- •Table of Contents
- •Important comments
- •Legal disclaimers
- •Copyright
- •Personnel qualification
- •Intended use
- •Scope
- •Symbols
- •WAGO-I/O-SYSTEM 750
- •System Description
- •General
- •Coupler/Controller (1)
- •I/O Modules (2)
- •End Module (3)
- •Installation
- •Safety notes
- •Mechanical Installation
- •Electrical Installation
- •Wire Connection
- •Change fuse
- •Power supply
- •System supply voltage
- •Supply Voltage Field Side
- •Manufacturing Number
- •Technical Data
- •Fieldbus coupler/controller
- •Fieldbus coupler 750-319
- •Description
- •Software for the coupler
- •Hardware
- •View
- •Device supply
- •Fieldbus connection
- •Display elements
- •Configuration interface
- •Hardware address
- •Operating system
- •Data exchange
- •Starting-up LON fieldbus nodes
- •LED display
- •Blink code
- •Fieldbus status
- •Node status
- •Fault message via the blink code of the I/O LED
- •Supply voltage status
- •Fault behavior
- •Fieldbus failure
- •Internal bus fault
- •Technical Data
- •Fieldbus controller 750-819
- •Description
- •Software for the controller
- •Hardware
- •View
- •Device supply
- •Fieldbus connection
- •Display elements
- •Configuration and programming interface
- •Operating mode switch
- •Hardware address
- •Operating system
- •Start-up
- •PLC cycle
- •Process image
- •Data exchange
- •Memory areas
- •Addressing
- •Addressing the I/O modules
- •Addressing the PFC variables
- •Addressing the configuration variables
- •Starting-up LON fieldbus nodes
- •Programming the PFC with WAGO-I/O-PRO 32
- •LON library elements for WAGO-I/O-PRO 32
- •IEC 61131-3 Program transfer
- •Transmission via the serial interface
- •Transmission via the fieldbus
- •LED display
- •Blink code
- •Fieldbus status
- •Node status
- •Fault message via the blink code of the I/O LED
- •Supply voltage status
- •Fault behavior
- •Fieldbus failure
- •Internal bus fault
- •Technical Data
- •I/O modules
- •Digital Inputs
- •Digital Outputs
- •Analog Inputs
- •Analog Outputs
- •Speciality modules
- •Supply modules
- •Potential multiplication module
- •Binary spacer modules
- •Separation module/ end module
- •General Safty Information!
- •Information on the network architecture
- •Transmision media
- •Topology
- •Transceiver
- •Recommended bus and cable lengths
- •Bus shaped wiring
- •Free Wiring
- •Cable specifications
- •Network installation
- •Addressing
- •Configuration
- •Binding
- •Network communication
- •Data exchange via network variables
- •Standard types of network variables
- •Protocol
- •Channel access method
- •Application in Explosive Environments
- •Foreword
- •Protective measures
- •Classification meeting CENELEC and IEC
- •Divisions
- •Explosion protection group
- •Unit categories
- •Temperature classes
- •Types of ignition protection
- •Classifications meeting the NEC 500
- •Divisions
- •Explosion protection groups
- •Temperature classes
- •Identification
- •For Europe
- •For America
- •Installation regulations
- •Glossary
- •Literature list
- •Index
Fieldbus coupler/controller |
• 49 |
Fieldbus controller 750-819 |
|
|
|
3.2.7 Starting-up LON fieldbus nodes
|
The general procedure for starting up a WAGO LON fieldbus node with the |
||
|
fieldbus controller 750-819 is described step-by-step for TOPLON® PRIO in |
||
|
the brief instructions WAGO TOPLON® (Quickstart, Item no.: 759-123/000- |
||
|
002 part 7). |
||
|
These should form a guideline for further projects. |
||
|
|
|
|
i |
|
More information |
|
|
The brief instructions WAGO TOPLON® (Quickstart, |
||
|
|
Item no.: 759-123/000-002 part 7) can be found in the Internet under: |
|
|
|
http://www.wagotoplon.com/html/eng/service/manual/index.htm |
|
|
|
|
|
|
|
Attention |
|
|
|
This description is given as an example and is limited to the execution of a |
|
|
|
local start-up of an individual LON fieldbus node with TOPLON® PRIO. |
|
3.2.8 Programming the PFC with WAGO-I/O-PRO 32
Due to the IEC 61131 programming of the LON fieldbus controller 750-819 you have the option to use the functionality of a PLC.
An application program according to IEC 61131-3 is created using the programming tool WAGO-I/O-PRO 32 (order No.: 759-332/000-002).
This manual, however, does not include a description of how to program with WAGO-I/O-PRO 32. In contrast, the following chapters are to describe the special modules for WAGO-I/O-PRO 32 for you to utilize explicitly for programming the LON fieldbus controller.
The description also explains transmitting the IEC 61131-3 program into the controller and loading a suitable communication driver.
More information
i For a detailed description of how to use the software, please refer to the WAGO-I/O-PRO 32 manual (order No.: 759-122 / 000-002).
Modular I/O System
LONWORKS®
50 • Fieldbus coupler/controller Fieldbus controller 750-819
3.2.8.1 LON library elements for WAGO-I/O-PRO 32
i
i
You are offered various libraries for different IEC 61131-3 programming applications in WAGO-I/O-PRO 32. They contain modules for universal use and can, thereby, facilitate and speed up the creation of your program. As standard, the library 'standard.lib' is available to you.
The library described in the following is specifically intended for LON projects in the building automation with WAGO-I/O-PRO 32.
These libraries include functional modules for building automation and they are loaded on the WAGO-I/O-PRO CD.
Having integrated this library, you have access to its POUs, data types and global variables which can be used in the same manner as those defined by yourself.
More information
For a detailed description of the POUs and the software operation, please refer to the WAGO-I/O-PRO 32 manual (order No.: 759-122 / 000-002).
More information
The function blocks of the LON libraries for WAGO-I/O-PRO 32 are being constantly upgraded. You can download the latest upgrade of the libraries from the Internet at: http://www.wagotoplon.com/html/ger/products/wago_toplon/software/applicati ons/index.htm.
Modular I/O System
LONWORKS®
Fieldbus coupler/controller |
• 51 |
Fieldbus controller 750-819 |
|
|
|
This page has been intentionally left blank, so that you can file the printed documentation of the last upgrade of the WAGO-I/O-PRO function blocks.
Modular I/O System
LONWORKS®