- •Preface
- •Contributors
- •Contents
- •Introduction
- •Literature Review
- •Major Issues
- •Major Studies
- •Negative Studies
- •References
- •1.1.1 Introduction
- •1.1.3 Torsional Ultrasound
- •1.1.4 Our Procedure for Emulsifying the Nucleus
- •References
- •1.2 Transitioning to Bimanual MICS
- •1.2.1 Introduction
- •1.2.2 Technique
- •1.2.3 Summary
- •1.3 0.7 mm Microincision Cataract Surgery
- •1.3.1 Sub 1 mm MICS: Why?
- •1.3.3 Instrumentation
- •1.3.3.2 0.7 mm Irrigating Instruments
- •1.3.4 Surgery
- •1.3.4.1 Incision
- •1.3.4.2 Capsulorhexis
- •1.3.4.3 Hydrodissection
- •1.3.4.4 Prechopping
- •1.3.5 0.7 mm MICS Combined Procedures
- •1.3.5.1 0.7 mm MICS and Glaucoma Surgery
- •1.3.6 Summary
- •References
- •2. MICS Instrumentation
- •2.1 MICS Instrument Choice: The First Step in the Transition
- •2.2 MICS Incision
- •2.3 MICS Capsulorhexis
- •2.4 MICS Prechopping
- •2.5 MICS Irrigation/Aspiration Instruments
- •2.5.1 19 G Instruments
- •2.5.2 21 G Instruments
- •2.6 MICS Auxiliary Instrument
- •2.6.1 Scissors
- •2.6.2 Gas Forced Infusion
- •2.6.3 Surge Prevention
- •2.7 New MICS Instruments
- •2.7.1 Flat Instruments
- •References
- •3.1 Introduction
- •3.2 Power Generation
- •3.3.1 Tuning
- •3.2.2 Phaco Energy
- •3.2.2.1 Low Frequency Energy
- •3.2.2.2 High Frequency Energy
- •3.2.3 Transient Cavitation
- •3.2.4 Sustained Cavitation
- •3.3.1 Alteration of Stroke Length
- •3.3.2 Alteration of Duration
- •3.3.2.1 Burst Mode
- •3.3.2.2 Pulse Mode
- •Micro Pulse (Hyper-Pulse)
- •Pulse Shaping
- •3.3.3 Alteration of Emission
- •3.4 Fluidics
- •3.5 Vacuum Sources
- •3.6 Surge
- •3.7.1 Micro-incisional Phaco
- •3.7.2 Bimanual Micro-Incisional Phaco
- •3.7.3 Micro-Incisional Coaxial Phaco
- •3.7.3.1 Irrigation and Aspiration
- •3.8 Conclusion
- •Reference
- •Further Reading
- •4.1 Introduction
- •4.3 Incision Size
- •4.4 Torsional Ultrasound
- •4.5 Conclusion
- •References
- •5. Technology Available
- •5.1 How to Better Use Fluidics with MICS
- •5.1.1 Physical Considerations
- •5.1.1.2 Chamber Stability
- •5.1.1.3 Holdability
- •5.1.2 Surgical Considerations
- •5.1.2.2 Phaco Technique
- •5.1.2.4 The OS3 and CataRhex SwissTech Platforms
- •Equipment
- •Machine Settings
- •5.2 How to Use Power Modulation in MICS
- •5.2.1 Introduction
- •5.2.3 The Concept of Unoccluded Flow Vacuum
- •5.2.4 The Intricacies of Ultrasound Power Modulation
- •5.2.5 The Variable Incidence of Wound Burn Rates
- •References
- •5.3 MICS with Different Platforms
- •5.3.1 MICS with the Accurus Surgical System
- •5.3.1.1 Introduction and Historic Background
- •5.3.1.3 Surgical Parameters for MICS with Accurus
- •5.3.1.4 Final Considerations
- •5.3.2.1 Introduction
- •5.3.2.7 Technology for MICS on the AMO Signature
- •5.3.2.8 Applying Signature Technology to CMICS and BMICS
- •5.3.3 MICS with Different Platforms: Stellaris Vision Enhancement System
- •5.3.3.2 Evaluating the Stellaris Vision Enhancement System
- •5.3.3.3 The Advantages of BMICS
- •References
- •6.1 Pupil Dilation and Preoperative Preparation
- •6.1.1 Managing the Small Pupil
