- •WAGO-I/O-SYSTEM 750
- •System Description
- •General
- •Coupler/Controller (1)
- •I/O Modules (2)
- •End Module (3)
- •Installation
- •Safety notes
- •Mechanical Installation
- •Electrical Installation
- •Wire Connection
- •Change fuse
- •Power supply
- •System supply voltage
- •Supply Voltage Field Side
- •Manufacturing Number
- •Technical Data
- •Fieldbus coupler/controller
- •Fieldbus coupler 750-319
- •Description
- •Software for the coupler
- •Hardware
- •View
- •Device supply
- •Fieldbus connection
- •Display elements
- •Configuration interface
- •Hardware address
- •Operating system
- •Data exchange
- •Starting-up LON fieldbus nodes
- •LED display
- •Blink code
- •Fieldbus status
- •Node status
- •Fault message via the blink code of the I/O LED
- •Supply voltage status
- •Fault behavior
- •Fieldbus failure
- •Internal bus fault
- •Technical Data
- •Fieldbus controller 750-819
- •Description
- •Software for the controller
- •Hardware
- •View
- •Device supply
- •Fieldbus connection
- •Display elements
- •Configuration and programming interface
- •Operating mode switch
- •Hardware address
- •Operating system
- •Start-up
- •PLC cycle
- •Process image
- •Data exchange
- •Memory areas
- •Addressing
- •Addressing the I/O modules
- •Addressing the PFC variables
- •Addressing the configuration variables
- •Starting-up LON fieldbus nodes
- •Programming the PFC with WAGO-I/O-PRO 32
- •LON library elements for WAGO-I/O-PRO 32
- •IEC 61131-3 Program transfer
- •Transmission via the serial interface
- •Transmission via the fieldbus
- •LED display
- •Blink code
- •Fieldbus status
- •Node status
- •Fault message via the blink code of the I/O LED
- •Supply voltage status
- •Fault behavior
- •Fieldbus failure
- •Internal bus fault
- •Technical Data
- •I/O modules
- •Digital Inputs
- •Digital Outputs
- •Analog Inputs
- •Analog Outputs
- •Speciality modules
- •Supply modules
- •Potential multiplication module
- •Binary spacer modules
- •Separation module/ end module
- •General Safty Information!
- •Information on the network architecture
- •Transmision media
- •Topology
- •Transceiver
- •Recommended bus and cable lengths
- •Bus shaped wiring
- •Free Wiring
- •Cable specifications
- •Network installation
- •Addressing
- •Configuration
- •Binding
- •Network communication
- •Data exchange via network variables
- •Standard types of network variables
- •Protocol
- •Channel access method
- •Application in Explosive Environments
- •Foreword
- •Protective measures
- •Classification meeting CENELEC and IEC
- •Divisions
- •Explosion protection group
- •Unit categories
- •Temperature classes
- •Types of ignition protection
- •Classifications meeting the NEC 500
- •Divisions
- •Explosion protection groups
- •Temperature classes
- •Identification
- •For Europe
- •For America
- •Installation regulations
- •Glossary
- •Literature list
- •Index
86 • I/O modules
Digital Outputs - Review
4.2 Digital Outputs
750-501 (2 Channel DO, DC 24 V, 0,5A) |
|
||
750-502 (2 Channel DO, DC 24 |
V, 2,0 |
A) |
page 87 |
|
|
|
|
|
|
|
|
750-504 (4 Channel DO, DC 24 |
V, 0,5A) |
page 89 |
|
|
|
|
|
|
|
|
|
|
|
|
|
750-506 (2 Channel DO, DC 24 |
V, 0,5 |
A) diagn. |
page 91 |
|
|
|
|
|
|
|
|
|
|
|
|
750-507 (2 Channel DO, DC 24 |
V, 2,0 |
A) diagn. |
page 93 |
|
|
|
|
|
|
|
|
|
|
|
|
750-509 (2 Channel Solid State Relay, 2) Outputs, AC 230 V, 0,3 A) page 96
750-512 (Digital Output Relay, 2 normally open contact non-floating, AC 250 V)
page 98
750-513 (Digital Output Relay, 2 normally open contact, isolated outputs, AC 250 V, 2,0 A)
page 100
750-514 (Digital Output Relay, 2 changeover contact, isolated outputs, AC 125 V, 0,5 A)
page 102
750-516 (4 Channel DO, DC 24 V, 0,5A)
page 104
750-517 (Digital Output Relay, 2 changeover contact, isolated outputs, AC 230 V, 1,0 A)
page 106
750-519 (4 Channel DO, DC 5 V, 20 mA)
page 108
Modular I/O System
LONWORKS®
|
I/O modules |
• 87 |
|
Digital Output 750-501, -502 |
|
|
|
|
4.2.1.1.1 2 Channel Digital Outputs |
|
|
(Standard, DC 24 V, 0,5 A / 2 A) |
750-501, -502 |
|
13 |
14 |
Status |
|
A |
|
DO 1 |
C |
B |
|
|
D |
13 |
14 |
DO 1 |
|
+ |
+ |
- |
- |
750-501 |
|
Status
DO 2
Data contacts
DO 2
24V
0V
Power jumper contacts
Technical Description:
The supply is applied by the power jumper contacts on each I/O module for the respective operating voltage. Power connections are made automatically from module to module when snapped onto the DIN rail.
