Добавил:
kiopkiopkiop18@yandex.ru t.me/Prokururor I Вовсе не секретарь, но почту проверяю Опубликованный материал нарушает ваши авторские права? Сообщите нам.
Вуз: Предмет: Файл:

Ординатура / Офтальмология / Английские материалы / Mastering Corneal Collagen Cross-linking Techniques (C3-R CCL CxL)_Garg, Kanellopoulos, O'Brart, Lovisolo, Pinelli_2008

.pdf
Скачиваний:
0
Добавлен:
28.03.2026
Размер:
8.13 Mб
Скачать

CORNEAL COLLAGEN CROSS-LINKING IN KERATOCONUS

Figure 16.2: UVA radiation with riboflavin 0.1%

One month after cross-linking treatment, contact lens use could be started. The durability of the stiffening effect is unknown. Because the collagen turnover in the cornea is estimated to be between 2 to 3 years, a repeat treatment may become necessary in the long run.3,11

CLINICAL RESULTS

The first clinical results of collagen cross-linking in keratoconus were reported by a research group from Dresden University in 2003. In this study, 23 eyes of 22 patients with keratoconus were included and only one eye of each patient was treated except one case that was treated bilaterally. The follow-up period was from 3 to 47 (23.2 ± 12.9) months. The BCVA improved in 65% of the patients by an average of 1.26 lines. The refractive correction improved by an average of 1.14D. In 70% of the patients, maximum K was flattened by an average of 2.01 D. K value remained stable in 5 patients and in 1 patient, an increase of 0.28 D was present. In 22% of the fellow control eyes, however, maximum K value increased by an average of 1.48D.3 The same research group later published their longterm results in 2008 on 153 eyes of 111 patients. The minimal follow-up time was 12 months and the maximum follow-up time was 7.5 years. Keratectasia significantly decreased in the 1st year by 2.29 D, in the 2nd year by 3.27 D, and in the 3rd year by 4.34 D. Visual acuity improved significantly in at least one

line or remained stable (i.e., no line loss) in the 1st year in 48.9% and 23.8%, respectively; in the 2nd year in 50.7% and 29.6%, respectively; and in the 3rd year in 60.6% and 36.4%, respectively. No severe side effects were observed. Three patients showed continuous progression of keratoconus and received cross-linking treatment again.12

Wiitig-Silva C et al reported the preliminary results of a randomized, controlled trial enrolling 66 eyes of 49 patients with documented progression of keratoconus. Interim analysis of treated eyes showed a flattening of the steepest simulated keratometry value (K-max) by an average of 0.74 diopters (D) at 3 months, 0.92 D at 6 months, and 1.45 D at 12 months. A trend toward improvement in best spectacle-corrected visual acuity was also observed. In the control eyes, mean K- max steepened by 0.60 D after 3 months, by 0.60 D after 6 months, and by 1.28 D after 12 months. Best spectacle-corrected visual acuity decreased by logMAR 0.003 (P = .883) over 3 months, 0.056 (P = .092) over 6 months, and 0.12 (P = .036) over 12 months. No statistically significant changes were found for spherical equivalent or endothelial cell density. These results suggest stabilization of cross-linked eyes.13

Cross-linking has also been effective following inferior-segment INTACS implantation. The addition of collagen cross-linking to the INTACS procedure resulted in greater reduction in cylinder, steep and average keratometry and lower-upper ratio in corneal topography than INTACS insertion alone.14

Since cross-linking stabilized keratoconus, the idea of treating the refractive error with PRK after crosslinking evolved. One year after cross-linking treatment, PRK was performed in one eye of a keratoconus case and an UCVA of 20/20 was achieved. This refractive result remained stable during a follow-up period of 18 months.15

RISKS AND SIDE EFFECTS

The harmful effects of UV light to the eye such as photokeratitis is well-known. This photochemical damage is caused, however, by UV-B-light. Corneal epithelium mainly absorbs UV-B (290-320 nm) in photokeratitis.2

