- •Preface
- •Contributors
- •Contents
- •Introduction
- •Literature Review
- •Major Issues
- •Major Studies
- •Negative Studies
- •References
- •1.1.1 Introduction
- •1.1.3 Torsional Ultrasound
- •1.1.4 Our Procedure for Emulsifying the Nucleus
- •References
- •1.2 Transitioning to Bimanual MICS
- •1.2.1 Introduction
- •1.2.2 Technique
- •1.2.3 Summary
- •1.3 0.7 mm Microincision Cataract Surgery
- •1.3.1 Sub 1 mm MICS: Why?
- •1.3.3 Instrumentation
- •1.3.3.2 0.7 mm Irrigating Instruments
- •1.3.4 Surgery
- •1.3.4.1 Incision
- •1.3.4.2 Capsulorhexis
- •1.3.4.3 Hydrodissection
- •1.3.4.4 Prechopping
- •1.3.5 0.7 mm MICS Combined Procedures
- •1.3.5.1 0.7 mm MICS and Glaucoma Surgery
- •1.3.6 Summary
- •References
- •2. MICS Instrumentation
- •2.1 MICS Instrument Choice: The First Step in the Transition
- •2.2 MICS Incision
- •2.3 MICS Capsulorhexis
- •2.4 MICS Prechopping
- •2.5 MICS Irrigation/Aspiration Instruments
- •2.5.1 19 G Instruments
- •2.5.2 21 G Instruments
- •2.6 MICS Auxiliary Instrument
- •2.6.1 Scissors
- •2.6.2 Gas Forced Infusion
- •2.6.3 Surge Prevention
- •2.7 New MICS Instruments
- •2.7.1 Flat Instruments
- •References
- •3.1 Introduction
- •3.2 Power Generation
- •3.3.1 Tuning
- •3.2.2 Phaco Energy
- •3.2.2.1 Low Frequency Energy
- •3.2.2.2 High Frequency Energy
- •3.2.3 Transient Cavitation
- •3.2.4 Sustained Cavitation
- •3.3.1 Alteration of Stroke Length
- •3.3.2 Alteration of Duration
- •3.3.2.1 Burst Mode
- •3.3.2.2 Pulse Mode
- •Micro Pulse (Hyper-Pulse)
- •Pulse Shaping
- •3.3.3 Alteration of Emission
- •3.4 Fluidics
- •3.5 Vacuum Sources
- •3.6 Surge
- •3.7.1 Micro-incisional Phaco
- •3.7.2 Bimanual Micro-Incisional Phaco
- •3.7.3 Micro-Incisional Coaxial Phaco
- •3.7.3.1 Irrigation and Aspiration
- •3.8 Conclusion
- •Reference
- •Further Reading
- •4.1 Introduction
- •4.3 Incision Size
- •4.4 Torsional Ultrasound
- •4.5 Conclusion
- •References
- •5. Technology Available
- •5.1 How to Better Use Fluidics with MICS
- •5.1.1 Physical Considerations
- •5.1.1.2 Chamber Stability
- •5.1.1.3 Holdability
- •5.1.2 Surgical Considerations
- •5.1.2.2 Phaco Technique
- •5.1.2.4 The OS3 and CataRhex SwissTech Platforms
- •Equipment
- •Machine Settings
- •5.2 How to Use Power Modulation in MICS
- •5.2.1 Introduction
- •5.2.3 The Concept of Unoccluded Flow Vacuum
- •5.2.4 The Intricacies of Ultrasound Power Modulation
- •5.2.5 The Variable Incidence of Wound Burn Rates
- •References
- •5.3 MICS with Different Platforms
- •5.3.1 MICS with the Accurus Surgical System
- •5.3.1.1 Introduction and Historic Background
- •5.3.1.3 Surgical Parameters for MICS with Accurus
- •5.3.1.4 Final Considerations
- •5.3.2.1 Introduction
- •5.3.2.7 Technology for MICS on the AMO Signature
- •5.3.2.8 Applying Signature Technology to CMICS and BMICS
- •5.3.3 MICS with Different Platforms: Stellaris Vision Enhancement System
- •5.3.3.2 Evaluating the Stellaris Vision Enhancement System
- •5.3.3.3 The Advantages of BMICS
- •References
- •6.1 Pupil Dilation and Preoperative Preparation
- •6.1.1 Managing the Small Pupil