For the digital outputs (with or without diagnostic) four-conductor devices (Ub+; Ub-; signal; ground) are standard.
All digital outputs are short-circuit protected.
Attention
In case of overloads a supply module with fuse (750-601) must be connected on the line side to protect the output modules.
The indicated output values have been determined for 100% duty cycle.
However, in case of the 2 A versions it is possible to operate single channels at higher load currents, however always verify that the total current does not exceed 4 A per module.
Example: 2 x 2A (standard); 1 x 3,5A; 1 x 0,5A (total current: 4A)
The positions of the different I/O modules in the configured node/station are selectable by the user. A block type configuration is not necessary.
The Output module can be connected to all buscouplers of the WAGO-I/O-SYSTEM.
Modular I/O System
LONWORKS®
88 • I/O modules
Digital Output 750-501, -502
Technical Data:
Item no.: |
750-501 |
|
750-502 |
|
|
|
|
Number of outputs |
|
2 |
|
Kind of load |
resistive, inductive, lamps |
||
|
|
||
Voltage via power jumper con- |
DC 24V (-15% / +20%) |
||
tacts |
|
|
|
Output current (DC) |
0,5 A |
|
2 A |
|
|
|
|
Current consumption (internal) |
|
7 mA |
|
Input current (field side) |
|
15 mA typ. + Last |
|
|
|
||
Isolation |
500 V system/power supply |
||
Internal bit width |
|
2 |
|
|
|
||
Configuration |
no address or configuration adjustment |
||
Operating temperature |
|
0°C....+55°C |
|
|
|
||
Wire connection |
CAGE CLAMP ; 0,08 mm2 - 2,5 mm2, AWG 28 – 14, |
||
|
8 – 9 mm Stripped length |
||
Dimensions (mm) WxHxL |
12 x 64* x 100 (*from upper edge of carrier rail) |
||
|
|
|
|
Modular I/O System
LONWORKS®
|
I/O modules |
• 89 |
|
Digital Output 750-504 |
|
|
|
|
4.2.1.1.2 4 Channel Digital Outputs |
|
|
(Standard, DC 24 V, 0,5 A) |
750-504 |
|
Status |
13 |
14 |
A |
|
|
DO 1 |
|
|
|
C |
|
DO 3 |
B |
|
|
D |
|
|
13 |
14 |
DO 1 |
|
|
|
+ |
+ |
|
- |
- |
|
15 |
16 |
DO 3 |
|
|
|
750-504 |
|
Status
DO 2
DO 4
Data contacts
DO 2
24V
0V
DO 4
Power jumper contacts
Technical Description:
The supply is applied by the power jumper contacts on each I/O module for the respective operating voltage. Power connections are made automatically from module to module when snapped onto the DIN rail.
For the digital outputs (with or without diagnostic) four-conductor devices (Ub+; Ub-; signal; ground) are standard.
In case of 12 mm wide 4-channel digital output modules it is not possible to use 4-conductor devices. 4 signal outputs, 2xV+ and 2x0V are provided.
All digital outputs are short-circuit protected.
Attention
In case of overloads a supply module with fuse (750-601) must be connected on the line side to protect the output modules.
The indicated output values have been determined for 100% duty cycle.
The positions of the different I/O modules in the configured node/station are selectable by the user. A block type configuration is not necessary.
The Output module can be connected to all buscouplers of the WAGO-I/O-SYSTEM.