In cross-linking treatment, a small peak-like sector of the UV-A spectrum (370 nm) is used. By the help of

photosensitizer riboflavin, UV-A absorption in the 9 5

MASTERING CORNEAL COLLAGEN CROSS-LINKING TECHNIQUES

cornea is increased, resulting in a UV-A transmission of only 7% across the cornea.2 In rabbit eyes, the cytotoxicity threshold for corneal endothelial cells is 0.36 mW/cm’. By using standard surface UVA dose of 3 mW/cm2, this cytotoxic level could only be reached if the cornea is thinner than 400 μm. Therefore, in thinner corneas, irradiation should not be performed because of the cytotoxic risk to the endothelium.16,17

The cataractogenic dose of UV-A is 70 J/cm2. With the current treatment parameters, the lens only receives 0.65 J/cm2 which is far below the cataractogeneous level. In addition, lens damage is usually induced by UV-B light which has a higher energy because of a shorter wavelength than UV-A.3

The retinal damage with complete loss of photoreceptor layer in rhesus monkeys was reported at a UVA dose of 81 mW/cm2 which is not reached with the standard treatment protocol.2

In the early clinical studies of cross-linking, no side effects other than transient corneal edema and foreign body sensation which lasts 24-48 hours were reported.

No persistent epithelial defect of the cornea, endotheliopathy, cataract and glaucoma were observed. However in 2007, corneal haze after collagen linking was reported by various authors. In one case report, corneal haze after cross-linking treatment for keratoconus disappeared only gradually despite intensive topical anti-inflammatory therapy.18 In a clinical study, haze that is not effecting vision was developed in 2 of 5 eyes with grade 3 keratoconus (according to Krumeich keratoconus clinical staging). No haze was observed in grade I or II eyes. In vivo confocal microscopy of the eyes that developed haze revealed reticular hyporeflective microstriae preoperatively. The authors suggested that the detection of reticular hypo-reflective microstriae by in vivo confocal analysis could represent a relative contraindication to perform cross-linking.19

The effect of cross-linking treatment on epithelium and subepithelial/stromal nerve plexus was studied by in vivo HRT II confocal microscopy in humans. The epithelium reached regular morphology and density in 5 days. Disappearance of subepithelial stromal nerve fibers was observed in the central irradiated area where, 1 month after the operation, initial reinnervation was observed. Six months after the operation, the anterior subepithelial stroma recolonized by nerve

9 6 fibers with restoration of corneal sensitivity.20

Corneal melting on a case with severe atopic disease and keratoconus following cross-linking and deep anterior lamellar keratoplasty (DALK) due to subclinical infection with Herpes simplex virus (HSV) was reported. Penetrating keratoplasty and intensive antiviral and immunosuppressive medical treatment were necessary to control that infection.21

REFERENCES

1.Feder RS, Kshettry P. Noninflammatory ectatic disorders. In: Krachmer JH, Mannis MJ, Holland EJ, (Eds): Cornea, China, Elsevier Mosby 2005;955-74.

2.Wollensak G. Cross-linking treatment of progressive keratoconus: new hope. Curr Opin Ophthalmol 2006;17(4):356-60.

3.Wollensak G, Spoerl E, Seiler T. Riboflavin/ultraviolet-a- induced collagen cross-linking for the treatment of keratoconus. Am J Ophthalmol 2003;135(5):620-27.

4.Wollensak G, Spoerl E, Seiler T. Stress-strain measurements of human and porcine corneas after riboflavin-ultraviolet—A induced cross-linking. J Cat Refract Surg 2003;29(9):1780-85.

5.Spoerl E, Wollensak G, Dittert DD, Seiler T. Thermomechanical behavior of collagen-cross-linked porcine cornea. Ophthalmologica 2004;218(2):136-40.

6.Wollensak G, Wilsch M, Spoerl E, Seiler T. Collagen fiber diameter in the rabbit cornea after collagen cross-linking by riboflavin/UVA. Cornea 2004;23(5):503-07.

