Endothelial Keratoplasty:
A Step by Step Guide to
DSEK and DSAEK
Surgery
20
226 |
Corneal Endothelial Transplant |
|
|
Introduction
Endothelial dysfunction from disease or trauma is one of the leading indications for corneal transplantation. Over the past 100 years, the only solution for endothelia’s replacement was through a full thickness corneal transplantation.1 While penetrating keratoplasty (PKP) has been shown to yield healthy donor tissue with good endothelial function, this procedure has been “plagued” by the inherent problems of unpredictable surface topography, retained surface sutures, and poor wound strength.2-6
In 1993 Ko and Feldman presented an animal study at ARVO which described a new technique for endothelial replacement through a scleral limbal incision7 (See also Chapter 14, History of Lamellar and Penetrating Keratoplasty).
Their animal work allowed endothelial replacement, completely avoiding surface corneal incisions, but utilized sutures to attach the graft to the recipient. Gerrit Melles of the Netherlands had the insight to use an air bubble to hold the tissue in place, completely avoiding any sutures or incisions in the recipient cornea. He performed this selective endothelial transplantation in the first human patients in 1998 and called it posterior lamellar keratoplasty8 (See also Chapter 14, History of Lamellar and Penetrating Keratoplasty).Terry and Ousley began laboratory work in 1999 on this technique, and after technical modifications and re-design of instrumentation to make it faster and easier, performed the first United States cases in 2000 and called the surgery Deep Lamellar Endothelial Keratoplasty (DLEK).9-21 All of this work represents a radical departure from the standard PKP technique in that the DLEK surgery accomplished the goal of endothelial replacement without touching the surface of the recipient cornea. By eliminating surface corneal sutures and incisions, the advantages of normal corneal topography and faster wound healing were obtained, leading to faster visual rehabilitation and a more stable globe for the patient.10-14 We have investigated this technique in the largest prospective study of endothelial keratoplasty surgery in the world and have found it to be valid for endothelial replacement surgery.21
While undoubtedly there will be further refinements of the technique and instrumentation in DLEK surgery, it is the purpose of this chapter to describe in detail the recent modification in preparation of the recipient bed by stripping of the recipient Descemet’s membrane (See also Chapter 13, Definition, Terminology and Classification of Lamellar Corneal Surgery). This modification utilizing the stripping of Descemet’s membrane has been popularized as “Descemet’s Stripping Endothelial Keratoplasty”, or
“DSEK”, and has the advantage of being easier for the surgeon to perform and of providing a smoother interface on the recipient side for the visual axis [See also Section 9, Descemet’s Stripping Automated Endothelial Keratoplasty (DSAEK)]. Preparation of the donor tissue in endothelial keratoplasty has also been made easier with the utilization of an automated microkeratome, and the addition of this component to the surgical procedure has been popularized as “Descemet’s Stripping Automated Endothelial Keratoplasty”, or DSAEK. Currently, Moria has the only practical microkeratome for the preparation of donor material and other lamellar keratoplasty procedures (See also Chapter 12, Artificial Anterior Chambers). Recently, the use of the femtosecond laser for donor tissue preparation is also being explored [See also Chapter 26, Femtosecond Laser (Intralase®) – Descemet’s Stripping Endothelial Keratoplasty (Femto-DSEK): Initial Studies of Surgical Technique in Human Eyes]. These advantages of DSEK/DSAEK over DLEK have been mitigated in the past, however, by the reported increase in donor dislocation the day after surgery, requiring a further surgical intervention for re-attachment. In addition, the abnormally increased total corneal thickness following DSEK/DSAEK, has unknown visual consequences for the patient and is still being investigated. We describe in this chapter a method for reducing the incidence of donor dislocation in DSEK/DSAEK surgery, by specific roughening of the peripheral recipient bed to promote donor adhesion. Other surgical maneuvers to prevent dislocation are also described (See also Chapter 27, Techniques to Facilitate Disk Adherence to Recipient Cornea in DSAEK).
The reader is cautioned, however, that DLEK or DSEK/ DSAEK surgery requires a separate skill set from standard full thickness PKP surgery, and the experienced PKP surgeon will find the maneuvers of DLEK or DSEK/DSAEK surgery initially unfamiliar. Therefore it is highly recommended that the new EK surgeon take a hands-on training course in EK surgery with an experienced EK surgeon first, and then follow this, with further cadaver eye practice sessions before embarking in the clinical and surgical treatment of patients.
Anesthesia
DSAEK surgery is usually done under retrobulbar block anesthesia. General anesthesia (either endotracheal or laryngeal mask airway technique) is somewhat easier for DSAEK because it minimizes posterior pressure on the globe and this is important during the recipient resection and donor implantation phases of the surgery. In addition, general anesthesia minimizes the risk of patient movement
Endothelial Keratoplasty: A Step by Step Guide to DSEK and DSAEK Surgery |
227 |
|
|
during the more delicate portions of DSAEK surgery and may aid in the comfort level of the novice DSAEK surgeon. Nonetheless, DSAEK surgery can be safely accomplished with good retrobulbar anesthesia combined with seventh nerve block (orbicularis block) local anesthesia as well. It is even possible to perform DSAEK surgery on selected high risk patients under topical anesthesia, but this is not recommended for the initial cases of the novice DSAEK surgeon.