Modular I/O System
LONWORKS®
90 • I/O modules
Digital Output 750-504
Technical Data:
Item no.: |
750-504 |
|
|
Number of outputs |
4 |
Kind of load |
resistive, inductive, lamps |
|
|
Voltage via power jumper contacts |
DC 24 V (-15% / +20%) |
Output current (DC) |
0,5 A short-circuit protected |
|
|
Current consumption (internal) |
15 mA |
Input current (field side) |
30 mA typ. + Last |
|
|
Isolation |
500 V system/power supply |
Internal bit width |
4 |
|
|
Configuration |
no address or configuration adjustment |
Operating temperature |
0°C....+55°C |
|
|
Wire connection |
CAGE CLAMP ; 0,08 mm2 - 2,5 mm2, AWG 28 – 14, |
|
8 – 9 mm Stripped length |
Dimensions (mm) WxHxL |
12 x 64* x 100 (*from upper edge of carrier rail) |
|
|
Modular I/O System
LONWORKS®
|
I/O modules |
• 91 |
|
Digital Output 750-506 |
|
|
|
|
4.2.1.1.3 2 Channel Digital Outputs |
|
|
(Standard with diagnostics, DC 24 V, 0,5 A) |
750-506 |
|
Status DO 1
Error DO 1
DO 1
13 |
14 |
A |
|
|
C |
B |
|
|
D |
13 |
14 |
+ |
+ |
- |
- |
750-506 |
|
Status DO 2
Error DO 2
Data contacts
DO 2
24V
0V
Power jumper contacts
Technical Description:
The supply is applied by the power jumper contacts on each I/O module for the respective operating voltage. Power connections are made automatically from module to module when snapped onto the DIN rail.
Using the digital outputs with diagnostic bit outputs (750-506) allows verification of the I/O channel by the connected bus.
For example: a short-circuit at the output or an open circuit will set the appropriate error bit true indicating I/O failure.
In this configuration the I/O-module includes 4 digital outputs and 4 separate digital inputs. For the digital outputs with diagnostic four-conductor devices (V+; 0V; signal; ground) are standard.
All digital outputs are short-circuit protected.
Attention
In case of overloads a supply module with fuse (750-601) must be connected on the line side to protect the output modules.
When using I/O modules with diagnostics, the existing 4 inputs must be considered accordingly in the configuration of the node.
The Output module can be connected to all buscouplers of the WAGO-I/O-SYSTEM.
Modular I/O System
LONWORKS®
92 • I/O modules
Digital Output 750-506
Technical Data:
Item no.: |
750-506 |
|
|
Number of outputs |
2 |
Current consumption (internal) |
15 mA |
|
|
Voltage via power jumper con- |
DC 24 V (- 15 % / + 20 %) |
tacts |
|
Kind of load |
resistive, inductive, lamps |
|
|
Output current (DC) |
0,5 A short-circuit protected |
Diagnostics |
open circuit, overload |
|
|
Isolation |
500 V system/power supply |
Input current (field side) |
15 mA typ. + load |
|
|
Internal bit width |
4 in; 4 out |
Configuration |
without address or configuration adjustment |
|
|
Operating temperature |
0 °C ... + 55 °C |
Wire connection |
CAGE CLAMP ; 0,08 mm2 - 2,5 mm2, AWG 28 – 14, |
|
8 – 9 mm Stripped length |
|
|
Dimensions (mm) WxHxL |
12 x 64* x 100 (*from upper edge of carrier rail) |
|
|
The output bits control the state of the outputs.
Bit: |
Bit 3 |
Bit 2 |
Bit 1 |
Bit 0 |
Function: |
no function |
no function |
controls O2 |
controls O1 |
The input bits show the state of the output channels.
Bit: |
Bit 3 |
Bit 2 |
Bit 1 |
Bit 0 |
Function: |
diagnostics |
diagnostics |
diagnostics |
diagnostics |
|
O2 |
O2 |
O1 |
O1 |
|
|
|
|
|
output follows output bit: |
0 |
0 |
0 |
0 |
no load is connected: |
0 |
1 |
0 |
1 |
short circuit: |
1 |
0 |
1 |
0 |
power supply too low*: |
1 |
1 |
1 |
1 |
*The diagnostic bits refer to a hysteresis:
-If the voltage of the field side is higher than 11V in the falling circle, they are switched on.
-If the voltage is lower than 15.5 V in the growing circle, they are switched off.
Modular I/O System
LONWORKS®
|
I/O modules |
• 93 |
|
Digital Output 750-507 |
|
|
|
|
4.2.1.1.4 2 Channel Digital Outputs |
|
|
(Standard with diagnostics, DC 24 V, 2,0 A) |
750-507 |
|
Status DO 1
Error DO 1
DO 1
13 |
14 |
A |
|
|
C |
B |
|
|
D |
13 |
14 |
+ |
+ |
- |
- |
750-506 |
|
Status DO 2
Error DO 2
Data contacts
DO 2
24V
0V
Power jumper contacts
Technical Description:
The supply is applied by the power jumper contacts on each I/O module for the respective operating voltage. Power connections are made automatically from module to module when snapped onto the DIN rail.
Using the digital outputs with diagnostic bit outputs (750-507) allows verification of the I/O channel by the connected bus.