7.Spoerl E, Wollensak G, Seiler T. Increased resistance of crosslinked cornea against enzymatic digestion. Curr Eye Res 2004;29(1):35-40.

8.Wollensak G, Redl B. Gel electrophoretic analysis of corneal collagen after photodynamic cross-linking treatment. Cornea 2008;27(3):353-56.

9.Wollensak G, Aurich H, Pham DT, Wirbelauer C. Hydration behavior of porcine cornea crosslinked with riboflavin and ultraviolet A. J Cataract Refract Surg 2007;33(3):516-21.

10.Wollensak G, Spoerl E, Wilsch M, Seiler T. Keratocyte apoptosis after corneal collagen cross-linking using riboflavin/UVA treatment. Cornea 2004;23(1):43-49.

11.Mazzotta C, Balestrazzi A, Traversi C, Baiocchi S, Caporossi T, Tommasi C, Caporossi A. Treatment of progressive keratoconus by riboflavin-UVA-induced cross-linking of corneal collagen: ultrastructural analysis by Heidelberg Retinal Tomograph II in vivo confocal microscopy in humans. Cornea 2007;26(4):390-97.

12.Hoyer A, Raiskup-Wolf F, Spoerl E, Pillunat LE. Collagen cross-linking with riboflavin and UVA light in keratoconus–results from Dresden. Ophthalmologe 2008;e-pub ahead of print).

13.Wittig-Silva C, Whiting M, Lamoureux E, Lindsay RG, Sullivan LJ, Snibson GR. A randomized controlled trial of corneal collagen cross-linking in progressive keratoconus: preliminary results. J Refract Surg 2008;24(7):720-25.

CORNEAL COLLAGEN CROSS-LINKING IN KERATOCONUS

14.Chan CC, Sharma M, Wachler BS. Effect of inferior-segment Intacs with and without C3-R on keratoconus. J Cataract Refract Surg 2007;33(1):75-80.

15.Kanellopoulos AJ, Bindr PS. Collagen cross-linking (CCL) with sequential topography-guided PRK: a temporizing alternative for keratoconus to penetrating keratoplasty. Cornea 2007;26(7):891-95.

16.Wollensak G, Spoerl E, Wilsch M, Seiler T. Endothelial cell damage after riboflavin-ultraviolet-A treatment in the rabbit. J Cat Refract Surg 2003;29(9):1786-90.

17.Wollensak G, Spoerl E, Reber F, Pillunat L, Funk R. Corneal endothelial cytotoxicity of riboflavin/UVA treatment in vitro. Ophthalmic Res 2003;35(6):324-28.

18.Herrmann CI, Hammer T, Duncker GI. Haze formation (corneal scarring) after cross-linking therapy in keratoconus. Ophthalmologe 2007; [Epub ahead of print]

19.Mazzotta C, Balestrazzi A, Baiocchi S, Traversi C, Caporossi A. Stromal haze after combined riboflavin-UVA corneal collagen cross-linking in keratoconus: in vivo confocal microscopic evaluation. Clin Experiment Ophthalmol 2007;35(6):580-82.

20.Mazzotta C; Traversi C, Baiocchi S, Sergio P, Caporossi T, Caporossi A. Conservative treatment of keratoconus by riboflavin-UVA-induced cross-linking of corneal collagen: qualitative investigation. Eur J Ophthalmol 2006;16(4):530-35.

21.Eberwein P, Auw-Hadrich C, Bimbaum F, Maier PC, Reinhard T. Corneal melting after cross-linking and deep lamellar keratoplasty in a keratoconus patient. Klin Monatsbl Augenheilk 2008;225(1):96-98.