- •6.1.2 Techniques that Depend on the Manipulation of the Pupil
- •6.1.3 Iris Surgery
- •6.1.4 Preoperative Preparation and Infection Prophylaxis
- •6.1.5 Evaluating Risk
- •6.1.6 Assessing Your Approach
- •6.1.7 Preventing Infection, Step by Step
- •6.1.8 Sample Protocol Outline
- •6.1.9 A Careful, Critical Eye
- •References
- •6.2 Incisions
- •References
- •6.3 Thermodynamics
- •6.3.1 Introduction
- •6.3.2 Corneal Thermal Damage
- •6.3.3 Heat Generation
- •6.3.4 Factors that Contribute to Thermal Incision Damage
- •6.3.4.1 Energy Emission: Amount and Pattern of How the Energy Is Delivered
- •6.3.4.3 Viscoelastic Devices and Possible Occlusion of the Aspiration Line
- •6.3.4.4 Irrigation Flow
- •6.3.4.5 Position of the Tip Inside the Incision
- •6.3.4.6 Tip Design
- •6.3.4.7 Surgical Technique
- •6.3.5 Conclusion
- •6.4 Using Ophthalmic Viscosurgical Devices with Smaller Incisions
- •6.4.1 Introduction
- •6.4.1.1 The Nature of OVDs: Rheology
- •6.4.1.3 Soft Shell and Ultimate Soft Shell Technique (SST & USST)
- •6.4.2 Routine, Special and complicated Cases
- •6.4.2.1 Phakic and Anterior Chamber IOLs
- •6.4.2.3 Fuchs’ Endothelial Dystrophy
- •6.4.2.5 Capsular Staining for White & Black Cataracts
- •6.4.2.6 Flomax® Intraoperative Floppy Iris Syndrome USST
- •6.4.3 Discussion
- •References
- •6.5 Capsulorhexis
- •References
- •References
- •6.7 Biaxial Microincision Cataract Surgery: Techniques and Sample Surgical Parameters
- •6.8.1 Surgical Technique
- •6.8.2 Advantages
- •6.8.3 Disadvantages
- •6.8.4 Final Thoughts
- •References
- •6.9 BiMICS vs. CoMICS: Our Actual Technique (Bimanual Micro Cataract Surgery vs. Coaxial Micro Cataract Surgery)
- •6.9.1 Introduction
- •6.9.2 Historical Background
- •6.9.3 BiMICS. BiManual MicroIncision Cataract Surgery
- •6.9.3.1 Introduction
- •6.9.3.2 Instrumentation
- •6.9.3.5 Phacotips
- •6.9.3.6 Capsulorhexis
- •6.9.3.7 Phaco Knives
- •6.9.3.8 The Phaco Machines
- •6.9.3.9 Phaco Pumps
- •6.9.3.10 Ultrasound Power Delivery
- •6.9.3.11 IOL Implantation
- •6.9.3.12 Astigmatism
- •6.9.4.1 Capsulorhexis
- •6.9.4.2 Phacotips
- •6.9.4.3 The Phaco Machines
- •6.9.4.4 Phaco Pumps
- •6.9.4.5 Ultrasound Power Delivery
- •6.9.4.6 Irrigation-Aspiration
- •6.9.4.7 Incision-Assisted IOL Implantation
- •6.9.5 Conclusion
- •References
- •6.10 Endophthalmitis Prevention
- •6.10.1 Antibiotic Prophylaxis
- •6.10.2 Wound Construction
- •6.10.3 Summary
- •References
- •7.1 High Myopia
- •7.2 Posterior Polar Cataract
- •7.3 Posterior Subluxed Cataracts
- •7.4 Mature Cataract with Zonular Dialysis
- •7.5 Punctured Posterior Capsule
- •7.6 Posterior Capsule Rupture
- •7.7 Pseudoexfoliation
- •7.8 Rock-Hard Nuclei
- •7.9 Switching Hands
- •7.10 Microcornea or Microphthalmos
- •7.11 Large Iridodialysis and Zonular Defects
- •7.12 Intraoperative Floppy Iris Syndrome (IFIS)
- •7.14 Iris Bombé
- •7.15 Very Shallow Anterior Chambers
- •7.16 Refractive Lens Exchange
- •7.18 Intraocular Cautery
- •7.19 Biaxial Microincision Instruments
- •References
- •7.1 MICS in Special Cases: Incomplete Capsulorhexis
- •7.1.1 Introduction