Preoperative Medications
In the usual case of patients with pseudophakia, the pupil is constricted, in order to stabilize the iris-lens diaphragm during the surgery. This is also done if the patient has a clear crystalline lens and concurrent cataract surgery is not planned. We have stopped using Pilocarpine for this, and instead use Miochol (intraoperatively) in order to only have a short acting constriction of the pupil. The Miochol is placed just after the Healon has been removed from the anterior chamber, after the recipient stripped tissue has been removed.
Preoperatively, one set of aproclonidine 0.5% drops is also given just prior to surgery to reduce pressure and minimize conjunctival injection. Preoperative antibiotics may be given according to the surgeon’s preference. The eye is prepped in the usual sterile ophthalmic fashion with the use of povidone-iodine solution.
In the case of patients with cataract and endothelial failure, cataract surgery is performed concurrently with EK, just prior to the DSAEK endothelial transplant, and the pupil is dilated preoperatively with the surgeon’s standard dilating drops for cataract surgery. While pilocarpine is avoided, the rest of the preoperative medication regimen described above is utilized.
Descemet’s Stripping Automated
Endothelial Keratoplasty
(DSAEK): Recipient Peripheral
Scraping Technique
The essential steps of DSAEK surgery are shown in Figures 20-1A to L. A detailed account of DSAEK surgery maneuvers is presented as follows:
The small incision DSAEK procedure is usually performed from the temporal side in order to provide the greatest manual access and visualization for the surgeon. Prior to forming the DSAEK scleral access incision, two clear corneal limbal stab incisions (about 1 mm diameter)
are placed about 5 clock hours apart, to be used as access points to the anterior chamber later in the operation. We find that an inexpensive 1 mm diamond knife provides a better paracentesis wound than that made by a metal blade. The paracentesis wounds should be made relatively perpendicular to the corneal surface in order to allow quick access to the anterior chamber later in the surgery. Through one of the stab incisions, the cohesive viscoelastic Healon (Pfizer, New York, NY) is placed into the anterior chamber to replace the aqueous fully and to maintain normal pressure. We oppose the use of Viscoat (Alcon, Fort Worth, TX) or other dispersive viscoelastic materials during any portion of DSAEK surgery as the dispersive materials can cause interface coating with subsequent non-adherence and dislocation of the donor corneal tissue.
Prior to the stripping of Descemet’s membrane, a template mark is placed on the corneal epithelial surface. A circular marker with a diameter of 8.0, 8.5, or 9.0 mm (depending upon recipient corneal diameter and surgeon preference) is used to make a circular impression on the central epithelial surface. If the position and centration of the mark is acceptable to the surgeon, then it is accentuated with gentian violet ink marks. This circle on the corneal surface will later be used as a template for stripping of the recipient Descemet’s membrane.
A temporal limbal peritomy of the conjunctiva is performed with scissors allowing exposure of about 6 mm arc length (about 3 clock hours) of limbal tissue. After cautery of the scleral bed, a trifaceted, guarded, diamond knife is then set to a depth of 350 µm and a 5.0 mm length incision is made approximately 1 mm posterior to the corneal limbus and concentric with it. We have found that a deeper initial incision gives less of a beveled wound closure and also a greater chance of early perforation into the anterior chamber during DSAEK surgery. In lieu of a diamond knife, a sharp crescent blade or other steel scalpel can be used for the initial incision. A sharp crescent blade is then utilized to create a deep sclerocorneal lamellar pocket down to about 75 to 85% corneal depth along the entire length of the wound, extending centrally about 1 mm into clear cornea from the limbus.
A simple, blunt tip, reverse Sinskey hook (Bausch and Lomb, St. Louis, MO) is used for the Descemet’s stripping portion of the procedure. The hook is introduced into the Healon-filled anterior chamber through one of the limbal paracentesis sites. The tip is passed across the chamber and then lifted anteriorly until it contacts the recipient endothelium at the distal location of the epithelial circular template mark. The diseased endothelium and thickened Descemet’s membrane of the recipient cornea is easily punctured by the blunt tip of the reverse Sinskey hook and
228 |
Corneal Endothelial Transplant |
|
|
Figures 20-1A to L: (A) The surface of the recipient cornea is marked with a circular template of 8.0 to 9.0 mm diameter, depending on the size of the patient’s cornea; (B) A 5.0 mm scleral incision adjacent to the temporal limbus is made, and a scleral-corneal pocket incision is made into the clear cornea; (C) The anterior chamber is completely filled with Healon, and a blunt tipped Sinskey hook is used to break through and score the recipient Descemet’s membrane, following the path of the overlying circular template; (D) The recipient Descemet’s membrane is stripped from the posterior corneal surface using the same blunt tipped Sinskey hook, while the chamber is maintained with Healon; (E) The Terry Scraper is used to scrape the peripheral recipient bed to create white stromal fibrils that will promote donor tissue edge adhesion; (F) All of the Healon is easily removed from the eye with an irrigation-aspiration tip; (G) The donor tissue is prepared using an automated microkeratome to cut a free anterior cap from the donor tissue, leaving a posterior residual tissue of between 125 µm and 175 µm; (H) The donor posterior disk is punched out using a same diameter trephine, and after a strip of Healon is placed on the central endothelium, the tissue is folded into a 60/40% “taco” shape, to prepare for insertion of this donor disk into the recipient anterior chamber; (I) Charlie insertion forceps are used to grasp the donor tissue and insert it into the recipient anterior chamber; (J) The chamber is deepened with balanced salt solution to begin unfolding the tissue and then the tissue unfolding is completed with placement of an air bubble between the lips of the taco; (K) Once the donor tissue is unfolded and in position, with the chamber filled with air, the Cindy Sweeper is used to remove interface fluid by compressing the surface and “milking” the fluid from the center to the periphery; (L) The air in the anterior chamber is replaced with balanced salt solution, dilating drops are placed on the surface, and a residual air bubble with a diameter that just covers the donor tissue is left in place.
Endothelial Keratoplasty: A Step by Step Guide to DSEK and DSAEK Surgery |
229 |
|
|
the hook then is used to score the recipient Descemet’s membrane, following the path of the overlying circular template mark. This maneuver easily cuts a nearly perfect circle in the Descemet’s membrane, outlining the edge limits of the recipient bed for endothelial transplantation. A blunt tip hook is far preferable to a sharp point or needle point in that it selectively punctures the Descemet’s membrane, but does not penetrate the stronger overlying stromal fibers
(See also Chapter 11, New/Useful Surgical Instruments in DSAEK). This allows true Descemet’s stripping (and not stromal dissection), yielding the easiest stripping and the smoothest possible surface for the visual axis.
Fuchs’ dystrophy causes the recipient Descemet’s membrane to be significantly thicker than what is normally encountered in other conditions of endothelial failure. This fact, in addition to posterior separation of posterior stromal lamellae by edema, works to the advantage of the surgeon in allowing very easy and smooth stripping of the diseased Descemet’s membrane to occur. In addition, the stripped Descemet’s membrane is easily visualized, and does not require special staining to help with resection. Once the diameter of recipient bed has been scored, the same tip is used to gently peel the Descemet’s membrane away from the overlying stromal tissue, pulling the edges 360 degrees into the anterior chamber. The tissue can then be completely stripped off from the central posterior cornea using either the same reverse Sinskey hook tip or by using simple forceps or an irrigation/aspiration tip during the step of viscoelastic removal.
Once Descemet’s membrane has been completely stripped with the reverse Sinskey hook, the diseased tissue can be removed from the anterior chamber and sent to pathology. We utilize a standard cataract surgery diamond blade with a 2.8 mm width to enter the anterior chamber, but any suitable blade is acceptable. Entry into the anterior chamber is done by passing the blade through the corneoscleral tunnel, directing the blade posteriorly, and then entering the anterior chamber. We prefer to enter the anterior chamber at a site at least 1 mm peripheral to the most temporal portion of the circular template mark. Capsular or other gentle forceps are used to grasp the recipient Descemet’s membrane, and remove it from the eye and send it to pathology.
It is at this point of the surgery that we feel it is critical to scrape the periphery of the recipient bed in order to aid in later donor adherence. When viewed by scanning electron microscopy, we have found that the recipient bed after stripping of Descemet’s membrane to be exquisitely, “glassy” smooth.25 Compared to DLEK, there is complete absence of cut stromal fibrils. We believe that these cut fibrils
of the recipient bed significantly contribute to donor adhesion, and their absence after stripping may partially explain why donor tissue after DSAEK has more of a propensity to dislocate than after DLEK. We therefore advocate a hybrid of the two techniques whereby the advantages of both are retained. In this hybrid modification, the periphery of the recipient bed is scraped to roughen the surface and expose stromal fibrils, while the central recipient bed is left untouched to yield the smoothest interface possible for the visual axis.
Peripheral scraping of the recipient bed is accomplished with the use of a specialized instrument, the Terry Scraper (Bausch and Lomb, St. Louis, MO) (See also Chapter 11, New/ Useful Surgical Instruments in DSAEK). This instrument is similar to a reverse Sinskey hook or Descemet’s stripper, but instead has a broad (1 mm) roughened tip like an ice scraper. The tip is introduced into the anterior chamber through the scleral-tunnel incision, with Healon still filling the anterior chamber. The tip of the Terry Scraper is then used to scrape the peripheral 1.5 mm of the recipient bed, and the creation of stromal fibrils is visually verified. The periphery of the recipient bed is scraped for 360 degrees, taking care to leave the central bed of 5 to 6 mm diameter untouched and smooth.
After scraping of the recipient bed, the temporal scleral wound is temporarily closed with 1 interrupted 10-0 nylon suture. An irrigation/aspiration (I/A) tip is then introduced into the anterior chamber and extensive effort is expended to remove all of the viscoelastic from the eye. Absolutely no Healon should remain in the anterior chamber prior to insertion of the donor disc or the donor tissue will not “stick” in place. Therefore, care is taken to irrigate and aspirate the anterior chamber, pupillary area, angle, and even the peripheral recipient bed as necessary. Once the surgeon is confident that all Healon has been removed, then Miochol is injected into the anterior chamber to constrict the pupil. The intraocular pressure of the eye is left slightly soft and attention is turned to preparation of the donor corneal disk.
Automated Donor Tissue
Preparation (DSAEK)
This step of donor preparation can be done just prior to the surgery on the patient’s eye, depending on surgeon preference. “Pre-cut” tissue is also available now through several EBAA certified Eye Banks (See also Chapter 19, Eye Banking and Donor Corneal Tissue Preparation in DSAEK).
The operating microscope is brought over to the separate donor table for preparation of the donor tissue. Because
230 |
Corneal Endothelial Transplant |
|
|
whole globes are rarely available in the United States, an artificial anterior chamber (See also Chapter 12, Artificial Anterior Chambers) is necessary for preparation of the donor corneal disk. The only automated microkeratome system available for DSAEK surgery is from Moria (Moria, Antony, France). The Optisol-GS preservation fluid (Bausch and Lomb, Rochester, NY) from the donor tissue container is aspirated into a syringe (which has a three way stop-cock) and then the syringe is used to fill the I/A port of the artificial anterior chamber with the Optisol-GS fluid. The syringe is also attached to the port to be used to vary the pressure inside the artificial anterior chamber for the duration of the resection. The standard donor corneoscleral cap tissue is first coated with a thin layer of Healon on the endothelium. It is then placed endothelial side down onto the post/piston of the artificial anterior chamber (taking care not to include an air bubble in the chamber) and the tissue is oriented with the largest diameter of the cornea in the horizontal meridian. With the donor corneal tissue within the artificial anterior chamber, the piston/post of the unit is then raised until the tissue is firmly locked into place. The Optisol filled syringe is then used to raise the pressure within the artificial anterior chamber to over 65 mmHg and the stopcock is closed to stabilize the high pressure. The epithelial cells are then wiped from the surface of the cornea with a Miracel sponge. The horizontal meridian is marked at the peripheral cornea with a marking pen so that the horizontal meridian of the donor tissue can be identified and for proper anterior cap orientation later in the procedure.
For anterior automated lamellar keratoplasty, the guide ring for the microkeratome can be adjusted in height to yield the desired diameter for the tissue resection. For DSAEK surgery, the greatest diameter possible of at least 10 mm is required, and therefore the guide ring should be placed at the lowest possible position without the use of a spacer.
A 300 µm microkeratome head is used and the diameter of resection is at least 9.5 mm or more. For corneas that are thicker than 580 microns, a 350 µm microkeratome head can be utilized to obtain an even thinner posterior donor tissue. Caution should be utilized, however, when using a 350 µm head in order to avoid the occurrence of posterior perforation or “button holes” of the tissue (Editorial Note: When using a 350 µm head, pachymetry of the donor cornea is recommended). With the pressure in the artificial anterior chamber elevated to at least 65 mmHg and verified with a gravity tonometer or by digital palpation, the microkeratome head is mounted on the guide ring, positioned for resection, and then passed over the donor cornea at a rate of about 4 to 5 seconds for the pass.
A free cap of anterior tissue is resected and remains above the blade on the microkeratome head. After drying the residual stromal bed with Miracel sponge, checking the stromal bed for smoothness of cut and diameter of cut, several marks are placed at the peripheral edge of the resected bed to help with the centering of the subsequent trephination of the donor tissue. The anterior cap is placed back in position, using the previously placed peripheral reference surface marks. One additional mark is then placed at the exact central point of the anterior cap of tissue to further facilitate centration of the posterior trephination. A moment is given for the anterior cap to adhere to the bed.
The donor tissue should then be carefully dismounted from the artificial anterior chamber without damaging the endothelial cells from chamber collapse. We have found that the easiest way to avoid chamber collapse is to leave the tissue attached to the post/piston. To achieve this, the stopcock on the syringe is turned to the position to allow Optisol flow from the syringe to the chamber. A tying forceps is then used to sweep along the inside ring of the metal cap which locks the tissue onto the post, pushing slightly posterior on the scleral rim, and breaking the seal that binds the donor scleral tissue to the metal cap. Very gently the post/piston is lowered, and Optisol is gently infused, as needed, to keep the donor chamber from collapsing. The locking cap is then removed, with the donor tissue left on the post with a formed chamber. The scleral edges of the donor corneal button are gently lifted in each quadrant to release the seal of the tissue to the post, and the tissue is removed from the post very slowly, lifting the scleral edge up to allow air to enter the chamber, and as the tissue is further lifted off, the air slowly pushes the Healon along, and the Healon then simply flows off the opposite scleral edge as one single sheet, from the endothelial layer onto the post. Once again, care is taken not to collapse the chamber and damage the endothelium. We believe that minimal irrigation of the endothelium with Optisol during tissue removal from the Moria unit aids in the health of the endothelium and in the subsequent donor adherence to the recipient bed.
Once the donor corneoscleral tissue has been removed from the post, we have been gently irrigating the sclera above and below the endothelial surface of the donor tissue with Optisol solution (taken from the same transport container for the donor tissue) in order to remove any excess residual Healon from the donor. We then use a Miracel sponge to wick the excess fluid from the endothelium, placing the sponge tip at the scleral edge, away from the endothelium.
Endothelial Keratoplasty: A Step by Step Guide to DSEK and DSAEK Surgery |
231 |
|
|
The donor tissue is then placed endothelial side up onto a standard punch trephine block. The previously placed ink mark on the central point of the anterior resected cap is used as a guide to position the tissue for trephination, in order to make sure that the posterior punch trephination is centered on the bed of the previous keratome pass. We utilized a Barron donor punch (Katena, Denville, NJ). The same size diameter punch is used as the diameter of the Descemet’s membrane disc that was removed from the recipient. The tissue is punched out with the trephine.
Because the 5 mm wound of small incision DSEK surgery is smaller than the 8.0 mm (or larger) diameter of the donor disc, the donor tissue must be folded prior to insertion into the recipient anterior chamber. To accomplish this, a very thin strip of Healon is placed onto the endothelial surface along the previously identified and marked horizontal meridian of the donor button. Stabilizing the anterior edge of the donor button with a 0.12 mm forceps, the posterior stromal tissue edge is gently grasped with non-toothed delicate forceps such as Utrata forceps. The posterior tissue is then gently folded with the endothelium on the inside protected by the layer of Healon, and it is folded into an asymmetric “taco” shape, in a 60%/40% ratio, the most anterior side of the taco being 60% and the posterior side 40%. We were the first to initiate the idea of an “overfolded, 60%/40% ratio” in order to avoid having the tissue unfold upside-down in the patients anterior chamber. The donor tissue is then brought over to the operative field still on the trephine block.
Donor Tissue Preparation Using
Pre-Cut Tissue
When utilizing tissue that has been pre-cut by the eye bank
(See also Chapter 30, Use of Eye Bank Pre-cut Donor Tissue in DSAEK) with a microkeratome or femtosecond laser and then shipped to the surgery center, the surgeon must be very careful to insure that he knows the exact diameter of the resected bed and that he personally marks the edges of the resected bed of the donor tissue. In this way, the surgeon can avoid an eccentric cut that goes outside of the microkeratome cut bed, with the attendant 1 mm thick donor edge.
Using pre-cut tissue is very easy and fast, but to avoid complications, attention to details is paramount. The precut tissue is removed from the Optisol container and placed endothelial side down onto the lint-free plastic or metal surface of the donor table. Because the donor sclerocorneal tissue has a 3 mm rim of scleral “skirt” and tends to maintain its convex configuration, this manipulation of the tissue
will not collapse the tissue or risk damage to the endothelium. Very gently, the surgeon dries the epithelial surface of the peripheral donor cornea with a Miracel sponge and reveals the edges of the microkeratome cut bed. Although the Eye Bank places marks on the donor cornea, these are often smudged, difficult to see, and may not be accurate to the level of precision to avoid an eccentric cut. After drying, these edges are then measured by the surgeon for the diameter and marked with an ink pen so that they are distinctly seen. The central free cap (which was left in place by the Eye Bank prior to shipment) can also be dried and marked centrally. The surgeon then takes the tissue and places it endothelial side up onto the trephine block, using the marks that he personally placed, to determine the best centration on the block, prior to trephination. The trephination and other steps that follow are well described above.
One interesting feature of using pre-cut tissue is that when folding the tissue into the 60/40 taco configuration, the adherence between the posterior stroma and the overlying free cap can sometimes seem a lot stronger than the tissue that is cut “on site” and so care should be taken to avoid causing stretching or striae when folding the graft prior to insertion into the patient’s anterior chamber.
