- •Pump 6002_Artificial Lift - Gas Lift and Plunger Lift
- •In servicing a plunger lift system, the pig must be periodically removed from the _______________, to inspect the pig seals.
- •If a pumped-off condition causes an underload condition of a submersible pump, the appropriate remedial action is:
- •In the case of a pumped off well utilizing a submersible pump it is necessary to:
- •In a single-acting reciprocating gas compressor, compression takes place:
- •In a double-acting reciprocating gas compressor, compression takes place:
- •In machine shops where pneumatic equipment is used, what is the most commonly used type of air compressor?
- •In a single-acting reciprocating gas compressor, compression takes place:
- •In machine shops where pneumatic equipment is used, what is the most commonly used type of air compressor?
- •In a double-acting reciprocating gas compressor, compression takes place:
- •In machine shops where pneumatic equipment is used, what is the most commonly used type of air compressor?
- •In a double-acting reciprocating gas compressor, compression takes place:
- •In a double-acting reciprocating gas compressor, compression takes place:
- •In a compressor that uses the balanced/opposed cylinder configuration, the cranks are arranged so that:
- •In a double-acting compressor, the purpose of the crosshead is to:
- •In high-pressure ratio and high differential pressure compression applications, which valve type is most commonly used?
- •In a double-acting compressor, the purpose of the crosshead is to:
- •Idling an engine for a few minutes prior to total shutdown avoids:
- •Question 10:
- •In most cases, the choice of the appropriate driver for a gas compressor is ultimately determined by the:
- •Induction motors are simple, rugged and reliable, and have no:
- •Question 10:
- •Induction motors are simple, rugged and reliable, and have no:
- •Question 1:
- •Question 5:
- •In a centrifugal compressor, the diffuser vanes work to:
- •In an axial compressor, a stage consists of a/an:
- •In an axial compressor, the shortest blades on the stator are located:
- •Question 2:
- •In a centrifugal compressor, the diffuser vanes work to:
- •In an axial compressor, the shortest blades on the stator are located:
- •Intercoolers are never equipped with a safety valve, pressure gauges and thermometers on the compressed gas and cooling water piping.
- •In separator vessels, regardless of shape or capacity, the secondary section uses:
- •In separator vessels, regardless of shape or capacity, the secondary section uses:
- •Intercoolers are never equipped with a safety valve, pressure gauges and thermometers on the compressed gas and cooling water piping.
- •Intercooling involves:
- •In separator vessels, regardless of shape or capacity, the secondary section uses:
- •In a vertical separator, where the gas line enters the scrubber, the baffle plate serves to:
- •Question 2:
- •Impressed current systems are commonly used where large currents are required. Direct current is discharged through one or more anodes into the:
- •Impressed current systems are commonly used where large currents are required. Direct current is discharged through one or more anodes into the:
- •Impressed current systems are commonly used where large currents are required. Direct current is discharged through one or more anodes into the:
- •Question 1:
- •Question 6:
- •Question 3:
- •If the level of liquids rises too high in the separator, the operator should check the:
- •In general, which of the following factors should be considered when choosing the size and type of separator:
- •In general, which of the following factors should be considered when choosing the size and type of separator:
- •In general, which of the following factors should be considered when choosing the size and type of separator:
- •If the level of liquids rises too high in the separator, the operator should check the:
- •If the level of liquids rises too high in the separator, the operator should check the:
- •In general, condensate stabilization accomplishes several functions, including:
- •In natural gasoline, the maximum allowable butane content, without a penalty, is usually:
- •In the flash vaporization process, condensate from the hp flash drum is sent to the:
- •In natural gasoline, the maximum allowable butane content, without a penalty, is usually:
- •In the flash vaporization process, vapour from the condensate stripper is sent to the:
- •In general, condensate stabilization accomplishes several functions, including:
- •In the flash vaporization process, condensate from the hp flash drum is sent to the:
- •In the flash vaporization process, vapour from the condensate stripper is sent to the:
- •In natural gasoline, the maximum allowable butane content, without a penalty, is usually:
- •In the flash vaporization process, vapour from the condensate stripper is sent to the:
- •In a fired heater, which of the following problems can occur:
- •In the feed (flash) drum, the water and any glycol carried in from the field is:
- •In the feed (flash) drum, the water and any glycol carried in from the field is:
- •In a fired heater, which of the following problems can occur:
- •Question 10:
- •In the feed (flash) drum, the water and any glycol carried in from the field is:
- •In a fired heater, which of the following problems can occur:
- •In a refluxed stabilizer when the vapour pressure of the natural gasoline gets too high:
- •In a refluxed type of stabilizer, when the vapour pressure of the gasoline becomes too high, it means that the:
- •Question 2:
- •In a refluxed type of stabilizer, when the vapour pressure of the gasoline becomes too high, it means that the:
- •In a refluxed stabilizer when the vapour pressure of the natural gasoline gets too high:
- •In a refluxed stabilizer when the vapour pressure of the natural gasoline gets too high:
- •Question 2:
- •In the regeneration section of a teg plant the solution is heated in a coil immersed in the glycol surge tank and then discharged into the:
- •In the glycol regeneration section of a teg plant, with the stripper:
- •If the inlet gas to a glycol dehydrator contactor is at constant pressure, the higher the temperature is:
- •Question 7:
- •In the glycol dehydration process, identify how the solution flows through the contactor.
