- •Acknowledgments
- •ANATOMIC CONSIDERATIONS
- •PATIENT MOVEMENT
- •RETROBULBAR HEMORRHAGE
- •TREATMENT AND PREVENTION
- •SUBCONJUNCTIVAL HEMORRHAGE
- •OCULOCARDIAC REFLEX
- •FACIAL NERVE BLOCK
- •CORNEAL EXPOSURE
- •ATONIC PUPIL
- •CONCLUSION
- •2 TOPICAL ANESTHESIA
- •TOPICAL DROP
- •PINPOINT ANESTHESIA (FUKASAKU)
- •TOPICAL GEL ANESTHESIA
- •EYE MOVEMENT
- •VIRTUAL REALITY DEVICE
- •CONJUNCTIVAL BALLOONING
- •INTRACAMERAL TOXICITY
- •TOPICAL TOXICITY
- •PREOPERATIVE EVALUATION
- •CONCLUSION
- •SUTURELESS CATARACT SURGERY
- •THE SCLEROCORNEAL INCISION
- •WOUND CONSTRUCTION PROBLEMS
- •SCLEROCORNEAL (FROWN)
- •CLEAR CORNEA
- •SCLEROCORNEA AND CLEAR CORNEA
- •DESCEMET’S DETACHMENT
- •WOUND BURN
- •WOUND GAPE REPAIR
- •SLIDING FLAP TECHNIQUE
- •PATCH GRAFT TECHNIQUE
- •5 CAPSULORRHEXIS COMPLICATIONS
- •CAPSULAR ANATOMY
- •CAPSULORRHEXIS SIZE
- •CATARACT SIZE AND TYPE
- •IOL OPTIC SIZE
- •ANTERIOR CAPSULAR TEARS
- •NONCONTINUOUS CAPSULORRHEXIS
- •IOL SELECTION
- •ZONULAR DIALYSIS
- •YAG CAPSULOTOMY
- •IRIS STRETCH—TWO INSTRUMENTS
- •SILICONE PUPIL EXPANDER
- •MULTIPLE SPHINCTEROTOMIES
- •IRIS PROLAPSE
- •PHACOEMULSIFICATION
- •IRIDODIALYSIS
- •IRRIGATION AND ASPIRATION
- •ANATOMY
- •HYDRODISSECTION
- •HYDRODELINEATION
- •COMPLICATIONS
- •NONCONTINUOUS CAPSULORRHEXIS
- •CONCLUSION
- •REFERENCES
- •REGIONAL ANESTHESIA
- •FLUID DYNAMICS
- •ETIOLOGY
- •CHOROIDAL VASCULAR FRAGILITY
- •PREVENTIVE MEASURES
- •INTRAOPERATIVE DIAGNOSIS
- •MANAGEMENT OF AISH
- •EXPULSIVE HEMORRHAGE
- •LENS CONSISTENCY
- •REFERENCES
- •HYDRODISSECTION
- •MANUAL DISSECTION
- •12 CHOO CHOO CHOP AND FLIP
- •TECHNIQUE
- •INCOMPLETE CHOPS
- •13 PHACO CHOP
- •CONTRAINDICATIONS
- •MATURE CATARACT
- •CONCLUSION
- •REFERENCES
- •SURGICAL TECHNIQUE
- •COMPLICATIONS
- •INCOMPLETE HYDRODISSECTION
- •CONCLUSION
- •REFERENCES
- •PATIENT EVALUATION
- •VITREOUS MANAGEMENT
- •CONVERSION TO ECCE
- •CONTINUED PHACOEMULSIFICATION
- •CONCLUSION
- •REFERENCES
- •THE INFUSION/ASPIRATION BALANCE
- •CAPSULAR TEARS
- •MAKING A NEW INCISION
- •POSTOPERATIVE CARE
- •LENS MATERIAL AND POSITION
- •CONCLUSION
- •OPERATIVE OCULAR COMPLICATIONS
- •OPERATIVE IOL COMPLICATIONS
- •PHAKIC IOL
- •POSTOPERATIVE IOL COMPLICATIONS
- •IOL REPOSITIONING
- •IOL REMOVAL
- •IOL REPLACEMENT
- •ANATOMIC CONSIDERATIONS
- •PREPARING THE PROXIMAL HAPTIC
- •INSERTION OF THE IOL
- •COMPLICATIONS OF TS PCLs
- •LENS TILT
- •REFERENCES
- •BULLOUS KERATOPATHY
- •STROMAL CORNEAL SCARRING
- •GUTTATALESS FUCHS’
- •COMPLETE DESCEMET’S DETACHMENT
- •POSTOPERATIVE CORNEAL EDEMA
- •BACKGROUND
- •CONCLUSION
- •POSTOCCLUSION SURGE
- •IMMEDIATELY PREOCCLUSION
- •OCCLUSION
- •POSTOCCLUSION
- •ULTRASONIC COMPLICATIONS
- •CONCLUSION
- •RETAINED LENS FRAGMENTS
- •MANAGEMENT OPTIONS
- •POSTOPERATIVE ENDOPHTHALMITIS
- •DELAYED-ONSET ENDOPHTHALMITIS
- •CONCLUSION
- •VISCOCANALOSTOMY PROCEDURE
- •TRABECULECTOMY PROCEDURE
- •IRIS PROLAPSE
- •NPTS–DEEP SCLERAL FLAP
- •DESCEMET’S DETACHMENT
- •HYPOTONOUS MACULOPATHY
- •NPTS
- •CONCLUSION
- •PATIENT SELECTION AND SCHEDULING
- •THE CLANDESTINE WRAPAROUND
- •WHAT’S IMPORTANT NOW
- •SPECIAL MANEUVERS
- •TOPICAL ANESTHESIA
- •INCISION
- •CAPSULORRHEXIS
- •HYDROSTEPS
- •FOLDABLE IOL INSERTION
- •CONCLUSION
- •SMALL PUPILS
Chapter 21
INTRAOCULAR LENS
IMPLANTATION
Harry B. Grabow