- •6.1.2 Techniques that Depend on the Manipulation of the Pupil
- •6.1.3 Iris Surgery
- •6.1.4 Preoperative Preparation and Infection Prophylaxis
- •6.1.5 Evaluating Risk
- •6.1.6 Assessing Your Approach
- •6.1.7 Preventing Infection, Step by Step
- •6.1.8 Sample Protocol Outline
- •6.1.9 A Careful, Critical Eye
- •References
- •6.2 Incisions
- •References
- •6.3 Thermodynamics
- •6.3.1 Introduction
- •6.3.2 Corneal Thermal Damage
- •6.3.3 Heat Generation
- •6.3.4 Factors that Contribute to Thermal Incision Damage
- •6.3.4.1 Energy Emission: Amount and Pattern of How the Energy Is Delivered
- •6.3.4.3 Viscoelastic Devices and Possible Occlusion of the Aspiration Line
- •6.3.4.4 Irrigation Flow
- •6.3.4.5 Position of the Tip Inside the Incision
- •6.3.4.6 Tip Design
- •6.3.4.7 Surgical Technique
- •6.3.5 Conclusion
- •6.4 Using Ophthalmic Viscosurgical Devices with Smaller Incisions
- •6.4.1 Introduction
- •6.4.1.1 The Nature of OVDs: Rheology
- •6.4.1.3 Soft Shell and Ultimate Soft Shell Technique (SST & USST)
- •6.4.2 Routine, Special and complicated Cases
- •6.4.2.1 Phakic and Anterior Chamber IOLs
- •6.4.2.3 Fuchs’ Endothelial Dystrophy
- •6.4.2.5 Capsular Staining for White & Black Cataracts
- •6.4.2.6 Flomax® Intraoperative Floppy Iris Syndrome USST
- •6.4.3 Discussion
- •References
- •6.5 Capsulorhexis
- •References
- •References
- •6.7 Biaxial Microincision Cataract Surgery: Techniques and Sample Surgical Parameters
- •6.8.1 Surgical Technique
- •6.8.2 Advantages
- •6.8.3 Disadvantages
- •6.8.4 Final Thoughts
- •References
- •6.9 BiMICS vs. CoMICS: Our Actual Technique (Bimanual Micro Cataract Surgery vs. Coaxial Micro Cataract Surgery)
- •6.9.1 Introduction
- •6.9.2 Historical Background
- •6.9.3 BiMICS. BiManual MicroIncision Cataract Surgery
- •6.9.3.1 Introduction
- •6.9.3.2 Instrumentation
- •6.9.3.5 Phacotips
- •6.9.3.6 Capsulorhexis
- •6.9.3.7 Phaco Knives
- •6.9.3.8 The Phaco Machines
- •6.9.3.9 Phaco Pumps
- •6.9.3.10 Ultrasound Power Delivery
- •6.9.3.11 IOL Implantation
- •6.9.3.12 Astigmatism
- •6.9.4.1 Capsulorhexis
- •6.9.4.2 Phacotips
- •6.9.4.3 The Phaco Machines
- •6.9.4.4 Phaco Pumps
- •6.9.4.5 Ultrasound Power Delivery
- •6.9.4.6 Irrigation-Aspiration
- •6.9.4.7 Incision-Assisted IOL Implantation
- •6.9.5 Conclusion
- •References
- •6.10 Endophthalmitis Prevention
- •6.10.1 Antibiotic Prophylaxis
- •6.10.2 Wound Construction
- •6.10.3 Summary
- •References
- •7.1 High Myopia
- •7.2 Posterior Polar Cataract
- •7.3 Posterior Subluxed Cataracts
- •7.4 Mature Cataract with Zonular Dialysis
- •7.5 Punctured Posterior Capsule
- •7.6 Posterior Capsule Rupture
- •7.7 Pseudoexfoliation
- •7.8 Rock-Hard Nuclei
- •7.9 Switching Hands
- •7.10 Microcornea or Microphthalmos
- •7.11 Large Iridodialysis and Zonular Defects
- •7.12 Intraoperative Floppy Iris Syndrome (IFIS)
- •7.14 Iris Bombé
- •7.15 Very Shallow Anterior Chambers
- •7.16 Refractive Lens Exchange
- •7.18 Intraocular Cautery
- •7.19 Biaxial Microincision Instruments
- •References
- •7.1 MICS in Special Cases: Incomplete Capsulorhexis
- •7.1.1 Introduction
