- •Advance Information
- •Figure 1 MC68175 Functional Block Diagram
- •Table of Contents
- •Features
- •Additional Support
- •Documentation
- •Features
- •Signal/Connection Descriptions
- •Signal Groupings
- •Power Input and Monitoring
- •Processor Clock
- •Test and Reset
- •Input
- •Output
- •Input
- •Input
- •Input
- •Current Symbol Inputs
- •Input
- •Input
- •Serial Peripheral Interface (SPI)
- •Receiver Control Port
- •Specifications
- •Introduction
- •Maximum Ratings
- •TSTG
- •Thermal characteristics
- •Not available
- •DC Electrical Characteristics
- •ITSI
- •AC Electrical Characteristics
- •Initialization Timing
- •tSTART
- •tRESET
- •tRHRL
- •tOWRL
- •RESET Timing
- •tRLRH
- •tRHRL
- •Serial Peripheral Interface (SPI) Timing
- •tCYC
- •tLEAD1
- •tLAG1
- •tRDY
- •tRDY
- •tLEAD2
- •tLAG2
- •tDIS
- •tSSH
- •tSCKH
- •tSCKL
- •Packaging
- •Pin-out and Package Information
- •TQFP Package Description
- •TOUT0
- •TOUT3
- •TOUT2
- •TOUT1
- •TOUTEN
- •LOBAT
- •READY
- •EXTS1
- •TEST
- •EXTS0
- •XTAL
- •EXTAL
- •SYMCLK
- •MOSI
- •MISO
- •TOUTSEL
- •RESET
- •CLKOUT
- •CLKOUT
- •RESET
- •TOUT3
- •EXTAL
- •TOUTEN
- •EXTS0
- •TOUTSEL
- •EXTS1
- •SYMCLK
- •LOBAT
- •TEST
- •MISO
- •TOUT0
- •MOSI
- •TOUT1
- •READY
- •TOUT2
- •XTAL
- •Ordering Drawings
- •Design Considerations
- •Thermal Design Considerations
- •Application Design Considerations
- •Ordering Information
- •FLEX Overview
- •FLEX Signal Structure
- •FLEX Message Word Definitions
- •Numeric Data Message
- •Message Fill Rules
- •Special Format Numeric
- •Hex/Binary Message
- •Message Content
- •Fragment Termination
- •Message Header
- •Alphanumeric Message
- •Message Content
- •Message Termination
- •Enhanced Fragmentation Rules
- •Secure Message
- •Message Content
- •Message Termination
- •FLEX Encoding and Decoding Rules
- •FLEX Encoding Rules
- •FLEX Decoding Rules
- •FLEX Character Sets and Rules
- •Alphanumeric Character Set
- •Numeric Character Set
- •Spare
- •Space
- •Space
- •FLEX Local Time And Date
- •Month/Day/Year
- •Second/Minute/Hour
- •Accurate Seconds/Daylight Savings Time/Time Zone
- •RESERVED
- •FLEX CAPCODES
- •Idle Word (Illegal Address)
- •Long Address 1
- •Short Address
- •Long Address 3
- •Long Address 4
- •Short Address (Reserved)
- •Info Service Address
- •Network Address
- •Temporary Address
- •Operator Messaging Address
- •Short Address (Reserved)
- •Long Address 2
- •1F7FFF–1FFFFE
- •Idle Word (Illegal Address)
- •1FFFFF
- •Long Address 1
- •Long Address 2
- •Long Address 1
- •Long Address 3
- •Long Address 1
- •Long Address 4
- •Long Address 2
- •Long Address 3
- •Long Address 2
- •Long Address 4
- •CAPCODE Type
- •fffbU1234567
- •fffbU123456789
- •RfffbU1234567890
- •Standard Frame and Phase Embedding Rules
- •CAPCODE Alpha Character Definition
- •CAPCODE to Binary Conversion
- •Short CAPCODE
- •Long CAPCODE 2,101,249 to 1,075,843,072
- •Long CAPCODE 1,075,843,073 to 3,223,326,720
- •Long CAPCODE 3,223,326,721 to 4,297,068,542
- •Binary to CAPCODE Conversion
- •CAPCODE Assignments
- •SPI Packets
- •Packet Communication Initiated by the Host
- •Packet Communication Initiated by the FLEXchip IC
- •1. The FLEXchip IC drives the READY pin low.
