© Siemens AG 2008

Selection and ordering

3/2

3/3

3/4

3/5

3/6

3/7

3/9

3/12

3/15

3/18

3/21

3/24

3/34

3/45

Guideline for drive selection

Specification of motor type according to cooling method and degree of protection Preselection of the motor according to torque and output

Order No. code

Order No., identification codes

Order No. supplements

Field voltage, types of construction

Series

1GG6, 1GH6 and 1HS6 Sizes 160 and 180

Size 160

Size 180

Series

1GG6, 1GH6 and 1HS6 Sizes 200 to 280

Size 200

Size 225

Size 250

Size 280

Series

1GG7, 1GH7 and 1HS7 Sizes 355 to 450

Size 355

Size 400

Size 450

Series

1GG5, 1GH5 and 1HS5 Sizes 500 and 630

3/56 Size 500

3/67 Size 630

Series 1HQ6 Sizes 180 to 280

3/78 Size 180

3/80 Size 200

3/83 Size 225

3/86 Size 250

3/89 Size 280

Series 1HQ7 Sizes 355 to 450

3/92 Size 355

3/98 Size 400

3/108 Size 450

Options

3/118 Mounted assemblies 3/120 Operation and diagnostics 3/121 Mounted equipment

Siemens DA 12 · 2008

© Siemens AG 2008

Selection and ordering

Guideline for drive selection

These "Recommendations for drive selection" guide you step-by-step through this catalog to the required motor

Further notes and support with project engineering can be found in the engineering information for Catalog DA 12.

The configuration tool SIZER is also available for selecting the motor.

Details and explanations for the converters can be found in Catalogs DA 21 (Chassis Converters) and DA 22 (Converter Cabinet Units).

Step 1

Technical requirements for the motor

 

Determine the required

Rated supply voltage

3 AC 50/60 Hz, 400, 500 or 690 V

 

product profile

 

 

 

Operating mode

1Q/4Q

 

 

 

 

Degree of protection and type of

IP.. / IC..

 

 

cooling

 

 

 

Speed

n =................rpm

 

Determine the rated armature voltage

3

Step 2

 

 

Determine the installation conditions

Step 3

 

 

Determine the range of possible motors

Step 4

 

 

Determine the motor Order No.

Step 5

 

 

Speed adaptation and the associated parameter change

Step 6

 

 

Complete the motor Order No.

Step 7

 

 

Select the SIMOREG converter and the line-side components

Output

P =................kW

 

Torque

M = P 9550/n = ................Nm

 

Type of construction

IM ..

 

 

 

 

Rated supply voltage

Operating mode

Rated armature voltage

 

 

 

2 AC 50/60 Hz 400 V

4Q

280 V DC

2 AC 50/60 Hz 400 V

1Q

310 V DC

3 AC 50/60 Hz 400 V

4Q

420 V DC

3 AC 50/60 Hz 400 V

1Q

470 V DC

3 AC 50/60 Hz 500 V

4Q

520 V DC

3 AC 50/60 Hz 500 V

1Q

600 V DC

3 AC 50/60 Hz 690 V

4Q

720 V DC

3 AC 50/60 Hz 690 V

1Q

810 V DC

 

 

 

Environmental requirements for the motor Æ Page 2/2

 

 

 

 

Ambient temperature

40 °C

> 40 °C

Site altitude

1000 m

> 1000 m

Determining the factors for output

For determining the factors for output

and speed change

 

and speed change (see Part 2 under

 

 

"Installation and operating conditions")

 

 

 

Select the motor Æ Pages 3/3 and 3/4

Select the size and therefore the possible motors on the basis of the following parameters: type of cooling, degree of protection, torque and output range.

Detailed selection of the motor Æ Pages 3/7 to 3/117

Determine the motor Order No. according to the following parameters: rated armature voltage, speed, torque and output from the "Selectionand ordering data" for the motors that have already been identified as possibilities.

Adapt the speed if necessary

 

 

n = nN

n < nN

n > nN

Speed adaptation:

Speed adaptation:

Speed adaptation:

not required

through armature control

through field weakening

 

U= UN n / nN

U = constant

 

P= PN n / nN

P = constant

 

MN = constant

M = MN nN / n

Selection of the options Æ Page 3/118 to 3/121

Determine the options and the associated short codes for special versions (mounted assemblies, operation and diagnostics and mounted equipment).

For Order No. of the converter and the line-side components, see Catalogs DA 21 and DA 22.

3/2

Siemens DA 12 · 2008

 

 

© Siemens AG 2008

Selection and ordering

Guideline for drive selection

Determining the motor type according to type of cooling and degree of protection (for further selection according to torque and output, see overleaf)

The modular structure of the motors enables the following cooling methods and degrees of protection to be derived from one basic motor module

Cooling method

Designation to

DIN EN 60 034,

Part 6

Open-looped cooling circuit

Suitable for use

Internal cool-

IC06

in dry indoor

ing with radi-

 

rooms with low

ally mounted

 

dust levels

fan unit

 

 

Degree of pro-

Adapting the basic motor module

Motor

 

tection

 

 

 

 

 

 

 

type

With duct

Designation to

 

 

 

 

 

 

 

 

connec-

DIN EN 60 034,

 

 

 

 

 

 

 

 

tion

Part 5

 

 

 

 

 

 

 

 

IP23

Fan unit

 