- •7.1.2 Avoiding Complications While Constructing Your Microcapsulorhexis
- •7.1.3 Avoiding Complications During Biaxial Phaco with an Incomplete Capsulorhexis
- •7.1.4 Avoiding Complications During IOL Insertion with an Incomplete Capsulorhexis
- •7.1.5 Conclusions
- •References
- •7.2 MICS in Special Cases (on CD): Vitreous Loss
- •7.2.1 Introduction
- •7.2.2 Posterior Capsule Tears and Vitreous Prolapse
- •7.2.3 Vitreous and the Epinucleus or Cortex
- •7.2.4 Different Techniques Other than Pars Plana Vitrectomy for Nuclear Loss in Vitreous
- •7.2.5 Pars Plana Vitrectomy
- •7.2.6 Zonulolysis
- •References
- •7.3 How to Deal with Very Hard and Intumescent Cataracts
- •7.3.1 Introduction
- •7.3.2 Types of Cataracts
- •7.3.3 Management of Hard Cataracts Through Biaxial Technique
- •7.3.4 Incision
- •7.3.5 Capsulorrhexis
- •7.3.6 Hydrodissection
- •7.3.8 Conclusion
- •References
- •8. IOL Types and Implantation Techniques
- •8.1 MICS Intraocular Lenses
- •8.1.1 Introduction
- •8.1.2 Lenses
- •8.1.2.2 ThinOptX MICS IOLs (ThinOptX, Abingdon, VA)
- •8.1.2.3 Akreos MI60 AO Micro Incision IOL (Bausch & Lomb, Rochester, NY)
- •8.1.2.4 IOLtech MICS lens (IOLtech, La Rochelle, France; and Carl Zeiss Meditec, Stuttgard, Germany)
- •8.1.3 Optical Quality of MICS IOLs
- •8.1.4 Conclusion
- •References
- •8.2 Implantation Techniques
- •8.2.2 Prerequisites to a Sub-2 Injection
- •8.2.3 IOLs Used for Injection Through Microincision
- •8.2.3.1 Material
- •8.2.3.2 Design
- •8.2.3.3 Optic Design
- •8.2.3.4 Haptic Design
- •8.2.3.5 Posterior Barrier (360°)
- •8.2.4 Injectors Meant for Microincision
- •8.2.4.1 Objectives of Injectors Meant for Microincision
- •8.2.4.2 Characteristics of Sub-2 Injectors
- •8.2.4.3 The Cartridges
- •Loading Chambers
- •Injection Tunnels and Cartridge Tips
- •8.2.4.4 The Plunger Tips (or plunger)
- •8.2.4.5 Pushing Systems
- •8.2.4.6 Injector Bodies
- •8.2.4.7 Principal Sub-2 Injectors
- •8.2.5 Visco Elastic Substances and Injection Through Microincision
- •8.2.6 Techniques of Sub-2 Injection
- •8.2.6.2 Incision Construction
- •8.2.6.3 Pressurization of the Anterior Chamber
- •8.2.6.4 Loading the Cartridge
- •8.2.6.5 Loading the Injector
- •8.2.6.6 Insertion of the Plunger Tip
- •8.2.6.7 Injection in the Anterior Chamber
- •8.2.6.8 Positioning the IOL in the Capsular Bag
- •8.2.6.9 Removing the VES
- •8.2.6.10 Thin Roller Injector
- •8.2.6.11 Conclusion
- •Reference
- •8.3 Special Lenses
- •8.3.1 Toric Posterior Chamber Intraocular Lenses in Cataract Surgery and Refractive Lens Exchange
- •8.3.1.1 Introduction
- •8.3.1.3 T-IOL Calculation
- •8.3.1.4 Current T-IOL Models
- •8.3.1.5 Preoperative Marking
- •8.3.1.6 Clinical Indications
- •8.3.1.7 Custom-Made Lenses
- •8.3.1.8 Conclusion for Practice
- •References
- •8.3.2 Special Lenses: MF
- •8.3.2.1 Discussion
- •8.3.2.2 Conclusion
- •8.3.2.3 Outlook
- •References
- •8.3.3 Special Lenses: Aspheric
- •References
- •8.3.4 Intraocular Lenses to Restore and Preserve Vision Following Cataract Surgery
- •8.3.4.1 Introduction
- •8.3.4.2 Why Filter Blue Light?