For example: a short-circuit at the output or an open circuit will set the appropriate error bit true indicating I/O failure.
In this configuration the I/O-module includes 2 digital outputs and 2 separate digital inputs. For the digital outputs with diagnostic four-conductor devices (V+; 0V; signal; ground) are standard.
All digital outputs are short-circuit protected.
Attention
In case of overloads a supply module with fuse (750-601) must be connected on the line side to protect the output modules.
When using I/O modules with diagnostics, the existing 2 inputs must be considered accordingly in the configuration of the node.
The Output module can be connected to all buscouplers of the WAGO-I/O-SYSTEM.
Modular I/O System
LONWORKS®
94 • I/O modules
Digital Output 750-507
Technical Data:
Item no.: |
750-507 |
|
|
Number of outputs |
2 |
Current consumption (internal) |
15 mA |
|
|
Voltage via power jumper contacts |
DC 24 V (- 15 % / + 20 %) |
Kind of load |
resistive, inductive, lamps |
|
|
Reverse voltage protection |
yes |
Output current (DC) |
2,0 A short-circuit protected |
|
|
Short circuit limitation |
I(scp) 42 A typ. |
|
I(scr) 33 A typ. |
Open circuit detection |
II(off) < 30 A typ. |
Cutoff frequency |
2,5 kHz |
|
|
Diagnostics |
open-circuit, overload and short circuit |
Isolation |
500 V system/power supply |
|
|
Input current (field side) |
15 mA typ. + load |
Internal bit width |
2 in; 2 out |
|
|
Configuration |
without address or configuration adjustment |
Operating temperature |
0 °C ... + 55 °C |
|
|
Wire connection |
CAGE CLAMP ; 0,08 mm2 - 2,5 mm2, AWG 28 – 14, |
|
8 – 9 mm Stripped length |
Dimensions (mm) WxHxL |
12 x 64* x 100 (*from upper edge of carrier rail) |
|
|
The possibility to diagnostic with 750-507 with each output channel:
Status from PLC to |
LED green |
LED red |
Description |
|
module |
(Output) |
(diagnostic) |
|
|
H |
ON |
OFF |
Output O.K. |
|
|
|
|
||
L |
OFF |
OFF |
||
|
||||
|
|
|
|
|
H |
ON |
OFF |
OPEN circuit*) |
|
|
|
|
||
L |
OFF |
ON |
||
|
||||
|
|
|
|
|
H |
OFF |
ON |
Short circuit with GND*) |
|
|
|
|
||
L |
OFF |
OFF |
||
|
||||
|
|
|
|
|
H |
ON |
OFF |
Short circuit with +24 V. *) |
|
|
|
|
||
L |
ON |
ON |
||
|
||||
|
|
|
|
|
H |
OFF |
ON |
Overtemperature or |
|
L |
OFF |
ON |
Overor Undervoltage *) |
*) The full diagnostic is only possible with the status bit and the two LED's on the module.
Modular I/O System
LONWORKS®
I/O modules • 95
Digital Output 750-507
The output bits control the state of the outputs.
Bit: |
Bit 1 |
Bit 0 |
Function: |
controls O2 |
controls O1 |
The input bits show the state of the output channels.
Bit: |
Bit 1 |
Bit 0 |
Function: |
diagnostics O2 |
diagnostics O1 |
|
|
|
output follows output bit: |
0 |
0 |
no load is connected: |
1 |
1 |
short circuit: |
1 |
1 |
short circuit from O1 or O2 to 24V: |
1 |
1 |
temperature is too high, because of overload |
1 |
1 |
*The diagnostic bits refer to a hysteresis: |
|
|
-If the voltage of the field side is higher than 11V in the falling circle, they are switched on.
-If the voltage is lower than 15.5 V in the growing circle, they are switched off.
Modular I/O System
LONWORKS®
96 • I/O modules
Digital Output 750-509
4.2.1.1.5 2 Channel Digital Outputs |
|
(Solid State Relay, AC 230 V, 0,3 A) |
750-509 |
Status |
13 |
14 |
|
|
|
DO 1 |
A |
|
B |
C |
|
|
|
|
|
|
D |
|
13 |
14 |
DO 1 |
|
|
|
L |
L |
|
N |
N |
|
750-509 |
|
Status
DO 2
Data contacts
DO 2
230V
N
Power jumper contacts
Technical Description:
The supply is applied by the power jumper contacts on each I/O module for the respective operating voltage 230 V. Power connections are made automatically from module to module when snapped onto the DIN rail.
The power supply of the control side is not made via the power jumper contacts but directly from the electronics. The respective output contacts of the switching element are therefore always positioned at the field side. One termination point of these contacts must be directly connected to the power supply through a power feed module.
