- •Preface
- •0 Introduction
- •1 Scope
- •2 Related Documents
- •3 Definitions
- •4 Policy
- •Section Two. The Purpose and Scope of Def Stan 00-60
- •5 Purpose
- •6 Scope of Def Stan 00-60
- •Section Three. Defence Equipment Acquisition and Materiel Support (DEAMS)
- •7 Business Overview
- •8 Contracting Environment
- •9 Programme and Timing
- •10 Process Integration and Data Management
- •11 Introduction
- •12 ILS Principal Elements
- •13 Additional ILS Elements
- •Section Five. Data Management
- •14 Introduction
- •15 Data Dictionary
- •16 LSAR Relational Tables Business Rules and Reports
- •17 SGML
- •Section 6. Management of Defence Standard 00-60 Maintenance
- •19 Introduction
- •20 Change Procedure
- •21 Defence Standard 00-60 Help Desk
- •Figure 3 Defence Standard 00-60 Change Procedure
- •Figure 6 X Table Relationships
- •Figure 7 A Table Relationships
- •Figure 8 B Table Relationships
- •Figure 9 C Table Relationships
- •Figure 10 E Table Relationships
- •Figure 11 U Table Relationships
- •Figure 12 F Table Relationships
- •Figure 13 G Table Relationships
- •Figure 14 H Table Relationships
- •Figure 15 J Table Relationships
- •Figure 16 Z Table Relationships
- •Figure 17 LSAR Data Tables to Report Matrix
- •Figure 18 LSA-001 summary
- •Figure 19 LSA-003 summary
- •Figure 20 LSA-004 summary
- •Figure 21 LSA-005 summary
- •Figure 22 LSA-006 summary
- •Figure 23 LSA-007 summary
- •Figure 24 LSA-008 summary
- •Figure 25 LSA-009 summary
- •Figure 26 LSA-010 summary
- •Figure 27 LSA-011 summary
- •Figure 28 LSA-012 summary
- •Figure 29 LSA-013 summary
- •Figure 30 LSA-014 summary
- •Figure 31 LSA-016 summary
- •Figure 32 LSA-018 summary
- •Figure 33 LSA-019 summary
- •Figure 34 LSA-023 summary
- •Figure 35 LSA-024 summary
- •Figure 37 LSA-026 summary
- •Figure 38 LSA-027 summary
- •Figure 39 LSA-030 (Option 1) summary
- •Figure 40 LSA-033 summary
- •Figure 41 LSA-036 summary
- •Figure 42 LSA-037 summary
- •Figure 43 LSA-039 summary
- •Figure 44 LSA-040 summary
- •Figure 45 LSA-046 summary
- •Figure 46 LSA-050 summary
- •Figure 47 LSA-056 summary
- •Figure 48 LSA-058 summary
- •Figure 49 LSA-065 summary
- •Figure 50 LSA-070 summary
- •Figure 51 LSA-071 summary
- •Figure 52 LSA-072 summary
- •Figure 53 LSA-074 summary
- •Figure 54 LSA-075 summary
- •Figure 55 LSA-076 summary
- •Figure 56 LSA-077 summary
- •Figure 57 LSA-078 summary
- •Figure 58 LSA-080 summary
- •Figure 59 LSA-085 summary
- •Figure 60 LSA-126 summary
- •Figure 61 LSA-151 summary
- •Figure 62 LSA-152 summary
- •Figure 63 LSA-154 summary
- •Figure 64 LSA-155 summary
- •Figure 65 LSA-602 summary
- •Figure 66 LSA-604 summary
- •Figure 67 LSA-606 summary
- •Figure 68 LSA-608 summary
- •Figure 69 LSA-610 summary
- •Figure 70 LSA-612 summary
- •Figure 71 LSA-614 summary
- •Figure 72 LSA-624 summary
- •Figure 73 LSA-626 summary
- •Figure 74 LSA-628 summary
- •Figure 77 LSA-634 summary
- •Figure 78 LSA-636 summary
- •Figure 79 LSA-648 summary
- •Figure 80 LSA-650 summary
- •Figure 81 LSA-652 summary
- •Figure 82 LSA-654 summary
- •Figure 85 LSA-660 summary
- •Figure 86 LSA-662 summary
- •Figure 87 LSA-664 summary
- •Figure 88 LSA-668 summary
- •Figure 89 LSA-672 summary
- •Figure 90 LSA-674 summary
- •Figure 91 LSA-676 summary
- •Introduction