- •Host-to-Decoder Packet Map
- •Decoder-to-Host Packet Map
- •Host-to-Decoder Packet Descriptions
- •Checksum Packet
- •Configuration Packet
- •Oscillator Frequency Difference (OFD)
- •Signal Polarity (SP)
- •Normal
- •Normal
- •Normal
- •Inverted
- •Inverted
- •Normal
- •Inverted
- •Inverted
- •Synchronous Mode Enable (SME)
- •Maximum Off Time (MOT)
- •Clock Output Disable (COD)
- •Minute Timer Enable (MTE)
- •Low Battery Polarity (LBP)
- •Control Packet
- •Force Frame (FF) 0–7
- •Single Phase Mode (SPM)
- •Phase Select (PS)
- •Send Block Information (SBI) words 2-4
- •Minute Timer Clear (MTC)
- •Turn On Decoder (ON)
- •All Frame Mode Packet
- •Decrement All Frame (DAF) Counter
- •Force All Frame (FAF) Mode
- •Decrement Temporary Address (DTA) Enable Counter
- •Receiver Line Control Packet
- •Force Receiver Setting (FRS)
- •Control Line Setting (CLS)
- •Receiver Control Configuration Packets
- •Low Battery Check (LBC)
- •Control Line Setting (CLS)
- •Step Time (ST)
- •Receiver Warm Up Setting Packets
- •Setting Number (s)
- •Warm Up 1
- •Warm Up 2
- •Warm Up 3
- •Warm Up 4
- •Warm Up 5
- •Step Enable (SE)
- •Low Battery Check (LBC)
- •Control Line Setting (CLS)
- •Step Time (ST)
- •3200 sps Sync Setting Packets
- •Low Battery Check (LBC)
- •Control Line Setting (CLS)
- •Step Time (ST)
- •Receiver On Setting Packets
- •Setting Number (s)
- •1600 sps Sync
- •3200 sps Data
- •1600 sps Data
- •Low Battery Check (LBC)
- •Control Line Setting (CLS)
- •Receiver Shut Down Setting Packets
- •Setting Number (s)
- •Shut Down 1
- •Shut Down 2
- •Step Enable (SE)
- •Low Battery Check (LBC)
- •Control Line Setting (CLS)
- •Step Time (ST)
- •Frame Assignment Packets
- •Frame range (f)
- •Frame 127
- •Frame 112
- •Frame 111
- •Frame 96
- •Frame 95
- •Frame 80
- •Frame 79
- •Frame 64
- •Frame 63
- •Frame 48
- •Frame 47
- •Frame 32
- •Frame 31
- •Frame 16
- •Frame 15
- •Frame 0
- •Assigned Frame (AF)
- •User Address Enable Packet
- •User Address Assignment Packets
- •User Address Word Number (a0–a3)
- •Long Address (LA)
- •Tone-Only Address (TOA)
- •Address word (A0–A20)
- •Decoder-to-Host Packet Descriptions
- •Block Information Word Packet
- •Address Packet
- •Priority Address (PA)
- •Phase (p)
- •Long Address type (LA)
- •Address Index (AI)
- •Tone Only Address (TOA)
- •Word number (WN) of vector (2–87)
- •Unused bits (x)
- •Vector Packet
- •Short Message / Tone Only Vector
- •Numeric Vector Packet
- •Vector Type Identifier (V)
- •Additional Bit Descriptors
- •Vector Type Identifier (V)
- •Secure
- •Alphanumeric
- •Hex / Binary
- •Additional Bit Descriptors
- •Short Instruction Vector
- •Message Packet
- •Status Packet
- •Frame Info Valid (FIV)
- •Current frame number (f)
- •Synchronous Mode (SM)
- •Low Battery (LB)
- •Current System Cycle Number (c)
- •Synchronous Mode Update (SMU)
- •Low Battery Update (LBU)
- •Minute Time-out (MT)
- •End Of Frame (EOF)
- •Buffer Overflow Error (BOE)