- •7.1.2 Avoiding Complications While Constructing Your Microcapsulorhexis
- •7.1.3 Avoiding Complications During Biaxial Phaco with an Incomplete Capsulorhexis
- •7.1.4 Avoiding Complications During IOL Insertion with an Incomplete Capsulorhexis
- •7.1.5 Conclusions
- •References
- •7.2 MICS in Special Cases (on CD): Vitreous Loss
- •7.2.1 Introduction
- •7.2.2 Posterior Capsule Tears and Vitreous Prolapse
- •7.2.3 Vitreous and the Epinucleus or Cortex
- •7.2.4 Different Techniques Other than Pars Plana Vitrectomy for Nuclear Loss in Vitreous
- •7.2.5 Pars Plana Vitrectomy
- •7.2.6 Zonulolysis
- •References
- •7.3 How to Deal with Very Hard and Intumescent Cataracts
- •7.3.1 Introduction
- •7.3.2 Types of Cataracts
- •7.3.3 Management of Hard Cataracts Through Biaxial Technique
- •7.3.4 Incision
- •7.3.5 Capsulorrhexis
- •7.3.6 Hydrodissection
- •7.3.8 Conclusion
- •References
- •8. IOL Types and Implantation Techniques
- •8.1 MICS Intraocular Lenses
- •8.1.1 Introduction
- •8.1.2 Lenses
- •8.1.2.2 ThinOptX MICS IOLs (ThinOptX, Abingdon, VA)
- •8.1.2.3 Akreos MI60 AO Micro Incision IOL (Bausch & Lomb, Rochester, NY)
- •8.1.2.4 IOLtech MICS lens (IOLtech, La Rochelle, France; and Carl Zeiss Meditec, Stuttgard, Germany)
- •8.1.3 Optical Quality of MICS IOLs
- •8.1.4 Conclusion
- •References
- •8.2 Implantation Techniques
- •8.2.2 Prerequisites to a Sub-2 Injection
- •8.2.3 IOLs Used for Injection Through Microincision
- •8.2.3.1 Material
- •8.2.3.2 Design
- •8.2.3.3 Optic Design
- •8.2.3.4 Haptic Design
- •8.2.3.5 Posterior Barrier (360°)
- •8.2.4 Injectors Meant for Microincision
- •8.2.4.1 Objectives of Injectors Meant for Microincision
- •8.2.4.2 Characteristics of Sub-2 Injectors
- •8.2.4.3 The Cartridges
- •Loading Chambers
- •Injection Tunnels and Cartridge Tips
- •8.2.4.4 The Plunger Tips (or plunger)
- •8.2.4.5 Pushing Systems
- •8.2.4.6 Injector Bodies
- •8.2.4.7 Principal Sub-2 Injectors
- •8.2.5 Visco Elastic Substances and Injection Through Microincision
- •8.2.6 Techniques of Sub-2 Injection
- •8.2.6.2 Incision Construction
- •8.2.6.3 Pressurization of the Anterior Chamber
- •8.2.6.4 Loading the Cartridge
- •8.2.6.5 Loading the Injector
- •8.2.6.6 Insertion of the Plunger Tip
- •8.2.6.7 Injection in the Anterior Chamber
- •8.2.6.8 Positioning the IOL in the Capsular Bag
- •8.2.6.9 Removing the VES
- •8.2.6.10 Thin Roller Injector
- •8.2.6.11 Conclusion
- •Reference
- •8.3 Special Lenses
- •8.3.1 Toric Posterior Chamber Intraocular Lenses in Cataract Surgery and Refractive Lens Exchange
- •8.3.1.1 Introduction
- •8.3.1.3 T-IOL Calculation
- •8.3.1.4 Current T-IOL Models
- •8.3.1.5 Preoperative Marking
- •8.3.1.6 Clinical Indications
- •8.3.1.7 Custom-Made Lenses
- •8.3.1.8 Conclusion for Practice
- •References
- •8.3.2 Special Lenses: MF
- •8.3.2.1 Discussion
- •8.3.2.2 Conclusion
- •8.3.2.3 Outlook
- •References
- •8.3.3 Special Lenses: Aspheric
- •References
- •8.3.4 Intraocular Lenses to Restore and Preserve Vision Following Cataract Surgery
- •8.3.4.1 Introduction
- •8.3.4.2 Why Filter Blue Light?