9 7

9 8

24-26
18-23
14-17

CORNEAL COLLAGEN CROSS-LINKING WITH RIBOFLAVIN (C3-R) COMBINED WITH INTRASTROMAL RING SEGMENT IMPLANTATION

INTRODUCTION

Since the 18th century’s first description of keratoconus,1,2 the ophthalmic community has long been searching for a method to stop the potentially devastating progression of the most common, naturally occurring, non-inflammatory ectatic corneal disorder. Generally bilateral, most often asymmetrical, keratoconus is characterized by ongoing stromal thinning and anterior bulging of both corneal surfaces, with the apex of the cone-shaped change located paracentrally and inferiorly.3-5 The resulting conicoid geometry of the corneal surface gives rise to unstable, irregular myopic astigmatism and asymmetrical high order aberrations,6 which can be adequately corrected by spectacles and soft contact lenses only in early stages. In mid-advanced phases, quality of vision and quality of life improvements have been usually considered as secondary aims, obtainable in the minority of cases, unless a corneal transplantation is performed, the last option to restore corneal architecture and improve eyesight.7-12 Until a genetic cure will be available, the only conservative weapon against mid-advanced keratoconus in the classic eye care armamentarium has been the rigid gas-permeable (RGP) contact lens (CL) wear, still the mainstay of the optical management of the disorder.13 The observation of some reshaping effect (a sort of “good” warpage) induced by hard CL wear on the surfaces of the cornea (corneal molding) led to the common misconception that these lenses may play a therapeutic role in arresting the evolution of the disease. Unfortunately, this statement turned out not to be true; instead, it is now clear that inadequacy of tear exchange and/or apical clearance may cause hypoxic damage and scarring of the apex of the cone, thus accelerating the way to the keratoplasty. More recently, the diffusion of reversed geometry overnight wear of CLs to temporarily correct slight myopic errors (modern orthokeratology) added a contribution to the knowledge on the plasticity of the cornea and the remodelling effect induced by a rigid contact lens was based on a more standardized approach. Eye care providers are now aware of the high sensitivity of the keratoconic cornea to be moulded, so that even a slight rubbing may alter the corneal topography,27 thus influencing its surface regularity indices and visual performance. In virgin keratoconus eyes, overnight

corneal molding (Figure 17.1) is rarely applied because

 

of the major inconvenience of effect’s duration that is

 

too short for practical reason. Actually, even the nicest

 

reshaping does not last longer than 3 hours after the

 

CL wear is suspended, and uncorrected visual acuity

 

rapidly falls under 20/40, considered the threshold to

 

comfortably perform regular daily activities.

 

A 10-year experience on intrastromal corneal ring

 

(ICR) segments (INTACS, KeraRing, Ferrara Ring)

 

implantation in keratoconus has shown that the

 

surgical placement of PMMA inserts into the deep

 

stroma of ectatic corneas is a safe procedure. It has the

 

potential to recover a more physiological position (in

 

front of the pupil and close to the visual axis) of the

 

displaced apex of the cone and to reduce the values

 

of irregular astigmatism, therefore improving both

 

unaided and best spectacle-corrected visual acuity.

 

Postoperatively, all the indices of topographic

 

regularity (semimeridian profile, corneal uniformity…)

 

improve with lower power variance and minimal

 

change of asphericity. Better contact lens fitting and

 

tolerance28-30 have been frequently observed (Figures

 

17.2A to D).

 

For unknown reasons, yet to be studied, we

 

anecdotally observed that the corneal surface

 

reshaping obtained with the wear of a customized

 

reversed geometry contact lens lasts longer (in some

 

cases even two to three days) in keratoconic eyes

 

already implanted with intrastromal ring segments. In

 

the last 5 years, therefore, the combination of ICR

 

(mainly Ferrara Ring, INTACS are utilized in less than

 

10% of cases) and custom designed RGP CL overnight

 

corneal molding performed not earlier than one

 

month after surgery has been our procedure of choice

 

in the management of progressive keratoconus.

 

The recent introduction of the C3-R (Corneal

 

Collagen Cross-linking with Riboflavin), a minimally

 

invasive para-surgical technique that induces a photo-

 

polymerization of the altered stromal collagen

 

fibers64-66 by the combined action of a photosensitising

 

substance (riboflavin, vitamin B2) and ultraviolet A

 

light exposure emitted at 370 nm from a suitable

 

source (Figures 17.3A to D) has shown the ability to

 

safely increase of at least three times the corneal rigidity

 

by strengthening the collagen stromal structure, thus

 

stabilizing ectatic corneal disorders31-37 and inducing

 

a moderate improvement of corneal surface irregularity

9 9

and visual acuity over time.