- •Question 10:
- •In addition to dehydrating gas dry desiccants can be used to:
- •In a solid desiccant dehydration system that uses two or more towers:
- •In addition to dehydrating gas dry desiccants can be used to:
- •In a solid desiccant dehydration system that uses two or more towers:
- •In a solid desiccant dehydration system that uses two or more towers:
- •In addition to dehydrating gas dry desiccants can be used to:
- •In a solid desiccant dehydration system that uses two or more towers:
- •In addition to dehydrating gas dry desiccants can be used to:
- •If corrosion inhibitors are injected upstream of a molecular sieve system:
- •If corrosion inhibitors are injected upstream of a molecular sieve system:
- •If corrosion inhibitors are injected upstream of a molecular sieve system:
- •In the fractionation tower, the top temperature is set:
- •In a distillation process, the Initial Boiling Point (ibp) is defined as the temperature of the liquid when:
- •In a fractionation tower a 100% pure product can be produced because the vaporization and condensing actions on the trays are 100% effective.
- •In the fractionation tower, the top temperature is set:
- •In the fractionation tower, the top temperature is:
- •In a distillation process, the Initial Boiling Point (ibp) is defined as the temperature of the liquid when:
- •In the fractionation tower, the top temperature is:
- •In the fractionation tower, the top temperature is:
- •In a distillation process, the Initial Boiling Point (ibp) is defined as the temperature of the liquid when:
- •In a distillation process, the Initial Boiling Point (ibp) is defined as the temperature of the liquid when:
- •Question 9:
- •In a fractionating system used in a large sour gas plant, when a mixture of propane and butane is split in the depropanizer, the overhead product is:
- •In a gas plant, when discussing fractionation components, the common abbreviation used for octane is:
- •In a gas plant, when discussing fractionation components, the common abbreviation for ethane is:
- •Question 2:
- •In a gas plant, when discussing fractionation components, the common abbreviation for ethane is:
- •In a gas plant, when discussing fractionation components, the common abbreviation for butane is:
- •In the illustration, which is produced as bottom product from the debutanizer?
- •In a gas plant, when discussing fractionation components, the common abbreviation for ethane is:
- •If you were asked to design a fractionation system for a stream where the mixture consists of c3, c4, and c5, how many towers would your system contain?
- •If a fractionator is used to condense lpg and heavier products, the type of condenser used is a:
- •In a fin fan cooler, air is forced across the tubes by:
- •In a thermal siphon reboiler, the bottom product flows to the bottom of the reboiler by using:
- •If the fractionator bottom temperature is too hot:
- •If a fractionator is used to condense lpg and heavier products, the type of condenser used is a:
- •If you were operating a tower where the bottom temperature is controlled by constant heat input to the reboiler, how would you control the tower temperature?
- •In a fin fan cooler, air is forced across the tubes by:
- •If a fractionator is used to condense lpg and heavier products, the type of condenser used is a:
- •If you were operating a tower where the bottom temperature is controlled by constant heat input to the reboiler, how would you control the tower temperature?