- •Logistic Support Analysis Record Relational Tables

|
|
|
|
|
|
|
|
Operations and Maintenance |
|
|
|
|
|
|
|
Facility |
|
Task Facility Requirements |
|
Task requirement |
|||
|
|
|
|
Facility Name |
|
|
|
|
End Item Acronym Code |
||
|
|
|
|
Facility Category Code |
|
|
|
|
LSA Control Number |
||
|
|
|
|
Facility Type |
|
|
|
|
Alternate LCN Code |
||
|
|
|
|
|
|
|
|
|
|
|
LCN - Type |
|
|
|
|
|
|
|
|
|
|
|
Task Code |
|
|
|
|
|
|
FA |
|
|
FE |
|
CA |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Facility Narrative |
|
Baseline Facility Narrative |
|
New or Modified Facility Narrative |
|
|
||||
|
Facility Narrative Code |
|
Baseline Facility Narrative Code |
|
New or Modified Facility Narrative |
|
|
||||
|
Facility Narrative Text |
|
Baseline Facility Narrative Text |
|
Code |
|
|
||||
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|||||
|
Sequencing Code |
|
Sequencing Code |
|
New or Modified Facility Narrative |
|
|
||||
|
|
|
|
|
|
|
|
Text Sequencing Code |
|
|
|
|
|
FB |
|
|
|
FC |
|
|
FD |
|
|
Figure 12 F Table Relationships
DEF STAN 00-60 (PART 0)/3
ANNEX C (CONTINUED)
C.10.1 Table FA, Facility. This Table identifies the facility by name, category code and type that the system/equipment under analysis requires. The Table keys are Facility Name (FACNAMFA), Facility Category Code (FACCCDFA), and Facility Type (FACTYPFA). For a given row of information, the following cross-element edits apply to Table FA :
(a)Facility Area (FAAREAFA) and Facility Area UM (FAARUMFA) shall either both be blank, or both have entries.
(b)Facility Construction Unit of Measure Price (FACNCOFA), Facility Construction Unit of Measure (CONUOMFA) and Facility Construction Unit of Measure Price Currency Code (FUMPCCFA) shall all be blank, or all have entries.
CODE |
DATA ELEMENT TITLE/ROLE NAME |
FORMAT |
|
DED |
KEY |
||
FACNAMFA |
FACILITY NAME |
32 |
X |
L |
- |
118 |
K |
FACCCDFA |
FACILITY CATEGORY CODE |
10 |
X |
L |
- |
115 |
K |
FACTYPFA |
FACILITY TYPE |
1 |
A |
F |
- |
483 |
K |
DRCLASFA |
FACILITY DRAWING CLASSIFICATION |
3 |
X |
- |
- |
088 |
|
FADNUMFA |
DRAWING NUMBER |
32 |
X |
L |
- |
089 |
|
FADREVFA |
FACILITY DRAWING REVISION |
2 |
A |
R |
- |
360 |
|
FAAREAFA |
FACILITY AREA |
6 |
N |
R |
- |
112 |
|
FAARUMFA |
FACILITY AREA UNIT OF MEASURE |
2 |
A |
F |
- |
491 |
|
FACNCOFA |
FACILITY CONSTRUCTION UNIT OF MEASURE PRICE |
10 |
N |
R |
2 |
492 |
|
FUMPCCFA |
FACILITY CONSTRUCTION UNIT OF MEASURE PRICE |
3 |
X |
- |
- |
629 |
|
|
CURRENCY CODE |
|
|
|
|
|
|
CONUOMFA |
CONSTRUCTION UNIT OF MEASURE |
2 |
A |
F |
- |
491 |
|
WORKCCFA |
WORK CENTRE CODE |
3 |
X |
L |
- |
711 |
|
C.10.2 Table FB, Facility Narrative. This Table may be used to identify Facility Capability, and Facility Location of either the baseline facility or the new or modified facility. The Table keys consist of Facility Name (FACNAMFA), Facility Category Code (FACCCDFA), Facility Type (FACTYPFA), Facility Narrative Code (FNCODEFB), and Facility Narrative Text Sequencing Code (TEXSEQFB). For a given row of information, the following cross-element edits apply to Table FB :
(a)If the Facility Narrative Code (FNCODEFB) is ‘A’, then this Table identifies the capacity impact on the work load of the facility (Facility Capability, DED 114).