- •Unused bits (x)
- •Part ID Packet
- •Model (MDL)
- •Compatibility ID (CID)
- •Revision (REV)
- •Application Notes
- •Receiver Control
- •Introduction
- •1. what setting is applied to the control lines,
- •2. how long to apply the setting, and
- •Receiver Settings at Reset
- •Normal Receiver Warm Up Sequence
- •First Receiver Warm Up Sequence
- •Receiver Shut Down Sequence
- •Miscellaneous Receiver States
- •Low Battery Detection
- •Message Building
- •ADDRESS 1
- •ADDRESS 2
- •LONG ADDRESS 3 WORD 1
- •LONG ADDRESS 3 WORD 2
- •VECTOR 1
- •VECTOR 2
- •MESSAGE 1, 1
- •MESSAGE 1, 2
- •VECTOR 3
- •MESSAGE 1, 3
- •MESSAGE 3, 1
- •MESSAGE 2, 1
- •MESSAGE 2, 2
- •MESSAGE 2, 3
- •MESSAGE 3, 2
- •MESSAGE 2, 4
- •MESSAGE 3, 3
- •ADDRESS
- •ADDRESS
- •VECTOR
- •VECTOR
- •MESSAGE
- •MESSAGE
- •MESSAGE
- •MESSAGE
- •MESSAGE
- •MESSAGE
- •MESSAGE
- •VECTOR
- •MESSAGE
- •MESSAGE
- •MESSAGE
- •Building a Fragmented Message
- •ADDRESS 1
- •VECTOR 1
- •MESSAGE
- •ADDRESS 1
- •VECTOR 1
- •MESSAGE
- •STATUS
- •ADDRESS 1
- •VECTOR 1
- •MESSAGE
- •STATUS
- •ADDRESS 1
- •VECTOR 1
- •MESSAGE
- •Operation of a Temporary Address
- •Group Messaging
- •FLEX Overview
- •FLEX Signal Structure
- •FLEX Message Word Definitions
- •Numeric Data Message
- •Message Fill Rules
- •Special Format Numeric
- •Hex/Binary Message
- •Message Content
- •Fragment Termination
- •Message Header
- •Alphanumeric Message
- •Message Content
- •Message Termination
- •Enhanced Fragmentation Rules
- •Secure Message
- •Message Content
- •Message Termination
- •FLEX Encoding and Decoding Rules
- •FLEX Encoding Rules
- •FLEX Decoding Rules
- •FLEX Character Sets and Rules
- •Alphanumeric Character Set
- •Numeric Character Set
- •Spare
- •Space
- •Space
- •FLEX Local Time And Date
- •Month/Day/Year
- •Second/Minute/Hour
- •Accurate Seconds/Daylight Savings Time/Time Zone
- •RESERVED
- •FLEX CAPCODES
- •Idle Word (Illegal Address)
- •Long Address 1
- •Short Address
- •Long Address 3
- •Long Address 4
- •Short Address (Reserved)
- •Info Service Address
- •Network Address
- •Temporary Address
- •Operator Messaging Address
- •Short Address (Reserved)
- •Long Address 2
- •1F7FFF–1FFFFE
- •Idle Word (Illegal Address)
- •1FFFFF
- •Long Address 1
- •Long Address 2
- •Long Address 1
- •Long Address 3
- •Long Address 1
- •Long Address 4
- •Long Address 2
- •Long Address 3
- •Long Address 2
- •Long Address 4
- •CAPCODE Type
- •fffbU1234567
- •fffbU123456789
- •RfffbU1234567890
- •Standard Frame and Phase Embedding Rules
- •CAPCODE Alpha Character Definition
- •CAPCODE to Binary Conversion
- •Short CAPCODE
- •Long CAPCODE 2,101,249 to 1,075,843,072
- •Long CAPCODE 1,075,843,073 to 3,223,326,720
- •Long CAPCODE 3,223,326,721 to 4,297,068,542
- •Binary to CAPCODE Conversion
- •CAPCODE Assignments
- •SPI Packets
- •Packet Communication Initiated by the Host
- •Packet Communication Initiated by the FLEXchip IC
- •1. The FLEXchip IC drives the READY pin low.