- •If a fractionator is used to condense lpg and heavier products, the type of condenser used is a:
- •If the fractionator bottom temperature is too hot:
- •In a tray-type fractionation tower, flooding takes place when the downcomers cannot:
- •Identify the following type of packing used in the illustration below:
- •In a tray-type fractionation tower, the weirs provide:
- •In a tray-type fractionation tower, if the rising vapour blows the liquid from the tray in a fine spray (leaving the tray essentially dry), the condition is known as:
- •Identify the object in the illustration below:
- •In a tray-type fractionation tower, if the rising vapour blows the liquid from the tray in a fine spray (leaving the tray essentially dry), the condition is known as:
- •In a tray-type fractionation tower, the feed trays are:
- •In a tray-type fractionation tower, if the rising vapour blows the liquid from the tray in a fine spray (leaving the tray essentially dry), the condition is known as:
- •If a fractionator is producing off specification product, all of the following actions can be taken to rectify the problem except:
- •Question 6:
- •Question 3:
- •In a water-cooled overhead condenser, high pressure drop on the water side indicates:
- •In a tower where the purity of the top product is 93% and bottom 97%, both temperatures are high and reducing the heat to the reboiler has not helped, the corrective action to take would be to:
- •Question 2:
- •In a tower where the purity of the top product is 93% and bottom 97%, both temperatures are high and reducing the heat to the reboiler has not helped, the corrective action to take would be to:
- •Question 10:
- •Question 2:
- •In a tower where the purity of the top product is 93% and bottom 97%, both temperatures are high and reducing the heat to the reboiler has not helped, the corrective action to take would be to:
- •Question 10:
- •Question 2:
- •Question 3:
- •In a tower where the purity of the top product is 93% and bottom 97%, both temperatures are high and reducing the heat to the reboiler has not helped, the corrective action to take would be to:
- •Question 10:
- •In an lpg and gasoline loading facility, the pumps are equipped with a flow switch that is usually installed in the pump discharge line and serves to:
- •In a refrigeration chiller:
Intercoolers are never equipped with a safety valve, pressure gauges and thermometers on the compressed gas and cooling water piping.
A - True B - False Correctness Rule: Single Correct Answer Required Answer(s) Given: B Correct Answer(s): B Marked as: Correct _______________________________________________
Question 6:
The major section of the separator vessel labeled "A" in the diagram below is referred to as the:
A - Primary separation section B - Coalescing section C - Secondary or gravity section D - Sump (liquid collection) section Correctness Rule: Single Correct Answer Required Answer(s) Given: A Correct Answer(s): A Marked as: Correct _______________________________________________
Question 7:
The heat exchanger on the discharge of the compressor following the completion of compression is called the:
A - Aftercooler B - Hot mist extractor C - Intercooler D - Vortex breaker Correctness Rule: Single Correct Answer Required Answer(s) Given: A Correct Answer(s): A Marked as: Correct _______________________________________________
Question 8:
Which of the following is not a result of cooling the gas with an intercooler and/or aftercooler:
A - More effective cylinder lubrication B - Reduces weakening of parts due to high temperatures C - Removal of water and oil vapours from the gas stream D - Increased the amount of power required to compress the gas Correctness Rule: Single Correct Answer Required Answer(s) Given: D Correct Answer(s): D Marked as: Correct _______________________________________________
Question 9:
An aftercooler on a reciprocating compressor:
A - Condenses both oil and water from the compressed gas B - Increases the weakening of parts due to high temperatures C - Reduces the level of liquids in the scrubber by operating the dump valve D - Increases the possibility of explosions of oil vapour mixed with air Correctness Rule: Single Correct Answer Required Answer(s) Given: A Correct Answer(s): A Marked as: Correct _______________________________________________
Question 10:
Large, multi-stage gas compressors are usually configured in a back-to-back arrangement because this design:
A - Eliminates the need for intercooling B - Neutralizes the axial thrust forces across the impellers C - Allows for injection cooling D - Provides for higher discharge pressures than other designs Correctness Rule: Single Correct Answer Required Answer(s) Given: B Correct Answer(s): B Marked as: Correct Question 1:
Provided there is no shut-off valve between an aftercooler and an air receiver, a safety valve on the aftercooler is unnecessary.
