- •Table of Contents
- •Important comments
- •Legal disclaimers
- •Copyright
- •Personnel qualification
- •Intended use
- •Scope
- •Symbols
- •WAGO-I/O-SYSTEM 750
- •System Description
- •General
- •Coupler/Controller (1)
- •I/O Modules (2)
- •End Module (3)
- •Installation
- •Safety notes
- •Mechanical Installation
- •Electrical Installation
- •Wire Connection
- •Change fuse
- •Power supply
- •System supply voltage
- •Supply Voltage Field Side
- •Manufacturing Number
- •Technical Data
- •Fieldbus coupler/controller
- •Fieldbus coupler 750-319
- •Description
- •Software for the coupler
- •Hardware
- •View
- •Device supply
- •Fieldbus connection
- •Display elements
- •Configuration interface
- •Hardware address
- •Operating system
- •Data exchange
- •Starting-up LON fieldbus nodes
- •LED display
- •Blink code
- •Fieldbus status
- •Node status
- •Fault message via the blink code of the I/O LED
- •Supply voltage status
- •Fault behavior
- •Fieldbus failure
- •Internal bus fault
- •Technical Data
- •Fieldbus controller 750-819
- •Description
- •Software for the controller
- •Hardware
- •View
- •Device supply
- •Fieldbus connection
- •Display elements
- •Configuration and programming interface
- •Operating mode switch
- •Hardware address
- •Operating system
- •Start-up
- •PLC cycle
- •Process image
- •Data exchange
- •Memory areas
- •Addressing
- •Addressing the I/O modules
- •Addressing the PFC variables
- •Addressing the configuration variables
- •Starting-up LON fieldbus nodes
- •Programming the PFC with WAGO-I/O-PRO 32
- •LON library elements for WAGO-I/O-PRO 32
- •IEC 61131-3 Program transfer
- •Transmission via the serial interface
- •Transmission via the fieldbus
- •LED display
- •Blink code
- •Fieldbus status
- •Node status
- •Fault message via the blink code of the I/O LED
- •Supply voltage status
- •Fault behavior
- •Fieldbus failure
- •Internal bus fault
- •Technical Data
- •I/O modules
- •Digital Inputs
- •Digital Outputs
- •Analog Inputs
- •Analog Outputs
- •Speciality modules
- •Supply modules
- •Potential multiplication module
- •Binary spacer modules
- •Separation module/ end module
- •General Safty Information!
- •Information on the network architecture
- •Transmision media
- •Topology
- •Transceiver
- •Recommended bus and cable lengths
- •Bus shaped wiring
- •Free Wiring
- •Cable specifications
- •Network installation
- •Addressing
- •Configuration
- •Binding
- •Network communication
- •Data exchange via network variables
- •Standard types of network variables
- •Protocol
- •Channel access method
- •Application in Explosive Environments
- •Foreword
- •Protective measures
- •Classification meeting CENELEC and IEC
- •Divisions
- •Explosion protection group
- •Unit categories
- •Temperature classes
- •Types of ignition protection
- •Classifications meeting the NEC 500
- •Divisions
- •Explosion protection groups
- •Temperature classes
- •Identification
- •For Europe
- •For America
- •Installation regulations
- •Glossary
- •Literature list
- •Index
I/O modules • 63
4 I/O modules
All available bus modules intended for the modular configuration of applications with the WAGO-I/O-SYSTEM 750 are included in the following overview.
The following chapters contain a detailed description of each individual bus module and its variant.
Attention
Please make absolutely sure with some of the bus modules (e.g. 4 channel), that the bottom power jumper contact is not fed through!
This means that a bus module with three Power jumper contacts (e.g. 2 channel) cannot be snapped behind a bus module, in which not all contacts are led through.
Some relay modules only carry the third PJC, the grounding tab..
For the configuration of LON applications, there is already a large number of bus modules supported by the software TOPLON® IF and TOPLON® PRIO.
The types of modules which you can employ in conjunction with the WAGO TOPLON® software, are listed in the overview.