MASTERING CORNEAL COLLAGEN CROSS-LINKING TECHNIQUES

Figure 17.1: The Wood light fluorescein images immediately after reverse-geometry RGP lens fitting in a stage II KC eye (a) and two hours later (b). After RGP corneal molding, tangential topography (d) and corneal aberrometry elevation map (f) show a more uniform pattern. Pre-molding tangential and corneal elevation wavefront maps are shown in c and e, respectively. A significant decrease of all high order aberrations is evident in f

Due to the corneal sub-edema, small changes of aided and unaided visual vision were observed during early recovery. Moderate improvements started from the third month. Two and three-year data showed a significant reduction of the spherical equivalent and of the mean K-reading detected topographically (about 2.00 D), as well as a positive change of the topographic indices of corneal morphology and symmetry, with a reduction in lower order (myopic astigmatism) and higher order aberrations (coma in particular), which may explain the improvement in uncorrected and best- spectacle-corrected visual acuity. Patients often describe a better quality of vision with less ghosting, glare and starbursting around light sources at night, despite an almost unchanged corneal topography. The optical and visual performances improvement seems to be related to an increased corneal symmetry induced by a restored corneal rigidity after collagen shrinkage.56-59

The knowledge on the combination of C3-R and ICR is very limited; after C3-R, a complete apoptotic 100 damage of keratocytes and mild inflammatory reaction

occur. Cell loss is completely repaired by keratocyte repopulation by six weeks, when cytoarchitecture of the cornea seemed back to normal;34 it is therefore considered advisable to perform ICR implantation not earlier than six months post-C3-R for safety reasons. Before these data were available, however, we implanted ten eyes six months after C3-R and twelve eyes immediately before C3-R. In all patients, we found no specific complication but a significant reduction of the expected reshaping effect of the corneal surface. Instead, C3-R application after ICR surgery (from three months to years) has shown to augment the positive effect of ICR segment surgery in all cases (Carlo Lovisolo, unpublished data).

PURPOSE, METHODS AND MATERIALS

To determine whether a triple procedure, i.e. the addition of C3-R to our standard approach (ICR surgery plus corneal molding) may be more effective to treat keratoconus, we performed a retrospective nonrandomized comparative case series study.

CORNEAL COLLAGEN CROSS-LINKING WITH RIBOFLAVIN (C3-R) COMBINED WITH INTRASTROMAL RING SEGMENT IMPLANTATION

Figures 17.2A to D: KeraRing (Ferrara Ring) PMMA segments (A) have 160° of arc, 5.0 mm optical zone (B) and a triangular shape (C). The tangential topography difference map (D) shows the average expected outcome (anterior surface steepens over the segment bodies, then a progressive flattening occurs) after implantation of one infratemporal Ferrara ring segment in a stage II keratoconus

The outcomes of 18 eyes (10 patients), who received

was completed with a gentian violet inked instrument

 

KeraRing (Ferrara Ring) implantation plus overnight

under topical anesthesia, suction was applied and a

 

corneal molding with customized CLs (Group A) were

0.9 mm long, 70% of pachymetry reading deep

 

compared to the results observed in 15 eyes (12

incision, connected to two intrastromal tunnels of

 

patients), who had KeraRing (Ferrara Ring) surgery

5 mm of diameter (5.4 mm and 6.4 mm of internal

 

combined to overnight corneal molding and a C3-R

and external diameter, respectively) were created with

 

treatment (Group B). All the selected eyes had stage II

the femtosecond laser (IntraLase Fs Laser, Advanced

 

or stage III keratoconus according to the Ferrara-Amsler

Medical Optics, Inc., Santa Ana, CA, USA). The

 

classification,28 i.e. they showed a best-spectacle-

incision was placed on the coma axis as identified by

 

corrected visual acuity (BSCVA) lower than 20/50, with

the CSO videokeratographer (Firenze, Italy) (Figures

 

evident distortion of the keratometric mires, mean

17.4A and B).