A - True B - False Correctness Rule: Single Correct Answer Required Answer(s) Given: A Correct Answer(s): A Marked as: Correct _______________________________________________
Question 2:
The major section of the separator vessel labeled "B" in the diagram below is referred to as the:
A - Coalescing section B - Sump (liquid collection) section C - Secondary or gravity section D - Primary separation section Correctness Rule: Single Correct Answer Required Answer(s) Given: C Correct Answer(s): C Marked as: Correct _______________________________________________
Question 3:
The heat exchanger on the discharge of the compressor following the completion of compression is called the:
A - Intercooler B - Aftercooler C - Hot mist extractor D - Vortex breaker Correctness Rule: Single Correct Answer Required Answer(s) Given: A Correct Answer(s): B Marked as: Incorrect _______________________________________________
Question 4:
Which of the following is not a result of cooling the gas with an intercooler and/or aftercooler:
A - Removal of water and oil vapours from the gas stream B - Increased the amount of power required to compress the gas C - More effective cylinder lubrication D - Reduces weakening of parts due to high temperatures Correctness Rule: Single Correct Answer Required Answer(s) Given: B Correct Answer(s): B Marked as: Correct _______________________________________________
Question 5:
The inlet nozzle in the primary section of separator vessels is designed to take advantage of the effects of the:
A - Centrifugal force of the discharge stream B - Centripetal force of the inlet stream C - Gravitational forces within the compartment D - Centrifugal force of the inlet stream Correctness Rule: Single Correct Answer Required Answer(s) Given: D Correct Answer(s): D Marked as: Correct _______________________________________________
Question 6:
The large surface area provided within a horizontal separator allows for:
A - Optimum retention of trapped gas B - Lower equipment cost when compared to vertical separators C - Optimum release of trapped gas D - Ease of liquid level control Correctness Rule: Single Correct Answer Required Answer(s) Given: C Correct Answer(s): C Marked as: Correct _______________________________________________
Question 7:
The vertical separator is chosen for process applications where:
A - The gas/liquid ratio is low or where total gas volumes are high B - The gas/liquid ratio is high or where total gas volumes are low C - Large volumes of total fluids containing large amounts of dissolved gases are present D - The gas/liquid ratio is low or where total gas volumes are low Correctness Rule: Single Correct Answer Required Answer(s) Given: B Correct Answer(s): B Marked as: Correct _______________________________________________
Question 8:
An aftercooler on a reciprocating compressor:
A - Increases the weakening of parts due to high temperatures B - Condenses both oil and water from the compressed gas C - Reduces the level of liquids in the scrubber by operating the dump valve D - Increases the possibility of explosions of oil vapour mixed with air Correctness Rule: Single Correct Answer Required Answer(s) Given: B Correct Answer(s): B Marked as: Correct _______________________________________________
Question 9:
Large, multi-stage gas compressors are usually configured in a _______________ arrangement to aid in balancing residual axial thrust forces.
A - double-flow B - front-to-back C - back-to-back D - side-by-side Correctness Rule: Single Correct Answer Required Answer(s) Given: C Correct Answer(s): C Marked as: Correct _______________________________________________
Question 10:
Because their configuration provides a __________________ the use of horizontal separators allows for optimal release of trapped gas.
A - greater degree of level control B - reduced surface area C - superior control of process temperatures D - greater surface area Correctness Rule: Single Correct Answer Required Answer(s) Given: D Correct Answer(s): D Marked as: Correct Question 1:
Large, multi-stage gas compressors are usually configured in a _______________ arrangement to aid in balancing residual axial thrust forces.
A - double-flow B - front-to-back C - back-to-back D - side-by-side Correctness Rule: Single Correct Answer Required Answer(s) Given: C Correct Answer(s): C Marked as: Correct _______________________________________________
Question 2:
The major section of the separator vessel labeled "C" in the diagram below is referred to as the:
A - Primary separation section B - Coalescing section C - Sump (liquid collection) section D - Secondary or gravity section Correctness Rule: Single Correct Answer Required Answer(s) Given: B Correct Answer(s): B Marked as: Correct _______________________________________________
Question 3:
Gas compressor intercoolers should be equipped with:
A - A safety valve B - A coalescing section C - Mist extractors D - Vents Correctness Rule: Single Correct Answer Required Answer(s) Given: A Correct Answer(s): A Marked as: Correct _______________________________________________
Question 4:
In a vertical separator, where the gas line enters the scrubber, the baffle plate serves to:
A - Increase the velocity of the gas by changing its direction B - Reduce the pressure of the gas when it enters the scrubber C - Protect the side of the scrubber from corrosion D - Direct the gas into a swirling motion causing entrained liquids to drop out Correctness Rule: Single Correct Answer Required Answer(s) Given: D Correct Answer(s): D Marked as: Correct _______________________________________________
Question 5:
Intercooling involves:
A - Cooling the gas before compression B - Cooling the gas by water injection C - Cooling the gas between stages of compression D - Cooling the gas following the completion of compression Correctness Rule: Single Correct Answer Required Answer(s) Given: C Correct Answer(s): C Marked as: Correct _______________________________________________
Question 6:
Side-stream compressors are popular in process gas streams or flows from economizers in refrigeration compression. These compressors are _____________ centrifugal compressors.