Cataract removal by itself and by whatever technique, be it intracapsular, extracapsular, or phacoemulsification, carries with it its own set of complications, which spare no cataract surgeon—regardless of ability or experience. Intraocular lens (IOL) implantation, whether phakic or aphakic, likewise carries with it its own unique set of complications. These complications can occur before, during, or long after implantation; they can result in damage to the eye, the IOL, or both. Surgeons and manufacturers alike, in an effort to minimize the incidence and severity of IOL-related complications, have been studying implantation techniques and IOL behavior since the late 1970s. The method of insertion of an IOL into the eye, and the IOL design, material, and location are all associated with potential complications.
The effect of the location of an IOL inside the eye has been under continuous scrutiny. IOLs have been fixated in the anterior-chamber angle, the anterior iris stroma, the pupil, the posterior-chamber (ciliary sulcus), the lens capsule, and the pars plana. IOL materials have proliferated since the first polymethylmethacrylate (PMMA) IOL was implanted by Harold Ridley1 in 1949. Brought on by the success of smallincision phacoemulsification in the 1970s,2 rigid PMMA lenses have been increasingly supplanted by foldable lenses of silicone, poly-HEMA, acrylic, and biologic collagen.3 Each material behaves differently from the others during and after implantation.
OPERATIVE OCULAR COMPLICATIONS
The introduction of any physical object through an incision into the eye can result in damage to the in-
traocular structures (Table 21–1). If an IOL is forced through an incision that is too small, the incision might enlarge by tearing, with the possible result of an unstable wound, requiring suturing to prevent leakage. Wound leakage is thought to be one cause of postoperative infectious endophthalmitis.
In an attempt to pass the insertion device through the tight incision, excessive posterior angulation may cause inadvertent iridodialysis, with associated hyphema. Similarly, an insertion forceps, or cartridge angled too anteriorally might cause stripping of Descemet’s membrane. The improper wound and chamber dynamics thus created could result in iris prolapse, chamber collapse, corneal endothelial damage, and subsequent postoperative corneal edema.
Improper attention during implantation may traumatize the capsule, resulting in zonulodialysis, tearing of the anterior capsule, tearing of the posterior capsule, and rupture of the anterior hyaloid face, increasing the incidence of postoperative cystoid macular edema (CME) and retinal detachment. With proper attention paid to wound size and construction, chamber maintenance, and careful intraocular manipulation, the incidence of traumatic IOL implantation can be greatly minimized.
OPERATIVE IOL COMPLICATIONS
Just as the ocular tissues may be damaged during IOL implantation, so may the IOL itself (Table 21–2). Damage to an IOL ranges from minor implant forceps scratches on the optic surfaces of a PMMA IOL and scuffing of the surface of acrylic or silicone, to
144
CHAPTER 21 INTRAOCULAR LENS IMPLANTATION • 145
TABLE 21–1 OPERATIVE OCULAR
COMPLICATIONS OF IOL IMPLANTATION
Unstable wound/leakage
Stripped Descemet’s membrane
Corneal endothelial trauma
Iris prolapse
Iridodialysis
Hyphema
Zonulodialysis
Torn anterior capsule
Torn posterior capsule
Rupture anterior hyaloid
major optic fracture or transection in silicone IOLs. An IOL haptic may also be deformed or fractured.
