- •16.1Introduction...........................................165
- •16.2Step1-Intersectionlayout..................................165
- •4.1.5Numberofsignalgroups
- •4.3.5Signalgroupsselection
- •4.4 Step3-Minimumintergreentimematrix
- •4.10.1Numberofplans
- •06:Activeifthe inphasbeenactivesincethelast
- •1:A•plancyclecounter
- •5Jumpto12
- •9Jumpto12
- •14:Jumpto21
- •Action-Table
- •16.1Introduction
- •16.2Step1-Intersectionlayout
4.1.5Numberofsignalgroups
”Numberofsignalgroups”isusuallyalreadydecidedintrafficdesign.Itdependsonthein-tersectionlayoutandnumberofsignalizeddirections(itisnotthesamenumberasnumberofsignalheads).
Figure24:Numberofsignalgroups
Forexample,forthefollowingintersectionlayoutyouwouldhavetoprogram6signalgroups.4vehiclegroups(G1,G2,G3,G4)and2pedestriangroups(P5,P6).
Figure25:Numberofsignalgroupsintersectionlayout
4.1.6Failuremodedark/yellowflashing
Therearetwomaincriticalfailuremodesavailable:darkandyellowflashing.TheFailuremodeconcernscriticalfailureswhenthecontrollercan’tstayinthreecolorsoperationanylonger.
Figure26:Numberofsignalgroups
4.2 Additionalsettings-STEP1
4.2.1Mainsvoltagesupervision[V]
Formoreinformationaboutmainsvoltagesupervisionsee:APPENDIXIIIsection15page162
4.2.2Controloptions
Figure27:Controloptions
Countryareacode
Someparametersdependonthesettingofthecountrycodeareaparameter.Thiswillbementionedintheindividualparameterdescriptionwhenthisisthecase-”ITC-2Programmersmanual-v86.pdf”
Figure28:Countryareacode
Intergreentimeoptions
ThisintergreentimeoptionapplytoparameterfunctionF997(STEP3)andF006(STEP8).TheintergreentimecanbecountdowninatwodifferentwaysintheITC-2controller.
Figure29:Intergreentimeoptions
Flashingsignalsfrequency
Youcandecidethefleshingsignalsfrequencyseparatelyforred,yellowandgreen.
Figure30:Flashingsignalsfrequency
4.2.3Plans(trafficprograms)triggeringpriority
Theplansourcepriority(F994)Atrafficplanselectedbyforcedplan(F0N20)orfromfailuremode(F0N25)havethehighestplansourcepriority-prioritylevel0.PlanchangestothesesourceswillalwaysbeimmediatelyifnotsetinF994N12accordingtoplanchangemodedenedbyparam-etersF3PN20toF3PN23.Theprioritylevelofplansourcesfromtrafcsituation(parameterF2SN1)andstartupplan(parameterF0N22)arexedtolevel12and13respectively.PlanchangestothesesourceswillbeaccordingtoplanchangemodesdenedbyparametersF3PN20toF3PN23.Theremainingplansourceprioritiescanbesetinthisfunction.Multiplesourcescansharethesameprioritylevelbutthesourcewiththehighestdefaultlevelamongthesesourceswillinternallyhavethehighestpriority.Howeverasourcewhichissettousethedefaultlevelwillhavethelowestpriorityamongsourceswithsharedprioritylevel.ThisfunctionrequiresITCv5.50orhigher.
Figure31:Plans(trafficprograms)triggeringpriority
TS(Trafficsituation),FP(Forced),LP(LocalProgram),EM(Emergencylogic),WS(Workstation),CB(ControlBlock),CL(Calendarclock),TP(Traffic-Programmaster)andST(Startprogram).
4.3 STEP2-Signalgroups
Figure32:STEP2
4.3.1Signalgrouplist
Thesignalgrouplistisbasedonthreesections:groupname(1),signalgrouptype(2)andminsignalgroupsequence(3).
Figure33:Signalgroupslist
4.3.2Signalgroupname(1)
Thesignalgroupnamecanbeanytextwithmax5characters.Itisusual”G1”,”G2”or”V1”,
”V2”forthevehiclegrouptypesand”P1”,”P2”forthepedestriangrouptypes.
4.3.3Signalgrouptype(2)
Choosethesignalgrouptypefromthelist.
Figure34:Signalgroupstype
ThereisavariousnumberofdifferentsignalgrouptypesspecificfortheITCcontroller.Mostpopulartypesare1and8respectivelyforvehicleandpedestriangroups.
Figure35:Mostcommonsignalgroupstype
4.3.4Signalgroupsminsequence(3)
Thesignalgroupminsequenceisdifferentineachcountry.Somecountriesdon’tusered/yel-lowsignalinthebeginningofgreensignal,whileothercountriesrequire3oreven4sred/yel-low.
Figure36:Redyellowsignal
Therearealsodifferentrequirementsconcerningthemingreentime.Somecountriesrequire
5swhentheothercountriesfollow7smingreentimerule.
Figure37:Mingreen
Differentcountrieshavealsodifferentwaysofchangingfromgreentored.Somecountriesrequire4sgreenflashingplus3sonyellowsignal.Othercountrieschangefromgreendirectlytored.
Figure38:Changingtored
TheseandmanydifferentsignalgroupsequencescanbeprogrammedintheITCcontroller.Activateeachsignalperiod(red/yellow,mingreen,greenflashingoryellow)bytypingtimeinseconds.Youcanalsoeasilydeactivatespecificperiodsbytyping00.0s.
Marksignalgroupsonthelistaboveandpress”Apply”button(1)toupdatethegroupswith
thepredefinedsignalgroupsequence(2).
Figure39:Signalgroupsminsequence
Formoreinformationaboutspecialgrouptypesandspecialgroupsequencessee:Specialsignalgroupsequenceprogrammingsection10page127.