- •Table of Contents
- •Important comments
- •Legal disclaimers
- •Copyright
- •Personnel qualification
- •Intended use
- •Scope
- •Symbols
- •WAGO-I/O-SYSTEM 750
- •System Description
- •General
- •Coupler/Controller (1)
- •I/O Modules (2)
- •End Module (3)
- •Installation
- •Safety notes
- •Mechanical Installation
- •Electrical Installation
- •Wire Connection
- •Change fuse
- •Power supply
- •System supply voltage
- •Supply Voltage Field Side
- •Manufacturing Number
- •Technical Data
- •Fieldbus coupler/controller
- •Fieldbus coupler 750-319
- •Description
- •Software for the coupler
- •Hardware
- •View
- •Device supply
- •Fieldbus connection
- •Display elements
- •Configuration interface
- •Hardware address
- •Operating system
- •Data exchange
- •Starting-up LON fieldbus nodes
- •LED display
- •Blink code
- •Fieldbus status
- •Node status
- •Fault message via the blink code of the I/O LED
- •Supply voltage status
- •Fault behavior
- •Fieldbus failure
- •Internal bus fault
- •Technical Data
- •Fieldbus controller 750-819
- •Description
- •Software for the controller
- •Hardware
- •View
- •Device supply
- •Fieldbus connection
- •Display elements
- •Configuration and programming interface
- •Operating mode switch
- •Hardware address
- •Operating system
- •Start-up
- •PLC cycle
- •Process image
- •Data exchange
- •Memory areas
- •Addressing
- •Addressing the I/O modules
- •Addressing the PFC variables
- •Addressing the configuration variables
- •Starting-up LON fieldbus nodes
- •Programming the PFC with WAGO-I/O-PRO 32
- •LON library elements for WAGO-I/O-PRO 32
- •IEC 61131-3 Program transfer
- •Transmission via the serial interface
- •Transmission via the fieldbus
- •LED display
- •Blink code
- •Fieldbus status
- •Node status
- •Fault message via the blink code of the I/O LED
- •Supply voltage status
- •Fault behavior
- •Fieldbus failure
- •Internal bus fault
- •Technical Data
- •I/O modules
- •Digital Inputs
- •Digital Outputs
- •Analog Inputs
- •Analog Outputs
- •Speciality modules
- •Supply modules
- •Potential multiplication module
- •Binary spacer modules
- •Separation module/ end module
- •General Safty Information!
- •Information on the network architecture
- •Transmision media
- •Topology
- •Transceiver
- •Recommended bus and cable lengths
- •Bus shaped wiring
- •Free Wiring
- •Cable specifications
- •Network installation
- •Addressing
- •Configuration
- •Binding
- •Network communication
- •Data exchange via network variables
- •Standard types of network variables
- •Protocol
- •Channel access method
- •Application in Explosive Environments
- •Foreword
- •Protective measures
- •Classification meeting CENELEC and IEC
- •Divisions
- •Explosion protection group
- •Unit categories
- •Temperature classes
- •Types of ignition protection
- •Classifications meeting the NEC 500
- •Divisions
- •Explosion protection groups
- •Temperature classes
- •Identification
- •For Europe
- •For America
- •Installation regulations
- •Glossary
- •Literature list
- •Index
48 • |
Fieldbus coupler/controller |
|
|
|
|
|
|
Fieldbus controller 750-819 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
PFC input variables |
|
PFC output variables |
|
|
|
|
(word 256 to 512) |
|
(word 256 to 512) |
|
|
|
|
20 x double word |
|
20 x |
double word |
|
|
|
|
|
|
|
|
|
|
100 x word |
|
100 x |
word |
|
|
|
|
|
|
|
|
|
|
100 x Int |
|
100 x |
Int |
|
|
|
|
|
|
|
|
|
|
100 x byte |
|
100 x |
byte |
|
|
|
|
|
|
|
|
|
|
496 x bit |
|
496 x bit |
|
|
|
|
|
|
|
|
|
Tab. 3-4: Maximum number of variables in the template file Template_750-819.pro
The following address ranges for input and output memory space (word 256 to 512) are preset within the template:
PFC input variables |
|
|
PFC output variables |
|
(word 256 to 512) |
|
|
(word 256 to 512) |
|
2 x double word %ID138 - %ID139 |
|
2 x double word %ID138 - %ID139 |
||
|
|
|
|
|
10 x word |
%IW320 - %IW329 |
|
10 x word |
%IW320 - %IW329 |
|
|
|
|
|
10 x Int |
%IW330 - %IW339 |
|
10 x Int |
%IW330 - %IW339 |
|
|
|
|
|
15 x byte |
%IB845 - %IB859 |
|
15 x byte |
%IB845 - %IB859 |
|
|
|
|
|
20 x bit |
%IX475.0-%IX476.3 |
|
20 x bit |
%IX475.0-%IX476.3 |
|
|
|
|
|
Tab. 3-5: Presetting addresses in the template file Template_750-819.pro
This template can be upgraded and modified at any time.
Once the IEC 61131 application programmed in WAGO-I/O-PRO 32 has been compiled, all declared variables can be stored in a Symbol-file (SYM-file). After downloading the SYM-file in the WAGO TOPLON® PRIO plug-in, all variables are ready to be linked with network variables.
Note
Given that all variables are automatically imported from the template into the standard WAGO TOPLON® PRIO application, unused variables should not be deleted from the template in order to achieve a better clarity.
3.2.6.2.3 Addressing the configuration variables
Variables used for external configuration via the LON fieldbus are absolute addressed in double flag words. The address range begins with %MD1792 and has a capacity of 128 variables.
After downloading the SYM-file into WAGO TOPLON® PRIO, all defined configuration variables are ready to be linked with CPs (Configuration Properties) just like the PFC variables.
Modular I/O System
LONWORKS®