(b)If the Facility Narrative Code (FNCODEFB) is ‘B’, then this Table identifies the existing depot facility in terms of where the facility is located (eg, depot name, building, bay, etc.) (Facility Location, DED 117).
CODE |
DATA ELEMENT TITLE/ROLE NAME |
FORMAT |
|
DED |
KEY |
||
FACNAMFA |
FACILITY NAME |
32 |
X |
L |
- |
118 |
F |
FACCCDFA |
FACILITY CATEGORY CODE |
10 |
X |
L |
- |
115 |
F |
FACTYPFA |
FACILITY TYPE |
1 |
A |
F |
- |
483 |
F |
FNCODEFB |
FACILITY NARRATIVE CODE |
1 |
A |
F |
- |
119 |
K |
TEXSEQFB |
FACILITY NARRATIVE TSC |
5 |
N |
R |
- |
450 |
K |
FACNARFB |
FACILITY NARRATIVE |
65 |
X |
- |
- |
--- |
|
C-76
DEF STAN 00-60 (PART 0)/3
ANNEX C (CONTINUED)
C.10.3 Table FC, Baseline Facility Narrative. This Table may be used to identify Facility Maintenance Requirements, Facility Requirements for Operations, Facility Training Requirement, Facility Requirements Special Considerations, and Facility Requirements Supply and Storage for a baseline facility. Baseline is describing the requirements needed for a facility, this applies to both an existing facility and a new or modified facility. The Table keys consist of Baseline Facility Name (FACNAMFC), Baseline Facility Category Code (FACCCDFC), Baseline Facility Type (FACTYPFC), Baseline Facility Narrative Code (FBNACDFC), and Baseline Facility Narrative Text Sequencing Code (TEXSEQFC). For a given row of information, the following cross-element edits apply to Table FC:
(a)If Baseline Facility Narrative Code (FBNACDFC) is ‘A’, then this Table identifies the maintenance concept for the system/equipment under analysis and the facilities that are required to maintain the system (Facilities Maintenance Requirement, DED 107).
(b)If Baseline Facility Narrative Code (FBNACDFC) is ‘B’, then this Table identifies what facilities are needed to support the system in its daily use (Facilities Requirements For Operations, DED 109).
(c)If Baseline Facility Narrative Code (FBNACDFC) is ‘C’, then this Table identifies what facilities are needed for training (Facilities Requirement for Training, DED 110).
(d)If Baseline Facility Narrative Code (FBNACDFC) is ‘D’, then this Table describes any special considerations which impact facility requirements (Facility Requirements Special Considerations, DED 120).
(e)If Baseline Facility Narrative Code (FBNACDFC) is ‘E’, then this Table describes where the system/equipment will be stored, or if there is an impact in other storage facilities (Facility Requirements Supply/Storage, DED 121).
CODE |
DATA ELEMENT TITLE/ROLE NAME |
FORMAT |
|
DED |
KEY |
||
FACNAMFC |
BASELINE FACILITY NAME |
32 |
X |
L |
- |
118 |
F |
FACCCDFC |
BASELINE FACILITY CATEGORY CODE |
10 |
X |
L |
- |
115 |
F |
FACTYPFC |
BASELINE FACILITY TYPE |
1 |
A |
F |
- |
483 |
F |
FBNACDFC |
FACILITY BASELINE NARRATIVE CODE |
1 |
A |
F |
- |
113 |
K |
TEXSEQFC |
BASELINE FACILITY NARRATIVE TSC |
5 |
N |
R |
- |
450 |
K |
FABNARFC |
BASELINE FACILITY NARRATIVE |
65 |
X |
- |
- |
--- |
|
C.10.4 Table FD, New or Modified Facility Narrative. This Table contains information about modifications of existing facilities or requirements for new facilities. This Table may be used to identify Facility Design Criteria, Facility Installation Lead Time, Facility Task Area Breakdown, Facility Utilization, Facility Requirements, Facility Unit Cost Rationale, Facility Justification, Type of Construction, and Utilities Requirement. The Table keys consist of New or Modified Facility Name (FACNAMFD), New or Modified Facility Category Code (FACCCDFD), New or Modified Facility Type (FACTYPFD) New or Modified Facility Narrative Code (NMFNCDFD), and Text Sequencing Code (TEXSEQFD). For a given row of information, the following cross-element edits apply to Table FD :
C-77
DEF STAN 00-60 (PART 0)/3
ANNEX C (CONTINUED)
(a)If the New or Modified Facility Narrative Code (NMFNCDFD) is ‘A’, then this Table describes the facility design requirements necessary to support the item under analysis (Facility Design Criteria, DED 105).
(b)If the New or Modified Facility Narrative Code (NMFNCDFD) is ‘B’, then this Table describes the facilities installation lead time schedules for contractor produced and installed support, test equipment, and training devices (Facility Installation Lead Time, DED 106).
(c)If the New or Modified Facility Narrative Code (NMFNCDFD) is ‘C’, then this is a narrative description identifying the breakdown of a new or modified facility for the area by individual tasks at the job level to determine maximum use of space (Facility Task Area Breakdown, DED 122).
(d)If the New or Modified Facility Narrative Code (NMFNCDFD) is ‘D’, then this is a Table describing the new or modified facility utilization rate (Facilities Utilization, DED 111).
(e)If the New or Modified Facility Narrative Code (NMFNCDFD) is ‘E’, then this Table describes the location of and the functions to be performed at the new or modified facility (Facilities Requirements, DED 108).
(f)If the New or Modified Facility Narrative Code (NMFNCDFD) is ‘F’, then this is a narrative field identifying variations to the appropriate unit cost contained in the military construction guides (Facility Unit Cost Rationale, DED 123).
(g)If the New or Modified Facility Narrative Code (NMFNCDFD) is ‘G’, then this is a narrative field which identifies the major factors which led to the decision that a new facility was required (Facility Justification, DED 188).
(h)If the New or Modified Facility Narrative Code (NMFNCDFD) is ‘H’, then this Table describes what type of construction is required at a new or modified facility (Type of Construction, DED 482).
(i)If the New or Modified Facility Narrative Code (NMFNCDFD) is ‘I’, then this is a narrative description identifying an estimate of the utilization required for a new or modified facility (Utilities Requirement, DED 502).
CODE |
DATA ELEMENT TITLE/ROLE NAME |
FORMAT |
|
DED |
KEY |
||
FACNAMFD |
NEW OR MODIFIED FACILITY NAME |
32 |
X |
L |
- |
118 |
F |
FACCCDFD |
NEW OR MODIFIED FACILITY CATEGORY CODE |
10 |
X |
L |
- |
115 |
F |
FACTYPFD |
NEW OR MODIFIED FACILITY TYPE |
1 |
A |
F |
- |
483 |
F |
NMFNCDFD |
NEW OR MODIFIED FACILITY NARRATIVE CODE |
1 |
A |
F |
- |
255 |
K |
TEXSEQFD |
NEW OR MODIFIED FACILITY NARRATIVE TSC |
5 |
N |
R |
- |
450 |
K |
NMFNARFD |
NEW OR MODIFIED FACILITY NARRATIVE |
65 |
X |
- |
- |
--- |
|
C.10.5 Table FE, Operations and Maintenance Task Facility Requirement. This Table identifies a need for operations/maintenance facilities for a given task. The Table keys consist of EIAC (EIACODXA), LCN (LSACONXB), ALC (ALTLCNXB), LCN Type
C-78
DEF STAN 00-60 (PART 0)/3
ANNEX C (CONTINUED)
(LCNTYPXB), Task Code (TASKCDCA), Facility Name (FACNAMFA), Facility Category Code (FACCCDFA) and Facility Type (FACTYPFA). For a given row of information, the following cross-element edits apply to Table FE :
(a)If Third Line Capability Forecast Date (TLAFCDFE) or Third Line Capability Development Task Number (TLADTNFE) or Third Line Capability Available (TLAAVAFE) are entered, Task Code (TASKCDCA) third position (O/M level) shall be set to ‘G’.
(b)If Third Line Capability Forecast Date (TLAFCDFE) or Third Line Capability Development Task Number (TLADTNFE) are entered, Third Line Capability Available (TLAAVAFE) shall be ‘N’.
(c)In Table CA, Facility Requirement Code (FTRNRQCA) shall be ‘Y’.
NOTE: If Docking and Essential Defects Intervals (DEDINTFE) is entered, Facility Name (FACNAMFA) and Facility Category Code (FACCCDFA) should be that of a Docking Facility.
CODE |
DATA ELEMENT TITLE/ROLE NAME |
FORMAT |
|
DED |
KEY |
||
EIACODXA |
END ITEM ACRONYM CODE |
10 |
X L |
- |
096 |
F |
|
LSACONXB |
LOGISTIC SUPPORT ANALYSIS CONTROL NUMBER |
18 |
X |
L |
- |
199 |
F |
|
(LCN) |
|
|
|
|
|
|
ALTLCNXB |
ALTERNATE LCN CODE |
2 |
N |
F |
- |
019 |
F |
LCNTYPXB |
LCN TYPE |
1 |
A |
F |
- |
203 |
F |
TASKCDCA |
TASK CODE |
7 |
X |
F |
- |
427 |
F |
FACNAMFA |
FACILITY NAME |
32 |
X |
L |
- |
118 |
F |
FACCCDFA |
FACILITY CATEGORY CODE |
10 |
X |
L |
- |
115 |
F |
FACTYPFA |
FACILITY TYPE |
1 |
A |
F |
- |
483 |
F |
DEDINTFE |
DOCKING AND ESSENTIAL DEFECTS INTERVALS |
3 |
N |
R |
- |
631 |
|
TLAAVAFE |
THIRD LINE CAPABILITY AVAILABLE |
1 |
A |
F |
- |
696 |
|
TLAFCDFE |
THIRD LINE CAPABILITY FORECAST DATE |
8 |
N |
F |
- |
696 |
|
TLADTNFE |
THIRD LINE DEVELOPMENT TASK NO. |
17 |
X |
L |
- |
696 |
|
C-79
DEF STAN 00-60 (PART 0)/3
ANNEX C (CONTINUED)
C.11 Personnel Skill Considerations
Data Tables beginning with ‘G’ in the first position of the Table Code are structured to describe and justify any new or modified personnel skills required to support the system/equipment. Figure 13 depicts the relational hierarchy of these Tables/entities.
TABLE CODE |
TABLE TITLE |
GA |
Skill Speciality |
GB |
New or Modified Skill |
GC |
New or Modified Skill Narrative |
GD |
Skill Aptitude Data (Not used in UK) |
GE |
Physical and Mental Requirements Narrative |
C-80