- •Summary
- •8.3.4.3 Importance of Blue Light to Cataract and Refractive Lens Exchange Patients
- •Summary
- •8.3.4.4 Quality of Vision with Blue Light Filtering IOLs
- •Summary
- •8.3.4.5 Clinical Experience
- •Summary
- •8.3.4.6 Unresolved Issues and Future Considerations
- •References
- •8.3.5 Microincision Intraocular Lenses: Others
- •8.3.5.1 ThinOptX®
- •8.3.5.2 Smart IOL
- •8.3.5.4 AcriTec
- •8.3.5.5 Akreos
- •8.3.5.7 Rayner
- •8.3.5.8 Injectable Polymers
- •8.3.5.9 Final Comments
- •References
- •9. Outcomes
- •9.1 Safety: MICS versus Coaxial Phaco
- •9.1.1 Introduction
- •9.1.2 Visual Outcomes
- •9.1.3 Incision Damage
- •9.1.4 Corneal Incision Burn
- •9.1.5 Corneal Changes
- •9.1.6 Infection
- •9.1.7 Summary
- •References
- •9.2 Control of Corneal Astigmatism and Aberrations
- •9.2.1 Introduction: Impacts of MICS Incision on the Outcomes of Cataract Surgery
- •9.2.2 Objective Evaluation of Corneal Incision
- •9.2.3 Control of Corneal Aberration and Astigmatism with MICS
- •9.2.4 Role of Corneal Aberrometry in Evaluating MICS Incision
- •9.2.5 Role of OCT in Evaluating MICS Incision
- •9.2.6 Our Experience in Corneal Aberrations and Astigmatism After MICS
- •9.2.7 Conclusion
- •References
- •9.3 Corneal Endothelium and Other Safety Issues
- •9.4 Incision Quality in MICS
- •9.4.1 Introduction: History of Incision Size Reduction
- •9.4.2 The Trends Towards Microincision Cataract Surgery (BMICS)
- •9.4.3 Advantages of Minimizing the Incision Size
- •9.4.4 Model for the Analysis of Corneal Incision Quality [21]
- •9.4.5 Our Protocol for Evaluation of Incision Quality in BMICS [21]
- •9.4.6 Results
- •9.4.6.1 Visual, Refractive and Biomicroscopic Outcomes
- •9.4.6.2 Incision Imaging (OCT) Outcomes
- •9.4.8 Conclusion
- •References
- •INDEX
Minimizing Incisions and Maximizing
Outcomes in Cataract Surgery
Jorge L. Alió
I. Howard Fine (Eds.)
Minimizing Incisions
and Maximizing
Outcomes
in Cataract Surgery
Jorge L. Alió, MD, PhD |
I. Howard Fine, MD |
Professor and Chairman of Ophthalmology |
Oregon Health & Science University |
Vissum |
Drs. Fine, Hoffman and Packer |
Instituto Oftalmológico de Alicante |
1550 Oak Street, Suite 5, Eugene |
Miguel Hernández University |
OR 97401, USA |
Department of Ophthalmology |
hfine@finemd.com |
Av. de Denia, s/n |
|
03016 Alicante |
|
Spain |
|
jlalio@vissum.com |
|
ISBN: 978-3-642-02861-8 |
e-ISBN: 978-3-642-02862-5 |
DOI: 10.1007/978-3-642-02862-5
Springer Heidelberg Dordrecht London New York
Library of Congress Control Number: 2009931052
© Springer-Verlag Berlin Heidelberg 2010
This work is subject to copyright. All rights are reserved, whether the whole or part of the material is concerned, specifically the rights of translation, reprinting, reuse of illustrations, recitation, broadcasting, reproduction on microfilm or in any other way, and storage in data banks. Duplication of this publication or parts thereof is permitted only under the provisions of the German Copyright Law of September 9, 1965, in its current version, and permission for use must always be obtained from Springer. Violations are liable to prosecution under the German Copyright Law.