 

central K-readings from 48.0 to 58.0 D, biomicroscopic

 

 

LINK TO THE VIDEO

 

signs of altered corneal profile like the Vogt’s striae

 

and a significant thinning at the cone apex, with

The choice of segment thickness and symmetrical or

 

minimal corneal pachymetry readings higher than 400

asymmetrical combination was made on the basis of

 

μm and were intolerant to conventional CL wear.

the KC type and stage, the degree of coma, astigmatism

 

Phase 1: Intrastromal Ring Segment Insertion was

and corneal irregularity, on the basis of the Lovisolo

101

performed as the first procedure. After corneal marking

nomograms.28 After vancomycin rinsing of the

MASTERING CORNEAL COLLAGEN CROSS-LINKING TECHNIQUES

Figures 17.3A to D: Surgical table prepared for C3-R (A) and two phases of UV-A light irradiation under 0.1% riboflavin-5-phosphate and dextran solution application (B, C) of the VEGA CBM X-LinkerTM (CSO, Firenze, Italy) (D)

Figures 17.4A and B: As the most effective correction occurs when the ring segments are positioned on the coma direction, a corneal aberrometry-based software is utilized to choose the site of incision, which is usually positioned on the coma axis (A), instead than on the steepest topographic meridian. In the example shown in (B), the topographic steep axis was 7°, while

102 the coma axis was 49°. The video shows the tunnel creation by the Femtosecond laser (IntraLase, AMO)

CORNEAL COLLAGEN CROSS-LINKING WITH RIBOFLAVIN (C3-R) COMBINED WITH INTRASTROMAL RING SEGMENT IMPLANTATION

Figures 17.5A to D: Site of incision and segment placement positions are marked (A). As an alternative to the femtolaser, the incision cut, the pocketing and the channelization may be performed manually (B,C,D) with appropriate instrumentation

channels was made, the plastic ring segments were positioned. Incision borders were gently hydrated and left sutureless in all cases. A 65% hydration, 8.7-mm base curve soft bandage contact lens was applied. Then a regimen of antibiotic-steroid combination plus an aggressive use of lubricant drops was recommended (Figures 17.5A to D).

Phase 2: Overnight CL corneal molding was initiated 40 days post-ICR procedure. The molding lens induces a temporary change of the shape of the cornea, taking advantage from corneal plasticity, the epithelial layer’s one in particular. While conventional CLs are designed to cause little or no effect on the corneal shape, these lenses are designed to intentionally flatten the cornea in a controlled way, to bring the eye into correct focus to compensate for the refractive error.25,26

While traditional CL designs have secondary and peripheral curves flatter than the central curve of the lens, the lenses utilized for corneal molding have one or more peripheral curves steeper than the optical zone’s curvature (“reverse-geometry CLs”)42-44 (Figures 17.6A and B).

The radius of curvature of the back optical zone is always custom-designed to determine the shape the

Figures 17.6A and B: Wood light fluorescein patterns of oldgeneration conventional RGP CL (A) and modern four-zone reverse-geometry lens (B)

cornea will assume after the molding, thus the amount of refractive error to be corrected (spherical or spherotorical). The lift of peripheral curves over the cornea around the optical zone creates a tear reservoir. In the reverse zone, joining of the optical with the alignment zone, there are one or more curves steeper than the back optical zone. The alignment zone is the bearing zone of the lens; it gives stability to the lens and keeps it centered; its curvature is flatter than the reverse zone, but steeper than the optical zone. The peripheral zone, flatter than the alignment zone, allows the lens edge to lift from the cornea, to achieve an adequate tear turnover under the lens. This tear exchange is necessary to get in new tear liquid to oxygenate the cornea, and to get out the debris and metabolic residuals formed under the lens. The controlled pressure by the edge lift minimizes the risk of corneal insults and helps the CL removal by mean of lid tension.

When the lens is on the eye, the patient can see clearly, like with a conventional fitting. After the sleeping hours and CL removal when the patients wake up, the cornea retains its modified shape for a certain amount of time, and the patient continues to see well, even without the lens. This treatment is reversible and, if the patient stops wearing the lenses completely, the topographic and refractive condition of the eye will regress to the pre-treatment level.38 The overnight use has the obvious advantage of reducing the interference with the environmental factors (dust, wind, conditioned air, sports) that can give trouble during the day; in addition, the pressure of closed lids improves the rapidity of corneal molding. Since the lids are closed during overnight wear and tear circulation behind the lens is reduced by the inactivation of the blink pump, high oxygen permeable materials are

necessary to provide sufficient oxygenation to the 103

MASTERING CORNEAL COLLAGEN CROSS-LINKING TECHNIQUES

Figures 17.7A to C: Slit lamp Wood light ideal fluorescein patterns of a custom designed reverse-geometry lens fitted with the purpose of corneal molding in a virgin keratoconus eye (A), in an eye implanted with a superior INTACS ring segment (B). Side view of case b is shown in (C). Two videos of the latter and another case are available with the link

cornea.39,40 The lens material (siloxy-fluoro- methacrylate Dk 100, Boston XO, hexafocon-A) has shown to induce minimal edematous swelling of the stroma. Moreover, the morning lens removal allows for a rapid recovery,41 as well as proper cleansing and elimination of debris and waste products. The fitting procedure requires a perfect centration that is critical for the efficacy of the mold but not easy to obtain. The movement observed after each blink must be higher than 0.2 mm and lower than 1.0 mm, always inferior to a conventional RGP-CL fitting. The ideal fluorescein pattern shows an image with concentric rings: the dark center (minimal apical clearance, some times minimal touches) corresponds to the bulging conicoid area to be molded; the surrounding green area, a variable thickness tear reservoir (depending on the intended corrective effect, between 30 and 80 microns). A midperipheral dark ring (the alignment zone) with a minimal clearance, sometimes a slight touch and a thin green ring (the edge lift, 80 to 100 micron) follow (Figures 17.7A to C). The transition between the different zones should be blended and smooth. After the first adaptation, there should be no air bubbles, indicating an excessive lift in the tear reservoir zone.

LINK TO THE VIDEO

Dealing with safety of corneal molding, we observed some cases of grade 1 fluorescein staining of the epithelium, which disappeared in the evening, but no significant corneal infiltrates or ulcers or other adverse 104 events. Minimal or no changes were observed in the

central thickness of the cornea, as measured with an ultrasound pachymeter (Allergan Humphrey 850, Carl Zeiss Meditec). Confocal microscopy (Confoscan 3000, NIDEK, Japan) showed no measurable changes in the endothelium, sub-basal nerve plexus or in the anterior, intermediate and deep stroma (overall density and activation of keratocytes were not modified) while the basal layer of the epithelium showed larger and less regular cells after the molding (Figure 17.8). A slight increase in reflectivity of the matrix was observed and can be explained by a mild increase of corneal glycosaminoglycans production, that is a reversible phenomenon probably due to an aspecific reaction of an already altered corneal parenchyma (mild cellular edema due to hypoxia and/or mechanical effects).45-55

To try to explain the biomechanical working mechanism (the negligible flattening observed in the central cornea was counterintuitive), we hypothesize the role of mid-peripheral forces induced by the displacement of the epithelium that results from a proper compression by the CL alignment zone. This hypothesis certainly deserves further confirmation to accurately explain the achieved regularization of both corneal surfaces.

Phase 3 (for Group B only): Corneal Collagen Cross-linking with Riboflavin (C3-R) was performed after 3 months of CL corneal molding. Immediately after CL removal, 30 minutes of Ultraviolet A exposure (5.4 J/cm2 at 370 nm) with the VEGA CBM X-LinkerTM (CSO, Firenze, Italy)63 were applied to the central cornea (after a minimum diameter of 7 mm of epithelial