Symbol Meaning
Xsupported
-not supported
Onot relevant, because I/O module has no data
Note!
The bus module variations with the order No. 750-XXX/000-200 have the Numerical format for Siemens function blocks. This Numerical format is not supported by the WAGO TOPLON® software!
You are, of course, free to program your own LON applications in Neuron-C, which permits you to use and implement all other bus modules.
Modular I/O System
LONWORKS®
64 • I/O modules Review
Digital Inputs
Item- |
|
|
|
supported by |
|
|
No: |
notation |
TOPLON® |
TOPLON® |
see on |
||
750- |
|
|
IF |
|
PRIO |
page |
400 |
2 |
Channel Digital Input (filter 3.0 ms, 24 V DC) |
X |
|
X |
68 |
|
|
|
||||
|
|
|
|
|
|
|
401 |
2 |
Channel Digital Input (filter 0.2 ms, 24 V DC) |
X |
|
X |
68 |
|
|
|
||||
|
|
|
|
|
|
|
402 |
4 |
Channel Digital Input (filter 3.0 ms, 24 V DC) |
X |
|
X |
70 |
|
|
|
||||
|
|
|
|
|
|
|
403 |
4 |
Channel Digital Input (filter 0.2 ms, 24 V DC) |
X |
|
X |
70 |
|
|
|
||||
|
|
|
|
|
|
|
405 |
2 |
Channel Digital Input (230 V AC) |
X |
|
X |
72 |
|
|
|
||||
|
|
|
|
|
|
|
406 |
2 |
Channel Digital Input (120 V AC) |
X |
|
X |
74 |
|
|
|
||||
|
|
|
|
|
|
|
408 |
4 |
Channel Digital Input (filter 3.0 ms, 24 V DC) |
X |
|
X |
76 |
|
|
|
||||
|
|
|
|
|
|
|
409 |
4 |
Channel Digital Input (filter 0.2 ms, 24 V DC) |
X |
|
X |
76 |
|
|
|
||||
|
|
|
|
|
|
|
410 |
2 |
Channel Digital Input (filter 3.0 ms, 24 V DC) |
X |
|
X |
78 |
|
|
|
||||
|
|
|
|
|
|
|
411 |
2 |
Channel Digital Input (filter 0.2 ms, 24 V DC) |
X |
|
X |
78 |
|
|
|
||||
|
|
|
|
|
|
|
412 |
2 |
Channel Digital Input (filter 3.0 ms, 48 V DC) |
X |
|
X |
80 |
|
|
|
||||
|
|
|
|
|
|
|
414 |
4 |
Channel Digital Input (filter 0.2 ms, 5 V DC) |
X |
|
X |
82 |
|
|
|
||||
|
|
|
|
|
|
|
415 |
4 |
Channel Digital Input (filter 0.2 ms, 24 V AC/DC) |
X |
|
X |
84 |
|
|
|
||||
|
|
|
|
|
|
|
Digital Outputs |
|
|
|
|
||
|
|
|
|
|
|
|
Item- |
|
|
|
supported by |
|
|
No: |
notation |
TOPLON® |
TOPLON® |
see on |
||
750- |
|
|
IF |
|
PRIO |
page |
501 |
2 |
Channel Digital Output (0.5A, 24 V DC) |
X |
|
X |
87 |
|
|
|
||||
|
|
|
|
|
|
|
502 |
2 |
Channel Digital Output (2A, 24 V DC) |
X |
|
X |
87 |
|
|
|
||||
|
|
|
|
|
|
|
504 |
4 |
Channel Digital Output (0.5A, 24 V DC) |
X |
|
X |
89 |
|
|
|
||||
|
|
|
|
|
|
|
506 |
2 |
Channel Digital Output (0.5 A, 24 V DC)diagn. |
- |
|
X |
91 |
|
|
|
||||
|
|
|
|
|
|
|
507 |
2 |
Channel Digital Output (2.0 A, 24 V DC)diagn. |
- |
|
X |
93 |
|
|
|
||||
|
|
|
|
|
|
|
509 |
2 |
Channel Solid State Relay |
X |
|
X |
96 |
|
(2 Outputs 0.3 A, 230 V AC) |
|
|
|||
512 |
Digital Output Relay (2 normally open contact, non- |
X |
|
X |
98 |
|
|
floating, 250 V AC) |
|
|
|||
513 |
Digital Output Relay (2 normally open contact, isolated |
X |
|
X |
100 |
|
|
outputs, 2.0 A, 250 V AC) |
|
|
|||
514 |
Digital Output Relay (2 changeover contact, isolated out- |