Certain PMMA loop haptics, particularly onepiece designs but also the plate haptics of silicone IOLs, are prone to breaking off during insertion. The fracture of a PMMA loop haptic occurs with excessive flexion of a loop, often during insertion through a tight incision. A lens sustaining such damage becomes unstable. It is mandatory that it be replaced.
Three-piece foldable IOLs may sustain damage to the haptics during implantation. When using forceps the leading or trailing haptic may be caught by the folder and crimped. A bend in the haptic can be gently straightened and the IOL implanted. If it fractures or is broken during the straightening process, it must be removed and replaced. Rarely, when injecting three-piece lenses, if the lens is not positioned properly in the cartridge, the leading haptic may be torn off during implantation. This IOL also must be removed and replaced. The trailing haptic may be crimped by improper plunger positioning. This can usually be straightened, but if severe, or broken, the IOL must be removed and replaced.
Silicone three-piece IOLs that are left in the barrel of the injector for too long will often stick to the plas-
TABLE 21–2 OPERATIVE IOL COMPLICATIONS
Haptic deformation
Haptic fracture
Haptic avulsion
Optic excoriation
Optic deformation
Optic fracture
Asymmetric bag/sulcus implantation
Reversed-optic implantation*
Off-axis implantation**
Posterior IOL dislocation
*Angled haptics, toric, and multifocal IOLs. **Toric IOL.
tic cartridge and tear during insertion. It is therefore important not to load the IOL into the cartridge more than 5 minutes prior to insertion, and not to start the IOL down the barrel until the actual time of intended insertion (Table 21–3). Plate haptic silicone 6.0-mm optic lenses were originally designed to go through cartridges large enough for 4.0-mm scleral incisions. However, they are now going through cartridges tapered to fit through sub–3.0-mm clear-corneal incisions. Subsequent compression and occasional piston override can result in either haptic or optic fracture. If the fracture has completely transected the trailing plate haptic, destabilizing the optic centration, the IOL must be removed and replaced (Fig. 21–1). However, if the fracture involved avulsion of only the corner of a plate or is only partially through a haptic, the lens may be left in situ, as the centration of the IOL will not be affected (Fig. 21–2). A partial fracture of an optic that does not involve the central 3 to 4 mm of the “optical zone” may also be left in place. In these cases, rotation of the peripheral optic fracture to the 12 o’clock position will allow the upper eyelid to cover the peripheral optic aberration. In addition, capsulorrhexis contraction and fibrosis may cover the area (Fig. 21–3), as well as the pupil itself.
TABLE 21–3 COMPLICATIONS OF IOL INJECTORS
Problem |
Cause |
Management |
|
|
|
Torn leading or trailing haptic |
Improper placement in cartridge |
Careful observance of placement guide |
|
Inadequate viscoelastic |
Adequate viscoelastic |
|
Aggressive injector speed |
Inject more slowly |
Crimped trailing haptic |
Plunger damage |
Watch plunger as it contacts posterior IOL, avoid |
|
|
contact with haptic |
Torn IOL |
Improper placement in cartridge |
Careful observance of placement guide |
|
Inadequate viscoelastic |
Adequate viscoelastic |
|
Aggressive injector speed |
Inject more slowly |
|
Too long dwell time |
Do not load IOL into cartridge more than 5 minutes |
|
|
before intended insertion |
|
|
|
146 • COMPLICATIONS IN PHACOEMULSIFICATION
FIGURE 21–1 Silicone plate-haptic intraocular lens (IOL) damage on injection, causing optic fracture or unstable haptic avulsion. (Courtesy of John R. Shepherd.)
PHAKIC IOL
Errors of implantation may also occur without damage to the IOL. Although anterior chamber (AC) IOL implantation is now rarely performed during cataract surgery, it is currently under active investigation for the phakic correction of ametropia. As the pupil is often intentionally miotic for anterior chamber implantation, damage to the iris may occur. Iridodialysis with hyphema can occur both on the proximal side, due to dragging of the subincisional iris while moving the leading haptic toward the pupil, and on the distal side, when attempting to force the trailing haptic of an oversized IOL into the proximal angle. Tucking of the distal iris causes an acute ovaling of the pupil (Fig. 21–4). Excessive manipulation
FIGURE 21–3 Anterior capsular fibrosis over platehaptic silicone IOL.
of an AC IOL may result in chamber collapse with IOL contact with the corneal endothelium.