For the digital outputs four-conductor devices (V+; 0V; signal; ground) are standard.
All digital outputs are short-circuit protected.
Attention
In case of overloads a supply module with fuse (750-609) must be connected on the line side to protect the output modules.
The Output module can be connected to all buscouplers of the WAGO-I/O-SYSTEM.
Modular I/O System
LONWORKS®
I/O modules • 97
|
|
Digital Output 750-509 |
|
|
Technical Data: |
|
|
|
|
|
|
|
Item no.: |
750-509 |
|
|
|
|
|
|
Number of outputs |
2 |
|
|
Current consumption (internal) |
10 mA |
|
|
|
|
|
|
Switching voltage |
AC/DC 0 V ... 230 V |
|
|
Switching current |
300 mA |
|
|
|
|
|
|
Speed of operation |
1,65 ms typ.; 5 ms max. |
|
|
Volume resistance |
2,1 Ω typ.; 3,2 Ω max. |
|
|
|
|
|
|
Impulse current |
0,5 A (20 s); 1,5 A (0,1 s) |
|
|
Overvoltage protection |
> ± 380 V (varistor) |
|
|
|
|
|
|
Isolation |
1,5 kV system/power supply |
|
|
Internal bit width |
2 |
|
|
|
|
|
|
Configuration |
without address or configuration adjustment |
|
|
Operating temperature |
0 °C ... + 55 °C |
|
|
|
|
|
|
Wire connection |
CAGE CLAMP ; 0,08 mm2 - 2,5 mm2, AWG 28 – 14, |
|
|
|
8 – 9 mm Stripped length |
|
|
Dimensions (mm) WxHxL |
12 x 64* x 100 (*from upper edge of carrier rail) |
|
|
|
|
|
Modular I/O System
LONWORKS®
98 • I/O modules
Digital Output 750-512
4.2.1.1.6 Digital Output Relay |
|
(2 normally open contact, non-floating, AC 250 V) |
750-512 |
Status |
13 |
14 |
|
|
|
Relay 1 |
A |
|
|
C |
|
|
B |
|
|
|
D |
|
13 |
14 |
DO 1 |
|
|
|
L |
L |
|
0V |
0V |
|
750-512 |
|
Status
Relay 2
Data contacts
DO 2
AC 230 V
DC 30 V
N
0 V
Power jumper contacts
Technical Description:
The power supply for the relay coils is not made via the power jumper contacts but directly from the electronics. The respective output contacts of the switching element are therefore always positioned at the field side.
The power supply is made via a series-connected supply terminal block for the respective operating voltage. Power connections are made automatically from module to module when snapped onto the DIN rail. One termination point of these contacts must be directly connected to the power supply.
The Output module can be connected to all buscouplers of the WAGO-I/O-SYSTEM.
Modular I/O System
LONWORKS®
|
|
I/O modules • 99 |
|
|
|
Digital Output 750-512 |
|
|
|
|
|
|
Technical Data: |
|
|
|
|
|
|
|
Item no.: |
750-512 |
|
|
|
|
|
|
Number of outputs |
2 normally open contacts |
|
|
Current consumption (internal) |
100 mA max. |
|
|
|
|
|
|
Switching voltage Relay |
AC 250 V / DC 30 V |
|
|
Switching power Relay |
500 VA / 60 W, cos ρ max =0,4, L/Rmax=7 ms |
|
|
|
|
|
|
Switching current Relay |
AC/DC 2 A |
|
|
Isolation |
4 kV system/power supply |
|
|
|
|
|
|
Internal bit width |
2 |
|
|
Configuration |
without address or configuration adjustment |
|
|
|
|
|
|
Operating temperature |
0 °C ... + 55 °C |
|
|
Wire connection |
CAGE CLAMP ; 0,08 mm2 - 2,5 mm2, AWG 28 – 14, |
|
|
|
8 – 9 mm Stripped length |
|
|
|
|
|
|
Dimensions (mm)WxHxL |
12 x 64* x 100 (*from upper edge of carrier rail) |
|
|
|
|
|
Relays in the modules 750-512
50
30
10
DC, inductive load
(A) |
5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
current |
3 |
DC, resis- |
|
|
|
||
|
tive load |
|
AC, in- |
||||
|
|
|
|
|
|||
|
|
|
|
|
ductive |
||
Switching |
1 |
AC, resis- |
|
||||
|
load |
|
|||||
|
tive load |
|
|
||||
|
|
cos |
= |
||||
0,5 |
|
|
|
|
|||
|
|
|
|
0,4 |
|
||
0,3 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0,1 |
|
|
|
|
|
|
|
0 |
3 |
5 |
10 |
30 |
100 |
250 500 1000 |
Switching voltage (V)
g051202e
Modular I/O System
LONWORKS®
100 • I/O modules
Digital Output 750-513
4.2.1.1.7 Digital Output Relay |
|
(2 normally open contact, isolated outputs, AC 250, 2,0 A) |
750-513 |
Status |
K1 |
K2 |
|
|
|
Relay 1 |
A |
|
|
C |
|
|
B |
|
|
|
D |
|
14 |
24 |
DO 1 |
|
|
|
13 |
23 |
L 1 |
|
|
|
750-513 |
|
Status
Relay 2
Data contacts
DO 2
L 2 |
N |
Power jumper contact
Technical Description:
The power supply for the relay coils is not made via the power jumper contacts but directly from the electronics. The respective output contacts of the switching element are therefore always positioned at the field side.