- •Host-to-Decoder Packet Map
- •Decoder-to-Host Packet Map
- •Host-to-Decoder Packet Descriptions
- •Checksum Packet
- •Configuration Packet
- •Oscillator Frequency Difference (OFD)
- •Signal Polarity (SP)
- •Normal
- •Normal
- •Normal
- •Inverted
- •Inverted
- •Normal
- •Inverted
- •Inverted
- •Synchronous Mode Enable (SME)
- •Maximum Off Time (MOT)
- •Clock Output Disable (COD)
- •Minute Timer Enable (MTE)
- •Low Battery Polarity (LBP)
- •Control Packet
- •Force Frame (FF) 0–7
- •Single Phase Mode (SPM)
- •Phase Select (PS)
- •Send Block Information (SBI) words 2-4
- •Minute Timer Clear (MTC)
- •Turn On Decoder (ON)
- •All Frame Mode Packet
- •Decrement All Frame (DAF) Counter
- •Force All Frame (FAF) Mode
- •Decrement Temporary Address (DTA) Enable Counter
- •Receiver Line Control Packet
- •Force Receiver Setting (FRS)
- •Control Line Setting (CLS)
- •Receiver Control Configuration Packets
- •Low Battery Check (LBC)
- •Control Line Setting (CLS)
- •Step Time (ST)
- •Receiver Warm Up Setting Packets
- •Setting Number (s)
- •Warm Up 1
- •Warm Up 2
- •Warm Up 3
- •Warm Up 4
- •Warm Up 5
- •Step Enable (SE)
- •Low Battery Check (LBC)
- •Control Line Setting (CLS)
- •Step Time (ST)
- •3200 sps Sync Setting Packets
- •Low Battery Check (LBC)
- •Control Line Setting (CLS)
- •Step Time (ST)
- •Receiver On Setting Packets
- •Setting Number (s)
- •1600 sps Sync
- •3200 sps Data
- •1600 sps Data
- •Low Battery Check (LBC)
- •Control Line Setting (CLS)
- •Receiver Shut Down Setting Packets
- •Setting Number (s)
- •Shut Down 1
- •Shut Down 2
- •Step Enable (SE)
- •Low Battery Check (LBC)
- •Control Line Setting (CLS)
- •Step Time (ST)
- •Frame Assignment Packets
- •Frame range (f)
- •Frame 127
- •Frame 112
- •Frame 111
- •Frame 96
- •Frame 95
- •Frame 80
- •Frame 79
- •Frame 64
- •Frame 63
- •Frame 48
- •Frame 47
- •Frame 32
- •Frame 31
- •Frame 16
- •Frame 15
- •Frame 0
- •Assigned Frame (AF)
- •User Address Enable Packet
- •User Address Assignment Packets
- •User Address Word Number (a0–a3)
- •Long Address (LA)
- •Tone-Only Address (TOA)
- •Address word (A0–A20)
- •Decoder-to-Host Packet Descriptions
- •Block Information Word Packet
- •Address Packet
- •Priority Address (PA)
- •Phase (p)
- •Long Address type (LA)
- •Address Index (AI)
- •Tone Only Address (TOA)
- •Word number (WN) of vector (2–87)
- •Unused bits (x)
- •Vector Packet
- •Short Message / Tone Only Vector
- •Numeric Vector Packet
- •Vector Type Identifier (V)
- •Additional Bit Descriptors
- •Vector Type Identifier (V)
- •Secure
- •Alphanumeric
- •Hex / Binary
- •Additional Bit Descriptors
- •Short Instruction Vector
- •Message Packet
- •Status Packet
- •Frame Info Valid (FIV)
- •Current frame number (f)
- •Synchronous Mode (SM)
- •Low Battery (LB)
- •Current System Cycle Number (c)
- •Synchronous Mode Update (SMU)
- •Low Battery Update (LBU)
- •Minute Time-out (MT)
- •End Of Frame (EOF)
- •Buffer Overflow Error (BOE)
- •Unused bits (x)
- •Part ID Packet
- •Model (MDL)
- •Compatibility ID (CID)
- •Revision (REV)
- •Application Notes
- •Receiver Control
- •Introduction
- •1. what setting is applied to the control lines,
- •2. how long to apply the setting, and
- •Receiver Settings at Reset
- •Normal Receiver Warm Up Sequence
- •First Receiver Warm Up Sequence
- •Receiver Shut Down Sequence
- •Miscellaneous Receiver States
- •Low Battery Detection
- •Message Building
- •ADDRESS 1
- •ADDRESS 2
- •LONG ADDRESS 3 WORD 1
- •LONG ADDRESS 3 WORD 2
- •VECTOR 1
- •VECTOR 2
- •MESSAGE 1, 1
- •MESSAGE 1, 2
- •VECTOR 3
- •MESSAGE 1, 3
- •MESSAGE 3, 1
- •MESSAGE 2, 1
- •MESSAGE 2, 2
- •MESSAGE 2, 3
- •MESSAGE 3, 2
- •MESSAGE 2, 4
- •MESSAGE 3, 3
- •ADDRESS
- •ADDRESS
- •VECTOR
- •VECTOR
- •MESSAGE
- •MESSAGE
- •MESSAGE
- •MESSAGE
- •MESSAGE
- •MESSAGE
- •MESSAGE
- •VECTOR
- •MESSAGE
- •MESSAGE
- •MESSAGE
- •Building a Fragmented Message
- •ADDRESS 1
- •VECTOR 1
- •MESSAGE
- •ADDRESS 1
- •VECTOR 1
- •MESSAGE
- •STATUS
- •ADDRESS 1
- •VECTOR 1
- •MESSAGE
- •STATUS
- •ADDRESS 1
- •VECTOR 1
- •MESSAGE
- •Operation of a Temporary Address
- •Group Messaging

|
|
|
|
SPI Packets |
|
|
|
|
|
|
|
|
|
|
|
Decoder-to-Host Packet Descriptions |
|
|
|
|
Table B-36 Short Instruction Vector Definition |
||
|
|
|
|
||
|
i2i1i0 |
d10 d9 d8 d7 d6 d5 d4 d3 d2 d1 d0 |
Description |
||
|
|
|
|
|
|
|
111 |
|
|
Reserved for test |
|
|
|
|
|
|
|
|
Note: |
1. |
Assigned temporary address (a) and assigned frame (f). See Appendix C for additional |
||
|
|
|
information. |
|
|
|
|
2. |
i = Instruction type—These bits define the meaning of the d bits in this packet. |
||
|
|
|
x = Unused bits—The value of these bits is not guaranteed. |
||
|
|
|
|
|
|
Message Packet
The Message Field follows the Vector Field in the FLEX protocol. It contains the message data, checksum information, and may contain fragment numbers and message numbers. See Appendix A for additional information. If the error bit of a vector word is not set and the vector word indicates that there are message words associated with the page, the message words are sent in Message Packets. The ID of the Message Packet is the word number where the message word was received in the frame.
Table B-37 Message Packet Bit Assignments
Byte |
Bit 7 |
Bit 6 |
Bit 5 |
Bit 4 |
Bit 3 |
Bit 2 |
Bit 1 |
Bit 0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3 |
0 |
WN6 |
WN5 |
WN4 |
WN3 |
WN2 |
WN1 |
WN0 |
|
|
|
|
|
|
|
|
|
2 |
e |
p1 |
p0 |
i20 |
i19 |
i18 |
i17 |
i16 |
1 |
i15 |
i14 |
i13 |
i12 |
i11 |
i10 |
i9 |
i8 |
0 |
i7 |
i6 |
i5 |
i4 |
i3 |
i2 |
i1 |
i0 |
|
|
|
|
|
|
|
|
|
Note: WN = Word number of message word (3–87 decimal)—Describes the location of the message word in the frame
e is set if more than 2 bit errors are detected in the word.
p = Phase on which the message word was found (0 = a, 1 = b, 2 = c, 3 = d)
i = information bits of the message word—The definitions of these bits depend on the vector type and which word of the message is being received. See Appendix A for a detailed description of these bits.
MOTOROLA |
MC68175/D, Preliminary |
B-31 |