Phakic and aphakic iris-supported IOL implantation is also currently in its second generation. The Worst-Fechner “lobster-claw” IOL4 (Artisan, Ophtec) (Fig. 21–5) and the version designed by Daljit Singh (Amritsar, India) (Fig. 21–6) are enclaved onto the anterior iris stroma, unlike their first-generation pre- decessors—the Binkhorst “iris-clip” IOL, the Worst “two-loop medallion” IOL, the Copeland “Maltese cross” IOL, the Fyodorov “Sputnik” IOL, and others— which were pupil-supported. The enclavation process of these newer version iris-supported IOLs can result, in the event of phakic implantation, in pressure damage to the lens in back with subsequent development of cataract, or to endothelial damage in both phakic
FIGURE 21–2 Silicone plate-haptic IOL damage on injection, not affecting IOL stability or optical performance. (Courtesy of John R. Shepherd.)
FIGURE 21–4 Progressive postoperative pupillary ovalization with a polymethylmethacrylate (PMMA) anterior chamber (AC) IOL. (Courtesy of J. Alio.)
CHAPTER 21 INTRAOCULAR LENS IMPLANTATION • 147
FIGURE 21–5 Worst-Fechner Artisan (Ophtec) PMMA iris stromal AC IOL. (Courtesy of J. Worst.)
and aphakic implantation if care is not taken to suture or secure the wound before enclavation in order to prevent viscoelastic escape and chamber collapse (assuming that proper stabilization of the IOL was maintained).
POSTERIOR CHAMBER IOL
Implantation of the posterior chamber presumes the presence of an intact or mostly intact zonulocapsular apparatus. The zonule may be complete or incomplete. The capsule may be intact or partially collapsed from sectoral zonulodialysis or torn anteriorly or posteriorly. Just as an AC IOL can tuck the peripheral anterior iris stroma, so can a posterior chamber (PC) IOL tuck the peripheral posterior iris pigmented layer. The haptic, in this case, may push the iris forward at that location, causing sectoral angle closure and peripheral anterior synechia for-
FIGURE 21–6 PMMA iris stromal AC IOL. (Courtesy of D. Singh.)
mation. Chronic chafing of the pigmented layer can result in a transillumination defect and pigment dispersion syndrome. Vigorous implantation of rigid haptics into the ciliary sulcus, particularly those of long overall diameter one-piece PMMA PC IOLs, can result in traumatic zonulodialysis and inadvertent posterior loop location on the pars plana.5,6 Implantation in the posterior chamber in the absence of capsular support requires suturing of loops to the sclera.7,8 Avoiding damage to the ciliary sulcus structures by the blind passage of a needle behind the iris can be facilitated by passing a hollow needle ab externo to guide the intraocular suture needle out through the proper anatomic location9–11 (see Chapter 22).
Implantation of the capsular bag, with either rigid or foldable IOLs, has its own set of potential complications. Unintentional asymmetric bag/sulcus implantation, with one haptic in the capsular bag and one in the ciliary sulcus, may occur, particularly in cases of large capsulorrhexis openings where the CCC is larger than the diameter of the optic, in cases of small pupils with impaired visualization of haptic placement, or in cases of anterior radial tears or canopener capsulotomy.12,13 This may be recognized by inspection at the time of implantation or may not be recognized until a postoperative dilated slit-lamp examination. Early repositioning of the optic into the capsular bag may be performed either in the operating room or at the slit-lamp. However, if not recognized until later, when capsular fibrosis has caused decentration or anterior subluxation of the IOL, then loop-haptic and plate-haptic IOLs must be treated differently.
LOOP HAPTIC IOL
A loop-haptic IOL may simply be dialed out of the fibrosed capsular bag into the ciliary sulcus, provided that significant loop deformity has not occurred. This is usually possible with a one-piece PMMA or three-piece foldable lens with extruded PMMA haptics. However, three-piece IOLs with polypropylene haptics cannot be repositioned, as the haptic has no memory and the permanent deformation of the haptic will interfere with stable IOL positioning. A platehaptic IOL, measuring less than 11.2 mm in overall length, is too short for sulcus fixation. It must be either repositioned into the capsular bag, after reopening with viscoelastic, or, if not possible, then removed and replaced with a PMMA loop-haptic IOL in the sulcus. Opening the capsular bag may be possible months after the original surgery. To do this, viscoelastic should be gently injected through the