The use of general descriptive names, registered names, trademarks, etc. in this publication does not imply, even in the absence of a specific statement, that such names are exempt from the relevant protective laws and regulations and therefore free for general use.
Product liability: The publishers cannot guarantee the accuracy of any information about dosage and application contained in this book. In every individual case the user must check such information by consulting the relevant literature.
Cover design: eStudio Calamar, Figueres/Berlin
Printed on acid-free paper
Springer is part of Springer Science+Business Media (www.springer.com)
This book is dedicated to the privilege of working with I. Howard Fine, an excellent professional model and a most highly esteemed friend and mentor, dedicated to his talent in creating progress in cataract surgery, teaching others, working hard and meticulously, being precise, and always behaving like a really good person. It has been an honour to work with Howard on this book, immediately prior to his retirement and sabbatical. I do not know anyone who really deserves it more.
Jorge Alió
Preface
This book appears at a moment in which cataract surgery is probably making the last evolution in technology and surgical practice, according to the postulates that Charles Kelman started in the early 70s. The progressive transition from the initial concept of small inicision cataract surgery, the development of more and more sophisticated technology to support the surgeon’s practice of the procedure, the development of intraocular lenses capable of correcting virtually all types of refractive errors, and the scientific knowledge available today on fluidics, micromechanics, biomaterials, viscomaterials, and surgical instrument technology has made cataract surgery experience one of the greatest progressions and advances of a surgical technique throughout the history of medicine and surgery.
Cataract surgery at the moment is transforming into a practice in which minimal agressiveness and optimized outcomes are targeted and tried to achieve by surgeons. Better diagnostic technology, sophistication in calculation formulas for IOL implantation, better instruments for incisions, and deeper knowledge into the structure of the cornea and corneal optics, greater knowledge into issues related intraocular lens performance, the approach to solve pseudophakic presbyopia by multifocal or accommodative lenses are, among many others, issues that have been recently advancing cataract surgery toward its next stage.
Throughout this process, the history of cataract surgery has been related to the decrease in incision size. This is why an important part of this book is targeting biaxial microincisional surgery, which seems to be mandatory in the future evolution of cataract removal. Simplification of the procedure and separation of irrigation and aspiration seems to be related to better outcomes supported by current scientific evidence. This is possible, thanks to a better knowledge of the instrumentation, fluidics, use of ultrasound power, and indeed surgical knowledge and training. The development of new lenses capable of fitting through smaller incisions than those currently available seems to be a limit to the development of the technology. Today, we can precisely limit our capabilities for cataract removal to 1.6 mm and to 1.8 mm with IOL implantation. Throughout this book, the reader will be able to learn about the methods to achieve this benchmark of cataract surgery at this moment.
As we have already mentioned in our opinion, this book appears during the final stage of the evolution of cataract surgery as conceived today. We anticipate that sub 1 mm surgery will require new technologies, and especially, new IOL technology and biomaterials. Most probably, we are at the end of the revolution that was started by Charlie Kelman in the early 70s and in the next decade we shall start a new evolution toward new issues such as lens replacement through new biomaterials, new
vii
viii |
Preface |
accommodating lenses, regenerating surgery, and new technologies to soften the cataract and to eliminate it through punctures rather than through incisions.
We both, as co-authors, think that the readers will enjoy going through this book to discover the real cutting edge but practical image offered today by high-quality cataract surgery practice. We thank all the co-authors of this book, all of them most relevant professionals and surgical scientists, for their contribution to this book and to the progress of cataract surgery. Thanks to them and to the support of our families, this book appears ready to go to your operating room as an advisor for your progression toward the last transition that cataract surgery will experience with the technology available today.
Alicante, Spain |
Jorge L. Alió |
Eugene, Oregon, USA |
I. Howard Fine |
