering reflux and transferring it to stabilizer feed B - Removing heat from the overhead product C - Providing air recirculation to avoid freezing of the coil in cold weather D - Recovering heat and transferring it to stabilizer feed Correctness Rule: Single Correct Answer Required Answer(s) Given: D Correct Answer(s): D Marked as: Correct _______________________________________________

Question 7:

Condensed liquid which is pumped back to the top of the stabilizer tower is known as:

A - Carry-over B - Regeneration C - Feed D - Reflux Correctness Rule: Single Correct Answer Required Answer(s) Given: D Correct Answer(s): D Marked as: Correct _______________________________________________

Question 8:

Water has been found in the Stabilizer Reflux Drum. This may be due to:

A - Liquid slug into the Inlet Separator B - Operating the stabilizer reboiler above design temperature C - Malfunctioning Level Controller on the boot of the Stabilizer Feed Drum D - A hydrate in the Overhead vapour line to the L.P. contactor Correctness Rule: Single Correct Answer Required Answer(s) Given: C Correct Answer(s): C Marked as: Correct _______________________________________________

Question 9:

The stabilizer feed drum is designed to provide sufficient holding time to settle the flow surges from the inlet separators and to give adequate:

A - Settling time for the water wash desalting operation B - Surge space for the bottom product pumps C - Space, time, and means for the counter-current contact between the descending vapour and ascending liquids D - Space, time, and means for the counter-current contact between the ascending vapour and descending liquids Correctness Rule: Single Correct Answer Required Answer(s) Given: A Correct Answer(s): A Marked as: Correct _______________________________________________

Question 10:

A condensate stabilizer tower is divided into sections. The top, or "rectifying section", includes:

A - All the trays above the feed tray B - All the trays below the chimney tray C - All the trays above the reflux tray D - All the trays below the feed tray Correctness Rule: Single Correct Answer Required Answer(s) Given: A Correct Answer(s): A Question 1:

A condensate stabilizer tower is divided into sections. The bottom or "stripping section" includes:

A - All the trays above the reflux tray B - All the trays below the chimney tray C - All the trays below the seal pan D - All the trays below the feed tray Correctness Rule: Single Correct Answer Required Answer(s) Given: D Correct Answer(s): D Marked as: Correct _______________________________________________

Question 2:

Reflux is that part of the liquid product from the overhead condenser, which is returned to the top of the stabilizer and controls the:

A - Overhead pressure and purity B - Bottom product temperature and purity C - Surge rate within the condenser D - Overhead temperature and purity Correctness Rule: Single Correct Answer Required Answer(s) Given: D Correct Answer(s): D Marked as: Correct _______________________________________________

Question 3:

The chamber arrangement at the lower section of the stabilizer prevents the:

A - Loss of suction at the reboiler pump B - Liquid surge point from exceeding design maximum C - Formation of hydrates D - Increase of suction at the reboiler pump Correctness Rule: Single Correct Answer Required Answer(s) Given: A Correct Answer(s): A Marked as: Correct _______________________________________________

Question 4:

The purpose of the Stabilizer Feed/Bottoms exchanger is to:

A - Prevent hydrates in the tower B - Recover heat from bottoms products C - Pre-heat raw condensate prior to entering the tower D - Flash water from the raw condensate E - Recover heat from bottoms products & Pre-heat raw condensate prior to entering the tower Correctness Rule: Single Correct Answer Required Answer(s) Given: E Correct Answer(s): E Marked as: Correct _______________________________________________

Question 5:

The liquid separated in the reflux accumulator is:

A - Recovered and used to provide fuel for the fired heater. B - Used to pre-heat raw condensate prior to entering the tower C - Pumped back to the top of the stabilizer tower D - Pumped back to the stabilizer feed drum Correctness Rule: Single Correct Answer Required Answer(s) Given: C Correct Answer(s): C Marked as: Correct _______________________________________________

Question 6:

The purpose of the stabilizer overhead condenser is to remove _______________ from the vapour stream.

A - Acid gases B - C1, C2, C3, and C4 C - Water vapour D - C5, C6, and C7+ Correctness Rule: Single Correct Answer Required Answer(s) Given: D Correct Answer(s): D Marked as: Correct _______________________________________________

Question 7: