Добавил:
course-as.ru Авшаров Евгений Михайлович, ejen@course-as.ru Инвестор и Технический директор ООО 'КУРС-АС1', Москва, http://www.course-as.ru, Все наиболее важное обо мне:http://www.course-as.ru/Avsharov.html Опубликованный материал нарушает ваши авторские права? Сообщите нам.
Вуз: Предмет: Файл:

PS-2020a / part16

.pdf
Скачиваний:
31
Добавлен:
01.06.2020
Размер:
45.31 Mб
Скачать

DICOM PS3.16 2020a - Content Mapping Resource​

Page 391​

Row 3​ The reason that this value was selected as the preferred value for the measured concept.​

The parent template may allow TID 5301 “Pre-coordinated Echo Measurement” to be included multiple times with the​ same Measurement Concept Name, for example to allow multiple samples of the measurement.​

A given Measurement Concept Name might appear only once in the instance, in which case this this row may or may​ not be present. A given Measurement Concept Name may appear multiple times, however this row shall not be present​ for more than one value of a given measured concept. E.g. multiple measurements of (11706-9, LN, "Aortic Valve Peak​ Systolic Flow") may be present, but only one may be selected as preferred.​

Row 4​ The method used to derive this measurement value from multiple samples of the Measurement Concept Name.​

If Row 3 is not present, then this measurement value is simply a single sample of the Measurement Concept Name.​

Note​

1.​A measurement value that is a mean value of other samples and was also selected as the preferred value​ because it is the mean will have both Row 2 and Row 3 present.​

2.​This row is not used to record whether the measurement value is a direct measurement vs a measurement​ calculated from an equation. Such information is recorded in Row 7.​

Row 8​ The finding site reflects the anatomical location where the measurement is taken.​

CID 12305 “Basic Echo Anatomic Sites” contains the codes which proved to be sufficient for mapping the full set of ASE​ standard measurements. It is recommended to use these locations unless a more detailed location is truly necessary.​

Row 9​ The finding observation type indicates the type of observation made at the finding site to produce the measurement.​

In many cases, for example Aortic Root Diameter, the structure of the finding site is being observed.​

In other cases, for example Mitral Valve Regurgitant Flow Peak Velocity, the finding site is the mitral valve, the​ hemodynamic flow (not the valve structure) is being observed, the measured property is the peak velocity, and the flow​ direction is retrograde.​

Row 17​ The pre-coordinated code for the measurement that has been used as the denominator of this measurement. Only​ applies to measurements of type Indexed, Ratio or Fractional Change.​

The measurement referenced as the Measurement Divisor shall be present in the instance in which it is used.​

When Row 17 is present, any values in Rows 5-6, 8-16 shall reflect the numerator of the measurement rather than the​ Index, Ratio or Fractional Change as a whole. The rest of the rows, including the pre-coordinated measurement value,​ the pre-coordinated measurement code, the units and the short label, reflect the Index, Ratio or Fractional Change as​ a whole. E.g. in the case of an Indexed measurement, the value recorded in Row 1 has already been divided by the​ Index referenced in Row 17, and the Units in Row 1 match the indexed value, not the numerator Property described in​ Row 10.​

For a measurement of type Indexed, the numerator is divided by the Measurement Divisor.​

For a measurement of type Ratio, the numerator is divided by the Measurement Divisor and is unitless.​

For a measurement of type Fractional Change, the numerator is first subtracted from the Measurement Divisor and the​ result divided by the Measurement Divisor (i.e., (Divisor - Numerator) / Divisor ).​

Row 18​ This may be used to label the measurement value when space is limited on the screen or report page. E.g. a Short Label​ of "LVIDD" might be provided for a measurement of the left ventricle internal diameter at end diastole.​

Note​

Short Labels are not standardized and may omit details of the measurement, thus it is not recommended to​ use them for purposes such as matching.​

- Standard -​

Page 392​

DICOM PS3.16 2020a - Content Mapping Resource​

TID 5303 Adhoc Measurement​

This Template codes numeric echo measurements where most of the details about the nature of the measurement are not commu-​ nicated. The measurement is identified in terms of the property measured, such as Length, Diameter, Area, Velocity etc. and some​ measurement context may established by reference to spatial coordinates on an image or a waveform. A displayable label is included​ but there is no managed code identifying the measurement.​

The template is intended to be used to include adhoc, one-time measurements whose need is determined during imaging exam or​ reviewing session.​

Measurementsthataretakeninanadhocfashionbutareselectedfromthesetofpre-coordinatedorpost-coordinatedmeasurements​ that are configured on the Ultrasound System should be coded using TID 5301 “Pre-coordinated Echo Measurement” or TID 5302​ “Post-coordinated Echo Measurement”.​

 

 

 

 

Table TID 5303. Parameters​

 

 

 

Parameter Name​

 

 

Parameter Usage​

$Property​

 

 

Property being measured​

 

Type:​

 

Non-Extensible​

 

 

 

Order:​

 

Significant​

 

 

 

Root:​

 

No​

 

 

 

 

 

 

 

Table TID 5303. Adhoc Measurement​

 

 

NL​

Rel with​

VT​

Concept Name​

VM​

Req​

Condition​ Value Set Constraint​

 

 

Parent​

 

 

 

Type​

 

1​

 

 

NUM​

$Property​

1​

M​

 

2​

>​

 

INCLUDE​

DTID320“ImageorSpatial​ 1-n​

U​

$Purpose = EV (121112,​

 

 

 

 

Coordinates”​

 

 

DCM, "Source of​

 

 

 

 

 

 

 

measurement")​

3​

>​

 

INCLUDE​

DTID 321 “Waveform or​

1-n​

U​

$Purpose = EV (121112,​

 

 

 

 

Temporal Coordinates”​

 

 

DCM, "Source of​

 

 

 

 

 

 

 

measurement")​

4​

>​

HAS​

TEXT​

EV (125309, DCM, "Short​

1​

M​

 

 

 

PROPERTIES​

Label")​

 

 

 

Content Item Descriptions​

Row 4​ This may be used to label the measurement value when space is limited on the screen or report page. E.g. a Short​ Label of "LVIDD" might be provided for a measurement of the left ventricle internal diameter at end diastole.​

Note​

Short Labels are not standardized and may omit details of the measurement, thus it is not recommended​ to use them for purposes such as matching.​

Implantation Plan SR Document Templates ​

The Templates that comprise the Implantation Plan SR Document IOD are interconnected as in Figure A-11.​

- Standard -​

DICOM PS3.16 2020a - Content Mapping Resource​

Page 393​

TID 7000

 

TID 1001

 

Implantation Plan

 

Observer

 

Root

 

Context

 

TID 351

Previous Reports

TID 7001

Related Implantation

Reports

TID 1204

Language of

Content Item and

Descendants

Figure A-11. Implantation Plan SR Document IOD Template Structure​

TID 7000 Implantation Plan​

This Template contains all the necessary information to position an Implant Assembly and its Components in a patient. Therefore, all​ the Components that comprise an Implant Assembly are listed. If the Implant Assembly consists of more than one Component, the​ relation between the Components will be described as well. It is also possible to describe the registration between the Components​ and the patient and between the Components themselves.​

To reference the Components within this document the Implantation Plan Component ID is used.​

The Component Connection links two Implantation Plan Components in a commutative way. This means that for each link between​ A and B only one Component Connection has to be defined and not two for A-B and B-A.​

The terminology used is defined by illustration using the example in Figure A-12.​

- Standard -​

Page 394​

DICOM PS3.16 2020a - Content Mapping Resource​

Assembly

Component Connection with Degree of Freedom

(Rotation)

Component Connection

without Degree of Freedom

Different Component types

Mating Feature

Mating Feature

Mating Feature Set

Component

(one Implant Template contains one Component)

 

Figure A-12. Implant Assembly and Components Terminology​

Type:​

Extensible​

Order:​

Significant​

Root:​

Yes​

 

Table TID 7000. Implantation Plan​

 

NL​

Rel with​

VT​

Concept Name​

VM​

Req​ Condition​

Value Set​

 

 

Parent​

 

 

 

Type​

Constraint​

1​

 

 

CONTAINER​EV (112345, DCM,​

1​

M​

Root node​

 

 

 

 

"Implantation Plan")​

 

 

 

2​

>​

HAS​

INCLUDE​

DTID 1204 “Language of​

1​

U​

 

 

 

CONCEPT​

 

Content Item and​

 

 

 

 

 

MOD​

 

Descendants”​

 

 

 

3​

>​

HAS OBS​

INCLUDE​

DTID 1001 “Observation​

1​

M​

 

 

 

CONTEXT​

 

Context”​

 

 

 

4​

>​

CONTAINS​

INCLUDE​

DTID 351 “Previous Reports”​

1​ MC​ IFF previous​Shall only reference​

 

 

 

 

 

 

Implantation​ other Implantation​

 

 

 

 

 

 

Plan​

Plan Documents​

 

 

 

 

 

 

Documents​

 

 

 

 

 

 

 

exist​

 

- Standard -​

 

 

 

DICOM PS3.16 2020a - Content Mapping Resource​

Page 395​

 

NL​

Rel with​

VT​

Concept Name​

VM​

Req​ Condition​

Value Set​

 

 

Parent​

 

 

 

Type​

Constraint​

5​

>​

CONTAINS​

INCLUDE​

DTID 7001 “Related​

1​

MC​ IFF related​

Shall only reference​

 

 

 

 

Implantation Reports”​

 

Implantation​ other Implantation​

 

 

 

 

 

 

Plan​

Plan Documents​

 

 

 

 

 

 

Documents​

 

 

 

 

 

 

 

exist that are​

 

 

 

 

 

 

notreferenced​

 

 

 

 

 

 

by row 4​

 

6​

>​

CONTAINS​

CONTAINER​EV (112360, DCM, "Implant​

1​

M​

 

 

 

 

 

Component List")​

 

 

 

7​

>>​

CONTAINS​

COMPOSITE​EV (112366, DCM, "Implant​

1​

U​

References an​

 

 

 

 

Assembly Template")​

 

 

Implant Assembly​

 

 

 

 

 

 

 

Template SOP​

 

 

 

 

 

 

 

Instance​

8​

>>​

CONTAINS​

CONTAINER​EV (112346, DCM, "Selected​1-n​

M​

 

 

 

 

 

Implant Component")​

 

 

 

9​

>>>​

CONTAINS​

TEXT​

EV (112347, DCM,​

1​

M​

 

 

 

 

 

"Component ID")​

 

 

 

10​

>>>​

CONTAINS​

CODE​

EV (112370, DCM,​

1​

MC​ IFF Row 8​

DCID 7306 “Human​

 

 

 

 

"Component Type")​

 

containsmore​HipImplantPlanning​

 

 

 

 

 

 

thanoneitem.​Landmarks”​

11​

>>>​

CONTAINS​

COMPOSITE​

1​

M​

References an​

 

 

 

 

 

 

 

Implant Template​

 

 

 

 

 

 

 

Storage SOP​

 

 

 

 

 

 

 

Instance​

12​

>>>​

CONTAINS​

UIDREF​

EV(112227,DCM,"FrameOf​ 1​

M​

 

 

 

 

 

Reference UID")​

 

 

 

13​

>>>​

CONTAINS​

COMPOSITE​EV (112371, DCM,​

1​

M​

References an​

 

 

 

 

"Manufacturer Implant​

 

 

Implant Template​

 

 

 

 

Template")​

 

 

Storage SOP​

 

 

 

 

 

 

 

Instance​

14​

>​

CONTAINS​

CONTAINER​EV (112355, DCM,​

1-n​

U​

 

 

 

 

 

"Assembly")​

 

 

 

15​

>>​

CONTAINS​

CONTAINER​EV (112350, DCM,​

1-n​

M​

 

 

 

 

 

"Component Connection")​

 

 

 

16​

>>>​

CONTAINS​

CONTAINER​EV (112374, DCM,​

2​

M​

 

 

 

 

 

"ConnectedImplantationPlan​

 

 

 

 

 

 

 

Component")​

 

 

 

17​

>>>>​

CONTAINS​

TEXT​

EV (112347, DCM,​

1​

M​

Defined in the​

 

 

 

 

"Component ID")​

 

 

Implant Component​

 

 

 

 

 

 

 

List CONTAINER​

18​

>>>>​

CONTAINS​

TEXT​

EV (112351, DCM, "Mating​

1​

M​

OnlyoneComponent​

 

 

 

 

Feature Set ID")​

 

 

Connection per​

 

 

 

 

 

 

 

Mating Feature Set​

 

 

 

 

 

 

 

is allowed​

19​

>>>>​

CONTAINS​

TEXT​

EV (112352, DCM, "Mating​

1​

M​

 

 

 

 

 

Feature ID")​

 

 

 

20​

>>>>​

CONTAINS​

CONTAINER​EV (112362, DCM, "Degrees​ 1-n​

U​

 

 

 

 

 

of Freedom Specification")​

 

 

 

21​

>>>>>​ CONTAINS​

TEXT​

EV (112363, DCM, "Degree​

1​

M​

 

 

 

 

 

of Freedom ID")​

 

 

 

- Standard -​

Page 396​

 

DICOM PS3.16 2020a - Content Mapping Resource​

 

 

NL​

Rel with​

VT​

Concept Name​

VM​

Req​ Condition​

Value Set​

 

 

Parent​

 

 

 

Type​

Constraint​

22​

>>>>>​ CONTAINS​

NUM​

EV (112376, DCM, "Degree​

1​

MC​ IFF Row 23,​ UNITS = EV (mm,​

 

 

 

 

of Freedom Exact​

 

24,25,26and​UCUM, "mm")​

 

 

 

 

Translational Value")​

 

27 are absent​

23​

>>>>>​ CONTAINS​

NUM​

EV (112377, DCM, "Degree​

1​

MC​ IFF row 22,​ UNITS = EV (mm,​

 

 

 

 

of Freedom Minimum​

 

25,26,and27​UCUM, "mm")​

 

 

 

 

Translational Value")​

 

are absent​

 

24​

>>>>>​ CONTAINS​

NUM​

EV (112378, DCM, "Degree​

1​

MC​ IFF row 22,​ UNITS = EV (mm,​

 

 

 

 

of Freedom Maximum​

 

25,26,and27​UCUM, "mm")​

 

 

 

 

Translational Value")​

 

are absent​

 

25​

>>>>>​ CONTAINS​

NUM​

EV (112379, DCM, "Degree​

1​

MC​ IFF row 22,​ UNITS = EV (deg,​

 

 

 

 

of Freedom Exact Rotational​

 

23,24,26and​UCUM, "degree")​

 

 

 

 

Value")​

 

27 are absent​

26​

>>>>>​ CONTAINS​

NUM​

EV (112380, DCM, "Degree​

1​

MC​ IFF row 22,​ UNITS = EV (deg,​

 

 

 

 

of Freedom Minimum​

 

23, 24 and 25​UCUM, "degree")​

 

 

 

 

Rotational Value")​

 

are absent​

 

27​

>>>>>​ CONTAINS​

NUM​

EV (112381, DCM, "Degree​

1​

MC​ IFF row 22,​ UNITS = EV (deg,​

 

 

 

 

of Freedom Maximum​

 

23, 24 and 25​UCUM, "degree")​

 

 

 

 

Rotational Value")​

 

are absent​

 

28​

>​

CONTAINS​

CONTAINER​EV (112358, DCM,​

1​

U​

 

 

 

 

 

"Information used for​

 

 

 

 

 

 

 

planning")​

 

 

 

29​

>>​

CONTAINS​

CODE​

EV (112375, DCM, "Planning​ 1​

U​

BCID7320“Planning​

 

 

 

 

Method")​

 

 

Methods”​

30​

>>​

CONTAINS​

IMAGE​

EV (112354, DCM, "Patient​

1-n​

U​

 

 

 

 

 

Image")​

 

 

 

31​

>>>​

HAS​

NUM​

EV (111026, DCM,​

1​

M​

UNITS = EV​

 

 

PROPERTIES​

"Horizontal Pixel Spacing")​

 

 

(mm/{pixel}, UCUM,​

 

 

 

 

 

 

 

"mm/pixel")​

32​

>>>​

HAS​

NUM​

EV (111066, DCM, "Vertical​

1​

M​

UNITS = EV​

 

 

PROPERTIES​

Pixel Spacing")​

 

 

(mm/{pixel}, UCUM,​

 

 

 

 

 

 

 

"mm/pixel")​

33​

>>​

CONTAINS​

COMPOSITE​EV (112361, DCM, "Patient​

1-n​

U​

References SOP​

 

 

 

 

Data Used During Planning")​

 

 

Instances except​

 

 

 

 

 

 

 

Images​

34​

>>>​

HAS​

UIDREF​

EV (112356, DCM, "User​

1-n​

MC​ IFF row 33​

 

 

 

PROPERTIES​

Selected Fiducial")​

 

references a​

 

 

 

 

 

 

 

Fiducial SOP​

 

 

 

 

 

 

Instance​

 

35​

>>>>​

HAS​

TEXT​

EV (112369, DCM, "Fiducial​

1​

U​

 

 

 

CONCEPT​

 

Intent")​

 

 

 

 

 

MOD​

 

 

 

 

 

36​

>​

CONTAINS​

CONTAINER​EV (112367, DCM, "Planning​ 1​

U​

 

 

 

 

 

Information for Intraoperative​

 

 

 

 

 

 

 

Usage")​

 

 

 

37​

>>​

CONTAINS​

TEXT​

EV(121173,DCM,"Physician​1-n​

U​

 

 

 

 

 

Note")​

 

 

 

38​

>>​

CONTAINS​

COMPOSITE​EV (112359, DCM,​

1​

U​

SOPClassUIDshall​

 

 

 

 

"Supporting Information")​

 

 

be Encapsulated​

 

 

 

 

 

 

 

PDF Storage​

- Standard -​

 

 

 

DICOM PS3.16 2020a - Content Mapping Resource​

Page 397​

 

NL​

Rel with​

VT​

Concept Name​

VM​

Req​ Condition​

Value Set​

 

 

Parent​

 

 

 

Type​

Constraint​

39​

>>​

CONTAINS​

COMPOSITE​EV (112372, DCM, "Derived​ 1-n​

U​

 

 

 

 

 

Planning Images")​

 

 

 

40​

>>​

CONTAINS​

COMPOSITE​EV (112353, DCM, "Spatial​

1-n​

U​

References Spatial​

 

 

 

 

Registration")​

 

 

Registration SOP​

 

 

 

 

 

 

 

Instances and​

 

 

 

 

 

 

 

Deformable Spatial​

 

 

 

 

 

 

 

Registration SOP​

 

 

 

 

 

 

 

Instances​

41​

>>>​

HAS​

UIDREF​

EV (112227, DCM, "Frame of​1-n​

U​

 

 

 