These I/O modules are not provided with integrated power jumper contacts. Care should be taken to supply each isolated module with separate power supply connections. A connection to ground is made through the series power jumper contact to a power feed module.
The Output module can be connected to all buscouplers of the WAGO-I/O-SYSTEM.
Modular I/O System
LONWORKS®
|
|
I/O modules • 101 |
|
|
|
Digital Output 750-513 |
|
|
|
|
|
|
Technical Data: |
|
|
|
|
|
|
|
Item no.: |
750-513 |
|
|
|
|
|
|
Number of outputs |
2 normally open contacts |
|
|
Current consumption (internal) |
100 mA max. |
|
|
|
|
|
|
Switching voltage Relay |
AC 250 V / DC 30 V |
|
|
Switching power Relay |
500 VA / 60 W, cos ρ max =0,4, L/Rmax=7 ms |
|
|
|
|
|
|
Switching current Relay |
AC/DC 2 A |
|
|
Isolation |
4 kV system/power supply |
|
|
|
|
|
|
Internal bit width |
2 |
|
|
Configuration |
without address or configuration adjustment |
|
|
|
|
|
|
Operating temperature |
0 °C ... + 55 °C |
|
|
Wire connection |
CAGE CLAMP ; 0,08 mm2 - 2,5 mm2, AWG 28 – 14, |
|
|
|
8 – 9 mm Stripped length |
|
|
|
|
|
|
Dimensions (mm)WxHxL |
12 x 64* x 100 (*from upper edge of carrier rail) |
|
|
|
|
|
Relays in the modules 750-513
50
30
10
DC, inductive load
(A) |
5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
current |
3 |
DC, resis- |
|
|
|
||
|
tive load |
|
AC, in- |
||||
|
|
|
|
|
|||
|
|
|
|
|
ductive |
||
Switching |
1 |
AC, resis- |
|
||||
|
load |
|
|||||
|
tive load |
|
|
||||
|
|
cos |
= |
||||
0,5 |
|
|
|
|
|||
|
|
|
|
0,4 |
|
||
0,3 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0,1 |
|
|
|
|
|
|
|
0 |
3 |
5 |
10 |
30 |
100 |
250 500 1000 |
Switching voltage (V)
g051302e
Modular I/O System
LONWORKS®
102 • I/O modules
Digitale Ausgangsklemme 750-514
4.2.1.1.8 Digital Output Relay |
|
(2 changeover contact, isolated outputs, AC 125 V, 0,5 A) |
750-514 |
Status |
K1 |
K2 |
|
|
|
Relay 1 |
A |
|
|
C |
|
|
B |
|
|
|
D |
|
14 |
24 |
DO 1 |
|
|
|
11 |
21 |
L 1 |
|
|
|
12 |
22 |
DO 1 |
|
|
|
750-514 |
|
Status
Relay 2
Data contacts
DO 2 |
N |
L 2
DO 2 |
N |
Power jumper contact
Technical Description:
The power supply for the relay coils is not made via the power jumper contacts but directly from the electronics. The respective output contacts of the switching element are therefore always positioned at the field side.
These I/O modules are not provided with integrated power jumper contacts. Care should be taken to supply each isolated module with separate power supply connections.
The Output module can be connected to all buscouplers of the
WAGO-I/O-SYSTEM.