- •Summary
- •8.3.4.3 Importance of Blue Light to Cataract and Refractive Lens Exchange Patients
- •Summary
- •8.3.4.4 Quality of Vision with Blue Light Filtering IOLs
- •Summary
- •8.3.4.5 Clinical Experience
- •Summary
- •8.3.4.6 Unresolved Issues and Future Considerations
- •References
- •8.3.5 Microincision Intraocular Lenses: Others
- •8.3.5.1 ThinOptX®
- •8.3.5.2 Smart IOL
- •8.3.5.4 AcriTec
- •8.3.5.5 Akreos
- •8.3.5.7 Rayner
- •8.3.5.8 Injectable Polymers
- •8.3.5.9 Final Comments
- •References
- •9. Outcomes
- •9.1 Safety: MICS versus Coaxial Phaco
- •9.1.1 Introduction
- •9.1.2 Visual Outcomes
- •9.1.3 Incision Damage
- •9.1.4 Corneal Incision Burn
- •9.1.5 Corneal Changes
- •9.1.6 Infection
- •9.1.7 Summary
- •References
- •9.2 Control of Corneal Astigmatism and Aberrations
- •9.2.1 Introduction: Impacts of MICS Incision on the Outcomes of Cataract Surgery
- •9.2.2 Objective Evaluation of Corneal Incision
- •9.2.3 Control of Corneal Aberration and Astigmatism with MICS
- •9.2.4 Role of Corneal Aberrometry in Evaluating MICS Incision
- •9.2.5 Role of OCT in Evaluating MICS Incision
- •9.2.6 Our Experience in Corneal Aberrations and Astigmatism After MICS
- •9.2.7 Conclusion
- •References
- •9.3 Corneal Endothelium and Other Safety Issues
- •9.4 Incision Quality in MICS
- •9.4.1 Introduction: History of Incision Size Reduction
- •9.4.2 The Trends Towards Microincision Cataract Surgery (BMICS)
- •9.4.3 Advantages of Minimizing the Incision Size
- •9.4.4 Model for the Analysis of Corneal Incision Quality [21]
- •9.4.5 Our Protocol for Evaluation of Incision Quality in BMICS [21]
- •9.4.6 Results
- •9.4.6.1 Visual, Refractive and Biomicroscopic Outcomes
- •9.4.6.2 Incision Imaging (OCT) Outcomes
- •9.4.8 Conclusion
- •References
- •INDEX
214 |
J. L. Alió and P. Klonowski |
8.1.2.4IOLtech MICS lens (IOLtech, La Rochelle, France; and Carl Zeiss Meditec, Stuttgard, Germany)
This lens is biconvex. The total diameter is 12.0 mm and the optic diameter is 5.5 mm. The angulation is 130 between haptics and optics. This is a hydrophilic acrylic and monobloc lens. This lens has a square edge. The diopters range from +10.5 to +25.5 D. The lens can be implanted with a disposable injector and a micro incision cartridge. This lens shows pseudoaccommodative effect (Fig. 8.4).
Verges et al. (ESCRS congress, Portugal 2005, London 2006) showed data of 48 patients who underwent MICS and implantation of IOLtech MICS lens through 1.8 mm incision. After 1 year follow up, 92% of the patients reported UCDVA 20/25 and 96% BCDVA more than 20/25. Sixty-five percent of the patients achieved near visual acuity J3 with distant correction and 98% of the patients, J5. Only 2 patients needed Nd:YAG capsulotomy.
8.1.2.5TetraFlex KH-3500 and ZR-1000 (Lenstec, St. Petersburg, FL)
TetraFlex KH-3500 is the accommodating MICS IOLlens. It is made from hydroxyethylmethacrylate (HEMA) and consists of 26% water and the material is highly flexible. The lens is 11.5 mm in total length and 5.75-mm in optic length with square edges. It is a
Fig. 8.4 IOLtech MICS lens
Fig. 8.5 TetraFlex KH-3500
one-piece lens. The lens is available in powers from +5 to +36 D. The TetraFlex KH-3500 uses injector with 1.8-mm cartridge [19] (Fig. 8.5).