PROPERTIES​

Reference UID")​

 

 

 

42​

>>​

CONTAINS​

COMPOSITE​EV (112373, DCM, "Derived​ 1-n​

U​

References SOP​

 

 

 

 

Planning Data")​

 

 

Instances except​

 

 

 

 

 

 

 

Images and Spatial​

 

 

 

 

 

 

 

Registrations​

43​

>>>​

HAS​

UIDREF​

EV (112357, DCM, "Derived​ 1-n​

MC​ IFF row 42​

 

 

 

PROPERTIES​

Fiducial")​

 

references a​

 

 

 

 

 

 

 

Fiducial SOP​

 

 

 

 

 

 

Instance​

 

44​

>>>>​

HAS​

TEXT​

EV (112369, DCM, "Fiducial​

1​

U​

 

 

 

CONCEPT​

 

Intent")​

 

 

 

 

 

MOD​

 

 

 

 

 

45​

>>​

CONTAINS​

COMPOSITE​EV (112364, DCM, "Related​ 1-n​

U​

 

 

 

 

 

PatientDataNotUsedDuring​

 

 

 

 

 

 

 

Planning")​

 

 

 

Content Item Descriptions​

Row 7​

If an Implant Assembly Template was used for the planning, it should be referenced here.​

Row 9​

ID given to this Implant Component. Used to reference this specific Component within the Implantation​

 

Plan.​

Row 10​

See description of Component Type Code Sequence (0076,0034) Attribute in Section C.29.2.1 “Implant​

 

Assembly Template Module” in PS3.3​

Row 11​

ReferencetotheTemplatethatdescribesthatcomponent.MaybethesameImplantTemplateasreferenced​

 

in row 13. The target of the reference may not be needed or available during implantation. e.g., if the plan​

 

is opened in another hospital where those implant templates are not used. No purpose of reference is​

 

specified.​

Row 12​

This Frame of Reference is the Frame of Reference of the Implant Component (Frame of Reference UID​

 

(0020,0052) Attribute in the “Generic Implant Template Description Module” in PS3.3).​

 

This may help to find the right registration information (row 43).​

Row 13​

References the Original Template that was the basis for the Derived Template. May be the same Implant​

 

Template as referenced in row 11. The target of the reference may not be needed or available during​

 

implantation, e.g., if the plan is opened in another hospital where those implant templates are not used.​

Row 14​

If there is no Component Connection between sets of Implant Components, one Assembly must be used​

 

for each set.​

Row 17​

The ID of a planned Component that is defined in this document and that is part of this Relation.​

Row 18​

See description of Mating Feature Set ID (0068,63C0) Attribute in the “Generic Implant Template Mating​

 

Features Module” in PS3.3​

Row 19​

SeedescriptionofMatingFeatureID(0068,63F0)Attributeinthe“GenericImplantTemplateMatingFeatures​

 

Module” in PS3.3​

- Standard -​

Page 398​

DICOM PS3.16 2020a - Content Mapping Resource​

Row 21​

See description of Degree of Freedom ID (0068,6410) Attribute in the “Generic Implant Template Mating​

 

Features Module” in PS3.3​

 

 

 

Row 22 - 27​

Defines the range or exact value that was selected or calculated by the planning application.​

Row 31​

Defines the calibrated Horizontal Pixel Spacing that was used by the planning application, which may be​

 

different from the spacing encoded in the referenced Image SOP Instance.​

Row 32​

Defines the calibrated Vertical Pixel Spacing that was used by the planning application, which may be​

 

different from the spacing encoded in the referenced Image SOP Instance.​

Row 33​

Any patient data other than Image IEs used for the planning, e.g., Surface Segmentations.​

Row 34​

Fiducials selected by the user for registration of implant components referenced in the parent Content Item.​

Row 35​

UsercommentabouttheFiducial.Thismaybethereasonitwasselected,theintendeduse,theanatomical​