Technical Data:
|
Item no.: |
750-514 |
|
|
|
|
|
|
Number of outputs |
2 changeover contacts |
|
|
Current consumption (internal) |
70 mA max. |
|
|
|
|
|
|
Switching voltage Relay |
AC 125 V / DC 30 V |
|
|
Switching power Relay |
62,5 VA/ 30 W |
|
|
|
|
|
|
Switching current Relay |
AC 0,5 A / DC 1 A |
|
|
Isolation |
1,5 kV system/power supply |
|
|
|
|
|
|
Internal bit width |
2 |
|
|
Configuration |
without address or configuration adjustment |
|
|
|
|
|
|
Operating temperature |
0 °C ... + 55 °C |
|
|
Wire connection |
CAGE CLAMP ; 0,08 mm2 - 2,5 mm2, AWG 28 – 14, |
|
|
|
8 – 9 mm Stripped length |
|
|
|
|
|
|
Dimensions (mm)WxHxL |
12 x 64* x 100 (*from upper edge of carrier rail) |
|
|
|
|
|
Modular I/O System
LONWORKS®
I/O modules • 103
Digital Output 750-516
Relays in the modules 750-514
AC, resistive load
|
2 |
|
|
|
|
(A) |
|
|
|
|
|
current |
1 |
|
|
|
|
|
DC, resistive load |
|
|||
|
|
|
|
|
|
Switching |
0,5 |
|
|
|
|
0,4 |
|
|
|
|
|
0,3 |
|
|
|
|
|
0,2 |
|
|
|
|
|
|
|
|
|
|
|
|
0,1 |
|
|
|
|
|
1 |
5 |
10 |
30 |
50 100 |
Switching voltage (V)
g051402e
Modular I/O System
LONWORKS®
104 • I/O modules
Digital Output 750-516
4.2.1.1.9 4 Channel Digital Outputs |
|
(Standard, DC 24 V, 0,5 A) |
750-516 |
Status |
13 |
14 |
A |
|
|
DO 1 |
|
|
|
C |
|
DO 3 |
B |
|
|
D |
|
|
13 |
14 |
DO 1 |
|
|
|
+ |
+ |
|
- |
- |
|
15 |
16 |
DO 3 |
|
|
|
750-516 |
|
Status
DO 2
DO 4
Data contacts
DO 2
24V
0V
DO 4
Power jumper contacts
Technical Description:
The supply is applied by the power jumper contacts on each I/O module for the respective operating voltage. Power connections are made automatically from module to module when snapped onto the DIN rail.
For the digital outputs (with or without diagnostic) four-conductor devices (Ub+; Ub-; signal; ground) are standard.
In case of 12 mm wide 4-channel digital output modules it is not possible to use 4-conductor devices. 4 signal outputs, 2xV+ and 2x0V are provided.
The module 750-516 is low-side switching.
All digital outputs are short-circuit protected.
Attention
In case of overloads a supply module with fuse (750-601) must be connected on the line side to protect the output modules.
The indicated output values have been determined for 100% duty cycle.
The positions of the different I/O modules in the configured node/station are selectable by the user. A block type configuration is not necessary.
The Output module can be connected to all buscouplers of the WAGO-I/O-SYSTEM.
Modular I/O System
LONWORKS®
|
|
I/O modules • 105 |
|
|
|
Digital Output 750-516 |
|
|
|
|
|
|
Technical Data: |
|
|
|
|
|
|
|
Item no.: |
750-516*) |
|
|
|
|
|
|
Number of outputs |
4 |
|
|
Kind of load |
resistive, inductive, lamps |
|
|
|
|
|
|
Voltage via power jumper contacts |
DC 24 V (-15% / +20%) |
|
|
Output current (DC) |
0,5 A short circuit protected |
|
|
|
|
|
|
Input current (internal) |
15 mA |
|
|
|
|
|
|
Input current (field side) |
30 mA typ. + load |
|
|
|
|
|
|
Isolation |
500 V system/power supply |
|
|
Internal bit width |
4 |
|
|
|
|
|
|
Configuration |
without address or configuration adjustment |
|
|
Operating temperature |
0°C....+55°C |
|
|
|
|
|
|
Wire connection |
CAGE CLAMP ; 0,08 mm2 - 2,5 mm2, AWG 28 – 14, |
|
|
|
8 – 9 mm Stripped length |
|
|
Dimensions (mm) WxHxL |
12 x 64* x 100 (*from upper edge of carrier rail) |
|
|
|
|
|
*) low-side switching
Modular I/O System
LONWORKS®
106 • I/O modules
Digital Output 750-517
4.2.1.1.10 Digital Output Relay |
|
(2 changeover contact, isolated outputs,, AC 250 V, 1 A) |
750-517 |
Status |
K1 |
K2 |
|
|
|
Relay 1 |
A |
|
|
C |
|
|
B |
|
|
|
D |
|
14 |
24 |
DO 1 |
|
|
|
11 |
21 |
L 1 |
|
|
|
12 |
22 |
DO 1 |
|
|
|
750-517 |
|
Status
Relay 2
Data contacts
DO 2 |
|
|
N |
|
|
L 2
|
|
|
|
N |
DO 2 |
|
|
||
Technical Description:
The power supply for the relay coils is not made via the power jumper contacts but directly from the electronics. The respective output contacts of the switching element are therefore always positioned at the field side.
The power supply is made via a series-connected supply terminal block for the respective operating voltage. Power connections are made automatically from module to module when snapped onto the DIN rail. One termination point of these contacts must be directly connected to the power supply.
These I/O modules are not provided with integrated power jumper contacts. Care should be taken to supply each isolated module with separate power supply connections.
The Output module can be connected to all buscouplers of the WAGO-I/O-SYSTEM.
Modular I/O System
LONWORKS®
|
|
I/O modules • 107 |
|
|
|
Digital Output 750-517 |
|
|
|
|
|
|
Technische Daten: |
|
|
|
|
|
|
|
Item no.: |
750-517 |
|
|
|
|
|
|
Number of outputs |
2 changeover contacts |
|
|
Current consumption (internal) |
80 mA max. |
|
|
|
|
|
|
Switching voltage Relay |
AC 250 V |
|
|
Switching power Relay |
250 VA |
|
|
|
|
|
|
Switching current Relay |
AC 1 A |
|
|
Isolation |
4 kV system/power supply |
|
|
|
|
|
|
Internal bit width |
2 |
|
|
Configuration |
without address or configuration adjustment |
|
|
|
|
|
|
Operating temperature |
0 °C ... + 55 °C |
|
|
Wire connection |
CAGE CLAMP ; 0,08 mm2 - 2,5 mm2, AWG 28 – 14, |
|
|
|
8 – 9 mm Stripped length |
|
|
|
|
|
|
Dimensions (mm)WxHxL |
12 x 64* x 100 (from upper edge of carrier) |
|
|
|
|
|
Relays in the modules 750-517
Switchingvoltage(V) |
Switching current (A)
g051702e
Modular I/O System
LONWORKS®
108 • I/O modules
Digital Output 750-519
4.2.1.1.114 Channel Digital Outputs
(DC 5 V, 20 mA) |
750-519 |
Status |
13 |
14 |
A |
|
|
DO 1 |
|
|
|
C |
|
DO 3 |
B |
|
|
D |
|
|
13 |
14 |
DO 1 |
|
|
|
+ |
+ |
|
- |
- |
|
15 |
16 |
DO 3 |
|
|
|
750-519 |
|
Status
DO 2
DO 4
Data contacts
DO 2
5V
0V
DO 4
Power jumper contacts
Technical Description:
The supply is applied by the power jumper contacts on each I/O module for the respective operating voltage. Power connections are made automatically from module to module when snapped onto the DIN rail.
For the digital outputs (with or without diagnostic) four-conductor devices (Ub+; Ub-; signal; ground) are standard.
In case of 12 mm wide 4-channel digital output modules it is not possible to use 4-conductor devices. 4 signal outputs, 2xV+ and 2x0V are provided.
The module 750-519 is high-side switching.
All digital outputs are short-circuit protected.
Attention
In case of overloads a supply module with fuse (750-601) must be connected on the line side to protect the output modules.
The indicated output values have been determined for 100% duty cycle.
The positions of the different I/O modules in the configured node/station are selectable by the user. A block type configuration is not necessary.
The Output module can be connected to all buscouplers of the WAGO-I/O-SYSTEM.
Modular I/O System
LONWORKS®
|
|
I/O modules • 109 |
|
|
|
Digital Output 750-519 |
|
|
|
|
|
|
Technical Data: |
|
|
|
|
|
|
|
Item no.: |
750-519 |
|
|
|
|
|
|
Number of outputs |
4 |
|
|
Kind of load |
resistive, inductive, lamps |
|
|
|
|
|
|
Voltage via power jumper contacts |
DC 5 V |
|
|
Output current (DC) |
20 mA kurzschlussfest |
|
|
|
|
|
|
Input current (internal) |
16 mA |
|
|
Input current (field side) |
14 mA typ. |
|
|
|
|
|
|
Isolation |
500 V system/power supply |
|
|
Internal bit width |
4 |
|
|
|
|
|
|
Configuration |
without address or configuration adjustment |
|
|
Operating temperature |
0°C....+55°C |
|
|
|
|
|
|
Wire connection |
CAGE CLAMP ; 0,08 mm2 - 2,5 mm2, AWG 28 – 14, |
|
|
|
8 – 9 mm Stripped length |
|
|
Dimensions (mm) WxHxL |
12 x 64* x 100 (*from upper edge of carrier rail) |
|
|
|
|
|
Modular I/O System
LONWORKS®