Wolffsohn et al. evaluated the accommodative ability of this lens. After surgery, distance BCVA was 0.06 (±0.13) logMAR and 0.58 (±0.2) logMAR at near. The objective accommodation was 0.39 (0.53)D and subjective accommodation was 3.1 (1.6) D. Six months following surgery, posterior subcapsular scatter had increased (p < 0.01) in the KH-3500 implanted subjects and near acuity had decreased (p < 0.05). In conclusion, authors suggest that the accommodative ability of the lens appears to have decreased by 6 months postsurgery [20].
Chitkara at the ESCRS Winter Refractive Surgery Meeting 2004 reported that the mean accommodation achieved binocularly was 3.42 D. Moreover, 89% of the patients achieved J3 or better unaided binocular near vision at 6 months, and 100% achieved J5 or better [21].
ZR-1000 is the new one-piece lens from Lenstec. The length of this lens is 11.0 mm. The diameter of the optic is 5.5 mm and is made in square edge technology. The optic type is equiconvex and the haptic is plate. The angulation is 00. This lens is made of 26% water content acrylic. The diopters of the lens range from +10.0 to +30.0 D. No clinical data are available for this lens (Fig. 8.6, Table 8.3).
8.1.2.6MicroSlim and SlimFlex MICS IOLs
(PhysIOL, Liège, Belgium)
MicroSlim IOL is a hydrophilic acrylic lens with biconvex optics. Optic diameter is 6.15 mm, and overall
8 IOL Types and Implantation Techniques |
|
|
215 |
||
Table 8.3 TetraFlex KH-3500 and ZR-1000 lens |
|
|
|
||
Lens |
Optic (mm) |
Angulation |
Range of |
Material |
Optic characteristic |
|
|
|
diopters (D) |
|
|
TetraFlex KH-3500 |
5.75 |
5 |
+5.0 to +36.0 |
Hydroxyethylmethacrylate (HEMA) |
Accommodating lens |
ZR-1000 |
5.5 |
0 |
+10.0 to +30.0 |
26% Water content acrylic |
Equiconvex |
Fig. 8.6 |
ZR-1000 IOL |
through 1.5 mm incision. A group of 50 patients |
|
|
underwent bilateral MICS with lens implantation. |
|
|
After 6 weeks, mean BCVA was 1.04. Less than 1% |
|
|
of the patients complained about halos or glare, and |
|
|
3% of lenses resulted in a small damage of the optic |
|
|
or haptics. No clinical data are available for this |
|
|
lens. |
|
|
8.1.2.7 CareFlex IOL (W20 Medizintechnik AG, |
|
|
Bruchal, Germany) |
|
|
This is a 26% hydrophilic acrylate, one-piece lens. |
|
|
Optic size is 5.8 mm, overall length is 10.5 mm and |
|
|
the haptic angulation is 0°. The optic design is bicon- |
|
|
vex. The recommended anterior chamber depth is |
|
|
5.1 mm. The lens is available from +10.0 to +30.0 D. |
|
|
No clinical data are available for this lens. |
|
|
8.1.2.8 AcriFlex MICS 46CSE IOL (Acrimed |
|
|
GmbH, Berlin, Germany) |
|
|
This lens is made of 25% acrylic hydrophilic. The |
|
|
superficial is hydrophobic. The lens diameter is 11.0 mm |
|
|
and optic diameter is 6.0 mm. This is a monobloque |
|
|
type lens with perforated haptics. The angulation is 0°. |
|
|
The optic is biconvex with sharp edges. The lens is |
|
|
available from +15 to +27 D. Clinical data are not avail- |
|
|
able for this lens (Fig. 8.8). |
Fig. 8.7 |
MicroSlim IOL |
8.1.2.9 Hoya Y-60H (Hoya Corporation, |
|
|
Tokyo, Yapan) |
diameter is 10.75 mm. The angulation is 50. The power of the lens range is from +10.0 to +30.0 D. This lens can be injected using Viscoject™ Injector and 1.8 Viscoglide cartridge (Medicel, Widnau, Switzerland). No clinical data are available for this lens (Fig. 8.7).
In the Congress of ESCRS 2006, Vryghem et al. presented their experience in SlimFlex IOL implantation
Hoya Y-60H is quite a new lens for micro surgery. This is a hydrophobic foldable lens. No clinical data are available, but Tsuneoka described possibility of implantation of this lens through 1.7 mm incision. He used Hoya F-1 cartridge to inject the lens [22] (Fig. 8.9).