X |
|
X |
102 |
|
|
puts, 0.5 A, 125 V AC) |
|
|
|||
516 |
4 |
Channel Digital Output (0.5A, 24 V DC) |
X |
|
X |
104 |
|
|
|
||||
|
|
|
|
|
|
|
517 |
Digital Output Relay (2 changeover contact, isolated out- |
- |
|
X |
106 |
|
|
puts, 1.0 A, 230 V AC) |
|
|
|||
519 |
4 |
Channel Digital Output (20 mA, 5 V DC) |
- |
|
X |
108 |
|
|
|
||||
|
|
|
|
|
|
|
Modular I/O System
LONWORKS®
|
|
|
|
|
|
I/O modules |
• 65 |
|||
|
|
|
|
|
|
|
Review |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Analog Inputs |
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
Item- |
|
|
|
supported by |
|
|
|
||
|
No: |
notation |
TOPLON® |
|
TOPLON® |
|
see on |
|
||
|
750- |
|
|
IF |
|
|
PRIO |
|
page |
|
|
452 |
2 |
Channel Analog Input (0-20mA, Diff.) |
X |
|
|
X |
|
111 |
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
454 |
2 |
Channel Analog Input (4-20mA, Diff.) |
X |
|
|
X |
|
111 |
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
456 |
2 |
Channel Analog Input (± 10V, Diff.) |
- |
|
|
X |
|
115 |
|
|
|
|
|
|
|
|
||||
|
461 |
2 |
Channel Input Pt 100 (RTD) |
X |
|
|
X |
|
118 |
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
462 |
2 |
Channel Analog Input Thermocouple |
X |
|
|
X |
|
123 |
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
465 |
2 |
Channel Analog Input (0-20mA |
X |
|
|
X |
|
131 |
|
|
|
single-ended) |
|
|
|
|
|
|||
|
466 |
2 |
Channel Analog Input (4-20mA |
X |
|
|
X |
|
131 |
|
|
|
single-ended) |
|
|
|
|
|
|||
|
467 |
2 |
Channel Analog Input (0-10 V single-ended) |
X |
|
|
X |
|
135 |
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
468 |
4 |
Channel Analog Input (0-10 V single-ended) |
X |
|
|
X |
|
138 |
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
469 |
2 |
Channel Analog Input Thermocouple (detection of broken |
X |
|
|
X |
|
141 |
|
|
|
wire) |
|
|
|
|
|
|||
|
472 |
2 |
Channel Analog Input (0-20mA single-ended) 16Bit |
- |
|
|
X |
|
148 |
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
474 |
2 |
Channel Analog Input (4-20mA single-ended) 16Bit |
- |
|
|
X |
|
148 |
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
476 |
2 |
Channel Analog Input (± 10 V DC |
- |
|
|
X |
|
151 |
|
|
|
single-ended) |
|
|
|
|
|
|
|
|
|
478 |
2 |
Channel Analog Input (0-10 V DC |
- |
|
|
X |
|
151 |
|
|
|
single-ended) |
|
|
|
|
|
|||
|
Analog Outputs |
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|||
|
Item- |
|
|
|
supported by |
|
|
|
||
|
No: |
notation |
TOPLON® |
|
TOPLON® |
|
see on |
|
||
|
750- |
|
|
IF |
|
|
PRIO |
|
page |
|
|
550 |
2 |
Channel Analog Output (0-10 V DC) |
X |
|
|
X |
|
155 |
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
552 |
2 |
Channel Analog Output (0-20mA) |
X |
|
|
X |
|
159 |
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
554 |
2 |
Channel Analog Output (4-20mA) |
X |
|
|
X |
|
159 |
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
556 |
2 |
Channel Analog Output (± 10 V DC) |
- |
|
|
X |
|
155 |
|
|
|
|
|
|
|
|
||||
|
Specialty modules |
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|||
|
Item- |
|
|
|
supported by |
|
|
|
||
|
No: |
notation |
TOPLON® |
|
TOPLON® |
|
see on |
|
||
|
750- |
|
|
IF |
|
|
PRIO |
|
page |
|
|
404 |
Up/Down Counter |
- |
|
|
- |
|
163 |
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
511 |
2 |
Channel Digital Output (0.1 A, 24 V DC) Pulsewidth |
- |
|
|
- |
|
178 |
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
630 |
SSI transmitter interface 24Bit 125 kHz |
- |
|
|
- |
|
184 |
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
631 |
Incremental encoder interface |
- |
|
|
- |
|
187 |
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
650 |
RS232 C9600, n, 8, 1 |
- |
|
|
- |
|
192 |
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
651 |
TTY-, 20 mA Current Loop |
- |
|
|
- |
|
198 |
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
653 |
RS485 Interface |
- |
|
|
- |
|
202 |
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
654 |
Data exchange module |
- |
|
|
- |
|
208 |
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Modular I/O System
LONWORKS®
66 • I/O modules Review
Supply modules
Item- |
|
|
supported by |
|
|
No: |
notation |
TOPLON® |
TOPLON® |
see on |
|
750- |
|
IF |
|
PRIO |
page |
601 |
Supply modules with fuse holder |
O |
|
O |
215 |
|
(24 V DC) |
|
|
||
602 |
Supply modules, passive (24 V DC) |
O |
|
O |
216 |
|
|
|
|||
|
|
|
|
|
|
609 |
Supply modules with fuse holder (230 V AC) |
O |
|
O |
215 |
|
|
|
|||
|
|
|
|
|
|
610 |
Supply modules with fuse holder, with diagn. (24 V DC) |
- |
|
X |
217 |
|
|
|
|||
|
|
|
|
|
|
611 |
Supply modules with fuse holder, with diagn. (230 V AC) |
- |
|
X |
217 |
612 |
Supply modules, passive (230 V AC/DC) |
O |
|
O |
219 |
|
|
|
|||
|
|
|
|
|
|
613 |
Supply modules with DC-DC Converter |
O |
|
O |
220 |
|
(24 V DC) |
|
|
||
615 |
Supply modules with fuse holder (120 V AC) |
O |
|
O |
215 |
|
|
|
|||
|
|
|
|
|
|
Potential multiplication module |
|
|
|
|
|
|
|
|
|
|
|
Item- |
|
|
supported by |
|
|
No: |
notation |
TOPLON® |
TOPLON® |
see on |
|
750- |
|
IF |
|
PRIO |
page |
614 |
Potential multiplication modules |
O |
|
O |
222 |
|
(24 V-230 V AC/DC) |
|
|
||
Binary spacer module |
|
|
|
|
|
|
|
|
|
|
|
Item- |
|
|
supported by |
|
|
No: |
notation |
TOPLON® |
TOPLON® |
see on |
|
750- |
|
IF |
|
PRIO |
page |
622 |
Binary spacer modules with power supply |
- |
|
- |
223 |
|
|
|
|||
|
|
|
|
|
|
Separation module / end module |
|
|
|
|
|
|
|
|
|
|
|
Item- |
|
|
supported by |
|
|
No: |
notation |
TOPLON® |
TOPLON® |
see on |
|
750- |
|
IF |
|
PRIO |
page |
616 |
Separation modules |
O |
|
O |
222 |
|
|
|
|||
|
|
|
|
|
|
600 |
End modules |
O |
|
O |
228 |
|
|
|
|||
|
|
|
|
|
|
Modular I/O System
LONWORKS®