 

or non-anatomical structure that the Fiducial represents, or any other intent.​

Row 38​

All kinds of information in PDF form that are created by a planning application may be referenced here,​

 

e.g., drawings.​

 

 

 

Row 39​

All kinds of images that are created by a planning application should be referenced here, e.g., images that​

 

show patient images overlaid with contour information of the Implant Component, or images that show how​

 

several implant components may be composed, or merged patient images.​

Row 40​

References registration objects that contain registration data that is relevant for this Implantation Plan, e.g.,​

 

registration of Implant Components.​

 

 

 

Rows 5, 6​

IdentifiesoneormoreitemswithinthesequenceofreferencedFramesofReference(RegistrationSequence​

 

(0070,0308) in the Spatial Registration Module or Deformable Registration Sequence (0064,0002) in the​

 

“Deformable Spatial Registration Module” in PS3.3) that are relevant for this Implantation Plan. See​

 

Figure A-13.​

 

 

 

Row 42​

Any patient data created during the planning process that is not referenced in row 39 and 40, e.g., Surface​

 

Segmentation Instances created by the planning application.​

Row 43​

These Fiducials are derived from the Fiducials identified in Row 34.​

Row 45​

References to any relevant patient data containing IOD instances that were not used in planning or derived​

 

from it but belong to the patient model. Might be reports, images, surface segmentations, or other.​

 

Implementation Plan SR Document

 

 

 

 

...

Registration Object

 

 

 

 

 

Spatial Registration

Registration

 

Frame of Reference

 

 

 

 

 

For UID

Reference FoR

 

 

 

 

 

 

 

 

For UID

Reference FoR

 

 

 

 

 

 

 

Reference FoR

 

 

 

 

 

 

Figure A-13. References to Registration Objects​

TID 7001 Related Implantation Reports​

ThisgeneralTemplateprovidesameanstoreferencerelatedImplantationPlanSRDocumentinstancesthatarenotpreviousReports.​ Other Implantations that are planned to be done during the same intervention should be referenced here.​

Type:​

Extensible​

Order:​

Significant​

Root:​

No​

- Standard -​

DICOM PS3.16 2020a - Content Mapping Resource​ Page 399​

Table TID 7001. Related Implantation Reports​

 

NL​ Rel with Parent​

VT​

Concept Name​

VM​

Req Type​Condition​ Value Set​

 

 

 

 

 

 

Constraint​

1​

 

CONTAINER​

EV (112365, DCM,​

1​

M​

 

 

 

 

"Related Implantation​

 

 

 

 

 

 

Reports")​

 

 

2​

>​

CONTAINS​ COMPOSITE​

 

1-n​

M​

Acquisition Context SR IOD Templates ​

The Templates that comprise the Acquisition Context SR are interconnected as follows:​ •​TID 8101 “Preclinical Small Animal Image Acquisition Context”​

•​TID 1204 "Language of Content Item and Descendants"​ •​TID 1001 "Observation Context"​

•​TID 8110 “Biosafety Conditions”​ •​TID 8121 “Animal Housing”​ •​TID 8122 “Animal Feeding”​ •​TID 8140 “Heating Conditions”​ •​TID 8150 “Circadian Effects”​

•​TID 8170 “Physiological Monitoring Performed During Procedure”​ •​TID 8130 “Anesthesia”​

•​TID 8131 “Medications and Mixture Medications”​

•​TID 9002 “Medication, Substance, Environmental Exposure”​ •​TID 8182 “Exogenous Substance Administration”​

TID 8101 Preclinical Small Animal Image Acquisition Context​

Thisroottemplateencodesadescriptionoftheconditionspresentduringandrelatedtodataacquisitionforasingleimagingprocedure.​

Note​

1.​It is not expected that a single instance be used to describe the entire life of an animal, unless it is sacrificed after a​ singleprocedure.Rather,separateinstanceswillbeusedforseparateprocedures,thoughtheremaybesomeduplication​ of common information, such as about the home cage environment.​

2.​It is expected that an SR instance encoded using this template will be contained in the same Study as other instances​ created during the procedure, e.g., with a common Study Instance UID. If this is not practical, e.g., due to recording on​ a separate device without use of a shared Modality Worklist, then commonality of other Study level attributes may be​ necessary to link procedures (and possibly coerce the Study Instance UID to a common value).​

Type:​

Extensible​

Order:​ Non-Significant​

Root:​

Yes​

- Standard -​

Page 400​ DICOM PS3.16 2020a - Content Mapping Resource​

Table TID 8101. Preclinical Small Animal Image Acquisition Context​

 

NL​ RelwithParent​ VT​

Concept Name​

VM​

Req​Condition​ Value Set Constraint​

 

 

 

 

 

 

Type​

 

1​

 

 

CONTAINER​EV (127001, DCM,​

1​

M​

Root node​

 

 

 

 

"Preclinical Small Animal​

 

 

 

 

 

 

 

ImagingAcquisitionContext")​

 

 

 

2​

>​

HASCONCEPT​INCLUDE​

DTID 1204 "Language of​

1​

M​

 

 

 

MOD​

 

Content Item and​

 

 

 

 

 

 

 

Descendants"​

 

 

 

3​

>​

HAS OBS​

INCLUDE​

DTID 1001 "Observation​

1​

M​

 

 

 

CONTEXT​

 

Context"​

 

 

 

5​

>​

CONTAINS​

INCLUDE​

DTID 8110 “Biosafety​

1​

U​

 

 

 

 

 

Conditions”​

 

 

 

6​

>​

CONTAINS​

CONTAINER​EV (127005, DCM, "Animal​

1-n​

U​

 

 

 

 

 

handling during specified​

 

 

 

 

 

 

 

phase")​

 

 

 

7​

>>​

HASCONCEPT​CODE​

EV(127006,DCM,"Phaseof​ 1​

M​

DCID 634 “Phase of​

 

 

MOD​

 

animal handling")​

 

 

Animal Handling”​

8​

>>​

CONTAINS​

DATETIME​ EV (111526, DCM,​

1​

U​

 

 

 

 

 

"DateTime Started")​

 

 

 

9​

>>​

CONTAINS​

DATETIME​ EV (111527, DCM,​

1​

U​

 

 

 

 

 

"DateTime Ended")​

 

 

 

10​

>>​

CONTAINS​

INCLUDE​

DTID8121“AnimalHousing”​ 1​

U​

 

11​

>>​

CONTAINS​

INCLUDE​

DTID 8122 “Animal Feeding”​1-n​

U​

 

12​

>>​

CONTAINS​

INCLUDE​

DTID 8140 “Heating​

1​

U​

 

 

 

 

 

Conditions”​

 

 

 

13​

>>​

CONTAINS​

INCLUDE​

DTID 8150 “Circadian​

1​

U​

 

 

 

 

 

Effects”​

 

 

 

14​

>>​

CONTAINS​

INCLUDE​

DTID 8170 “Physiological​

1​

U​

 

 

 

 

 

MonitoringPerformedDuring​

 

 

 

 

 

 

 

Procedure”​

 

 

 

15​

>​

CONTAINS​

INCLUDE​

DTID 8130 “Anesthesia”​

1​

U​

 

16​

>​

CONTAINS​

INCLUDE​

DTID 9002 “Medication,​

1​

U​

$ContainerConcept = EV​

 

 

 

 

Substance, Environmental​

 

 

(10160-0, LN, "History Of​

 

 

 

 

Exposure”​

 

 

Medication Use")​

$CodeConcept = EV​

(111516, DCM,​

"Medication Type")​

$Route = DCID 11 “Route​

of Administration”​

- Standard -​

Соседние файлы в папке PS-2020a