A - reciprocating B - single-stage C - two-stage D - four-stage Correctness Rule: Single Correct Answer Required Answer(s) Given: D Correct Answer(s): D Marked as: Correct _______________________________________________
Question 7:
To reduce the gas temperature between states of a gas compressor a/an ___________ is utilized.
A - separator B - aftercooler C - mist extractor D - intercooler Correctness Rule: Single Correct Answer Required Answer(s) Given: D Correct Answer(s): D Marked as: Correct _______________________________________________
Question 8:
The major section of the separator vessel labeled "D" in the diagram below is referred to as the:
A - Sump (liquid collection) section B - Coalescing section C - Secondary or gravity section D - Primary separation section Correctness Rule: Single Correct Answer Required Answer(s) Given: A Correct Answer(s): A Marked as: Correct _______________________________________________
Question 9:
The major section of the separator vessel labeled "A" in the diagram below is referred to as the:
A - Secondary or gravity section B - Coalescing section C - Sump (liquid collection) section D - Primary separation section Correctness Rule: Single Correct Answer Required Answer(s) Given: D Correct Answer(s): D Marked as: Correct _______________________________________________
Question 10:
The vertical separator is chosen for process applications where:
A - The gas/liquid ratio is high or where total gas volumes are low B - Large volumes of total fluids containing large amounts of dissolved gases are present C - The gas/liquid ratio is low or where total gas volumes are low D - The gas/liquid ratio is low or where total gas volumes are high Correctness Rule: Single Correct Answer Required Answer(s) Given: A Correct Answer(s): A Marked as: Correct Question 1:
The inlet nozzle in the primary section of separator vessels is designed to take advantage of the effects of the:
A - Centripetal force of the inlet stream B - Centrifugal force of the discharge stream C - Gravitational forces within the compartment D - Centrifugal force of the inlet stream Correctness Rule: Single Correct Answer Required Answer(s) Given: A Correct Answer(s): D Marked as: Incorrect _______________________________________________
Question 2:
Because their configuration provides a __________________ the use of horizontal separators allows for optimal release of trapped gas.
A - greater surface area B - greater degree of level control C - reduced surface area D - superior control of process temperatures Correctness Rule: Single Correct Answer Required Answer(s) Given: A Correct Answer(s): A Marked as: Correct _______________________________________________
Question 3:
The major section of the separator vessel labeled "D" in the diagram below is referred to as the:
A - Coalescing section B - Secondary or gravity section C - Primary separation section D - Sump (liquid collection) section Correctness Rule: Single Correct Answer Required Answer(s) Given: D Correct Answer(s): D Marked as: Correct _______________________________________________
Question 4:
An aftercooler on a reciprocating compressor:
A - Reduces the level of liquids in the scrubber by operating the dump valve B - Condenses both oil and water from the compressed gas C - Increases the weakening of parts due to high temperatures D - Increases the possibility of explosions of oil vapour mixed with air Correctness Rule: Single Correct Answer Required Answer(s) Given: B Correct Answer(s): B Marked as: Correct _______________________________________________
Question 5:
A header is installed in the gas outlet downstream of a scrubber to:
A - Reduce the velocity of the gas between the scrubber and the compressor B - Keep the pressure entering the compressor as low as possible C - Provide a final collection spot for any liquids carried over from the scrubber D - Allow equal distribution of the gas to more than one compressor Correctness Rule: Single Correct Answer Required Answer(s) Given: D Correct Answer(s): D Marked as: Correct _______________________________________________
Question 6:
In separator vessels, regardless of shape or capacity, the secondary section uses:
A - A pad made up of knitted wire mesh, or a series of cyclonic passages B - The effects of the centrifugal force of the inlet stream to separate liquids from the gas C - A sump to collect all liquids removed from the gas D - The force of gravity to help separate entrained droplets of liquid from the stream Correctness Rule: Single Correct Answer Required Answer(s) Given: D Correct Answer(s): D Marked as: Correct _______________________________________________
Question 7:
Intercoolers are never equipped with a safety valve, pressure gauges and thermometers on the compressed gas and cooling water piping.
A - True B - False Correctness Rule: Single Correct Answer Required Answer(s) Given: B Correct Answer(s): B Marked as: Correct _______________________________________________
Question 8:
Side-stream compressors are popular in process gas streams or flows from economizers in refrigeration compression. These compressors are _____________ centrifugal compressors.
A - two-stage B - four-stage C - reciprocating D - single-stage Correctness Rule: Single Correct Answer Required Answer(s) Given: A Correct Answer(s): B Marked as: Incorrect _______________________________________________
Question 9: