- •Preface
- •Contributors
- •Contents
- •Introduction
- •Literature Review
- •Major Issues
- •Major Studies
- •Negative Studies
- •References
- •1.1.1 Introduction
- •1.1.3 Torsional Ultrasound
- •1.1.4 Our Procedure for Emulsifying the Nucleus
- •References
- •1.2 Transitioning to Bimanual MICS
- •1.2.1 Introduction
- •1.2.2 Technique
- •1.2.3 Summary
- •1.3 0.7 mm Microincision Cataract Surgery
- •1.3.1 Sub 1 mm MICS: Why?
- •1.3.3 Instrumentation
- •1.3.3.2 0.7 mm Irrigating Instruments
- •1.3.4 Surgery
- •1.3.4.1 Incision
- •1.3.4.2 Capsulorhexis
- •1.3.4.3 Hydrodissection
- •1.3.4.4 Prechopping
- •1.3.5 0.7 mm MICS Combined Procedures
- •1.3.5.1 0.7 mm MICS and Glaucoma Surgery
- •1.3.6 Summary
- •References
- •2. MICS Instrumentation
- •2.1 MICS Instrument Choice: The First Step in the Transition
- •2.2 MICS Incision
- •2.3 MICS Capsulorhexis
- •2.4 MICS Prechopping
- •2.5 MICS Irrigation/Aspiration Instruments
- •2.5.1 19 G Instruments
- •2.5.2 21 G Instruments
- •2.6 MICS Auxiliary Instrument
- •2.6.1 Scissors
- •2.6.2 Gas Forced Infusion
- •2.6.3 Surge Prevention
- •2.7 New MICS Instruments
- •2.7.1 Flat Instruments
- •References
- •3.1 Introduction
- •3.2 Power Generation
- •3.3.1 Tuning
- •3.2.2 Phaco Energy
- •3.2.2.1 Low Frequency Energy
- •3.2.2.2 High Frequency Energy
- •3.2.3 Transient Cavitation
- •3.2.4 Sustained Cavitation
- •3.3.1 Alteration of Stroke Length
- •3.3.2 Alteration of Duration
- •3.3.2.1 Burst Mode
- •3.3.2.2 Pulse Mode
- •Micro Pulse (Hyper-Pulse)
- •Pulse Shaping
- •3.3.3 Alteration of Emission
- •3.4 Fluidics
- •3.5 Vacuum Sources
- •3.6 Surge
- •3.7.1 Micro-incisional Phaco
- •3.7.2 Bimanual Micro-Incisional Phaco
- •3.7.3 Micro-Incisional Coaxial Phaco
- •3.7.3.1 Irrigation and Aspiration
- •3.8 Conclusion
- •Reference
- •Further Reading
- •4.1 Introduction
- •4.3 Incision Size
- •4.4 Torsional Ultrasound
- •4.5 Conclusion
- •References
- •5. Technology Available
- •5.1 How to Better Use Fluidics with MICS
- •5.1.1 Physical Considerations
- •5.1.1.2 Chamber Stability
- •5.1.1.3 Holdability
- •5.1.2 Surgical Considerations
- •5.1.2.2 Phaco Technique
- •5.1.2.4 The OS3 and CataRhex SwissTech Platforms
- •Equipment
- •Machine Settings
- •5.2 How to Use Power Modulation in MICS
- •5.2.1 Introduction
- •5.2.3 The Concept of Unoccluded Flow Vacuum
- •5.2.4 The Intricacies of Ultrasound Power Modulation
- •5.2.5 The Variable Incidence of Wound Burn Rates
- •References
- •5.3 MICS with Different Platforms
- •5.3.1 MICS with the Accurus Surgical System
- •5.3.1.1 Introduction and Historic Background
- •5.3.1.3 Surgical Parameters for MICS with Accurus
- •5.3.1.4 Final Considerations
- •5.3.2.1 Introduction
- •5.3.2.7 Technology for MICS on the AMO Signature
- •5.3.2.8 Applying Signature Technology to CMICS and BMICS
- •5.3.3 MICS with Different Platforms: Stellaris Vision Enhancement System
- •5.3.3.2 Evaluating the Stellaris Vision Enhancement System
- •5.3.3.3 The Advantages of BMICS
- •References
- •6.1 Pupil Dilation and Preoperative Preparation
- •6.1.1 Managing the Small Pupil
- •6.1.2 Techniques that Depend on the Manipulation of the Pupil
- •6.1.3 Iris Surgery
- •6.1.4 Preoperative Preparation and Infection Prophylaxis
- •6.1.5 Evaluating Risk
- •6.1.6 Assessing Your Approach
- •6.1.7 Preventing Infection, Step by Step
- •6.1.8 Sample Protocol Outline
- •6.1.9 A Careful, Critical Eye
- •References
- •6.2 Incisions
- •References
- •6.3 Thermodynamics
- •6.3.1 Introduction
- •6.3.2 Corneal Thermal Damage
- •6.3.3 Heat Generation
- •6.3.4 Factors that Contribute to Thermal Incision Damage
- •6.3.4.1 Energy Emission: Amount and Pattern of How the Energy Is Delivered
- •6.3.4.3 Viscoelastic Devices and Possible Occlusion of the Aspiration Line
- •6.3.4.4 Irrigation Flow
- •6.3.4.5 Position of the Tip Inside the Incision
- •6.3.4.6 Tip Design
- •6.3.4.7 Surgical Technique
- •6.3.5 Conclusion
- •6.4 Using Ophthalmic Viscosurgical Devices with Smaller Incisions
- •6.4.1 Introduction
- •6.4.1.1 The Nature of OVDs: Rheology
- •6.4.1.3 Soft Shell and Ultimate Soft Shell Technique (SST & USST)
- •6.4.2 Routine, Special and complicated Cases
- •6.4.2.1 Phakic and Anterior Chamber IOLs
- •6.4.2.3 Fuchs’ Endothelial Dystrophy
- •6.4.2.5 Capsular Staining for White & Black Cataracts
- •6.4.2.6 Flomax® Intraoperative Floppy Iris Syndrome USST
- •6.4.3 Discussion
- •References
- •6.5 Capsulorhexis
- •References
- •References
- •6.7 Biaxial Microincision Cataract Surgery: Techniques and Sample Surgical Parameters
- •6.8.1 Surgical Technique
- •6.8.2 Advantages
- •6.8.3 Disadvantages
- •6.8.4 Final Thoughts
- •References
- •6.9 BiMICS vs. CoMICS: Our Actual Technique (Bimanual Micro Cataract Surgery vs. Coaxial Micro Cataract Surgery)
- •6.9.1 Introduction
- •6.9.2 Historical Background
- •6.9.3 BiMICS. BiManual MicroIncision Cataract Surgery
- •6.9.3.1 Introduction
- •6.9.3.2 Instrumentation
- •6.9.3.5 Phacotips
- •6.9.3.6 Capsulorhexis
- •6.9.3.7 Phaco Knives
- •6.9.3.8 The Phaco Machines
- •6.9.3.9 Phaco Pumps
- •6.9.3.10 Ultrasound Power Delivery
- •6.9.3.11 IOL Implantation
- •6.9.3.12 Astigmatism
- •6.9.4.1 Capsulorhexis
- •6.9.4.2 Phacotips
- •6.9.4.3 The Phaco Machines
- •6.9.4.4 Phaco Pumps
- •6.9.4.5 Ultrasound Power Delivery
- •6.9.4.6 Irrigation-Aspiration
- •6.9.4.7 Incision-Assisted IOL Implantation
- •6.9.5 Conclusion
- •References
- •6.10 Endophthalmitis Prevention
- •6.10.1 Antibiotic Prophylaxis
- •6.10.2 Wound Construction
- •6.10.3 Summary
- •References
- •7.1 High Myopia
- •7.2 Posterior Polar Cataract
- •7.3 Posterior Subluxed Cataracts
- •7.4 Mature Cataract with Zonular Dialysis
- •7.5 Punctured Posterior Capsule
- •7.6 Posterior Capsule Rupture
- •7.7 Pseudoexfoliation
- •7.8 Rock-Hard Nuclei
- •7.9 Switching Hands
- •7.10 Microcornea or Microphthalmos
- •7.11 Large Iridodialysis and Zonular Defects
- •7.12 Intraoperative Floppy Iris Syndrome (IFIS)
- •7.14 Iris Bombé
- •7.15 Very Shallow Anterior Chambers
- •7.16 Refractive Lens Exchange
- •7.18 Intraocular Cautery
- •7.19 Biaxial Microincision Instruments
- •References
- •7.1 MICS in Special Cases: Incomplete Capsulorhexis
- •7.1.1 Introduction
- •7.1.2 Avoiding Complications While Constructing Your Microcapsulorhexis
- •7.1.3 Avoiding Complications During Biaxial Phaco with an Incomplete Capsulorhexis
- •7.1.4 Avoiding Complications During IOL Insertion with an Incomplete Capsulorhexis
- •7.1.5 Conclusions
- •References
- •7.2 MICS in Special Cases (on CD): Vitreous Loss
- •7.2.1 Introduction
- •7.2.2 Posterior Capsule Tears and Vitreous Prolapse
- •7.2.3 Vitreous and the Epinucleus or Cortex
- •7.2.4 Different Techniques Other than Pars Plana Vitrectomy for Nuclear Loss in Vitreous
- •7.2.5 Pars Plana Vitrectomy
- •7.2.6 Zonulolysis
- •References
- •7.3 How to Deal with Very Hard and Intumescent Cataracts
- •7.3.1 Introduction
- •7.3.2 Types of Cataracts
- •7.3.3 Management of Hard Cataracts Through Biaxial Technique
- •7.3.4 Incision
- •7.3.5 Capsulorrhexis
- •7.3.6 Hydrodissection
- •7.3.8 Conclusion
- •References
- •8. IOL Types and Implantation Techniques
- •8.1 MICS Intraocular Lenses
- •8.1.1 Introduction
- •8.1.2 Lenses
- •8.1.2.2 ThinOptX MICS IOLs (ThinOptX, Abingdon, VA)
- •8.1.2.3 Akreos MI60 AO Micro Incision IOL (Bausch & Lomb, Rochester, NY)
- •8.1.2.4 IOLtech MICS lens (IOLtech, La Rochelle, France; and Carl Zeiss Meditec, Stuttgard, Germany)
- •8.1.3 Optical Quality of MICS IOLs
- •8.1.4 Conclusion
- •References
- •8.2 Implantation Techniques
- •8.2.2 Prerequisites to a Sub-2 Injection
- •8.2.3 IOLs Used for Injection Through Microincision
- •8.2.3.1 Material
- •8.2.3.2 Design
- •8.2.3.3 Optic Design
- •8.2.3.4 Haptic Design
- •8.2.3.5 Posterior Barrier (360°)
- •8.2.4 Injectors Meant for Microincision
- •8.2.4.1 Objectives of Injectors Meant for Microincision
- •8.2.4.2 Characteristics of Sub-2 Injectors
- •8.2.4.3 The Cartridges
- •Loading Chambers
- •Injection Tunnels and Cartridge Tips
- •8.2.4.4 The Plunger Tips (or plunger)
- •8.2.4.5 Pushing Systems
- •8.2.4.6 Injector Bodies
- •8.2.4.7 Principal Sub-2 Injectors
- •8.2.5 Visco Elastic Substances and Injection Through Microincision
- •8.2.6 Techniques of Sub-2 Injection
- •8.2.6.2 Incision Construction
- •8.2.6.3 Pressurization of the Anterior Chamber
- •8.2.6.4 Loading the Cartridge
- •8.2.6.5 Loading the Injector
- •8.2.6.6 Insertion of the Plunger Tip
- •8.2.6.7 Injection in the Anterior Chamber
- •8.2.6.8 Positioning the IOL in the Capsular Bag
- •8.2.6.9 Removing the VES
- •8.2.6.10 Thin Roller Injector
- •8.2.6.11 Conclusion
- •Reference
- •8.3 Special Lenses
- •8.3.1 Toric Posterior Chamber Intraocular Lenses in Cataract Surgery and Refractive Lens Exchange
- •8.3.1.1 Introduction
- •8.3.1.3 T-IOL Calculation
- •8.3.1.4 Current T-IOL Models
- •8.3.1.5 Preoperative Marking
- •8.3.1.6 Clinical Indications
- •8.3.1.7 Custom-Made Lenses
- •8.3.1.8 Conclusion for Practice
- •References
- •8.3.2 Special Lenses: MF
- •8.3.2.1 Discussion
- •8.3.2.2 Conclusion
- •8.3.2.3 Outlook
- •References
- •8.3.3 Special Lenses: Aspheric
- •References
- •8.3.4 Intraocular Lenses to Restore and Preserve Vision Following Cataract Surgery
- •8.3.4.1 Introduction
- •8.3.4.2 Why Filter Blue Light?
- •Summary
- •8.3.4.3 Importance of Blue Light to Cataract and Refractive Lens Exchange Patients
- •Summary
- •8.3.4.4 Quality of Vision with Blue Light Filtering IOLs
- •Summary
- •8.3.4.5 Clinical Experience
- •Summary
- •8.3.4.6 Unresolved Issues and Future Considerations
- •References
- •8.3.5 Microincision Intraocular Lenses: Others
- •8.3.5.1 ThinOptX®
- •8.3.5.2 Smart IOL
- •8.3.5.4 AcriTec
- •8.3.5.5 Akreos
- •8.3.5.7 Rayner
- •8.3.5.8 Injectable Polymers
- •8.3.5.9 Final Comments
- •References
- •9. Outcomes
- •9.1 Safety: MICS versus Coaxial Phaco
- •9.1.1 Introduction
- •9.1.2 Visual Outcomes
- •9.1.3 Incision Damage
- •9.1.4 Corneal Incision Burn
- •9.1.5 Corneal Changes
- •9.1.6 Infection
- •9.1.7 Summary
- •References
- •9.2 Control of Corneal Astigmatism and Aberrations
- •9.2.1 Introduction: Impacts of MICS Incision on the Outcomes of Cataract Surgery
- •9.2.2 Objective Evaluation of Corneal Incision
- •9.2.3 Control of Corneal Aberration and Astigmatism with MICS
- •9.2.4 Role of Corneal Aberrometry in Evaluating MICS Incision
- •9.2.5 Role of OCT in Evaluating MICS Incision
- •9.2.6 Our Experience in Corneal Aberrations and Astigmatism After MICS
- •9.2.7 Conclusion
- •References
- •9.3 Corneal Endothelium and Other Safety Issues
- •9.4 Incision Quality in MICS
- •9.4.1 Introduction: History of Incision Size Reduction
- •9.4.2 The Trends Towards Microincision Cataract Surgery (BMICS)
- •9.4.3 Advantages of Minimizing the Incision Size
- •9.4.4 Model for the Analysis of Corneal Incision Quality [21]
- •9.4.5 Our Protocol for Evaluation of Incision Quality in BMICS [21]
- •9.4.6 Results
- •9.4.6.1 Visual, Refractive and Biomicroscopic Outcomes
- •9.4.6.2 Incision Imaging (OCT) Outcomes
- •9.4.8 Conclusion
- •References
- •INDEX
8.3 Special Lenses |
243 |
Take Home Pearls
ßToric IOLs provide a much more reliable and a precise way to correct astigmatism in
pseudophakia.
ßSurgeons should use surgical techniques that control the induction of change in astigmatism
in order to make an adequate use of toric IOLs in the surgery.
ßIn the future, due to their unlimited range, toric IOLs are to be dominant in the correction of astig-
matism above 2 diopters. Toric IOL calculation is based on preoperative corneal astigmatism.
ßAxis detection, prior to surgery is mandatory before starting the surgery. Preoperative mark-
ing of the adequate axis should be performed just before preparing the patient for surgery.
References
1.Amm M, Halberstadt M. [Implantation of toric intraocular lenses for correction of high post-keratoplasty astigmatism]. Ophthalmologe 2002; 99(6):464–469
2.Auffarth GU. (Hrsg.) Aktuelle Laseranwendungen in der refraktiven Chirurgie. Uni-Med Verlag, Bremen, 2004, ISBN 3-89599-806-0
3.Auffarth GU, Holzer MP, Becker KA, Völcker HE. Erste Erfahrungen mit der torischen Silikonintraokularlinse MS6116TU mit Z-Haptik. In: Auffarth GU, Welt R, Demeler U (eds) Kongressband: 17. Kongress der Deutschsprachigen Gesellschaft für Intraokularlinsen Implantation und Refraktive Chirurgie. Biermann, Köln, 2003, pp 171–174
4.Becker KA, Auffarth GU, Volcker HE. Messmethode zur Bestimmung der Rotation und der Dezentrierung von Intraokularlinsen. Ophthalmologe 2004; 101(6):600–603
5.Becker KA, Martin M, Rabsilber TM, Entz BB, Reuland AJ, Auffarth GU. Prospective, non-randomised, long-term clinical evaluation of a foldable hydrophilic single-piece intraocular lens: results of the Centerflex FDA study. Br J Ophthalmol 2006; 90(8):971–974
6.Chang DF. Early rotational stability of the longer Staar toric intraocular lens: fifty consecutive cases. J Cataract Refract Surg 2003; 29(5):935–940
7.De Silva DJ, Ramkissoon YD, Bloom PA. Evaluation of a toric intraocular lens with a Z-haptic. J Cataract Refract Surg 2006; 32(9):1492–1498
8.Dick HB, Krummenauer F, Trober L. [Compensation of corneal astigmatism with toric intraocular lens: results of a multicentre study]. Klin Monatsbl Augenheilkd 2006; 223(7):593–608
9.Gerten G, Michels A, Olmes A. Toric intraocular lenses. Clinical results and rotational stability] Ophthalmologe. 2001; 98(8):715–720
10.Gills J, Van der Karr M, Cherchio M. Combined toric intraocular lens implantation and relaxing incisions to reduce high preexisting astigmatism. J Cataract Refract Surg 2002; 28(9):1585–1588
11.Holzer MP, Auffarth GU, Reuland A.J., Entz BB, Becker KA. Clear Lens Extraction mit Implantation torischer Intraokularlinsen (MS6116 Microsil) als refraktiver Eingriff. In: Pham DT, Auffarth GU, Wirbelauer C, Demeler U (Hrsg.) Kongressband: 18. Kongress der Deutschsprachigen Gesellschaft für Intraokularlinsen Implantation und Refraktive Chirurgie, Biermann, Köln, 2004, pp 377–380
12.Horn JD. Status of toric intraocular lenses. Curr Opin Ophthalmol 2007; 18(1):58–61
13.Langenbucher A, Szentmary N, Seitz B. Calculating the power of toric phakic intraocular lenses. Ophthalmic Physiol Opt 2007; 27(4):373–380
14.Langenbucher A, Viestenz A, Seitz B, Brunner H. Computerized calculation scheme for retinal image size after implantation oftoric intraocular lenses. Acta Ophthalmol Scand 2007; 85(1):92–98
15.Mohammadpour M. Toric IOL and postkeratoplasty astigmatism. Ophthalmology 2007; 114(4):825–826; author reply 826–827
16.Nishi Y, Rabsilber TM, Limberger IJ, Vucic D, Auffarth GU. Influence of 360 degree enhanced optic edge design on secondary cataract development of a hydrophilic acrylic IOL. J Cataract Refract Surg 2007; 33(2):227–231
17.Rabsilber TM, Auffarth GU, Vargas LG, Reuland AJ, Entz BB. Erste Erfahrungen mit der Rayner 570T torischen Intraokularlinse. In: Pham DT, Auffarth GU, Wirbelauer C, Demeler U (Hrsg.) Kongressband: 18. Kongress der Deutschsprachigen Gesellschaft für Intraokularlinsen Implantation und Refraktive Chirurgie, Biermann, Köln, 2004, pp 373–376
18.Ruhswurm I, Scholz U, Zehetmayer M, Hanselmayer G, Vass C, Skorpik C. Astigmatism correction with a foldable toric intraocular lens in cataract patients. J Cataract Refract Surg 2000; 26(7):1022–1027
19.Sun XY, Vicary D, Montgomery P, Griffiths M. Toric intraocular lenses for correcting astigmatism in 130 eyes. Ophthalmology 2000; 107(9):1776–1781
20.Tahzib NG, Eggink FA, Odenthal MT, Nuijts RM. Artisan iris-fixated toric phakic and aphakic intraocular lens implantation for the correction of astigmatic refractive error after radial keratotomy. J Cataract Refract Surg 2007; 33(3):531–535
21.Tehrani M, Dick HB. [Implantation of an ARTISAN toric phakic intraocular lens to correct high astigmatism after penetrating keratoplasty]. Klin Monatsbl Augenheilkd 2002; 219(3):159–163
22.Tehrani M, Schwenn O, Dick HB. [Toric intraocular lens to correct high astigmatism after penetrating keratoplasty in a pseudophakic eye – a case report]. Klin Monatsbl Augenheilkd 2001; 218(12):795–799
23.Till JS, Yoder PR Jr, Wilcox TK, Spielman JL. Toric intraocular lens implantation: 100 consecutive cases. J Cataract Refract Surg 2002; 28(2):295–301