1GG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G_DA12_XX_00002

G_DA12_XX_00005

Internal cool-

IC17

Single-

IP23

No

 

 

 

 

 

ing using sepa-

 

end (cool-

 

 

 

 

 

 

1GH

 

 

 

 

 

 

 

rately-mounted

 

ing air

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

fan through

 

inlet)

 

 

 

 

 

 

 

 

 

 

 

G_DA12_XX_00005

 

duct

 

 

 

 

 

 

IC37

Both ends

IP54

 

 

 

 

 

 

 

 

 

 

 

 

 

(cooling air inlet and outlet)

Closed-looped cooling circuit

 

 

 

3

Suitable for use

Heat exchange

IC A06 A66 –

IP54

Air-to-air

outdoors or in

through exter-

 

 

heat

1HQ

extremely dusty

nal cooling

 

 

exchanger,

 

and/or humid

using air-to-air

 

 

fan unit

 

environments

heat exchanger

 

 

 

 

 

 

 

 

 

G_DA12_XX_00007

 

Heat exchange

IC W37 A86 –

IP54

Air-to-water

 

 

through exter-

 

 

heat

1HS

 

nal cooling

 

 

exchanger,

 

 

using air-to-

 

 

fan unit

 

 

water heat

 

 

 

 

 

exchanger

 

 

 

 

G_DA12_XX_00008

Siemens DA 12 · 2008

3/3

 

 

© Siemens AG 2008

Selection and ordering

Guideline for drive selection

Preselection of the motor according to torque and output

 

Motor type/

Size

Torque

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Detailed selection

 

series

 

Nm

 

100

1000

10000

 

kW

 

10

100

1000

10000

 

and ordering data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page

 

 

 

1GG6/1GH6

160

256

506

 

 

 

 

 

 

 

 

 

 

 

 

30

111

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3/7

3/8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

180

450

670

 

 

 

 

 

 

 

 

 

 

 

 

44.2

191

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3/9

3/11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200

670

965

 

 

 

 

 

 

 

 

 

 

 

 

64.5

256

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3/12

3/14

 

 

225

1070

1550

 

 

 

 

 

 

 

 

 

 

 

 

94.5

340

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3/15

 

3/17

 

 

250

1630

2300

 

 

 

 

 

 

 

 

 

 

 

 

121

436

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3/18

 

3/20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

280

2400

3360

 

 

 

 

 

 

 

 

 

 

 

 

170

510

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3/21

 

3/23

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1GG7/1GH7

355

2950

8280

 

 

 

 

 

 

 

 

 

 

 

 

236

770

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3/24

 

3/33

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

400

4400

12920

 

 

 

 

 

 

 

 

 

 

 

 

230

880

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3/34

 

3/44

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

450

6830

18400

 

 

 

 

 

 

 

 

 

 

 

 

197

1020

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3/45

 

3/55

 

1GG5/1GH5

500

5700

20600

 

 

 

 

 

 

 

 

 

 

 

288

1110

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3/56

 

3/66

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

630

16000

44500

 

 

 

 

 

 

 

 

 

 

 

344

1610

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3/67

 

3/77

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1HQ6

180

264

482

 

 

 

 

 

 

 

 

 

 

 

 

37.6

110

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3/78

3/79

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200

422

715

 

 

 

 

 

 

 

 

 

 

 

 

55.5

169

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3/80

3/82

 

 

225

630

1180

 

 

 

 

 

 

 

 

 

 

 

 

82

264

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3/83

3/85

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

250

1170

1780

 

 

 

 

 

 

 

 

 

 

 

 

107

340

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3/86

3/88

 

 

280

1770

2750

 

 

 

 

 

 

 

 

 

 

 

 

151

436

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3/89

 

3/91

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1HQ7

355

2300

7440

 

 

 

 

 

 

 

 

 

 

 

 

220

645

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3/92

 

3/97

3

 

400

3400

11700

 

 

 

 

 

 

 

 

 

 

 

 

225

770

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3/98

 

3/107

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

450

5610

15800

 

 

 

 

 

 

 

 

 

 

 

 

176

845

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3/108

 

3/117

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1HS6

180

450

670

44.2

191

3/9

3/11

 

200

670

965

64.5

256

3/12

3/14

 

225

1070

1550

94.5

340

3/15

3/17

 

250

1630

2300

121

436

3/18

3/20

 

280

2400

3360

170

510

3/21

3/23

1HS7

355

2950

– 8280

 

 

 

 

 

 

 

 

 

236

770

 

 

 

 

 

 

3/24

3/33

 

400

4400

 

 

 

 

 

 

 

 

 

 

 

230

 

 

 

 

 

 

 

 

 

3/34

 

 

 

12920

 

 

 

 

 

 

 

 

 

880

 

 

 

 

 

 

 

 

3/44

 

450

6830

18400

 

 

 

 

 

 

 

 

 

197

1020

 

 

 

 

 

 

 

3/45

 

3/55

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1HS5

500

5700

20600

 

 

 

 

 

 

 

 

 

288

1110

 

 

 

 

 

 

 

3/56

 

3/66

 

630

16000

44500

 

 

 

 

 

 

 

 

 

344

1610

 

 

 

 

 

 

 

 

3/67

 

3/77

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Torque

 

 

 

 

 

 

 

 

 

 

 

Output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nm

 

 

100

1000

10000

 

kW

 

10

100

1000

10000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3/4

Siemens DA 12 · 2008

 

 