Donor Tissue Preparation
Without a Microkeratome:
The “DSEK” Procedure
The operating microscope is brought over to the separate donor table for preparation of the donor tissue. Because whole globes are rarely available here in the United States, an artificial anterior chamber (See also Chapter 12, Artificial Anterior Chambers) is necessary for preparation of the donor posterior disc. We utilized a Bausch and Lomb (St. Louis, MO) artificial anterior chamber that is all stainless steel and has dual I/A ports. The Optisol-GS preservation fluid (Bausch and Lomb, Rochester, NY) from the donor tissue container is aspirated in a syringe and is then used to fill the I/A ports of the artificial anterior chamber. The syringe is also attached to the port to be used to vary the pressure inside the chamber for the duration of the resection. The standard donor corneoscleral cap tissue is first coated with a layer of Healon on the endothelium. It is then placed endothelial side down onto the post of the artificial anterior chamber and oriented with the largest diameter of the cornea in the horizontal meridian. This meridian is marked with a marking pen so that the horizontal meridian of the donor tissue can be identified later in the procedure. The donor tissue is capped into place and the chamber is filled
232 |
Corneal Endothelial Transplant |
|
|
with Optisol-GS and the pressure normalized. There are several ways to create a deep dissection plane in the donor corneal tissue in the absence of a microkeratome. Each surgical approach has advantages and surgeon preference is the over-riding determinant as to which method is to be utilized. The peripheral incision and central manual trephine approachs are described below.
In the peripheral incision technique, the preparation of the donor is similar to the preparation of the recipient deep lamellar plane. A diamond knife set to a depth of 350 µm is used to make a 3 or 4 clock hour-length incision in the peripheral donor limbal area, right next to the edge of the metal cap of the artificial anterior chamber. The crescent blade is then used to cut to the deeper stromal tissue and then once the desired plane has been reached, the Devers Dissectors (Bausch and Lomb, St. Louis, MO) are used to continue the dissection plane all the way to the limbus of the donor tissue for 360°. We have found it helpful to place multiple ink marks onto the surface of the donor tissue. These marks accentuate the visualization of the surface of the donor tissue and therefore allow better depth perception (and estimation of the level of the dissection) when viewing the Devers Dissectors plane compared to the surface plane. It is important to make sure that the dissection plane is carried out all the way to the limbus in every quadrant in order to avoid problems that may result from an eccentric trephination of the donor lenticule later on.
In the manual trephine approach, an 8.5 mm diameter Barron suction recipient trephine (Katena Products, Denville, NJ) is placed onto the surface of the donor tissue and suction is applied. Trephination is carried out to about 60% depth with the trephine. It is noteworthy that after the blade touches the epithelial surface of the donor, it only takes about 4 or 5 quarter turns of the Barron trephine to reach this depth. This is much sooner than when the same trephine is used on the recipient in standard PKP surgery. The trephine is then removed and the cut inspected for depth. Ideally, an 80% depth should be attained for the plane of the pocket of the donor tissue. Any deeper than this, and the donor tissue is so thin that it spontaneously rolls up like a rug causing confusion as to which side is the endothelial side and undoubtedly causing endothelial damage. If the dissection depth of the donor is less than 60%, then the stromal surface may not be as smooth and the tissue may be much thicker. Whether increased disk thickness causes a later visual problem is unknown at this time, but separate reports by Terry and by Price on this issue at recent ASCRS and ARVO annual meetings suggest that donor thickness is not a factor in final visual results.
Transplantation of the Donor
Tissue
With the microscope in place, the temporary scleral suture of the superior wound is cut. The anterior chamber of the patient is then filled completely with BSS. The donor tissue is then brought into the field and grasped along the horizontal meridian of the stromal surface of the donor tissue with specialized insertion forceps (Charlie Forceps, Bausch and Lomb, St. Louis, MO). The Charlie forceps are non-toothed fine forceps that coapt only at the distal tips. The forceps have a block that allows a significant spacing along the blade length to prevent crushing of the donor corneal tissue. This specially designed stop in the Charlie forceps enables the surgeon to transfer and hold the folded donor disc tissue without crushing it. The folded donor tissue is placed into the anterior chamber in one deft movement, by inserting the donor tissue with the anterior 60% stromal side facing the recipient bed and the posterior 40% stromal side facing the iris. Again, the endothelial layer remains protected on the inside by Healon. The tissue can be gently manipulated with the forceps along the stromal sides if centration of the tissue within the recipient bed needs to be improved. Additionally, the surface of the cornea can be massaged, and this too often allows the donor taco tissue to be gently adjusted into proper centration. The opening of the taco is placed to the surgeon’s left. The 60% stromal side gently adheres to the overlying recipient bed with the 40% stromal edge lying nearly perpendicular to the iris plane.
Three sutures of 10-0 nylon are then used to close the scleral wound to secure the chamber. A cannula is then placed through the right hand stab incision and the tip placed onto the iris surface. BSS is then gently injected into the anterior chamber to fill the chamber and deepen it. With deepening of the anterior chamber, the “taco” will usually begin to open. The ideal position is to open the taco just enough so that the posterior 40% edge lies at an 80 degree angle, just short of being perpendicular to the iris plane. If the tissue does not open at all, then the irrigating cannula can be moved to the left paracentesis site, and irrigation with BSS can be used to loosen the Healon from the endothelial surface and gently unfold the tissue to the 80 degree angle noted above. Because the donor tissue was folded into an asymmetric shape, the tissue invariably will spontaneously unfold in the correct orientation (i.e. endothelium down), as long as the chamber is deep enough and there is no impediment to the unfolding of the donor corneal disc. Once the tissue has unfolded to the 80 degree angle, then an air bubble is gently injected into the anterior
Endothelial Keratoplasty: A Step by Step Guide to DSEK and DSAEK Surgery |
233 |
|
|
chamber from the left paracentesis site, very gently into the interior of the 80 degree folded taco. This gentle injection will then fully open the taco and push it up into position onto the recipient bed. Once the tissue is unfolded fully, then air is forcibly and quickly injected to fill the anterior chamber and stabilize the donor tissue, locking it into position. If at any time the surgeon has trouble opening or positioning the donor taco, then the first thing to do is to close the wound with three sutures to stabilize the anterior chamber and then repeat the unfolding and chamber deepening maneuvers mentioned above.
The donor disc may not have perfect centration after insertion. If not, it can be positioned from either the endothelial side or the stromal side. A reverse Sinskey hook (Bausch and Lomb, St. Louis, MO) is used for endothelialside positioning. The hook is placed through the stab incision, the peripheral endothelium is engaged, and the tissue moved over to whatever position is desired to achieve optimal centration of the donor corneal disc. This should only be done with a partial air bubble in the anterior chamber. If the chamber is completely filled with air, then such a maneuver will cause striae in the donor tissue. Although this maneuver undoubtedly causes endothelial damage at that point of peripheral contact, we have not found that the central endothelial cell counts 6 months after surgery are any worse than that after a standard PKP procedure.10,11,14,21 Care is taken, however, to minimize this maneuver and also to avoid the central posterior striae that can occur and can compromise vision. An alternative technique for positioning can be done from the stromal interface side using a 30-gauge needle tip. A slight “barb” is placed on a standard short 30-gauge needle, and the tip is placed through the temporal wound directly into the donor-recipient interface. The barb is rotated posteriorly to engage a few stromal fibers of the donor disc, and this grasp is used to move the tissue over into the proper position of centration. During both the endothelial and stromal positioning maneuvers, the anterior chamber is only partially filled with air, namely, an air bubble with a diameter of 9 mm or less. Once the tissue is properly centered, the anterior chamber is completely filled with air and the wound is sutured. If the two paracentesis sites are not air tight, then these too can be temporarily sutured shut for the next step of the procedure.
Once the tissue is in proper centration, it is critical to make sure that there is no residual fluid in the central or peripheral interface which can interfere or delay adhesion of the donor disc to the recipient cornea. One technique described by Price et al involves the “milking” of interface fluid from the central interface to the periphery and into
the anterior chamber (See also Chapter 27, Techniques to Facilitate Disk Adherence to Recipient Cornea in DSAEK). In this technique, the anterior chamber must be completely filled with air, past the edges of the donor tissue. The epithelial surface of the cornea is kept wet with BSS, and then the smooth surface of the shaft of an irrigating cannula is used to deeply compress the central surface of the cornea. The cannula is then swept across the surface from central to peripheral, stroking the corneal surface, attempting to move central interface fluid to the periphery and then into the anterior chamber. Significant compression of the surface must be employed. This maneuver is done from center to periphery in every quadrant, until the surgeon is satisfied that there is no residual fluid in the interface. An instrument called the Cindy Sweeper (Bausch and Lomb Surgical, St. Louis, Missouri) can be for this maneuver (See also Chapter 11, New/Useful Surgical Instruments in DSAEK).
Another maneuver for interface fluid removal involves the placement of stab incisions from the surface to the interface, which are placed in the mid-peripheral cornea in each quadrant. Price has advocated these stab incisions
(See also Chapter 27, Techniques to Facilitate Disk Adherence to Recipient Cornea in DSAEK) as a means of further releasing interface fluid and reducing donor dislocations. We do not advocate this technique at this time as it violates the primary philosophy of endothelial keratoplasty, which is to avoid surface corneal incisions or sutures of any kind. Furthermore, we do not find that this additional manipulation offers any further protection against dislocation than the recipient preparation steps we have outlined above.
With the tissue in good position, the interface fluid removed, and the anterior chamber completely filled with air, the microscope light is turned off and the tissue is left undisturbed for a full ten minutes intraoperatively. We believe that this time allows for the donor corneal tissue to fully warm-up to the patient’s body temperature and for the donor corneal endothelial pump function to begin. This also allows for the cohesive interaction of the peripheral recipient corneal stroma with the donor corneostromal fibrils. Admittedly, the decision for 10 minutes of intraoperative waiting time to facilitate donor disc adhesion to the patient’s cornea is arbitrary, and less or more time may be recommended in the future as multiple surgeons experience dictate.
It is also at the beginning of this 10 minute waiting time that we place several drops of dilating solution (Cyclogyle 1% and Phenylephrine 2.5%) onto the corneal surface to allow for the pupil to dilate postoperatively. Because we leave about an 8 or 9 mm air bubble in place at the end of
234 |
Corneal Endothelial Transplant |
|
|
surgery, the dilated pupil will prevent any pupillary block. In nearly 500 cases of endothelial keratoplasty, we have not had a single case of pupillary block.
Once satisfied that the donor disc is in final position with no interface fluid, the surgeon then removes the air in the anterior chamber and replaces it with BSS. Care is taken to avoid pupillary block by the air bubble in the anterior chamber, but if it occurs, simple suctioning of the air from the pupillary area resolves the problem. Occasionally air can get trapped behind the iris, giving the impression of posterior pressure with the iris coming forward to the donor edges. Again, suctioning with a cannula from the pupillary area will resolve this issue. The BSS placed into the anterior chamber creates a normal IOP and the chamber deepens. An air bubble of approximately 8 to 9 mm is usually left in place to help further stabilize the donor disc position over the first 24 hours postoperatively.
The suture knots of the scleral incision are cut short, and buried on the scleral side. The wound is checked to be watertight. The conjunctival peritomy is closed with either sutures or cautery. We routinely place on the corneal surface a 24-hour collagen shield soaked in antibiotics (moxifloxacin) and steroids (dexamethazone) at the close of surgery in order to deliver medication until the patch is removed the next day; however, each surgeon’s usual routine for antibiotics (subconjunctival or otherwise) is certainly acceptable.
A gentle occlusive patch and shield are routinely taped into place, and the patient is brought to the recovery room. We usually instruct the nurses to have the patient lie in a supine position, flat, facing the ceiling, for the first hour after surgery and then as much as possible to allow the retained air bubble to further stabilize the graft position, but this is not critical. The patient is discharged following this outpatient procedure when fully recovered from the anesthesia.
Combined Surgery with DSAEK
The most common procedure done in combination with DSAEK surgery is cataract extraction with intraocular lens placement. This is usually accomplished with phacoemulsification, but other nucleus manipulative techniques can be employed. The cataract extraction phase of the combined procedure is usually done first and from the same surgical sclerocorneal tunnel incision site. If there is a problem with visualization of the procedure due to surface bullae, nodular scarring or epithelial edema, we simply scrape the surface of the cornea over a 7 mm diameter area or larger and remove any irregularities. Even with poor visualization, the nucleus can be easily removed by bringing the lens up into
the anterior chamber and performing the emulsification there. Damage to the central endothelium is not an issue, because the endothelium will be removed during the DSEK procedure which follows. The viscoelastic material used must be the most cohesive type available, therefore we prefer Healon or Healon V (Pfizer, New York, NY) for use during any surgery that is combined with DSEK. By no means should a dispersive viscoelastic like Viscoat (Alcon, Fort Worth, TX) be used at any time of a combined procedure, and a concentrated effort must be made to ensure that absolutely no viscoelastic of any kind remains in the eye prior to insertion of the donor tissue lenticule. After the cataract extraction with IOL placement is completed, the surgeon then strips the Descemet’s membrane as described above using either the paracentesis sites or the scleral tunnel incision for access (Editorial Note: Removal of the recipient Descemet’s membrane can be performed either before or after the phacoemulsification depending upon surgeon preference. Also, phacoemulsification through a cloudy cornea can also be performed by a technique described by Dr. Thomas John namely, “upside-down phacoemulsification”).
Other surgeries such as IOL exchange, vitrectomy, iridoplasty, or suturing of an IOL to the ciliary sulcus can also be accomplished at the same time as DSEK surgery. Because many of these surgeries require a larger incision, namely, larger than a 3 mm cataract wound, they can be carried out through the DSAEK wound, and the DSAEK wound fashioned for whatever length that is necessary to accomplish the task (Editorial Note: When using a much larger incision, the surgeon may consider the superior limbus area rather than the temporal location of the surgical wound).
All surgical maneuvers must be completed however, before the donor tissue is inserted, to insure the secure adhesion and safety of the donor endothelium. Interestingly, many intraocular surgeries can safely be accomplished only 3 or 4 months after endothelial keratoplasty surgery without concern of dislodging the grafted corneal endothelial tissue.22
Postoperative Course
The patient is seen the next morning and the patch is removed. Most patients will remark that the eye was as comfortable as after standard cataract surgery and that they did not require any narcotic pain relief following the surgery. Once the patch is removed, the vision is usually about 20/200. The vision is unimportant on postoperative day one, and the only reason for the visit is to insure that the donor corneal disc is attached to the recipient cornea, and that it is in good position. In our prospective series of our first 100 DLEK patients, we experienced only 4 cases