- •Table of Contents
- •Important comments
- •Legal disclaimers
- •Copyright
- •Personnel qualification
- •Intended use
- •Scope
- •Symbols
- •WAGO-I/O-SYSTEM 750
- •System Description
- •General
- •Coupler/Controller (1)
- •I/O Modules (2)
- •End Module (3)
- •Installation
- •Safety notes
- •Mechanical Installation
- •Electrical Installation
- •Wire Connection
- •Change fuse
- •Power supply
- •System supply voltage
- •Supply Voltage Field Side
- •Manufacturing Number
- •Technical Data
- •Fieldbus coupler/controller
- •Fieldbus coupler 750-319
- •Description
- •Software for the coupler
- •Hardware
- •View
- •Device supply
- •Fieldbus connection
- •Display elements
- •Configuration interface
- •Hardware address
- •Operating system
- •Data exchange
- •Starting-up LON fieldbus nodes
- •LED display
- •Blink code
- •Fieldbus status
- •Node status
- •Fault message via the blink code of the I/O LED
- •Supply voltage status
- •Fault behavior
- •Fieldbus failure
- •Internal bus fault
- •Technical Data
- •Fieldbus controller 750-819
- •Description
- •Software for the controller
- •Hardware
- •View
- •Device supply
- •Fieldbus connection
- •Display elements
- •Configuration and programming interface
- •Operating mode switch
- •Hardware address
- •Operating system
- •Start-up
- •PLC cycle
- •Process image
- •Data exchange
- •Memory areas
- •Addressing
- •Addressing the I/O modules
- •Addressing the PFC variables
- •Addressing the configuration variables
- •Starting-up LON fieldbus nodes
- •Programming the PFC with WAGO-I/O-PRO 32
- •LON library elements for WAGO-I/O-PRO 32
- •IEC 61131-3 Program transfer
- •Transmission via the serial interface
- •Transmission via the fieldbus
- •LED display
- •Blink code
- •Fieldbus status
- •Node status
- •Fault message via the blink code of the I/O LED
- •Supply voltage status
- •Fault behavior
- •Fieldbus failure
- •Internal bus fault
- •Technical Data
- •I/O modules
- •Digital Inputs
- •Digital Outputs
- •Analog Inputs
- •Analog Outputs
- •Speciality modules
- •Supply modules
- •Potential multiplication module
- •Binary spacer modules
- •Separation module/ end module
- •General Safty Information!
- •Information on the network architecture
- •Transmision media
- •Topology
- •Transceiver
- •Recommended bus and cable lengths
- •Bus shaped wiring
- •Free Wiring
- •Cable specifications
- •Network installation
- •Addressing
- •Configuration
- •Binding
- •Network communication
- •Data exchange via network variables
- •Standard types of network variables
- •Protocol
- •Channel access method
- •Application in Explosive Environments
- •Foreword
- •Protective measures
- •Classification meeting CENELEC and IEC
- •Divisions
- •Explosion protection group
- •Unit categories
- •Temperature classes
- •Types of ignition protection
- •Classifications meeting the NEC 500
- •Divisions
- •Explosion protection groups
- •Temperature classes
- •Identification
- •For Europe
- •For America
- •Installation regulations
- •Glossary
- •Literature list
- •Index
52 • Fieldbus coupler/controller Fieldbus controller 750-819
3.2.8.2 IEC 61131-3 Program transfer
Program transfer from the PC to the controller following programming of the desired IEC 61131 application can be made in two different ways:
•via the serial interface or
•via the fieldbus.
3.2.8.2.1Transmission via the serial interface
Use the WAGO communication cable to produce a physical connection via the serial interface. This is contained in the scope of delivery of the programming tool IEC 1131-3, order No.: 759-332/000-002, or can be purchased as an accessory under order No.: 750-920.
Connect the COMX port of your PC with the communication interface of your controller via the WAGO communication cable.
A communication driver is required for serial data transmission. In WAGO- I/O-PRO 32, this driver and its parameters are entered in the "Communication parameters" dialog.
More information
i Please find more information on the installation of the communication driver and the detailed description of software handling in the manual WAGO-I/O-PRO 32 (order no.: 759-122 / 000-001).
1.Start the WAGO-I/O-PRO 32 software via ’Start/Programs’ or by double clicking on the WAGO-I/O-PRO-32 symbol on your desk top.
2.In the "Online" menu click on the "Communication parameters" menu point.
The dialog "Communication parameters" opens. The basic setting of this dialog has not yet any entries.
3.In the selection window mark the desired driver on the right-hand dialog side (i.e. "Serial (RS232)", to configure the serial connection between PC and the controller).
4.In the center window of the dialog, the following entries have to appear:
- Parity: |
Even |
- Stop bits: |
1 |
If necessary, change the entries accordingly.
You can now commence testing the controller.
Modular I/O System
LONWORKS®
Fieldbus coupler/controller |
• 53 |
Fieldbus controller 750-819 |
|
|
|
Note
To be able to access the controller, ensure that the operating mode switch of the controller is set to the center or the top position.
5.Under "Online" click on the "Log-on" menu point to log into the controller. (The WAGO-I/O-PRO 32 server is active during online operation. The communication parameters cannot be polled.)
6.If there is not a program in the controller, a window appears asking whether or not the program is to be loaded.
Confirm with "Yes".
Subsequently the current program will be loaded.
7.As soon as the program is loaded, you can start program via the "Online" menu, menu point "Start".
At the right-hand end of the status bar, the system signals "ONLINE RUNNING"." gemeldet.
8.To terminate the online operation, return via the "Online" menu and click on the "Log-off" menu point.
3.2.8.2.2Transmission via the fieldbus
The field bus cable is the physical connection between the PC and the controller.
In TOPLON® PRIO the transfer of the IEC 61131 programm take place via Menue "WAGO-I/O-PRO\Download IEC 61131 Application".
Fig. 3-8: Main view TOPLON® PRIO |
g012377e |
Modular I/O System
LONWORKS®
54 • Fieldbus coupler/controller Fieldbus controller 750-819
1.Start the Plug-In TOPLON® PRIO in the NMT (Networkmanagement Tool Software).
2.Click on the menue "WAGO-I/O-PRO"/"Download IEC 61131 Applikation" in the main view of TOPLON® PRIO.
A dialog window "Selection of a IEC 61131 Application" appears.
Fig. 3-9: Dialog window for selection of an IEC 61131 Application |
p9123A2e |
3.Select the desired IEC 61131 application with the extension *.hex and click on the button "ÖFFNEN".
The selection window is closed and the PLC-program, respectively the PLC-programm modifications are adopt into the controller.
Modular I/O System
LONWORKS®